SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lu Yalin) "

Sökning: WFRF:(Lu Yalin)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lu, Longyu, et al. (författare)
  • Tunable Magnetism in Atomically Thin Itinerant Antiferromagnet with Room-Temperature Ferromagnetic Order
  • 2024
  • Ingår i: Nano Letters. - 1530-6984. ; 24:20, s. 5984-5992
  • Tidskriftsartikel (refereegranskat)abstract
    • Addressing the need for modulated spin configurations is crucial, as they serve as the foundational building blocks for next-generation spintronics, particularly in atomically thin structures and at room temperature. In this work, we realize intrinsic ferromagnetism in monolayer flakes and tunable ferro-/antiferromagnetism in (Fe0.56Co0.44)5GeTe2 antiferromagnets. Remarkably, the ferromagnetic ordering (≥1 L) and antiferromagnetic ordering (≥4 L) remain discernible up to room temperature. The TC (∼310 K) of the monolayer flakes sets a record high for known exfoliated monolayer van der Waals magnets. Within the framework of A-type antiferromagnetism, a notable odd-even layer-number effect at elevated temperatures (T = 150 K) is observed. Of particular interest is the strong ferromagnetic order in even-layer flakes at low temperatures. The intricate interplay among magnetic field strength, layer number, and temperature gives rise to a diverse array of phenomena, holding promise not only for new physics but also for practical applications.
  •  
2.
  • Su, Wei, et al. (författare)
  • Infection probability under different air distribution patterns
  • 2021
  • Ingår i: Building and Environment. - : Elsevier. - 0360-1323 .- 1873-684X. ; 207:Part B
  • Tidskriftsartikel (refereegranskat)abstract
    • Infectious diseases have caused significant physical harm to humans as well as enormous economic losses over the years. Effective ventilation and distribution of fresh air could help to reduce indoor cross-infection. The computational fluid dynamics (CFD) method was used in this paper to investigate airborne transmission with seven different air distribution methods. The revised Wells-Riley model, which took into account the non-uniform air distribution generated with the methods, was used to calculate the infection probability in an office room shared by ten occupants for 4 h. One of the occupants was an infector. The significance of the infector's location was studied. The obtained infection probability was compared to that obtained in the case of complete air mixing, which is uncommon in practice. Under specified conditions of this study, personalized ventilation (PV) performed the best in terms of preventing cross-infection, followed by displacement ventilation (DV), impinging jet ventilation (IJV), stratum ventilation (SV) and wall attachment ventilation (WAV). The number of infected occupants was reduced below the number obtained under the complete mixing assumption by using these air distribution methods. Mixing ventilation (MV) and diffuse ceiling ventilation (DCV) exhibited the worst performance. In comparison to the case of complete mixing the infection probability for seven out of nine susceptible occupants was higher with MV and for all occupants in the case of DCV. In SV, the position of the infector had a clear impact on the infection probability of susceptible individuals. WAV may perform better in practice if the system is well designed. The location of the exhaust outlets had a significant impact on the infection probability for DCV.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy