1.
  • Andersson, M., et al. (författare)
  • Coupling of lattice boltzmann and volume of fluid approaches to study the droplet behavior at the gas diffusion layer/gas channel interface
  • 2018. - 13
  • Ingår i: ECS Transactions. - : The Electrochemical Society. - 1938-6737 .- 1938-5862. - 9781607688600 ; 86, s. 329-336
  • Konferensbidrag (refereegranskat)abstract
    • A typical polymer electrolyte fuel cell (PEFC) flow field consists of micro/minichannels. The continues removal of liquid water from the cathode channels is a critical topic, as water droplets forming in the channels may block the transport of gaseous oxygen to the active sites, which not only gives an uneven current distribution and substantial loss of performance, but also, increases degradation rates and unstable operation. Water generated by the electrochemical reactions condenses, depending on temperature mainly, into liquid form, potentially flooding various part of the PEFC. The aim of this work is to obtain an increased understanding of the droplet behavior at the gas diffusion layer (GDL) interface with the gas channels in PEFCs by the coupling of Lattice Boltzmann (LB) and Volume of Fluid (VOF) approaches. A multiscale environment is established with input parameters in the VOF model being extracted from in-house LB calculations. It is clear that the contact angle as well as the size of the liquid droplet vary with positions at the GDL surface, depending on the stochastic GDL geometry. A VOF model describing one straight channel with one gas inlet, one liquid inlet (at the GDL surface) and one two-phase outlet is employed.
  •  
2.
  • Beale, S. B., et al. (författare)
  • Combined two-phase co-flow and counter-flow in a gas channel/porous transport layer assembly
  • 2020. - 9
  • Ingår i: PRiME 2020 : Polymer Electrolyte Fuel Cells and Electrolyzers 20 (PEFC and E 20) - Polymer Electrolyte Fuel Cells and Electrolyzers 20 (PEFC and E 20). - : The Electrochemical Society. - 1938-5862 .- 1938-6737. - 9781607685395 ; 98:9, s. 305-315
  • Konferensbidrag (refereegranskat)abstract
    • This paper considers a detailed numerical analysis of combined liquid-gas co-flow in a gas channel, with liquid-gas counter-flow in a porous transport layer, as is typically found on the cathode side of a polymer electrolyte fuel cell. The geometry is obtained by digital reconstruction of nano-computer tomography images. From this, the domain is tessellated with an unstructured castellated or octree mesh, upon which the equations of mass and momentum are solved by means of a volume of fluid method. Liquid water is produced from an electrode where gaseous oxygen is simultaneously consumed by electrochemical reduction; Liquid-gas counter flow in the porous transport layer results in liquid drops being entrained in co-flow in the gas channels and convected by the gas downstream.
  •  
3.
  • Farahi, A., et al. (författare)
  • Mass variance from archival X-ray properties of Dark Energy Survey Year-1 galaxy clusters
  • 2019
  • Ingår i: Monthly notices of the Royal Astronomical Society. - : OXFORD UNIV PRESS. - 0035-8711 .- 1365-2966. ; 490:3, s. 3341-3354
  • Tidskriftsartikel (refereegranskat)abstract
    • Using archival X-ray observations and a lognormal population model, we estimate constraints on the intrinsic scatter in halo mass at fixed optical richness for a galaxy cluster sample identified in Dark Energy Survey Year-One (DES-Y1) data with the redMaPPer algorithm. We examine the scaling behaviour of X-ray temperatures, T-X, with optical richness, lambda(RM), for clusters in the redshift range 0.2 < z < 0.7. X-ray temperatures are obtained from Chandra and XMM observations for 58 and 110 redMaPPer systems, respectively. Despite non-uniform sky coverage, the T-X measurements are > 50 per cent complete for clusters with lambda(RM) > 130. Regression analysis on the two samples produces consistent posterior scaling parameters, from which we derive a combined constraint on the residual scatter, sigma(ln) (T) (vertical bar) (lambda) = 0.275 +/- 0.019. Joined with constraints for T-X scaling with halo mass from the Weighing the Giants program and richness-temperature covariance estimates from the LoCuSS sample, we derive the richness-conditioned scatter in mass, sigma(ln) (M) (vertical bar) (lambda) = 0.30 +/- 0.04((stat)) +/- 0.09((sys)), at an optical richness of approximately 100. Uncertainties in external parameters, particularly the slope and variance of the T-X-mass relation and the covariance of T-X and lambda(RM) at fixed mass, dominate the systematic error. The 95 per cent confidence region from joint sample analysis is relatively broad, sigma(ln) (M) (vertical bar) (lambda) is an element of [0.14, 0.55], or a factor 10 in variance.
  •  
4.
  • Zhang, Shidong, et al. (författare)
  • Simple and complex polymer electrolyte fuel cell stack models : A comparison
  • 2018. - 13
  • Ingår i: ECS Transactions. - : The Electrochemical Society. - 1938-6737 .- 1938-5862. - 9781607685395 ; 86, s. 287-300
  • Konferensbidrag (refereegranskat)abstract
    • In this paper, two distinct polymer electrolyte fuel cell stack models are constructed: a detailed numerical model (DNM) employing a fine-scale computational mesh and a coarse-mesh approach based on a distributed resistance analogy (DRA) where diffusion terms in the transport equations are replaced by rate terms. Both methods are applied to a 5-cell, high-temperature polymer electrolyte fuel cell stack with an active area of 200 cm2 per cell. The polarization curve and local current density distributions from both the DRA and DNM are compared with experimental data, finding good agreement. Temperature, pressure, Nernst potential, and species distributions are also exhibited. The DNM displays details of fine-scale local extrema not captured by the DRA; however, the latter requires orders of magnitude less computer processor power and memory for execution. Both methods provide much finer-scale results than present experimental techniques.
  •  
5.
  • Zhang, Y., et al. (författare)
  • Dark Energy Surveyed Year 1 results : calibration of cluster mis-centring in the redMaPPer catalogues
  • 2019
  • Ingår i: Monthly notices of the Royal Astronomical Society. - : OXFORD UNIV PRESS. - 0035-8711 .- 1365-2966. ; 487:2, s. 2578-2593
  • Tidskriftsartikel (refereegranskat)abstract
    • The centre determination of a galaxy cluster from an optical cluster finding algorithm can be offset from theoretical prescriptions or N-body definitions of its host halo centre. These offsets impact the recovered cluster statistics, affecting both richness measurements and the weak lensing shear profile around the clusters. This paper models the centring performance of the redMaPPer cluster finding algorithm using archival X-ray observations of redMaPPer-selected clusters. Assuming the X-ray emission peaks as the fiducial halo centres, and through analysing their offsets to the redMaPPer centres, we find that similar to 75 +/- 8 per cent of the redMaPPer clusters are well centred and the mis-centred offset follows a Gamma distribution in normalized, projected distance. These mis-centring offsets cause a systematic underestimation of cluster richness relative to the well-centred clusters, for which we propose a descriptive model. Our results enable the DES Y1 cluster cosmology analysis by characterizing the necessary corrections to both the weak lensing and richness abundance functions of the DES Y1 redMaPPer cluster catalogue.
  •  