SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Martinez Galvan Eduardo) "

Sökning: WFRF:(Martinez Galvan Eduardo)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Galvan-Alvarez, Victor, et al. (författare)
  • Antioxidant enzymes and Nrf2/Keap1 in human skeletal muscle: Influence of age, sex, adiposity and aerobic fitness
  • 2023
  • Ingår i: Free Radical Biology & Medicine. - : Elsevier Inc.. - 0891-5849 .- 1873-4596. ; 209:Part 2, s. 282-291
  • Tidskriftsartikel (refereegranskat)abstract
    • Whether a higher aerobic fitness is associated with increased expression of antioxidant enzymes and their regulatory factors in skeletal muscle remains unknown. Although oestrogens could promote a higher antioxidant capacity in females, it remains unknown whether a sex dimorphism exists in humans regarding the antioxidant capacity of skeletal muscle. Thus, the aim was to determine the protein expression levels of the antioxidant enzymes SOD1, SOD2, catalase and glutathione reductase (GR) and their regulatory factors Nrf2 and Keap1 in 189 volunteers (120 males and 69 females) to establish whether sex differences exist and how age, VO2max and adiposity influence these. For this purpose, vastus lateralis muscle biopsies were obtained in all participants under resting and unstressed conditions. No significant sex differences in Nrf2, Keap1, SOD1, SOD2, catalase and GR protein expression levels were observed after accounting for VO2max, age and adiposity differences. Multiple regression analysis indicates that the VO2max in mL.kg LLM−1.min−1can be predicted from the levels of SOD2, Total Nrf2 and Keap1 (R = 0.58, P < 0.001), with SOD2 being the main predictor explaining 28 % of variance in VO2max, while Nrf2 and Keap1 explained each around 3 % of the variance. SOD1 protein expression increased with ageing in the whole group after accounting for differences in VO2max and body fat percentage. Overweight and obesity were associated with increased pSer40-Nrf2, pSer40-Nrf2/Total Nrf2 ratio and SOD1 protein expression levels after accounting for differences in age and VO2max. Overall, at the population level, higher aerobic fitness is associated with increased basal expression of muscle antioxidant enzymes, which may explain some of the benefits of regular exercise.
  •  
2.
  • Galvan-Alvarez, Victor, et al. (författare)
  • Determinants of the maximal functional reserve during repeated supramaximal exercise by humans: The roles of Nrf2/Keap1, antioxidant proteins, muscle phenotype and oxygenation
  • 2023
  • Ingår i: Redox Biology. - : Elsevier B.V.. - 2213-2317. ; 66
  • Tidskriftsartikel (refereegranskat)abstract
    • When high-intensity exercise is performed until exhaustion a “functional reserve” (FR) or capacity to produce power at the same level or higher than reached at exhaustion exists at task failure, which could be related to reactive oxygen and nitrogen species (RONS)-sensing and counteracting mechanisms. Nonetheless, the magnitude of this FR remains unknown. Repeated bouts of supramaximal exercise at 120% of VO2max interspaced with 20s recovery periods with full ischaemia were used to determine the maximal FR. Then, we determined which muscle phenotypic features could account for the variability in functional reserve in humans. Exercise performance, cardiorespiratory variables, oxygen deficit, and brain and muscle oxygenation (near-infrared spectroscopy) were measured, and resting muscle biopsies were obtained from 43 young healthy adults (30 males). Males and females had similar aerobic (VO2max per kg of lower extremities lean mass (LLM): 166.7 ± 17.1 and 166.1 ± 15.6 ml kg LLM−1.min−1, P = 0.84) and anaerobic fitness (similar performance in the Wingate test and maximal accumulated oxygen deficit when normalized to LLM). The maximal FR was similar in males and females when normalized to LLM (1.84 ± 0.50 and 2.05 ± 0.59 kJ kg LLM−1, in males and females, respectively, P = 0.218). This FR depends on an obligatory component relying on a reserve in glycolytic capacity and a putative component generated by oxidative phosphorylation. The aerobic component depends on brain oxygenation and phenotypic features of the skeletal muscles implicated in calcium handling (SERCA1 and 2 protein expression), oxygen transport and diffusion (myoglobin) and redox regulation (Keap1). The glycolytic component can be predicted by the protein expression levels of pSer40-Nrf2, the maximal accumulated oxygen deficit and the protein expression levels of SOD1. Thus, an increased capacity to modulate the expression of antioxidant proteins involved in RONS handling and calcium homeostasis may be critical for performance during high-intensity exercise in humans.
  •  
3.
  • Martinez-Galvan, Eduardo, et al. (författare)
  • Film Thickness and Heat Transfer Measurements in a Spray Cooling System With R134a
  • 2011
  • Ingår i: Journal of Electronic Packaging. - : ASME International. - 1043-7398 .- 1528-9044. ; 133:1, s. 011002-
  • Tidskriftsartikel (refereegranskat)abstract
    • Experimental measurements in a spray cooling test rig have been carried out for several heat fluxes in the heater and different spray volumetric fluxes with the dielectric refrigerant R134a. Results of the heat transfer and the sprayed refrigerant film thickness measurements are presented. The film thickness measurements have been made with a high speed camera equipped with a long distance microscope. It has been found that there is a relation between the variation in the average Nusselt number and the film thickness along the spray cooling boiling curve. The heat transfer regimes along that curve are related not only with a variation in the average Nusselt number but also with changes in the film thickness. The qualitative analysis of those variations has served to understand better the heat transfer mechanisms occurring during the spray cooling.
  •  
4.
  • Martínez-Galván, Eduardo, et al. (författare)
  • Heat transfer and film thickness measurements in a closed loop spray cooling system with R134a
  • 2009
  • Ingår i: 15th International Workshop on Thermal Investigations of ICs and Systems, THERMINIC 2009. - : Academic Conferences Publishing. - 9782355000102 ; , s. 180-185
  • Konferensbidrag (refereegranskat)abstract
    • Experimental measurements in a spray cooling test rig have been carried out for different heat fluxes in the heater and different volumetric spray fluxes of the refrigerant. Results of the thermal parameters and the sprayed refrigerant liquid film thickness over the heater are presented. The film thickness measurements have been made with a high speed camera equipped with a long distance microscope. It has been found that there is a relation between the variation of the heat transfer coefficient and the film thickness along the spray boiling curve.
  •  
5.
  • Martinez-Galvan, Eduardo, et al. (författare)
  • Influence of surface roughness on a spray cooling system with R134a. Part I : Heat transfer measurements
  • 2013
  • Ingår i: Experimental Thermal and Fluid Science. - : Elsevier BV. - 0894-1777 .- 1879-2286. ; 46, s. 183-190
  • Tidskriftsartikel (refereegranskat)abstract
    • Experimental measurements in a spray cooling test rig were carried out for two different heater surface roughnesses and for two different types of nozzles with the dielectric refrigerant R134a. In this paper, results of the heat transfer measurements are presented. The analysis of the results explains the influence of the volumetric flow rate, the surface roughness and the type of nozzle (through the spray parameters) on the spray cooling boiling curve, on the Nusselt number and on the efficiency. It has been found that the effect of a smooth roughness is to delay the onset of the nucleate boiling, but once this regime has started, boiling is so fast that the CHF (Critical Heat Flux) is reached at lower heater temperatures and lower heat fluxes. In a companion paper the sprayed refrigerant film thickness measurements and its relation with the heat transfer measurements are presented.
  •  
6.
  • Martinez-Galván, Eduardo, et al. (författare)
  • Influence of surface roughness on a spray cooling system with R134a. Part II : Film thickness measurements
  • 2013
  • Ingår i: Experimental Thermal and Fluid Science. - : Elsevier. - 0894-1777 .- 1879-2286. ; 48, s. 73-80
  • Tidskriftsartikel (refereegranskat)abstract
    • Experimental measurements in a spray cooling test rig were carried out for two different heater surface roughnesses and for two different types of nozzles with the dielectric refrigerant R134a. In this paper, results of the sprayed refrigerant film thickness measurements are presented. The influence of the volumetric flow rate, the surface roughness and the type of nozzle (through the spray parameters) on the total average film thickness is analyzed and discussed. In a companion paper, results of the heat transfer measurements are presented. It has been found that there is a relation between the variations of the average Nusselt number and of the film thickness along the spray cooling boiling curve. The heat transfer regimes along that curve are related not only to a variation in the average Nusselt number but also to changes in the film thickness. The qualitative analysis of those variations served to better understand the heat transfer mechanisms occurring during the spray cooling.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy