SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Melanson M) "

Sökning: WFRF:(Melanson M)

  • Resultat 1-13 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abazov, V. M., et al. (författare)
  • The upgraded DO detector
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 565:2, s. 463-537
  • Tidskriftsartikel (refereegranskat)abstract
    • The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO.
  •  
2.
  •  
3.
  • Eisner, N. L., et al. (författare)
  • Planet Hunters Tess I: TOI 813, a subgiant hosting a transiting Saturn-sized planet on an 84-day orbit
  • 2020
  • Ingår i: Monthly Notices of the Royal Astronomical Society. - : Oxford University Press (OUP). - 0035-8711 .- 1365-2966. ; 494:1, s. 750-763
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the discovery and validation of TOI 813 b (TIC55525572b), a transiting exoplanet identified by citizen scientists in data from NASA's Transiting Exoplanet Survey Satellite (TESS) and the first planet discovered by the Planet Hunters TESS project. The host star is a bright (V = 10.3 mag) subgiant (R* = 1.94 R☉, M☉ = 1.32 M☉). It was observed almost continuously by TESS during its first year of operations, during which time four individual transit events were detected. The candidate passed all the standard light curve-based vetting checks, and ground-based follow-up spectroscopy and speckle imaging enabled us to place an upper limit of 2 MJup (99 per cent confidence) on the mass of the companion, and to statistically validate its planetary nature. Detailed modelling of the transits yields a period of 83.8911+0.0027-0.0031 d, a planet radius of 6.71 ± 0.38 R⊕ and a semimajor axis of 0.423+0031-0.037 AU. The planet's orbital period combined with the evolved nature of the host star places this object in a relatively underexplored region of parameter space. We estimate that TOI 813 b induces a reflex motion in its host star with a semi-amplitude of ∼6 m s−1, making this a promising system to measure the mass of a relatively long-period transiting planet.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Saenger, A. K., et al. (författare)
  • Multicenter analytical evaluation of a high-sensitivity troponin T assay
  • 2011
  • Ingår i: Clinica Chimica Acta. - : Elsevier BV. - 0009-8981 .- 1873-3492. ; 412:9-10, s. 748-754
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: High-sensitivity cardiac troponin assays are being introduced clinically for earlier diagnosis of acute myocardial infarction (AMI). We evaluated the analytical performance of a high-sensitivity cardiac troponin T assay (hscTnT. Roche Diagnostics) in a multicenter, international trial. Methods: Three US and 5 European sites evaluated hscTnT on the Modular (R) Analytics E170, cobas (R) 6000, Elecsys 2010, and cobas (R) e 411. Precision, accuracy, reportable range, an inter-laboratory comparison trial, and the 99th percentile of a reference population were assessed. Results: Total imprecision (CVs) were 4.6-36.8% between 3.4 and 10.3 ng/L hscTnT. Assay linearity was up to 10,000 ng/L and the limit of blank and detection were 3 and 5 ng/L, respectively. The 99th percentile reference limit was 14.2 ng/L (n = 533). No significant differences between specimen types, assay incubation time, or reagent lots existed. A substantial positive bias (76%) exists between the 4th generation and hscTnT assays at the low end of the measuring range (< 50 ng/L). hscTnT serum pool concentrations were within 2SD limits of the mean of means in the comparison trial, indicating comparable results across multiple platforms and laboratories. Conclusion: The Roche hscTnT assay conforms to guideline precision requirements and will likely identify additional patients with myocardial injury suspicious for AMI.
  •  
9.
  • Kaviani, Sepideh, et al. (författare)
  • Determining the Accuracy and Reliability of Indirect Calorimeters Utilizing the Methanol Combustion Technique
  • 2018
  • Ingår i: Nutrition in Clinical Practice. - : Wiley. - 0884-5336. ; 33:2, s. 206-216
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Several indirect calorimetry (IC) instruments are commercially available, but comparative validity and reliability data are lacking. Existing data are limited by inconsistencies in protocols, subject characteristics, or single-instrument validation comparisons. The aim of this study was to compare accuracy and reliability of metabolic carts using methanol combustion as the cross-laboratory criterion. Methods: Eight 20-minute methanol burn trials were completed on 12 metabolic carts. Respiratory exchange ratio (RER) and percent O2 and CO2 recovery were calculated. Results: For accuracy, 1 Omnical, Cosmed Quark CPET (Cosmed), and both Parvos (Parvo Medics trueOne 2400) measured all 3 variables within 2% of the true value; both DeltaTracs and the Vmax Encore System (Vmax) showed similar accuracy in measuring 1 or 2, but not all, variables. For reliability, 8 instruments were shown to be reliable, with the 2 Omnicals ranking best (coefficient of variation [CV] < 1.26%). Both Cosmeds, Parvos, DeltaTracs, 1 Jaeger Oxycon Pro (Oxycon), Max-II Metabolic Systems (Max-II), and Vmax were reliable for at least 1 variable (CV ≤ 3%). For multiple regression, humidity and amount of combusted methanol were significant predictors of RER (R2 = 0.33, P <.001). Temperature and amount of burned methanol were significant predictors of O2 recovery (R2 = 0.18, P <.001); only humidity was a predictor for CO2 recovery (R2 = 0.15, P <.001). Conclusions: Omnical, Parvo, Cosmed, and DeltaTrac had greater accuracy and reliability. The small number of instruments tested and expected differences in gas calibration variability limits the generalizability of conclusions. Finally, humidity and temperature could be modified in the laboratory to optimize IC conditions.
  •  
10.
  • Kaviani, Sepideh, et al. (författare)
  • Determining the Accuracy and Reliability of Indirect Calorimeters Utilizing the Methanol Combustion Technique
  • 2017
  • Ingår i: The FASEB Journal. - 0892-6638 .- 1530-6860. ; 31:S1
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveThere are several indirect calorimetry (IC) instruments commercially available but validity and reliability data is lacking. Site-to-site inconsistencies in protocols and subject characteristics, and comparisons to a “gold standard” instrument or method which may no longer be accurate enough, have put restraints on drawing conclusions about instruments' performance.PurposeTo compare the accuracy and reliability of different metabolic carts using the methanol combustion technique as the criterion measure.MethodsA total of eight, 20-minute methanol burn trials were completed on 12 metabolic carts (2 Cosmed Quark CPET, 2 DeltaTrac II, 2 Parvo Medics TrueOne 2400, 2 Iaeger Oxycon Pros, 2 Omnicals, a Vmax Encore, and a Max-II Metabolic System) at 11 international study sites. Methanol tests were performed at 0700, 1000, 1300, and 1600 hours on 2 consecutive days. Respiratory Exchange Ratio (RER) and percent (%) recovery of O2 and CO2 were calculated after each test.ResultsAccuracy – 1 Omnical, Cosmed, and Parvo were accurate in measuring RER and % recovery O2, while 1 DeltaTrac was also accurate for % recovery O2. The same Cosmed and Parvo, and the other DeltaTrac were accurate in measuring % recovery CO2. Reliability – 8 instruments were shown to be reliable with the two Omnicals ranking best based on the smallest coefficient of variation (CV) (all CV(s) 1.26%). Both Cosmeds, Parvos, DeltaTracs and 1 Vmax were the reliable instruments for at least one variable (CV(s) 3%). Multiple Regression– Humidity, amount of methanol combusted, and temperature were tested as predictors of IC outcomes. Humidity and amount of combusted methanol were significant predictors of RER (F (2, 60) =10.91, p<0.001, R2=0.33). Temperature and amount of burned methanol were significant predictors of % recovery O2 (F (2, 60) =8.32, p<0.001, R2=0.18) while only humidity was a predictor for % recovery CO2 (F (1, 61) =21.10, p<0.001, R2=0.15).ConclusionOmnical, Cosmed, and Parvo showed superior accuracy and reliability; however, accuracy was only found at one of two study sites. Exogenous factors such as humidity and temperature may be influencing instrument performance and could be modified in the lab to optimize IC conditions.
  •  
11.
  •  
12.
  • Laurenius, Anna, et al. (författare)
  • Changes in eating behaviour and meal pattern following Roux-en-Y gastric bypass.
  • 2012
  • Ingår i: International journal of obesity. - : Springer Science and Business Media LLC. - 1476-5497 .- 0307-0565. ; 36:3, s. 348-355
  • Tidskriftsartikel (refereegranskat)abstract
    • Background:Little is known about eating behaviour and meal pattern subsequent to Roux-en-Y gastric bypass (RYGB), knowledge important for the nutritional care process. The objective of the study was to obtain basic information of how meal size, eating rate, meal frequency and eating behaviour change upon the RYGB surgery.Materials and methods:Voluntary chosen meal size and eating rate were measured in a longitudinal, within subject, cohort study of 43 patients, 31 women and 12 men, age 42.6 (s.d. 9.7) years, body mass index (BMI) 44.5 (4.9) kgm(-2). Thirty-one non-obese subjects, 37.8 (13.6) years, BMI 23.7 (2.7) kgm(-2) served as a reference group. All subjects completed a meal pattern questionnaire and the Three-Factor Eating Questionnaire (TFEQ-R21).Results:Six weeks postoperatively meal size was 42% of the preoperative meal size, (P<0.001). After 1 and 2 years, meal size increased but was still lower than preoperative size 57% (P<0.001) and 66% (P<0.001), respectively. Mean meal duration was constant before and after surgery. Mean eating rate measured as amount consumed food per minute was 45% of preoperative eating rate 6 weeks postoperatively (P<0.001). After 1 and 2 years, eating rate increased to 65% (P<0.001) and 72% (P<0.001), respectively, of preoperative rate. Number of meals per day increased from 4.9 (95% confidence interval, 4.4,5.4) preoperatively to 6 weeks: 5.2 (4.9,5.6), (not significant), 1 year 5.8 (5.5,6.1), (P=0.003), and 2 years 5.4 (5.1,5.7), (not significant). Emotional and uncontrolled eating were significantly decreased postoperatively, (both P<0.001 at all-time points), while cognitive restraint was only transiently increased 6 weeks postoperatively (P=0.011).Conclusions:Subsequent to RYGB, patients display markedly changed eating behaviour and meal patterns, which may lead to sustained weight loss.International Journal of Obesity advance online publication, 29 November 2011; doi:10.1038/ijo.2011.217.
  •  
13.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-13 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy