SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mendes Bernardo C.) "

Sökning: WFRF:(Mendes Bernardo C.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Dias, N., et al. (författare)
  • Outcomes of Elective and Non-elective Fenestrated-branched Endovascular Aortic Repair for Treatment of Thoracoabdominal Aortic Aneurysms
  • 2023
  • Ingår i: Annals of Surgery. - : Lippincott Williams & Wilkins. - 0003-4932 .- 1528-1140. ; 278:4, s. 568-577, s. 568-577
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs).Background: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described.Methods: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair.Results: A total of 2603 patients (69% males; mean age 72 +/- 10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P < 0.001) and rates of MAEs (34% vs 20%, P < 0.001). Median follow-up was 15 months ( interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50 +/- 4% vs 70 +/- 1% and 21 +/- 3% vs 7 +/- 1%, P < 0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality ( hazard ratio, 1.92; 95% CI] 1.50-2.44; P < 0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P < 0.001).Conclusions: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.
  •  
4.
  • Dias-Neto, Marina, et al. (författare)
  • Comparison of single- and multistage strategies during fenestrated-branched endovascular aortic repair of thoracoabdominal aortic aneurysms
  • 2023
  • Ingår i: Journal of Vascular Surgery. - : MOSBY-ELSEVIER. - 0741-5214 .- 1097-6809. ; 77:6, s. 1588-1597
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs).Methods: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single-or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality.Results: A total of 1947 patients (65% male; mean age, 71 +/- 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9 +/- 1.3% vs 79.6 +/- 1.7%) and 3 years (72.7 +/- 2.1% vs 64.2 +/- 2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach.Conclusions: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years.
  •  
5.
  • Eriksson, Kimmo, et al. (författare)
  • Perceptions of the appropriate response to norm violation in 57 societies
  • 2021
  • Ingår i: Nature Communications. - : Nature Research. - 2041-1723. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Norm enforcement may be important for resolving conflicts and promoting cooperation. However, little is known about how preferred responses to norm violations vary across cultures and across domains. In a preregistered study of 57 countries (using convenience samples of 22,863 students and non-students), we measured perceptions of the appropriateness of various responses to a violation of a cooperative norm and to atypical social behaviors. Our findings highlight both cultural universals and cultural variation. We find a universal negative relation between appropriateness ratings of norm violations and appropriateness ratings of responses in the form of confrontation, social ostracism and gossip. Moreover, we find the country variation in the appropriateness of sanctions to be consistent across different norm violations but not across different sanctions. Specifically, in those countries where use of physical confrontation and social ostracism is rated as less appropriate, gossip is rated as more appropriate. Little is known about peoples preferred responses to norm violations across countries. Here, in a study of 57 countries, the authors highlight cultural similarities and differences in peoples perception of the appropriateness of norm violations.
  •  
6.
  • Monteiro, Bernardo, et al. (författare)
  • Lanthanide-based complexes as efficient physiological temperature sensors
  • 2022
  • Ingår i: Materials Chemistry and Physics. - : Elsevier BV. - 0254-0584 .- 1879-3312. ; 277
  • Tidskriftsartikel (refereegranskat)abstract
    • A new molecular thermometric sensor based on the terbium(III) complex [C(2)mim][Tb(fod)4] (C(2)mim - 1-methyl-3-ethylimidazolium, fod(-) - tetrakis-6,6,7,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octanedionate),doped with 0.015% of its europium(III) analogue (1, [C(2)mim][Tb(fod)(4)]0.99985:[C(2)mim][Eu(fod)(4)]0.00015), was prepared and its thermochromic behaviour evaluated from ambient temperature up to 75 degrees C, including in the physiological range (35-45 degrees C). It was found that the intensity ratio of the D-5(4)-> F-7(5) (TbIII) and D-5(0)-> F-7(2) (EuIII) transitions is correlated with temperature having three different linear regimes. Visual colorimetry allowed the evaluation of the temperature in different ranges from green at ambient temperature, to yellow and finally red at higher temperatures. The TbIII complex emission intensity is extremely sensitive to small temperature variations, particularly between 25 and 35 degrees C, were it reaches only 40% of the initial intensity. Confinement of the dopped TbIII tetrakis-complex in the organic polymeric matrix poly(methylmethacrylate) (PMMA) induced higher thermal stability in 1, together with a strong temperature dependence of the most intense emissive transition of the TbIII complexes. The photoluminescence quantum yield of polymer-lanthanide hybrid materials increased significantly compared with that of 1. Under 366 nm irradiation, the hybrid material presents a green colour at 25 degrees C that evolves to yellow at 30 degrees C and to a white tone at 35 degrees C.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy