SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Minarik J) "

Sökning: WFRF:(Minarik J)

  • Resultat 1-11 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ballantyne, Kaye N., et al. (författare)
  • Toward Male Individualization with Rapidly Mutating Y-Chromosomal Short Tandem Repeats
  • 2014
  • Ingår i: Human Mutation. - : John Wiley & Sons. - 1059-7794 .- 1098-1004. ; 35:8, s. 1021-1032
  • Tidskriftsartikel (refereegranskat)abstract
    • Relevant for various areas of human genetics, Y-chromosomal short tandem repeats (Y-STRs) are commonly used for testing close paternal relationships among individuals and populations, and for male lineage identification. However, even the widely used 17-loci Yfiler set cannot resolve individuals and populations completely. Here, 52 centers generated quality-controlled data of 13 rapidly mutating (RM) Y-STRs in 14,644 related and unrelated males from 111 worldwide populations. Strikingly, greater than99% of the 12,272 unrelated males were completely individualized. Haplotype diversity was extremely high (global: 0.9999985, regional: 0.99836-0.9999988). Haplotype sharing between populations was almost absent except for six (0.05%) of the 12,156 haplotypes. Haplotype sharing within populations was generally rare (0.8% nonunique haplotypes), significantly lower in urban (0.9%) than rural (2.1%) and highest in endogamous groups (14.3%). Analysis of molecular variance revealed 99.98% of variation within populations, 0.018% among populations within groups, and 0.002% among groups. Of the 2,372 newly and 156 previously typed male relative pairs, 29% were differentiated including 27% of the 2,378 father-son pairs. Relative to Yfiler, haplotype diversity was increased in 86% of the populations tested and overall male relative differentiation was raised by 23.5%. Our study demonstrates the value of RMY-STRs in identifying and separating unrelated and related males and provides a reference database.
  •  
2.
  • Anand, Aseem, et al. (författare)
  • A preanalytic validation study of automated bone scan index : Effect on accuracy and reproducibility due to the procedural variabilities in bone scan image acquisition
  • 2016
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 2159-662X. ; 57:12, s. 1865-1871
  • Tidskriftsartikel (refereegranskat)abstract
    • The effect of the procedural variability in image acquisition on the quantitative assessment of bone scan is unknown. Here, we have developed and performed preanalytical studies to assess the impact of the variability in scanning speed and in vendor-specific γ-camera on reproducibility and accuracy of the automated bone scan index (BSI). Methods: Two separate preanalytical studies were performed: a patient study and a simulation study. In the patient study, to evaluate the effect on BSI reproducibility, repeated bone scans were prospectively obtained from metastatic prostate cancer patients enrolled in 3 groups (Grp). In Grp1, the repeated scan speed and the γ-camera vendor were the same as that of the original scan. In Grp2, the repeated scan was twice the speed of the original scan. In Grp3, the repeated scan used a different γ-camera vendor than that used in the original scan. In the simulation study, to evaluate the effect on BSI accuracy, bone scans of a virtual phantom with predefined skeletal tumor burden (phantom-BSI) were simulated against the range of image counts (0.2, 0.5, 1.0, and 1.5 million) and separately against the resolution settings of the γ-cameras. The automated BSI was measured with a computer-automated platform. Reproducibility was measured as the absolute difference between the repeated BSI values, and accuracy was measured as the absolute difference between the observed BSI and the phantom-BSI values. Descriptive statistics were used to compare the generated data. Results: In the patient study, 75 patients, 25 in each group, were enrolled. The reproducibility of Grp2 (mean ± SD, 0.35 ± 0.59) was observed to be significantly lower than that of Grp1 (mean ± SD, 0.10 ± 0.13; P < 0.0001) and that of Grp3 (mean ± SD, 0.09 ± 0.10; P < 0.0001). However, no significant difference was observed between the reproducibility of Grp3 and Grp1 (P = 0.388). In the simulation study, the accuracy at 0.5 million counts (mean ± SD, 0.57 ± 0.38) and at 0.2 million counts (mean ± SD, 4.67 ± 0.85) was significantly lower than that observed at 1.5 million counts (mean ± SD, 0.20 ± 0.26; P < 0.0001). No significant difference was observed in the accuracy data of the simulation study with vendor-specific γ-cameras (P 5 0.266). Conclusion: In this study, we observed that the automated BSI accuracy and reproducibility were dependent on scanning speed but not on the vendor-specific γ-cameras. Prospective BSI studies should standardize scanning speed of bone scans to obtain image counts at or above 1.5 million.
  •  
3.
  •  
4.
  • Anand, Aseem, et al. (författare)
  • Automated Bone Scan Index as a quantitative imaging biomarker in metastatic castration-resistant prostate cancer patients being treated with enzalutamide
  • 2016
  • Ingår i: EJNMMI Research. - : Springer. - 2191-219X. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Having performed analytical validation studies, we are now assessing the clinical utility of the upgraded automated Bone Scan Index (BSI) in metastatic castration-resistant prostate cancer (mCRPC). In the present study, we retrospectively evaluated the discriminatory strength of the automated BSI in predicting overall survival (OS) in mCRPC patients being treated with enzalutamide.METHODS: Retrospectively, we included patients who received enzalutamide as a clinically approved therapy for mCRPC and had undergone bone scan prior to starting therapy. Automated BSI, prostate-specific antigen (PSA), hemoglobin (HgB), and alkaline phosphatase (ALP) were obtained at baseline. Change in automated BSI and PSA were obtained from patients who have had bone scan at week 12 of treatment follow-up. Automated BSI was obtained using the analytically validated EXINI Bone(BSI) version 2. Kendall's tau (τ) was used to assess the correlation of BSI with other blood-based biomarkers. Concordance index (C-index) was used to evaluate the discriminating strength of automated BSI in predicting OS.RESULTS: Eighty mCRPC patients with baseline bone scans were included in the study. There was a weak correlation of automated BSI with PSA (τ = 0.30), with HgB (τ = -0.17), and with ALP (τ = 0.56). At baseline, the automated BSI was observed to be predictive of OS (C-index 0.72, standard error (SE) 0.03). Adding automated BSI to the blood-based model significantly improved the C-index from 0.67 to 0.72, p = 0.017. Treatment follow-up bone scans were available from 62 patients. Both change in BSI and percent change in PSA were predictive of OS. However, the combined predictive model of percent PSA change and change in automated BSI (C-index 0.77) was significantly higher than that of percent PSA change alone (C-index 0.73), p = 0.041.CONCLUSIONS: The upgraded and analytically validated automated BSI was found to be a strong predictor of OS in mCRPC patients. Additionally, the change in automated BSI demonstrated an additive clinical value to the change in PSA in mCRPC patients being treated with enzalutamide.
  •  
5.
  •  
6.
  • Nakajima, K., et al. (författare)
  • Improved quantification of small hearts for gated myocardial perfusion imaging
  • 2013
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 40:8, s. 1163-1170
  • Tidskriftsartikel (refereegranskat)abstract
    • In patients with a small heart, defined as an end-systolic volume (ESV) of a parts per thousand currency sign20 mL calculated using the Quantitative Gated SPECT (QGS) program, underestimation of ESV and overestimation of ejection fraction (EF) using gated myocardial perfusion imaging are considered errors caused by inappropriate delineation of the left ventricle (LV). The aim of this study was to develop a new method for delineation of the LV and to evaluate it in studies using a digital phantom, normal subjects and patients. The active shape-based method for LV delineation, EXINI heart (ExH), was adjusted to more accurately process small hearts. In small hearts, due to the partial volume effect and the short distance to the opposite ventricular wall, the endocardial and the epicardial surfaces are shifted in the epicardial direction depending on the midventricular volume. The adjusted method was evaluated using digital XCAT phantoms with Monte Carlo simulation (8 virtual patients), a Japanese multicentre normal database (69 patients) and consecutive Japanese patients (116 patients). The LV volumes, EF and diastolic parameters derived from ExH and QGS were compared. The digital phantom studies showed a mean ESV of 87 % +/- 9 % of the true volume calculated using ExH and 22 % +/- 18 % calculated using QGS. In the normal database, QGS gave higher EFs in women than in men (71.4 +/- 6.0 % vs. 67.2 +/- 6.0 %, p = 0.0058), but ExH gave comparable EFs (70.7 +/- 4.9 % and 71.4 +/- 5 % in men and women, respectively, p = ns). QGS gave higher EFs in subjects with a small heart than in those with a normal-sized heart (74.5 +/- 5.1 % vs. 66.1 +/- 4.9 %), but ExH gave comparable values (70.0 +/- 5.9 % vs. 71.6 +/- 4.2 %, respectively, p = ns). In consecutive patients, the average EFs with QGS in patients with ESV > 20 mL, 11-20 mL and a parts per thousand currency sign10 mL were 57.9 %, 71.9 % and 83.2 %, but with ExH the differences among these groups were smaller (65.2 %, 67.8 % and 71.5 %, respectively). The volume-dependent edge correction algorithm was able to effectively reduce the effects on ESV and EF of a small heart. The uniform normal values might be applicable to both men and women and to both small and normal-sized hearts.
  •  
7.
  • Ray-Coquard, I., et al. (författare)
  • Final results from GCIG/ENGOT/AGO-OVAR 12, a randomised placebo-controlled phase III trial of nintedanib combined with chemotherapy for newly diagnosed advanced ovarian cancer
  • 2020
  • Ingår i: International Journal of Cancer. - : John Wiley & Sons. - 0020-7136 .- 1097-0215. ; 146:2, s. 439-448
  • Tidskriftsartikel (refereegranskat)abstract
    • AGO-OVAR 12 investigated the effect of adding the oral triple angiokinase inhibitor nintedanib to standard front-line chemotherapy for advanced ovarian cancer. At the primary analysis, nintedanib demonstrated significantly improved progression-free survival (PFS; primary endpoint) compared with placebo. We report final results, including overall survival (OS). Patients with primary debulked International Federation of Gynaecology and Obstetrics (FIGO) stage IIB–IV newly diagnosed ovarian cancer were randomised 2:1 to receive carboplatin (area under the curve 5 or 6) plus paclitaxel (175 mg/m2) on day 1 every 3 weeks for six cycles combined with either nintedanib 200 mg or placebo twice daily on days 2–21 every 3 weeks for up to 120 weeks. Between December 2009 and July 2011, 1,366 patients were randomised (911 to nintedanib, 455 to placebo). Disease was considered as high risk (FIGO stage III with amp;gt;1 cm residuum, or any stage IV) in 39%. At the final analysis, 605 patients (44%) had died. There was no difference in OS (hazard ratio 0.99, 95% confidence interval [CI] 0.83–1.17, p = 0.86; median 62.0 months with nintedanib vs. 62.8 months with placebo). Subgroup analyses according to stratification factors, clinical characteristics and risk status showed no OS difference between treatments. The previously reported PFS improvement seen with nintedanib did not translate into an OS benefit in the nonhigh-risk subgroup. Updated PFS results were consistent with the primary analysis (hazard ratio 0.86, 95% CI 0.75–0.98; p = 0.029) favouring nintedanib. The safety profile was consistent with previous reports. © 2019 UICC
  •  
8.
  •  
9.
  •  
10.
  •  
11.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-11 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy