1.
  • Vatnitsky, S, et al. (författare)
  • Proton dosimetry intercomparison based on the ICRU report 59 protocol
  • 1999
  • Ingår i: Radiotherapy and Oncology. - 0167-8140 .- 1879-0887. ; 51:3, s. 273-279
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE:A new protocol for calibration of proton beams was established by the ICRU in report 59 on proton dosimetry. In this paper we report the results of an international proton dosimetry intercomparison, which was held at Loma Linda University Medical Center. The goals of the intercomparison were, first, to estimate the level of consistency in absorbed dose delivered to patients if proton beams at various clinics were calibrated with the new ICRU protocol, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration factors.MATERIALS AND METHODS:Eleven institutions participated in the intercomparison. Measurements were performed in a polystyrene phantom at a depth of 10.27 cm water equivalent thickness in a 6-cm modulated proton beam with an accelerator energy of 155 MeV and an incident energy of approximately 135 MeV. Most participants used ionization chambers calibrated in terms of exposure or air kerma. Four ionization chambers had 60Co-based calibration in terms of absorbed dose-to-water. Two chambers were calibrated in a 60Co beam at the NIST both in terms of air kerma and absorbed dose-to-water to provide a comparison of ionization chambers with different calibrations.RESULTS:The intercomparison showed that use of the ICRU report 59 protocol would result in absorbed doses being delivered to patients at their participating institutions to within +/-0.9% (one standard deviation). The maximum difference between doses determined by the participants was found to be 2.9%. Differences between proton doses derived from the measurements with ionization chambers with N(K)-, or N(W) - calibration type depended on chamber type.CONCLUSIONS:Using ionization chambers with 60Co calibration factors traceable to standard laboratories and the ICRU report 59 protocol, a distribution of stated proton absorbed dose is achieved with a difference less than 3%. The ICRU protocol should be adopted for clinical proton beam calibration. A comparison of proton doses derived from measurements with different chambers indicates that the difference in results cannot be explained only by differences in 60Co calibration factors.
  •  
2.
  • Pachnerova Brabcová, Katerina, 1978, et al. (författare)
  • Dose Distribution Outside the Target Volume for 170-Mev Proton Beam
  • 2014
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 161:1-4, s. 410-416
  • Tidskriftsartikel (refereegranskat)abstract
    • Dose delivered outside the proton field during radiotherapy can potentially lead to secondary cancer development. Measurements with a 170-MeV proton beam were performed with passive detectors (track etched detectors and thermoluminescence dose-meters) in three different depths along the Bragg curve. The measurement showed an uneven decrease of the dose outside of the beam field with local enhancements. The major contribution to the delivered dose is due to high-energy protons with linear energy transfer (LET) up to 10 keV mu m(-1). However, both measurement and preliminary Monte Carlo calculation also confirmed the presence of particles with higher LET.
  •  
3.
  • Ploc, Ondrej, et al. (författare)
  • Poster session 11: Space dosimetry and environment dosimetry measurements using timepix in mixed radiation fields induced by heavy ions; comparison with standard dosimetry methods
  • 2014
  • Ingår i: Journal of Radiation Research. - : Oxford University Press (OUP). - 0449-3060 .- 1349-9157. ; 55, s. i141-i142
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective of our research was to explore capabilities of Timepix for its use as a single dosemeter and LET spectrometer in mixed radiation fields created by heavy ions. We exposed it to radiation field (i) at heavy ion beams at HIMAC, Chiba, Japan, (ii) in the CERN's high-energy reference field (CERF) facility at Geneva, France/Switzerland, (iii) in the exposure room of the proton therapy laboratory at JINR, Dubna, Russia, and (iv) onboard aircraft. We compared the absolute values of dosimetric quantities obtained with Timepix and with other dosemeters and spectrometers like tissue-equivalent proportional counter (TEPC) Hawk, silicon detector Liulin, and track-etched detectors (TEDs). © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology.
  •  