SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Moutinho Ribeiro P.) "

Sökning: WFRF:(Moutinho Ribeiro P.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Soares, J. B., et al. (författare)
  • Interobserver agreement of EUS elastography in the evaluation of solid pancreatic lesions
  • 2015
  • Ingår i: Endoscopic Ultrasound. - : Medknow. - 2303-9027. ; 4:3, s. 244-249
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Objectives: Previous reports assessing the reproducibility of endoscopic ultrasound elastography (EUS-E) in evaluation of solid pancreatic lesions (SPL) involved only experienced endosonographers. We aimed to assess the interobserver agreement (IOA) of EUS-E in the evaluation of SPL by endoscopists with different levels of experience in EUS and EUS-E. Materials and Methods: A cross-sectional observational multicenter study was designed and included 11 endoscopists who were divided into four groups: Group A (long experience in EUS and EUS-E); Group B (short experience in EUS and EUS-E); Group C (long experience in EUS and no experience in EUS-E); and Group D (no experience in EUS or EUS-E). The observers independently classified the patterns of 60 video sequences of EUS-E, after a 20-min training session. For each group, we calculated IOA (kappa statistic, k) of EUS-E and the diagnostic accuracy of EUS-E for pancreatic malignancy, by comparing the pattern of EUS-E indicative of malignancy (heterogeneous or homogenous blue) with the final diagnosis. Results: The overall IOA was moderate (k = 0.42; 95% confidence interval (CI) 0.33-0.52). The IOA of Group A (k = 0.80; 95% CI 0.65-1.00) was significantly higher than that of Groups B (k = 0.54; 95% CI 0.40-0.71), C (k = 0.54; 95% CI 0.39-0.68), and D (k = 0.28; 95% CI 0.14-0.40). IOA of Groups B and C was not significantly different, but it was significantly higher than that of Group D. The diagnostic accuracy of Group A (area under the curve under summary receiver operating characteristic (AUROC) = 0.83; 95% CI 0.75-0.90) was not significantly different from that of Group B (AUROC = 0.77; 95% CI 0.71-0.83), but it was significantly higher than that of Groups C (AUROC = 0.74; 95% CI 0.67-0.81) and D (AUROC = 0.74; 95% CI 0.67-0.81). No significant difference was seen between Groups B, C, and D for diagnostic accuracy. Conclusion: EUS-E is reproducible in the evaluation of SPL, even between endoscopists with no or limited experience in EUS and/or EUS-E. Reproducibility and diagnostic accuracy increase with experience in EUS and EUS-E.
  •  
2.
  •  
3.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy