SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Nagler B.) "

Sökning: WFRF:(Nagler B.)

  • Resultat 1-46 av 46
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • 2019
  • Tidskriftsartikel (refereegranskat)
  •  
2.
  •  
3.
  • Seiboth, F., et al. (författare)
  • Focusing XFEL SASE pulses by rotationally parabolic refractive x-ray lenses
  • 2014
  • Ingår i: Journal of Physics, Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 499:1, s. 012004-
  • Tidskriftsartikel (refereegranskat)abstract
    • Using rotationally parabolic refractive x-ray lenses made of beryllium, we focus hard x-ray free-electron laser pulses of the Linac Coherent Light Source (LCLS) down to a spot size in the 100 nm range. We demonstrated efficient nanofocusing and characterized the nanofocused wave field by ptychographic imaging [A. Schropp, et al., Sci. Rep. 3, 1633 (2013)] in the case of monochromatic LCLS pulses produced by a crystal monochromator that decreases the LCLS bandwidth down to ΔE/E 1.4 · 10-4. The full spectrum of LCLS pulses generated by self-amplified spontaneous emission (SASE), however, fluctuates and has a typical bandwidth of a few per mille (ΔE/E 2 · 10-3). Due to the dispersion in the lens material, a polychromatic nanobeam generated by refractive x-ray lenses is affected by chromatic aberration. After reviewing the chromaticity of refractive x-ray lenses, we discuss the influence of increased bandwidth on the quality of a nanofocused SASE pulse.
  •  
4.
  •  
5.
  • Hajkova, V., et al. (författare)
  • X-ray laser-induced ablation of lead compounds
  • 2011
  • Ingår i: DAMAGE TO VUV, EUV, AND X-RAY OPTICS III. - : SPIE.
  • Konferensbidrag (refereegranskat)abstract
    • The recent commissioning of a X-ray free-electron laser triggered an extensive research in the area of X-ray ablation of high-Z, high-density materials. Such compounds should be used to shorten an effective attenuation length for obtaining clean ablation imprints required for the focused beam analysis. Compounds of lead (Z=82) represent the materials of first choice. In this contribution, single-shot ablation thresholds are reported for PbWO(4) and PbI(2) exposed to ultra-short pulses of extreme ultraviolet radiation and X-rays at FLASH and LCLS facilities, respectively. Interestingly, the threshold reaches only 0.11 J/cm(2) at 1.55 nm in lead tungstate although a value of 0.4 J/cm(2) is expected according to the wavelength dependence of an attenuation length and the threshold value determined in the XUV spectral region, i.e., 79 mJ/cm(2) at a FEL wavelength of 13.5 nm. Mechanisms of ablation processes are discussed to explain this discrepancy. Lead iodide shows at 1.55 nm significantly lower ablation threshold than tungstate although an attenuation length of the radiation is in both materials quite the same. Lower thermal and radiation stability of PbI(2) is responsible for this finding.
  •  
6.
  • Hoppe, R., et al. (författare)
  • Full characterization of a focused wavefield with sub 100 nm resolution
  • 2013
  • Ingår i: Advances In X-Ray Free-Electron Lasers II. - : SPIE - International Society for Optical Engineering. - 9780819495808 ; , s. 87780G-
  • Konferensbidrag (refereegranskat)abstract
    • A hard x-ray free-electron laser (XFEL) provides an x-ray source with an extraordinary high peak-brilliance, a time structure with extremely short pulses and with a large degree of coherence, opening the door to new scientific fields. Many XFEL experiments require the x-ray beam to be focused to nanometer dimensions or, at least, benefit from such a focused beam. A detailed knowledge about the illuminating beam helps to interpret the measurements or is even inevitable to make full use of the focused beam. In this paper we report on focusing an XFEL beam to a transverse size of 125nm and how we applied ptychographic imaging to measure the complex wavefield in the focal plane in terms of phase and amplitude. Propagating the wavefield back and forth we are able to reconstruct the full caustic of the beam, revealing aberrations of the nano-focusing optic. By this method we not only obtain the averaged illumination but also the wavefield of individual XFEL pulses.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  •  
11.
  • Vinko, S. M., et al. (författare)
  • Electronic Structure of an XUV Photogenerated Solid-Density Aluminum Plasma
  • 2010
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 104:22, s. 225001-
  • Tidskriftsartikel (refereegranskat)abstract
    • By use of high intensity XUV radiation from the FLASH free-electron laser at DESY, we have created highly excited exotic states of matter in solid-density aluminum samples. The XUV intensity is sufficiently high to excite an inner-shell electron from a large fraction of the atoms in the focal region. We show that soft-x-ray emission spectroscopy measurements reveal the electronic temperature and density of this highly excited system immediately after the excitation pulse, with detailed calculations of the electronic structure, based on finite-temperature density functional theory, in good agreement with the experimental results.
  •  
12.
  • Zhou, Zheng, et al. (författare)
  • Reduced intensity conditioning for acute myeloid leukemia using melphalan- vs busulfan-based regimens : a CIBMTR report
  • 2020
  • Ingår i: Blood Advances. - : American Society of Hematology. - 2473-9529 .- 2473-9537. ; 4:13, s. 3180-3190
  • Tidskriftsartikel (refereegranskat)abstract
    • There is a lack of large comparative study on the outcomes of reduced intensity conditioning (RIC) in acute myeloid leukemia (AML) transplantation using fludarabine/busulfan (FB) and fludarabine/melphalan (FM) regimens. Adult AML patients from Center for International Blood and Marrow Transplant Research who received first RIC allo-transplant between 2001 and 2015 were studied. Patients were excluded if they received cord blood or identical twin transplant, total body irradiation in conditioning, or graft-versus-host disease (GVHD) prophylaxis with in vitro T-cell depletion. Primary outcome was overall survival (OS), secondary end points were leukemia-free survival (LFS), nonrelapse mortality (NRM), relapse, and GVHD. Multivariate survival model was used with adjustment for patient, leukemia, and transplant-related factors. A total of 622 patients received FM and 791 received FB RIC. Compared with FB, the FM group had fewer transplant in complete remission (CR), fewer matched sibling donors, and less usage of anti-thymocyte globulin or alemtuzumab. More patients in the FM group received marrow grafts and had transplantation before 2005. OS was significantly lower within the first 3 months posttransplant in the FM group (hazard ratio [HR] = 1.82, P < .001), but was marginally superior beyond 3 months (HR = 0.87, P = .05). LFS was better with FM compared with FB (HR = 0.89, P = .05). NRM was significantly increased in the FM group during the first 3 months of posttransplant (HR = 3.85, P < .001). Long-term relapse was lower with FM (HR = 0.65, P < .001). Analysis restricted to patients with CR showed comparable results. In conclusion, compared with FB, the FM RIC showed a marginally superior long-term OS and LFS and a lower relapse rate. A lower OS early posttransplant within 3 months was largely the result of a higher early NRM.
  •  
13.
  • Andreasson, Jakob, et al. (författare)
  • Saturated ablation in metal hydrides and acceleration of protons and deuterons to keV energies with a soft-x-ray laser
  • 2011
  • Ingår i: Physical Review E. Statistical, Nonlinear, and Soft Matter Physics. - 1539-3755 .- 1550-2376. ; 83:1, s. 016403-
  • Tidskriftsartikel (refereegranskat)abstract
    • Studies of materials under extreme conditions have relevance to a broad area of research, including planetary physics, fusion research, materials science, and structural biology with x-ray lasers. We study such extreme conditions and experimentally probe the interaction between ultrashort soft x-ray pulses and solid targets (metals and their deuterides) at the FLASH free-electron laser where power densities exceeding 1017 W/cm2 were reached. Time-of-flight ion spectrometry and crater analysis were used to characterize the interaction. The results show the onset of saturation in the ablation process at power densities above 1016 W/cm2. This effect can be linked to a transiently induced x-ray transparency in the solid by the femtosecond x-ray pulse at high power densities. The measured kinetic energies of protons and deuterons ejected from the surface reach several keV and concur with predictions from plasma-expansion models. Simulations of the interactions were performed with a nonlocal thermodynamic equilibrium code with radiation transfer. These calculations return critical depths similar to the observed crater depths and capture the transient surface transparency at higher power densities.
  •  
14.
  •  
15.
  •  
16.
  •  
17.
  • Crawley, C, et al. (författare)
  • Outcomes for reduced-intensity allogeneic transplantation for multiple myeloma: an analysis of prognostic factors from the Chronic Leukaemia Working Party of the EBMT
  • 2005
  • Ingår i: Blood. - : American Society of Hematology. - 1528-0020 .- 0006-4971. ; 105:11, s. 4532-4539
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the outcome of 229 patients who received an allograft for myeloma with reduced-intensity conditioning (RIC) regimens from 33 centers within the European Group for Blood and Marrow Transplantation (EBMT). The median age was 52 years and 64% were male. Conditioning regimens were heterogeneous, but most were fludarabine based and T cell depleted with antithymocyte globulin or alemtuzumab. Transplantation-related mortality (TRIM) at 1 year was 22%. The 3-year overall survival (OS) and progression-free survival (PFS) were 41% and 21 %, respectively. Adverse OS was associated with chemoresistant disease (relative risk [RR], 2.9), more than 1 prior transplantation (RR, 2.0), and male patients with female donors (FIR, 1.45). Adverse PFS was associated with chemoresistance (RR, 2.4) and alemtuzumab (RR, 1.8). TRM was increased with female-to-male donation (RR, 2.5) and transplantation more than 1 year from diagnosis (RR, 2.3). Grades II to IV acute graft-versus-host disease (aGvHD) occurred in 31%. Chronic GvHD was associated with better OS and PFS and were 84% and 46% for limited, 58% and 30% for extensive, and 29% and 12% in its absence suggesting that a graft-versus-myeloma effect is important. While RIC is feasible, heavily pretreated patients and patients with progressive disease do not benefit.
  •  
18.
  •  
19.
  •  
20.
  •  
21.
  •  
22.
  • Iwan, Bianca S, et al. (författare)
  • TOF-OFF : A method for determining focal positions in tightly focused free-electron laser experiments by measurement of ejected ions
  • 2011
  • Ingår i: High Energy Density Physics. - : Elsevier BV. - 1574-1818. ; 7:4, s. 336-342
  • Tidskriftsartikel (refereegranskat)abstract
    • Pulse intensities greater than 1017 Watt/cm2 were reached at the FLASH soft X-ray laser in Hamburg, Germany, using an off-axis parabolic mirror to focus 15 fs pulses of 5–70 μJ energy at 13.5 nm wavelength to a micron-sized spot. We describe the interaction of such pulses with niobium and vanadium targets and their deuterides. The beam produced craters in the solid targets, and we measured the kinetic energy of ions ejected from these craters. Ions with several keV kinetic energy were observed from craters approaching 5 μm in depth when the sample was at best focus. We also observed the onset of saturation in both ion acceleration and ablation with pulse intensities exceeding 1016 W/cm2, when the highest detected ion energies and the crater depths tend to saturate with increasing intensity. A general difficulty in working with micron and sub-micron focusing optics is finding the exact focus of the beam inside a vacuum chamber. Here we propose a direct method to measure the focal position to a resolution better than the Rayleigh length. The method is based on the correlation between the energies of ejected ions and the physical dimensions of the craters. We find that the focus position can be quickly determined from the ion time-of-flight (TOF) data as the target is scanned through the expected focal region. The method does not require external access to the sample or venting the vacuum chamber. Profile fitting employed to analyze the TOF data can extend resolution beyond the actual scanning step size.
  •  
23.
  •  
24.
  • Levis, Mark, et al. (författare)
  • Results from a randomized trial of salvage chemotherapy followed by lestaurtinib for patients with FLT3 mutant AML in first relapse
  • 2011
  • Ingår i: Blood. - : American Society of Hematology. - 1528-0020 .- 0006-4971. ; 117:12, s. 3294-3301
  • Tidskriftsartikel (refereegranskat)abstract
    • In a randomized trial of therapy for FMS-like tyrosine kinase-3 (FLT3) mutant acute myeloid leukemia in first relapse, 224 patients received chemotherapy alone or followed by 80 mg of the FLT3 inhibitor lestaurtinib twice daily. Endpoints included complete remission or complete remission with incomplete platelet recovery (CR/CRp), overall survival, safety, and tolerability. Correlative studies included pharmacokinetics and analysis of in vivo FLT3 inhibition. There were 29 patients with CR/CRp in the lestaurtinib arm and 23 in the control arm (26% vs 21%; P = .35), and no difference in overall survival between the 2 arms. There was evidence of toxicity in the lestaurtinib-treated patients, particularly those with plasma levels in excess of 20 mu M. In the lestaurtinib arm, FLT3 inhibition was highly correlated with remission rate, but target inhibition on day 15 was achieved in only 58% of patients receiving lestaurtinib. Given that such a small proportion of patients on this trial achieved sustained FLT3 inhibition in vivo, any conclusions regarding the efficacy of combining FLT3 inhibition with chemotherapy are limited. Overall, lestaurtinib treatment after chemotherapy did not increase response rates or prolong survival of patients with FLT3 mutant acute myeloid leukemia in first relapse. This study is registered at www.clinicaltrials.gov as #NCT00079482. (Blood. 2011;117(12): 3294-3301)
  •  
25.
  • Massy, ZA, et al. (författare)
  • Nephrology and Public Policy Committee propositions to stimulate research collaboration in adults and children in Europe
  • 2019
  • Ingår i: Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. - : Oxford University Press (OUP). - 1460-2385. ; 34:9, s. 1469-1480
  • Tidskriftsartikel (refereegranskat)abstract
    • The strengths and the limitations of research activities currently present in Europe are explored in order to outline how to proceed in the near future. Epidemiological and clinical research and public policy in Europe are generally considered to be comprehensive and successful, and the European Renal Association – European Dialysis and Transplant Association (ERA-EDTA) is playing a key role in the field of nephrology research. The Nephrology and Public Policy Committee (NPPC) aims to improve the current situation and translation into public policy by planning eight research topics to be supported in the coming 5 years by ERA-EDTA.
  •  
26.
  •  
27.
  • Nelson, A. J., et al. (författare)
  • Soft x-ray free electron laser microfocus for exploring matter under extreme conditions
  • 2009
  • Ingår i: Optics Express. - 1094-4087. ; 17:20, s. 18271-18278
  • Tidskriftsartikel (refereegranskat)abstract
    • We have focused a beam (BL3) of FLASH (Free-electron LASer in Hamburg: lambda = 13.5 nm, pulse length 15 fs, pulse energy 10-40 mu J, 5Hz) using a fine polished off-axis parabola having a focal length of 270 mm and coated with a Mo/Si multilayer with an initial reflectivity of 67% at 13.5 nm. The OAP was mounted and aligned with a picomotor controlled six-axis gimbal. Beam imprints on poly(methyl methacrylate) -PMMA were used to measure focus and the focused beam was used to create isochoric heating of various slab targets. Results show the focal spot has a diameter of <= 1 mu m. Observations were correlated with simulations of best focus to provide further relevant information.
  •  
28.
  •  
29.
  •  
30.
  •  
31.
  •  
32.
  •  
33.
  •  
34.
  •  
35.
  •  
36.
  •  
37.
  •  
38.
  •  
39.
  •  
40.
  • Schmid, C, et al. (författare)
  • Long-term results and GvHD after prophylactic and preemptive donor lymphocyte infusion after allogeneic stem cell transplantation for acute leukemia
  • 2022
  • Ingår i: Bone marrow transplantation. - : Springer Science and Business Media LLC. - 1476-5365 .- 0268-3369. ; 57:2, s. 215-223
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on 318 patients with acute leukemia, receiving donor lymphocyte infusion (DLI) in complete hematologic remission (CHR) after allogeneic stem cell transplantation (alloSCT). DLI were applied preemptively (preDLI) for minimal residual disease (MRD, n = 23) or mixed chimerism (MC, n = 169), or as prophylaxis in high-risk patients with complete chimerism and molecular remission (proDLI, n = 126). Median interval from alloSCT to DLI1 was 176 days, median follow-up was 7.0 years. Five-year cumulative relapse incidence (CRI), non-relapse mortality (NRM), leukemia-free and overall survival (LFS/OS) of the entire cohort were 29.1%, 12.7%, 58.2%, and 64.3%. Cumulative incidences of acute graft-versus-host disease (aGvHD) grade II–IV°/chronic GvHD were 11.9%/31%. Nineteen patients (6%) died from DLI-induced GvHD. Age ≥60 years (p = 0.046), advanced stage at transplantation (p = 0.003), shorter interval from transplantation (p = 0.018), and prior aGvHD ≥II° (p = 0.036) were risk factors for DLI-induced GvHD. GvHD did not influence CRI, but was associated with NRM and lower LFS/OS. Efficacy of preDLI was demonstrated by decreasing MRD/increasing blood counts in 71%, and increasing chimerism in 70%. Five-year OS after preDLI for MRD/MC was 51%/68% among responders, and 37% among non-responders. The study describes response and outcome of DLI in CHR and helps to identify candidates without increased risk of severe GvHD.
  •  
41.
  •  
42.
  • Schropp, Andreas, et al. (författare)
  • Full spatial characterization of a nanofocused x-ray free-electron laser beam by ptychographic imaging
  • 2013
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 3, s. 1633-
  • Tidskriftsartikel (refereegranskat)abstract
    • The emergence of hard X-ray free electron lasers (XFELs) enables new insights into many fields of science. These new sources provide short, highly intense, and coherent X-ray pulses. In a variety of scientific applications these pulses need to be strongly focused. In this article, we demonstrate focusing of hard X-ray FEL pulses to 125 nmusing refractive x-ray optics. For a quantitative analysis of most experiments, the wave field or at least the intensity distribution illuminating the sample is needed. We report on the full characterization of a nanofocused XFEL beam by ptychographic imaging, giving access to the complex wave field in the nanofocus. From these data, we obtain the full caustic of the beam, identify the aberrations of the optic, and determine the wave field for individual pulses. This information is for example crucial for high-resolution imaging, creating matter in extreme conditions, and nonlinear x-ray optics.
  •  
43.
  • Schropp, Andreas, et al. (författare)
  • Scanning coherent x-ray microscopy as a tool for XFEL nanobeam characterization
  • 2013
  • Ingår i: Proceedings of SPIE. - : SPIE. - 9780819496997
  • Konferensbidrag (refereegranskat)abstract
    • During the last years, scanning coherent x-ray microscopy, also called ptychography, has revolutionized nanobeam characterization at third generation x-ray sources. The method yields the complete information on the complex valued, nanofocused wave field with high spatial resolution. In an experiment carried out at the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS) we successfully applied the method to an attenuated nanofocused XFEL beam with a size of 180(h) × 150(v) nm2 (FWHM) in horizontal (h) and vertical direction (v), respectively. It was created by a set of 20 beryllium compound refractive lenses (Be-CRLs). By using a fast detector (CSPAD) to record the diffraction patterns and a fast implementation of the phase retrieval code running on a graphics processing unit (GPU), the applicability of the method as a real-time XFEL nanobeam diagnostic is highlighted.
  •  
44.
  •  
45.
  •  
46.
  • Uhlén, Fredrik, et al. (författare)
  • Damage investigation on tungsten and diamond diffractive optics at a hard x-ray free-electron laser
  • 2013
  • Ingår i: Optics Express. - : Optical Society America. - 1094-4087. ; 21:7, s. 8051-8061
  • Tidskriftsartikel (refereegranskat)abstract
    • Focusing hard x-ray free-electron laser radiation with extremely high fluence sets stringent demands on the x-ray optics. Any material placed in an intense x-ray beam is at risk of being damaged. Therefore, it is crucial to find the damage thresholds for focusing optics. In this paper we report experimental results of exposing tungsten and diamond diffractive optics to a prefocused 8.2 keV free-electron laser beam in order to find damage threshold fluence levels. Tungsten nanostructures were damaged at fluence levels above 500 mJ/cm(2). The damage was of mechanical character, caused by thermal stress variations. Diamond nanostructures were affected at a fluence of 59 000 mJ/cm(2). For fluence levels above this, a significant graphitization process was initiated. Scanning Electron Microscopy (SEM) and mu-Raman analysis were used to analyze exposed nanostructures.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-46 av 46

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy