1.
  • Ben Rayana, Mohammed C., et al. (författare)
  • IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma
  • 2008
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - 1434-6621 .- 1437-4331. ; 46:1, s. 21-26
  • Tidskriftsartikel (refereegranskat)abstract
    • Analyzers with ion-selective electrodes (ISEs) for ionized magnesium (iMg) should yield comparable and unbiased results for iMg. This IFCC guideline on sampling, measuring and reporting iMg in plasma provides a prerequisite to achieve this goal [in this document, "plasma" refers to circulating plasma and the forms in which it is sampled, namely the plasma phase of anticoagulated whole blood (or "blood"), plasma separated from blood cells, or serum]. The guideline recommends measuring and reporting ionized magnesium as a substance concentration relative to the substance concentration of magnesium in primary aqueous calibrants with magnesium, sodium, and calcium chloride of physiological ionic strength. The recommended name is "the concentration of ionized magnesium in plasma". Based on this guideline, results will be approximately 3% higher than the true substance concentration and 4% lower than the true molality in plasma. Calcium ions interfere with all current magnesium ion-selective electrodes (Mg-ISEs), and thus it is necessary to determine both ions simultaneously in each sample and correct the result for Ca2+ interference. Binding of Mg in plasma is pH-dependent. Therefore, pH should be measured simultaneously with iMg to allow adjustment of the result to pH 7.4. The concentration of iMg in plasma may be physiologically and clinically more relevant than the concentration of total magnesium. Furthermore, blood-gas analyzers or instruments for point-of-care testing are able to measure plasma iMg using whole blood (with intact blood cells) as the sample, minimizing turnaround time compared to serum and plasma, which require removal of blood cells.
  •  
2.
  • Ben Rayana, Mohammed C, et al. (författare)
  • Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood
  • 2006
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - 1434-6621 .- 1437-4331. ; 44:3, s. 346-352
  • Tidskriftsartikel (refereegranskat)abstract
    • The proposed recommendation for measuring and reporting chloride in undiluted plasma† or blood by ion-selective electrodes (ISEs) will provide results that are identical to chloride concentrations measured by coulometry for standardized normal plasma or blood samples. It is applicable to all current ISEs dedicated to chloride measurement in undiluted samples that meet the requirements. However, in samples with reduced water concentration, results by coulometry are lower than by ion-selective electrode due to volume displacement. The quantity measured by this standardized ISE procedure is called the ionized chloride concentration. It may be clinically more relevant than the chloride concentration as determined by coulometry, photometry or by ISE after dilution of the sample. © 2006 by Walter de Gruyter.
  •  
3.
  • DOrazio, Paul, et al. (författare)
  • Approved IFCC recommendation on reporting results for blood glucose (abbreviated)
  • 2005
  • Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 51:9, s. 1573-1576
  • Tidskriftsartikel (refereegranskat)abstract
    • In current clinical practice, plasma and blood glucose are used interchangeably with a consequent risk of clinical misinterpretation. In human blood, glucose, like water, is distributed between erythrocytes and plasma. The molality of glucose (amount of glucose per unit of water mass) is the same throughout the sample, but the concentration is higher in plasma because the concentration of water and, therefore, glucose is higher in plasma than in erythrocytes. Different devices for the measurement of glucose may detect and report fundamentally different quantities. Different water concentrations in calibrators, plasma, and erythrocyte fluid can explain some of the differences. Results of glucose measurements depend on sample type and on whether methods require sample dilution or use biosensors in undiluted samples. If the results are mixed up or used indiscriminately, the differences may exceed the maximum allowable error of glucose determinations for diagnosing and monitoring diabetes mellitus, and complicate the treatment. The goal of the IFCC Scientific Division Working Group on Selective Electrodes and Point of Care Testing (IFCC-SD, WG-SEPOCT) is to reach a global consensus on reporting results. The document recommends reporting the concentration of glucose in plasma (with the unit mmol/L), irrespective of sample type or measurement technique. A constant factor of 1.11 is used to convert concentration in whole blood to the equivalent concentration in the pertinent plasma. The conversion will provide harmonized results, facilitating the classification and care of patients and leading to fewer therapeutic misjudgments. © 2005 American Association for Clinical Chemistry.
  •  
4.
  •  
5.
  • Wagenaar-Bos, Ineke G. A., et al. (författare)
  • Functional C1-inhibitor diagnostics in hereditary angioedema: Assay evaluation and recommendations
  • 2008
  • Ingår i: Journal of Immunological Methods. - : Elsevier BV. - 1872-7905 .- 0022-1759. ; 338:1-2, s. 14-20
  • Tidskriftsartikel (refereegranskat)abstract
    • Hereditary angioedema (HAE) is an autosomal dominant disease characterized by recurrent episodes of potentially life-threatening angioedema. The most widespread underlying genetic deficiency is a heterozygous deficiency of the serine protease inhibitor Cl esterase inhibitor (C1-Inh). In addition to low C4 levels, the most important laboratory parameter for correct diagnosis of HAE or angioedema due to acquired C1-Inh deficiency is reduced C1-Inh function (fC1-Inh). No direct recommendations about the assays for fC1-Inh or sample handling conditions are available, although this would prove especially useful when a laboratory first starts to offer assays on fC1-Inh for HAE diagnosis. In the present study we evaluated the performance of fC1-Inh assays in the 15 different laboratories that are specialised in HAE diagnostics and assessed inter-laboratory variation with each laboratory using their own assays and standards. A double-blind survey was conducted using plasma/serum samples from healthy donors and HAE patients and the uniformity of HAE diagnosis was evaluated. It can be concluded that the diagnosis of fC1-Inh deficiency was made correctly inmost cases in this survey. We can recommend the chromogenic assay for the determination of fC1-Inh, while the complex ELISA needs further investigation. (C) 2008 Elsevier B.V. All rights reserved.
  •  