SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Norda R) "

Sökning: WFRF:(Norda R)

  • Resultat 1-23 av 23
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Mörtzell Henriksson, Monica, et al. (författare)
  • Adverse events in apheresis : an update of the WAA registry data
  • 2016
  • Ingår i: Transfusion and apheresis science. - : Elsevier. - 1473-0502 .- 1878-1683. ; 54:1, s. 2-15
  • Forskningsöversikt (refereegranskat)abstract
    • Apheresis with different procedures and devices are used for a variety of indications that may have different adverse events (AEs). The aim of this study was to clarify the extent and possible reasons of various side effects based on data from a multinational registry. The WAA-apheresis registry data focus on adverse events in a total of 50846 procedures in 7142 patients (42% women). AEs were graded as mild, moderate (need for medication), severe (interruption due to the AE) or death (due to AE). More AEs occurred during the first procedures versus subsequent (8.4 and 5.5%, respectively). AEs were mild in 2.4% (due to access 54%, device 7%, hypotension 15%, tingling 8%), moderate in 3% (tingling 58%, urticaria 15%, hypotension 10%, nausea 3%), and severe in 0.4% of procedures (syncope/hypotension 32%, urticaria 17%, chills/fever 8%, arrhythmia/asystole 4.5%, nausea/vomiting 4%). Hypotension was most common if albumin was used as the replacement fluid, and urticaria when plasma was used. Arrhythmia occurred to similar extents when using plasma or albumin as replacement. In 64% of procedures with bronchospasm, plasma was part of the replacement fluid used. Severe AEs are rare. Although most reactions are mild and moderate, several side effects may be critical for the patient. We present side effects in relation to the procedures and suggest that safety is increased by regular vital sign measurements, cardiac monitoring and by having emergency equipment nearby.
  •  
3.
  • Stegmayr, Bernd G, et al. (författare)
  • Panorama of adverse events during cytapheresis
  • 2013
  • Ingår i: Transfusion and apheresis science. - : Pergamon Press. - 1473-0502 .- 1878-1683. ; 48:2, s. 155-156
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
4.
  • Stegmayr, B. G., et al. (författare)
  • Plasma exchange as rescue therapy in multiple organ failure including acute renal failure
  • 2003
  • Ingår i: Crit Care Med. ; 31:6, s. 1730-6
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To describe the outcome of using a rescue therapy including plasma exchange given to patients with a progressive acute disseminated intravascular coagulation and multiple organ dysfunction syndrome. STUDY DESIGN: Retrospective study. SETTING: University and county hospital. PATIENTS: Included were 76 consecutive patients (41 men and 35 women) treated with plasma exchange as rescue therapy besides optimal conventional therapy during a progressive course of disseminated intravascular coagulation and multiple organ dysfunction syndrome, including acute renal failure. Of the 76 patients, 66% needed dialysis. The distribution was hemodialysis in 76%, continuous arteriovenous hemofiltration in 36%, continuous venovenous hemodialysis in 12%, and peritoneal dialysis in 24%. The median organ-failure score was 5 (range, 1-6). Seventy-two percent required mechanical ventilation; septic shock was present in 88%. The median septic shock score was 4 (range, 2-4). Nine patients had another reason than sepsis for the multiple organ dysfunction syndrome. INTERVENTION: Plasma exchange (centrifugation technique) was performed until disseminated intravascular coagulation was reversed (median, two times; range, 1-14). Besides antibiotics and fluid administration, most patients received heparin or low molecular weight heparin (77%), steroids (87%), and inotropes (88%). More than one vasoactive drug was used in 57% of the patients. MEASUREMENTS AND MAIN RESULTS: Eighty-two percent of the patients survived and could leave the hospital. The previously observed survival rates by others for this category of patients would be <20%, and thus, the outcome in this study is significantly better. CONCLUSION: Plasma exchange using plasma as replacement may, in addition to conventional intensive care, help to reverse severe progressive disseminated intravascular coagulation and multiple organ dysfunction syndrome and improve survival.
  •  
5.
  • Stegmayr, B. G., et al. (författare)
  • Plasma exchange or immunoadsorption in patients with rapidly progressive crescentic glomerulonephritis : A Swedish multi-center study
  • 1999
  • Ingår i: International Journal of Artificial Organs. - : SAGE Publications. - 0391-3988 .- 1724-6040. ; 22:2, s. 81-87
  • Tidskriftsartikel (refereegranskat)abstract
    • A therapeutic removal of antibodies may be achieved by immunoadsorption (IA) or by plasma exchange (PE). The aim of this prospective randomised study was to compare the efficacy of these different techniques with regard to treatment of patients with rapidly progressive glomerulonephritis (RPG) having at least 50% crescents. Forty-four patients with a RPG were included for treatment either by IA or PE (with albumin as substitution for removed plasma). All patients were additionally treated with immunosuppression. A median of 6 sessions of PEs were performed in 23 patients compared with 6 IAs in 21 patients. Goodpasture's syndrome (GP) was present in 6 patients (PE 3, IA 3). All of them started and ended in dialysis, two died. Among the remaining 38 patients (26 men, 12 women) 87% had antibodies to ANCA. Creatinine clearance for PE versus IA were at a median at start 17.1 and 19.8 ml/min, and at 6 months 49 and 49 ml/min, respectively. At 6 months 7 of 10 patients did not need dialysis (remaining: IA 0/5 and PE 2/5, n.s.). The extent of improvement did not differ between the groups. Three patients died during the observation period of 6 months (IA 2; PE 1, on HD). Although no difference was found between the IA or the PE group this study shows that the protocol used was associated with an improved renal function in most patients (except for Goodpasture's syndrome) whereas 70% of them could leave the dialysis program.
  •  
6.
  •  
7.
  • Beck, R., et al. (författare)
  • GPSDTN : Predictive velocity-enabled delay-tolerant networks for arctic research and sustainability
  • 2007
  • Ingår i: Second International Conference on Internet Monitoring and Protection (ICIMP 2007). - Los Alamitos, Calif : IEEE Computer Society Press. - 9780769529110
  • Konferensbidrag (refereegranskat)abstract
    • A Delay-Tolerant Network (DTN) is a necessity for communication nodes that may need to wait for long periods to form networks. The IETF Delay Tolerant Network Research Group is developing protocols to enable such networks for a broad variety of Earth and interplanetary applications. The Arctic would benefit from a predictive velocity-enabled version of DTN that would facilitate communications between sparse, ephemeral, often mobile and extremely power-limited nodes. We propose to augment DTN with power-aware, buffer-aware location- and time-based predictive routing for ad-hoc meshes to create networks that are inherently location and time (velocity) aware at the network level to support climate research, emergency services and rural education in the Arctic. On Earth, the primary source of location and universal time information for networks is the Global Positioning System (GPS). We refer to this Arctic velocity-enabled Delay-Tolerant Network protocol as "GPSDTN" accordingly. This paper describes our requirements analysis and general implementation strategy for GPSDTN to support Arctic research and sustainability efforts
  •  
8.
  • Cederbrant, Karin, et al. (författare)
  • In vitro Lymphoproliferative Assays with HgCl2 Cannot Identify Patients with Systemic Symptoms Attributed to Dental Amalgam
  • 1999
  • Ingår i: Journal of Dental Research. - : SAGE Publications. - 0022-0345 .- 1544-0591. ; 78:8, s. 1450-1458
  • Tidskriftsartikel (refereegranskat)abstract
    • Dental amalgam is suspected, by some exposed individuals, to cause various systemic psychological, sensory, and neurological symptoms. Since not all amalgam-bearers experience such reactions, an individual characteristic—for example, a susceptible immune system—might explain these conditions. In vitro lymphocyte proliferation is a valuable tool in the diagnosis of allergy. With HgCl2 as the antigen, however, the test is hampered, because Hg2+ can cause unspecific lymphocyte proliferation, optimal at 1.4 to 9.5 μg HgCl2/mL. Recently, the use of suboptimal HgCl2 concentrations (≤ 0.5 μg/mL) has been suggested to circumvent these problems. The main aim of this study was to investigate whether patients with systemic symptoms alleged to result from the presence of dental amalgam differ from healthy controls, with reference to in vitro lymphoproliferative responses to HgCl2 ≤ 0.5 μg/mL. Three different test protocols—lymphocyte transformation test (LTT) in micro- and macro-cultures, and the memory lymphocyte immunostimulation assay (MELISA®)—were used. Other immune parameters—such as a standard patch test for dental materials, the number of T- and B-lymphocytes, monocytes, granulocytes, and NK cells in peripheral blood, allergic symptoms, and predisposition-were also investigated. Twenty-three amalgam patients, 30 healthy blood donors with amalgam, ten healthy subjects without amalgam, and nine patients with oral lichen planus (OLP) adjacent to dental amalgam and a positive patch test to Hg0 were tested. None of the investigated immune parameters revealed any significant differences between amalgam patients and controls. The sensitivity of in vitro lymphocyte proliferation ranged from 33 to 67%, with the OLP patients as a positive control group, and the specificity from 0 to 70% for healthy controls with a negative patch test to Hg°. Thus, despite the use of HgCl2 ≤ 0.5 μg/mL, a high frequency of positive results was obtained among healthy subjects with or without dental amalgam. Consequently, in vitro lymphocyte proliferation with HgCl2 cannot be used as an objective marker for mercury allergy in dental amalgam-bearers.
  •  
9.
  •  
10.
  •  
11.
  •  
12.
  •  
13.
  • Norda, R., et al. (författare)
  • Adverse events and problems in therapeutic hemapheresis. A report from the Swedish registry
  • 2001
  • Ingår i: Transfusion and apheresis science. - 1473-0502 .- 1878-1683. ; 25:1, s. 33-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Since 1996 adverse events (AE) in therapeutic apheresis (TA) have been more extensively registered in Sweden. This report analyzes the extent and relation of AEs to procedures and diagnoses. Materials and methods: Reporting of TA performed in Sweden was centralized. A separate system for the registration of AE in TA was established and the data received were entered into a central database for registration and analyses. Fifteen of all 35 apheresis units reported both TA and AE during 1996-1999. These centers performed 75% of all TA procedures. Adverse events included medical symptoms, vascular access problems, technical and other problems. Results: More than 14,000 procedures were registered during the observation period. No fatalities occurred. AEs occurred in 3.7% (1996), 4.6% (1997), 4.2% (1998) and 4.4% (1999) of procedures. Interventions during the adverse event were performed in about 65% of the events. Apheresis procedures were interrupted due to an adverse event in about 1%. Adverse events occurred in 5.6% of plasma exchanges, 1.9% of plasma modulations and 6.8% of cytapheresis procedures. Paresthesia was registered in 22% and hypotensive events in 20.5%. Other more frequent symptoms were urticaria (14.4%), shivering (7.4%) and nausea (7.4%). AEs were most frequent in patients with Goodpasture's syndrome (12.5%), TTP/HUS (10.5%) and GuillainBarré syndrome (11.0%). Conclusion: AEs are few, often mild and less common in plasma modulation than plasma exchange. AEs are more frequent during TA of patients with certain diagnoses such as TTP/HUS. Copyright © 2001 Elsevier Science Ltd.
  •  
14.
  •  
15.
  • Offergeld, R., et al. (författare)
  • Sexual risk behaviour and donor deferral in Europe
  • 2014
  • Ingår i: Vox Sanguinis. - : Wiley. - 0042-9007 .- 1423-0410. ; 107:4, s. 420-427
  • Tidskriftsartikel (refereegranskat)abstract
    • One of the most controversial policies in blood transfusion worldwide is the permanent deferral from donating blood of men with sexual contacts to other men (MSM). This policy was implemented for safety reasons as sex between men is known to be a high risk factor for acquiring severe infectious diseases transmissible by blood transfusion. Sexual contacts among heterosexual persons may hold similar risks but a clear-cut discrimination between different individual risks is impossible. Nevertheless, the current blood donor deferral periods defined by European Union (EU) legislation depend on a distinction of different grades of risk with respect to sexual behaviour. Under the aegis of the Steering Committee on Blood Transfusion (CD-P-TS) of the Council of Europe (CoE), an international working group evaluated epidemiological and behavioural data, modelling studies on residual risk and spread of infections, and studies on adherence to donor selection criteria. The aim was to distinguish sexual behaviour of different risk categories. It was concluded, that existing data confirm that MSM and commercial sex workers (CSW) are groups at high risk. Any further grading lacks a scientific data base. Modelling studies indicate that adherence to deferral policies is of major relevance suggesting that good donor adherence may outweigh the small negative effects on blood safety postulated for changing from permanent to temporary deferral periods for high risk sexual behaviours. The fact that a considerable percentage of donors are MSM - despite the permanent deferral policy - demonstrates the need to increase donor understanding and adherence.
  •  
16.
  •  
17.
  •  
18.
  • Stegmayr, Bernd, et al. (författare)
  • World apheresis registry
  • 2005
  • Ingår i: Journal of clinical apheresis. - New York : Allen R. Liss. - 0733-2459 .- 1098-1101. ; 20:2, s. 126-127
  • Tidskriftsartikel (refereegranskat)
  •  
19.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-23 av 23

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy