SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ohrnell Lars Olof) "

Sökning: WFRF:(Ohrnell Lars Olof)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Slotte, Christer, 1954, et al. (författare)
  • Four-Millimeter Implants Supporting Fixed Partial Dental Prostheses in the Severely Resorbed Posterior Mandible: Two-Year Results.
  • 2011
  • Ingår i: Clinical implant dentistry and related research. - : Wiley. - 1708-8208 .- 1523-0899.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Reduced alveolar bone volume complicates implant dentistry. Purpose: In this prospective multicenter study, a new, 4-mm long Straumann SLActive implant (Ø 4.1mm) supporting a fixed dental prosthesis (FDP) in the severely resorbed posterior mandible was evaluated for two years. Material and Methods: Thirty-two patients (11 men, 21 women; mean age 64.1 years) participated. Ten to 12 weeks after single-stage surgery, a screw-retained FDP was attached to three or four 4-mm implants. Results and Discussion: One hundred implants were inserted. Three failed at surgery and four were lost before loading. Twenty-eight patients received FDPs (93 implants). Two patients were discontinued because of secondary exclusion criteria; therefore, 26 patients were followed up from baseline (BL). After 1 year, one patient insisted on removal of all implants and one patient died because of nonstudy-related complications. Twenty-four patients (87 implants) were eligible for examination 2 years post-loading. All implants were found to be stable [survival rate 95.7% (confidence interval, CI 88.8-98.3) after 1 year and 92.3% (CI 84.5-96.2) after 2 years]. The mean change from BL to 12 months was - 0.43mm (CI 0.31-0.59; p<.001) and from 12 to 24 months - 0.11mm (CI -0.01-0.23; p=.056). The survival rate is only slightly lower than in similar studies on 6 to 8.5mm implants. This may be related to high initial stability and effective use of the residual bone volume with high primary bone-to-implant contact in dense bone structures. The surgical handling of the tested implant was found to be similar to that of implants of common length. However, the preparation procedure must be done with great care to avoid overdrilling. Careful planning and design of the prosthetic construction is mandatory to prevent unfavorable occlusion and avoid harmful shear forces. Conclusion: This study showed that 4mm implants can support an FDP in severely resorbed posterior mandibles for at least 2 years and with healthy peri-implant conditions.
  •  
2.
  • Slotte, Christer, 1954, et al. (författare)
  • Four-Millimeter-Long Posterior-Mandible Implants: 5-Year Outcomes of a Prospective Multicenter Study.
  • 2015
  • Ingår i: Clinical implant dentistry and related research. - : Wiley. - 1708-8208 .- 1523-0899. ; 17:2
  • Tidskriftsartikel (refereegranskat)abstract
    • There is lack of evidence on long-term success of short dental implants in reduced alveolar bone. Purpose In this prospective 5-year study, survival and marginal bone loss of 4-mm implants, which supported fixed dental prostheses (FDPs) in severely resorbed posterior mandibles, were evaluated. Material and Methods In 28 patients, evaluation of 86 osseointegrated 4-mm-long implants, which supported a 3- or a 4-unit FDP by crown splinting without the use of pontics or cantilevers, was performed over a 5-year period. Results Three subjects dropped out for non-study reasons: one subject had her three implants removed after 1 year and two subjects died (six implants). Five implants in three subjects were lost between 3 and 5 years. Twenty-four subjects and 71 implants were active at the 5-year follow-up (92.2% survival). After 1 year, significant (p<.001) mean (standard error of the mean [SEM]) 0.44-mm (0.05) marginal bone loss occurred. At 2, 3, and 5 years, mean (SEM) bone loss of 0.57mm (0.06), 0.55mm (0.07), and 0.53mm (0.08) occurred, respectively (no significant change after 1 year). At 5 years, average plaque levels were 13.3%; 69% of the implants were plaque free. On average, mucosal bleeding occurred at 8.1% of the implants. During 5 years, two subjects experienced uncomplicated bridge loosening. No other complications occurred during the study. Conclusion Four-millimeter implants can support FDPs in severely resorbed posterior mandibles for 5 years with healthy peri-implant conditions.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy