  • Alcala, Yvonne, et al. (författare)
  • Qualifying CT for wrist arthroplasty : Extending techniques for total hip arthroplasty to total wrist arthroplasty
  • 2005
  • Ingår i: Medical Imaging 2005. - : SPIE - The International Sooceity for Optical Engineeering. - 0819457213 ; , s. 1155-1164
  • Konferensbidrag (refereegranskat)abstract
    • The purpose of this study was to extend previous work to detect migration of total wrist arthroplasty non-invasively, and with greater accuracy. Two human cadaverous arms, each with a cemented total wrist implant, were used in this study. In one of the arms, I mm tantalum balls were implanted, six in the carpal bones and five in the radius. Five CT scans of each arm were acquired, changing the position of the arm each time to mimic different positions patients might take on repeated examinations. Registration of CT volume data sets was performed using an extensively validated, 3D semi-automatic volume fusion tool in which co-homologous point pairs (landmarks) are chosen on each volume to be registered. Three sets of ten cases each were obtained by placing landmarks on 1) bone only (using only arm one), 2) tantalum implants only, and 3) bone and tantalum implants (both using only arm two). The accuracy of the match was assessed visually in 2D and 3D, and numerically by calculating the distance difference between the actual position of the transformed landmarks and their ideal position (i.e., the reference landmark positions). All cases were matched visually within one width of cortical bone and numerically within one half CT voxel (0.32 mm, p = 0.05). This method matched only the bone/arm and not the prosthetic component per se, thus making it possible to detect prosthetic movement and wear. This method was clinically used for one patient with pain. Loosening of the carpal prosthetic component was accurately detected and this was confirmed at surgery.
  •  
2.
  • Goldvasser, Dov, et al. (författare)
  • A New Technique for Measuring Wear in Total Hip Arthroplasty Using Computed Tomography
  • 2012
  • Ingår i: The Journal of Arthroplasty. - : Elsevier. - 0883-5403 .- 1532-8406. ; 27:9, s. 1636-1640
  • Tidskriftsartikel (refereegranskat)abstract
    • Accurately estimating polyethylene wear in 3 dimensions, without the need for additional procedures or equipment, is of significant interest. We investigated the use of a high-resolution clinical computed tomographic (CT) scanner to estimate femoral head displacement relative to the cup as an indirect method of estimating polyethylene wear. A hip phantom was used to simulate the 3-dimensional displacement of a femoral head. The phantom was imaged in a high-resolution CT scanner. The mean difference between the true phantom displacement as positioned by micrometers and the calculated displacement based on the CT images was as follows: for the x-axis, 0 mm (SD, 0.213; SE, 0.058); y-axis, 0.039 mm (SD, 0.035; SE, 0.026); and z-axis, 0.039 mm (SD, 0.051; SE, 0.020).
  •  
3.
  • Goldvasser, Dov, et al. (författare)
  • In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty
  • 2014
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 85:3, s. 271-275
  • Tidskriftsartikel (refereegranskat)abstract
    • Background - Determination of the amount of wear in a polyethylene liner following total hip arthroplasty (THA) is important for both the clinical care of individual patients and the development of new types of liners. Patients and methods - We measured in vivo wear of the polyethylene liner using computed tomography (CT) (obtained in the course of regular clinical care) and compared it to coordinate-measuring machine (CMM) readings. Also, changes in liner thickness of the same retrieved polyethylene liner were measured using a micrometer, and were compared to CT and CMM measurements. The distance between the centers of the acetabular cup and femoral head component was measured in 3D CT, using a semi-automatic analysis method. CMM readings were performed on each acetabular liner and data were analyzed using 3D computer-aided design software. Micrometer readings compared the thickest and thinnest regions of the liner. We analyzed 10 THA CTs and retrievals that met minimal requirements for CT slice thickness and explanted cup condition. Results - For the 10 cups, the mean difference between the CT readings and the CMM readings was -0.09 (-0.38 to 0.20) mm. This difference was not statistically significant (p = 0.6). Between CT and micrometer, the mean difference was 0.11 (-0.33 to 0.55) mm. This difference was not statistically significant (p = 0.6). Interpretation - Our results show that CT imaging is ready to be used as a tool in clinical wear measurement of polyethylene liners used in THA.
  •  
4.
  • Jedenmalm, Anneli, et al. (författare)
  • A new approach for assessment of wear in metal-backed acetabular cups using computed tomography : a phantom study with retrievals
  • 2008
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 79:2, s. 218-224
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose Polyethylene wear is an important cause of aseptic loosening in hip arthroplasty. Detection of significant wear usually happens late on, since available diagnostic techniques are either not sensitive enough or too complicated and expensive for routine use. This study evaluates a new approach for measurement of linear wear of metal-backed acetabular cups using CT as the intended clinically feasible method. Material and methods 8 retrieved uncemented metal-backed acetabular cups were scanned twice ex vivo using CT. The linear penetration depth of the femoral head into the cup was measured in the CT volumes using dedicated software. Landmark points were placed on the CT images of cup and head, and also on a reference plane in order to calculate the wear vector magnitude and angle to one of the axes. A coordinate-measuring machine was used to test the accuracy of the proposed CT method. For this purpose, the head diameters were also measured by both methods. Results Accuracy of the CT method for linear wear measurements was 0.6 nm and wear vector angle was 27 degrees. No systematic difference was found between CT scans. Interpretation This study on explanted acetabular cups shows that CT is capable of reliable measurement of linear wear in acetabular cups at a clinically relevant level of accuracy. It was also possible to use the method for assessment of direction of wear.
  •  
5.
  • Lundblad, Henrik, et al. (författare)
  • Can Na18F PET/CT Be Used to Study Bone Remodeling in the Tibia When Patients Are Being Treated with a Taylor Spatial Frame?
  • 2014
  • Ingår i: Scientific World Journal. - : Hindawi Publishing Corporation. - 1537-744X .- 2356-6140. ; 2014, s. 1-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Monitoring and quantifying bone remodeling are of interest, for example, in correction osteotomies, delayed fracture healing pseudarthrosis, bone lengthening, and other instances. Seven patients who had operations to attach an Ilizarov-derived Taylor Spatial Frame to the tibia gave informed consent. Each patient was examined by (NaF)-F-18 PET/CT twice, at approximately six weeks and three months after the operation. A validated software tool was used for the following processing steps. The first and second CT volumes were aligned in 3D and the respective PET volumes were aligned accordingly. In the first PET volume spherical volumes of interest (VOIs) were delineated for the crural fracture and normal bone and transferred to the second PET volume for SUVmax evaluation. This method potentially provides clinical insight into questions such as, when has the bone remodeling progressed well enough to safely remove the TSF? and when is intervention required, in a timelier manner than current methods? For example, in two patients who completed treatment, the SUVmax between the first and second PET/CT examination decreased by 42% and 13%, respectively. Further studies in a larger patient population are needed to verify these preliminary results by correlating regional (NaF)-F-18 PET measurements to clinical and radiological findings.
  •  
6.
  • Noz, Marilyn E., et al. (författare)
  • Clinical applications from head to toe using a semiautomatic 3D inter/intramodality fusion technique
  • 2003
  • Ingår i: BIOMEDICAL IMAGE REGISTRATION. - 3540203435 ; , s. 387-397
  • Konferensbidrag (refereegranskat)abstract
    • Automated image registration techniques, particularly between modalities which clearly display anatomy and especially within the head, have become commonplace. Meanwhile advances in molecular imaging and the need to perform registration in other areas of body has driven the development of non-rigid and semiautomatic 3D volume fusion methods. This paper will focus on this latter class of 3D volume registration methods for a variety of clinical applications.
  •  
7.
  • Olivecrona, Grim, et al. (författare)
  • Assessment of the sacroiliac joint with computed tomography motion analysis : a diagnostic study of 12 patients
  • 2024
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden. - 1745-3674 .- 1745-3682. ; 95, s. 20-24
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - Pain in the sacroiliac joint may be caused by abnormal joint motion. Diagnosis is mainly based on clinical tests. The aims of this study were to examine whether low-dose computed tomography with provocation of the hip could detect sacroiliac joint motion , to study whether provocation of the hip results in greater sacroiliac joint motion in the ipsilateral than in the contralateral sacroiliac joint.Patients and methods - 12 patients with sacroiliac joint pain were examined with low-dose computed tomography scans of the sacroiliac joint, one with the hips in the neutral position, and one each in provocation with the left or the right hip in a figure-of-4 position. Accuracy was tested by comparing internal rotation of the sacrum with internal rotation in the sacroiliac joint. Motion in the sacroiliac joint was assessed by comparing the position of each of the ilia with the reference, the sacrum. Data is shown as mean with 95% confidence interval (CI).Results - We observed greater motion in the sacroiliac joint than internally in the sacrum, i.e., 0.57(degrees) (CI 0.43-0.71) vs. 0.20(degrees) (CI 0.11-0.28). The motion of the geometric center of the moving object for the sacroiliac joint was larger on the provoked side; mean difference 0.17 mm (CI 0.01-0.33), P = 0.04. Corresponding figures for rotation were mean difference 0.19(degrees) (CI 0.10-0.28), P < 0.001. Compared with the sacrum, the largest motion was seen at the anterior superior iliac spine; mean difference 0.38 mm (CI 0.10-0.66), P = 0.001.Conclusion - Provocation in the figure-of-4 position of the hip results in sacroiliac joint motion measurable with computed tomography motion analysis. Provocation of the hip induces larger motion on the ipsilateral than on the contralateral sacroiliac joint.
  •  
8.
  • Olivecrona, Gunilla, et al. (författare)
  • Mutation of conserved cysteines in the Ly6 domain of GPIHBP1 in familial chylomicronemia
  • 2010
  • Ingår i: Journal of Lipid Research. - New York : Rockefeller U.P.. - 0022-2275 .- 1539-7262. ; 51:6, s. 1535-1545
  • Tidskriftsartikel (refereegranskat)abstract
    • We investigated a family from northern Sweden in which three of four siblings have congenital chylomicronemia. Lipoprotein lipase (LPL) activity and mass in pre- and post-heparin plasma were low, and LPL release into plasma after heparin injection was delayed. LPL activity and mass in adipose tissue biopsies appeared normal. [35S]Methionine incorporation studies on adipose tissue showed that newly synthesized LPL was normal in size and normally glycosylated. Breast milk from the affected female subjects contained normal to elevated LPL mass and activity levels. The milk had a lower than normal milk lipid content, and the fatty acid composition was compatible with the milk lipids being derived from de novo lipogenesis, rather than from the plasma lipoproteins. Given the delayed release of LPL into the plasma after heparin, we suspected that the chylomicronemia might be caused by mutations in GPIHBP1. Indeed, all three affected siblings were compound heterozygotes for missense mutations involving highly conserved cysteines in the Ly6 domain of GPIHBP1 (C65S and C68G). The mutant GPIHBP1 proteins reached the surface of transfected CHO cells but were defective in their ability to bind LPL (as judged by both cell-based and cell-free LPL binding assays). Thus, the conserved cysteines in the Ly6 domain are crucial for GPIHBP1 function.
  •  
9.
  • Olivecrona, Henrik, et al. (författare)
  • A new computed tomography-based radiographic method to detect early loosening of total wrist implants
  • 2007
  • Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 48:9, s. 997-1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Diagnosis of loosening of total wrist implants is usually late using routine radiographs. Switching modality to computed tomography (CT) should aid in early diagnosis. Purpose: To propose and evaluate the accuracy of a new CT method for assessing loosening of the carpal component in total wrist arthroplasty. Material and Methods: A protocol encompassing volume registration of paired CT scans of patients with unexplained pain in a prosthetically replaced wrist (used in clinical routine) is presented. Scans are acquired as a dynamic examination under torsional load. Using volume registration, the carpal component of the prosthesis is brought into spatial alignment. After registration, prosthetic loosening is diagnosed by a shift in position of the bones relative to the prosthesis. This study is a preclinical validation of this method using a human cadaverous arm with a cemented total wrist implant and tantalum markers. Seven CT scans of the arm were acquired. The scans were combined into 21 pairs of CT volumes. The carpal component was registered in each scan pair, and the residual mismatch of the surrounding tantalum markers and bone was analyzed both visually and numerically. Results: The detection limit for prosthetic movement was less than 1 mm. Conclusion: The results of this study demonstrate that CT volume registration holds promise to improve detection of movement of the carpal component at an earlier stage than is obtainable with plain radiography.
  •  
10.
  • Olivecrona, Henrik, et al. (författare)
  • A new CT method for measuring cup orientation after total hip arthroplasty : A study of 10 patients
  • 2004
  • Ingår i: Acta Orthopaedica Scandinavica. - : Medical Journals Sweden AB. - 0001-6470. ; 75:3, s. 252-260
  • Tidskriftsartikel (refereegranskat)abstract
    • Background It is difficult to assess the orientation of the acetabular component on routine radiographs. We present a method for determining the spatial orientation of the acetabular component after total hip arthroplasty (THA) using computed tomography. Patients and methods Two CT-scans, 10 min apart, were obtained from each of 10 patients after THA. Using locally developed software, two independent examiners measured the orientation of the acetabular component in relation to the pelvis. The measurements were repeated after one week. To be independent of the patient position during scanning, the method involved two steps. Firstly, a 3D volumetric image of the pelvis was brought into a standard pelvic orientation, then the orientation of the acetabular component was measured. The orientation of the acetabular component was expressed as operative anteversion and inclination relative to an internal pelvic reference coordinate system. To evaluate precision, we compared measurements across pairs of CT volumes between observers and trials. Results Mean absolute interobserver angle error was 2.3degrees for anteversion (range 0-6.6degrees), and 1.1degrees for inclination (range 0-4.6degrees). For interobserver measurements, the precision, defined as one standard deviation, was 2.9degrees for anteversion, and 1.5degrees for inclination. A Student's West showed that the overall differences between the examiners, trials, and cases were not significant. Data were normally distributed and were not dependent on examiner or trial. Interpretation We conclude that the implant angles of the acetabular component in relation to the pelvis could be detected repeatedly using CT, independently of patient positioning.
  •  
11.
  • Olivecrona, Henrik, et al. (författare)
  • A new technique for diagnosis of acetabular cup loosening using computed tomography - Preliminary experience in 10 patients
  • 2008
  • Ingår i: Acta Orthopaedica. - New York, NY, USA : Informa Healthcare. - 1745-3674 .- 1745-3682. ; 79:3, s. 346-353
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Considerable migration of the acetabular cup is required for diagnosis of loosening by conventional radiography. We have developed a new clinically applicable method for assessment of cup loosening using computed tomography (CT). Patients and methods 10 patients scheduled for revision hip replacement due to suspected wear or loosening were scanned twice with CT under torsion loading of the prosthesis. Two independent examiners assessed each patient with respect to motion of the acetabular cup relative to the pelvis using CT volume registration. The CT measurements were compared to findings at revision surgery. Results The method was applicable in 8 of the 10 patients. 1 patient had a severe tremor. In 1 patient, surgery revealed that the hip was ankylotic due to massive ectopic bone formation. This left 8 patients that could be evaluated. 4 cups were loose at surgery, and 3 of these cups could be seen to be mobile by CT. 4 cups that were stable on revision were accurately diagnosed as not being mobile by CT. Movements of less than 1 millimeter between bone and prosthesis could not be distinguished from errors in CT acquisition and volume registration. There was good agreement between the two observers. Interpretation Movement of loose acetabular cups during torsion loading could be detected using CT volume registration. It was sensitive to cup movement in 3 out of 4 cases of loose cups. The method was specific and yielded no false positive results.
  •  
12.
  • Olivecrona, Henrik, et al. (författare)
  • Spatial component position in total hip arthroplasty - Accuracy and repeatability with a new CT method
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:1, s. 84-91
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically.
  •  
13.
  • Olivecrona, Henrik, et al. (författare)
  • Stability of acetabular axis after total hip arthroplasty, repeatability using CT and a semiautomated program for volume fusion
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:6, s. 653-661
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To validate a CT method for detecting changes in acetabular cup orientation after THA. Material and Methods: 26 CT examinations were obtained from a pelvic model with an uncemented acetabular cup. The model position was altered between acquisitions, but the cup axis angle vis-a-vis the pelvis was maintained. Data sets were combined into 37 pairs, each containing a unique positioning error. The pelvi in different examinations were fused, creating transformed volumes. Landmarks corresponding to the cup before and after fusion were placed interactively by two independent examiners. The orientation of the acetabular axis was calculated for each volume and compared across volumes. Results: Before fusion the mean angle error between the acetabular axes was 4.17degrees (SD +/- 1.95degrees). After fusion the mean angle error was 0.36degrees (SD +/- 0.17). The 95% repeatability limits were below 0.7degrees. There was no significant interobserver difference. Analysis of the cup landmarking pattern by condition numbers and individual landmark errors showed stability. Conclusion: Non-invasive fusion of CT volumes and a stable landmarking pattern for the acetabular cup outperforms routine plain radiography in detecting changes in the orientation of the acetabular axis over time. The method delivers both visual and numerical output and could be used in clinical practice.
  •  
14.
  • Olivecrona, Lotta, et al. (författare)
  • Acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
  • 2002
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 43:5, s. 517-527
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To develop a non-invasive method for detection of acetabular cup migration after total hip arthroplasty (THA) with a higher degree of accuracy than routine plain radiography. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients that had undergone THA. Using an in-house developed semiautomated program for volume merging, the pelves in the two examinations were fused and the acetabular cup was visually and numerically evaluated to test the method's accuracy in detecting migration. Results: In the visual evaluation of the best match a 1-mm translation of the cup was detectable. The numerical evaluation, comparing landmarks placed in the images of the acetabular cup and the head of the femur component in the two examinations, showed the mean difference in orientation of acetabular axes to be 2.5degrees, the mean distance between centre of cup face to be 2.5 mm and the mean distance between centre of the head of the prosthetic femoral component to be 1 mm. Conclusion: This method has a significantly higher accuracy than routine plain radiography in detecting acetabular cup migration and could be used in clinical practice. It gives both a visual and a numerical correlate to migration.
  •  
15.
  • Olivecrona, Lotta, et al. (författare)
  • Assessing wear of the acetabular cup using computed tomography : an ex vivo study
  • 2005
  • Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 46:8, s. 852-857
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To validate a clinically useful method for measuring acetabular cup wear using computed tomography (CT). Material and Methods: Eight uncemented acetabular cups were scanned twice ex vivo using CT. The linear penetration depth of the femoral component head into the cup and the thickness of the remaining polyethylene liner were measured in the CT volumes using dedicated software. Two independent examiners twice assessed each volume. The CT measurements were compared to direct measurements using a coordinate measuring device and micrometer measurements. Results: Accuracy of wear measurements expressed as penetration depth was +/- 0.6 and +/- 1.0 mm for the two examiners, respectively, with no significant differences between examiners, trials, and CT scans. Accuracy of measurements of remaining polyethylene was +/- 1.3 and +/- 1.0 mm, respectively, for the two examiners. Systematic differences between examiners were found, but no significant differences between trials and CT scans. These differences were due to different interpretations of metal artifacts in the volumes. Conclusion: The proposed CT method for evaluating wear as head penetration depth allows for reliable wear detection at a clinically relevant level. Measurements of remaining polyethylene on CT volumes are not as reliable as wear measurements owing to metal artifacts.
  •  
16.
  • Olivecrona, Lotta, et al. (författare)
  • Model studies on acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:4, s. 419-429
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Validation of a non-invasive CT method for detection of acetabular cup migration after total hip arthroplasty in a phantom study. Material and Methods: 26 CT examinations were obtained of a pelvic model while altering the position of the acetabular cup. Using a previously described program for volume merging, the pelvi in different examinations were fused and the 3D alterations of the position of the acetabular cup were evaluated visually and numerically and correlated to direct measurements on the model. Results: Visually, two independent examiners differentiated between 0, 1 and 2 to 3 mm migration with 100% specificity and sensitivity. Numerically, the mean error over all cases between model and CT measurements was 0.04 mm (SD +/- 0.33). The mean absolute error between model and CT data was 0.26 mm (SD +/- 0.19). Intra- and interobserver 95% accuracy and repeatability limits were below 0.5/0.7 mm, respectively. No significant interobserver difference occurred. The data were normally distributed and not dependent on observer. Conclusion: The accuracy of this non-invasive method out-performs routine plain radiography. The method gives both visual and numerical correlates to migration and can be used in clinical practice.
  •  
17.
  • Olivecrona, Lotta, et al. (författare)
  • Standard orientation of the pelvis : Validation on a model and ten patients
  • 2005
  • Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 46:1, s. 74-82
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To validate an image post-processing method for re-orienting the pelvis in CT volumes to a standardized orientation in a model and in 10 patients. Material and Methods: Twenty-four CT volumes of a pelvic model and 10 pairs of postoperative total hip arthroplasty (THA) patient CT scans were rotated to a defined pelvic standard orientation and the rotation was recorded. For precision, a test-retest procedure was used. For accuracy, three exactly represented coordinate points were used. For clinical application, the standard orientation was used for calculating the direction of acetabular cup migration from a previous model study. Results: Precision of pelvic standard orientation, calculated as maximal directional error, was better than 1degrees in the model study and better than 1.5degrees in the patient study. Accuracy, expressed as angle between ideal and measured coordinate axes, was 0.1degrees for x, y, z axes. No measurable systematic errors were found. When applied to acetabular cup migration in the model, standardization of pelvic orientation had no significant effect on the measurements. Conclusion: Reorienting the pelvis during image post-processing was shown to be accurate. It enables measurements relative to the pelvis and minimizes the dependency of patient positioning.
  •  
18.
  • Bjursten, Henrik, et al. (författare)
  • The safety of introducing a new generation TAVR device : One departments experience from introducing a second generation repositionable TAVR
  • 2017
  • Ingår i: BMC Cardiovascular Disorders. - : Springer Science and Business Media LLC. - 1471-2261. ; 17:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In the evolving field of transcatheter aortic valve replacements a new generation of valves have been introduced to clinical practice. With the complexity of the TAVR procedure and the unique aspects of each TAVR device, there is a perceived risk that changing or adding a new valve in a department could lead to a worse outcome for patients, especially during the learning phase. The objective was to study the safety aspect of introducing a second generation repositionable transcatheter valve (Boston Scientific Lotus valve besides Edwards Sapien valve) in a department. Methods: In a retrospective study, 53 patients receiving the Lotus system, and 47 patients receiving the Sapien system over a period of three years were compared for short-term outcome according to VARC-2 definitions and 1-year survival. Results: Outcome in terms VARC-2 criteria for early safety and clinical efficacy, stroke rate, and survival at 30 days and at 1 year were similar. The Lotus valve had less paravalvular leakage, where 90% had none or trace aortic insufficiency as compared to only 48% for the Sapien system. Conclusions: Introduction of a new generation valve can be done with early device success and safety, and without jeopardizing the outcome for patients up to one year. We found no adverse effects by changing valve type and observed improved outcome in terms of lower PVL-rates. Both existing and new centers starting a TAVR program can benefit from the use of a new generation device.
  •  
19.
  • Brodén, Cyrus, et al. (författare)
  • Accuracy and precision of a CT method for assessing migration in shoulder arthroplasty : an experimental study
  • 2019
  • Ingår i: Acta Radiologica. - : Sage Publications. - 0284-1851 .- 1600-0455.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Radiostereometric analysis (RSA) is the gold standard to measure early implant migration which is a predictive factor for implant survival. Purpose: To validate an alternative computed tomography (CT) technique to measure implant migration in shoulder arthroplasty. Material and Methods: A cadaver proximal humerus and a scapula, which had tantalum beads incorporated within them, were prepared to accept a short-stemmed humeral component and a two-pegged glenoid component of a commercial total shoulder arthroplasty (TSA) system. A five degree of freedom micrometer and goniometer equipped rig was used to translate and rotate the implant components relative to the respective bone to predetermined positions. Double CT examinations were performed for each position and CT motion analysis software (CTMA) was used to assess these movements. The accuracy and precision of the software was estimated using the rig’s micrometers and goniometers as the gold standard. The technique’s effective dose was also assessed. Results: The accuracy was in the range of 0.07–0.23 mm in translation and 0.22–0.71° in rotation. The precision was in the range of 0.08–0.15 mm in translation and 0.23–0.54° in rotation. The mean effective dose for the CT scans was calculated to be 0.27 mSv. Conclusion: In this experimental setting, accuracy, precision, and effective dose of the CTMA technique were found to be comparable to that of RSA. Therefore, we believe clinical studies are warranted to determine if CTMA is a suitable alternative to traditional RSA for migration measurements in TSA.
  •  
20.
  • Brodén, Cyrus, et al. (författare)
  • Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups : An Experimental Study
  • 2016
  • Ingår i: BioMed Research International. - : Hindawi Publishing Corporation. - 2314-6133 .- 2314-6141.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty.Materials and Methods. With tantalum beads, we marked one cemented and one uncemented cup and mounted these on a similarly marked pelvic model. A comparison was made between 3D CT and standard RSA for measuring migration. Twelve repeated stereoradiographs and CT scans with double examinations in each position and gradual migration of the implants were made. Precision and accuracy of the 3D CT were calculated.Results. The accuracy of the 3D CT ranged between 0.07 and 0.32 mm for translations and 0.21 and 0.82° for rotation. The precision ranged between 0.01 and 0.09 mm for translations and 0.06 and 0.29° for rotations, respectively. For standard RSA, the precision ranged between 0.04 and 0.09 mm for translations and 0.08 and 0.32° for rotations, respectively. There was no significant difference in precision between 3D CT and standard RSA. The effective radiation dose of the 3D CT method, comparable to RSA, was estimated to be 0.33 mSv.Interpretation. Low dose 3D CT is a comparable method to standard RSA in an experimental setting.
  •  
21.
  • Broden, Cyrus, et al. (författare)
  • CT-based micromotion analysis method can assess early implant migration and development of radiolucent lines in cemented glenoid components : a clinical feasibility study
  • 2022
  • Ingår i: Acta Orthopaedica. - : Medical Journal Sweden AB. - 1745-3674 .- 1745-3682. ; 93, s. 277-283
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - CT micromotion analysis (CTMA) has been considered as an alternative to radiostereometry (RSA) for assessing early implant migration of orthopedic implants. We investigated the feasibility of CTMA to assess early migration and the progression of radiolucent lines in shoulder arthroplasties over 24 months using sequential low-dose CT scans. Patients and methods - 7 patients were included and underwent 9 primary total shoulder arthroplasties. We made CT scans preoperatively, within 1 week postoperatively, and after 3, 6, 12, and 24 months. At each follow-up, postoperative glenoid migration and any development of radiolucent lines were assessed. Clinical outcomes were recorded at all time points except within 1 week postoperatively. Results - For the glenoid component, the median translation and median rotation were 0.00-0.10 mm and -1.53 degrees to 1.05 degrees at 24 months. Radiolucent lines could be observed around all glenoid components. The radiolucent lines developed from the periphery to the center of the implant for 6 glenoid components during follow-up. The Constant Score improved from a mean of 30 (21-51) preoperatively to 69 (41-88) at 24 months. Interpretation - CTMA can be used to identify early migration and the development of radiolucent lines over time in glenoid components. Clinical trials with a larger sample size and longer follow-up are needed to establish the relationship between migration, radiolucent lines, loosening, and clinical outcome.
  •  
22.
  • Brodén, Cyrus, et al. (författare)
  • Low-dose CT-based implant motion analysis is a precise tool for early migration measurements of hip cups : a clinical study of 24 patients
  • 2020
  • Ingår i: Acta Orthopaedica. - : Informa UK Limited. - 1745-3674 .- 1745-3682. ; 91:3, s. 260-265
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - Early implant migration is known to be a predictive factor of clinical loosening in total hip arthroplasty (THA). Radiostereometric analysis (RSA) is the gold standard used to measure early migration in patients. However, RSA requires costly, specialized imaging equipment and the image process is complex. We determined the precision of an alternative, commercially available, CT method in 3 ongoing clinical THA studies, comprising 3 different cups.Materials and methods - 24 CT double examinations of 24 hip cups were selected consecutively from 3 ongoing prospective studies: 2 primary THA (1 cemented and 1 uncemented) and 1 THA (cemented) revision study. Precision of the CT-based implant motion analysis (CTMA) system was calculated separately for each study, using both the surface anatomy of the pelvis and metal beads placed in the pelvis.Results - For the CTMA analysis using the surface anatomy of the pelvis, the precision ranged between 0.07 and 0.31 mm in translation and 0.20° and 0.39° for rotation, respectively. For the CTMA analysis using beads the precision ranged between 0.08 and 0.20 mm in translation and between 0.20° and 0.43° for rotations. The radiation dose ranged between 0.2 and 2.3 mSv.Interpretation - CTMA achieved a clinically relevant and consistent precision between the 3 different hip cups studied. The use of different hip cup types, different CT scanners, or registration method (beads or surface anatomy) had no discernible effect on precision. Therefore, CTMA without the use of bone markers could potentially be an alternative to RSA to measure early migration.
  •  
23.
  • Engstrøm, Thomas, et al. (författare)
  • Danegaptide for primary percutaneous coronary intervention in acute myocardial infarction patients : A phase 2 randomised clinical trial
  • 2018
  • Ingår i: Heart. - : BMJ. - 1355-6037 .- 1468-201X. ; 104:19, s. 1593-1599
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Reperfusion immediately after reopening of the infarct-related artery in ST-segment elevation myocardial infarction (STEMI) may cause myocardial damage in addition to the ischaemic insult (reperfusion injury). The gap junction modulating peptide danegaptide has in animal models reduced this injury. We evaluated the effect of danegaptide on myocardial salvage in patients with STEMI. Methods: In addition to primary percutaneous coronary intervention in STEMI patients with thrombolysis in myocardial infarction flow 0-1, single vessel disease and ischaemia time less than 6 hours, we tested, in a clinical proof-of-concept study, the therapeutic potential of danegaptide at two-dose levels. Primary outcome was myocardial salvage evaluated by cardiac MRI after 3 months. Results: From November 2013 to August 2015, a total of 585 patients were randomly enrolled in the trial. Imaging criteria were fulfilled for 79 (high dose), 80 (low dose) and 84 (placebo) patients eligible for the per-protocol analysis. Danegaptide did not affect the myocardial salvage index (danegaptide high (63.9±14.9), danegaptide low (65.6±15.6) and control (66.7±11.7), P=0.40), final infarct size (danegaptide high (19.6±11.4 g), danegaptide low (18.6±9.6 g) and control (21.4±15.0 g), P=0.88) or left ventricular ejection fraction (danegaptide high (53.9%±9.5%), danegaptide low (52.7%±10.3%) and control (52.1%±10.9%), P=0.64). There was no difference between groups with regard to clinical outcome. Conclusions: Administration of danegaptide to patients with STEMI did not improve myocardial salvage. Trial registration number: NCT01977755; Pre-results.
  •  
24.
  • Ericson, Anne, et al. (författare)
  • Computed tomography analysis of radiostereometric data to determine flexion axes after total joint replacement : Application to the elbow joint
  • 2010
  • Ingår i: Journal of Biomechanics. - : Elsevier BV. - 0021-9290 .- 1873-2380. ; 43:10, s. 1947-1952
  • Tidskriftsartikel (refereegranskat)abstract
    • Kinematic analysis for in vivo assessment of elbow endoprostheses requires knowledge of the exact positions of motion axes relative to bony landmarks or the prosthesis. A prosthesis-based reference system is required for comparison between individuals and studies. The primary aim of this study was to further develop an earlier described algorithm for fusion of radiostereometric analysis (RSA) data and data obtained in 3D computed tomography (CT) for application to the elbow after total joint replacement. The secondary aim was to propose a method for marking of prostheses in 3D CT, enabling definition of a prosthesis-based reference system. Six patients with elbow endoprostheses were investigated. The fusion of data made it possible to visualize the motion axes in relation to the prostheses in the 3D CT volume. The differences between two repeated positioning repetitions of the longitudinal prosthesis axis were less than 0.6 degrees in the frontal and sagittal planes. Corresponding values for the transverse axis were less than 0.6 degrees in the frontal and less than 1.4 degrees (in four out of six less than 0.6 degrees) in the horizontal plane. This study shows that by fusion of CT and RSA data it is possible to determine the accurate position of the flexion axes of the elbow joint after total joint replacement in vivo. The proposed method for implant marking and registration of reference axes enables comparison of prosthesis function between patients and studies.
  •  
25.
  • Ericson, Anne, et al. (författare)
  • Fusion of radio stereometric analysis data into computed tomography space : Application to the elbow joint
  • 2007
  • Ingår i: Journal of Biomechanics. - Oxford, UK : Elsevier Science Ltd. - 0021-9290 .- 1873-2380. ; 40:2, s. 296-304
  • Tidskriftsartikel (refereegranskat)abstract
    • Improvement of joint prostheses is dependent upon information concerning the biomechanical properties of the joint. Radiostereometric analysis (RSA) and electromagnetic techniques have been applied in previous cadaver and in vivo studies on the elbow joint to provide valuable information concerning joint motion axes. However, such information is limited to mathematically calculated positions of the axes according to an orthogonal coordinate system and is difficult to relate to individual skeletal anatomy. The aim of this study was to evaluate the in vivo application of a new fusion method to provide three-dimensional (31)) visualization of flexion axes according to bony landmarks. In vivo RSA data of the elbow joint's flexion axes was combined with data obtained by 3D computed tomography (CT). Results were obtained from five healthy subjects after one was excluded due to an instable RSA marker. The median error between imported and transformed RSA marker coordinates and those obtained in the CT volume was 0.22mm. Median maximal rotation error after transformation of the rigid RSA body to the CT volume was 0.003 degrees. Points of interception with a plane calculated in the RSA orthogonal coordinate system were imported into the CT volume, facilitating the 3D visualization of the flexion axes. This study demonstrates a successful fusion of RSA and CT data, without significant loss of RSA accuracy. The method could be used for relating individual motion axes to a 3D representation of relevant joint anatomy, thus providing important information for clinical applications such as the development of joint prostheses.
  •  
26.
  • Eriksson, Thomas, et al. (författare)
  • Are low-dose CT scans a satisfactory substitute for stereoradiographs for migration studies? A preclinical test of low-dose CT scanning protocols and their application in a pilot patient.
  • 2019
  • Ingår i: Acta Radiologica. - : Sage Publications. - 0284-1851 .- 1600-0455.
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Computed tomography (CT) has the potential to acquire the data needed for migration studies of orthopedic joint implants of patients who have had tantalum beads implanted at the time of joint replacement surgery. This can be accomplished with the same precision as radiostereometric analysis (RSA). Switching to CT would increase availability without the need for the specific facilities required for RSA. However, higher effective dose is a concern.PURPOSE: To investigate if migration measurements can be done with CT with an accuracy and effective dose comparable to that of conventional RSA.MATERIAL AND METHODS: Fourteen scanning protocols were tested in a hip phantom that incorporated tantalum beads and an uncemented femoral stem. The protocols were graded for clinical practice according to the three parameters of image quality, effective dose, and robustness of numerical data. After grading, the two protocols that graded best overall were applied to a pilot patient.RESULTS: All protocols produced scans in which the numerical data were sufficient for a migration analysis at least as precise as would be expected using RSA. A protocol with an effective dose of 0.70 mSv was shown to be applicable in a pilot patient.CONCLUSION: Low-dose CT scans with an effective dose comparable to a set of routine plain radiographs can be used for precise migration measurements.
  •  
27.
  •  
28.
  •  
29.
  • Erlinge, David, et al. (författare)
  • Rapid Endovascular Catheter Core Cooling Combined With Cold Saline as an Adjunct to Percutaneous Coronary Intervention for the Treatment of Acute Myocardial Infarction The CHILL-MI Trial : A Randomized Controlled Study of the Use of Central Venous Catheter Core Cooling Combined With Cold Saline as an Adjunct to Percutaneous Coronary Intervention for the Treatment of Acute Myocardial Infarction
  • 2014
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097 .- 1558-3597. ; 63:18, s. 1857-1865
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives The aim of this study was to confirm the cardioprotective effects of hypothermia using a combination of cold saline and endovascular cooling. Background Hypothermia has been reported to reduce infarct size (IS) in patients with ST-segment elevation myocardial infarctions. Methods In a multicenter study, 120 patients with ST-segment elevation myocardial infarctions (<6 h) scheduled to undergo percutaneous coronary intervention were randomized to hypothermia induced by the rapid infusion of 600 to 2,000 ml cold saline and endovascular cooling or standard of care. Hypothermia was initiated before percutaneous coronary intervention and continued for 1 h after reperfusion. The primary end point was IS as a percent of myocardium at risk (MaR), assessed by cardiac magnetic resonance imaging at 4 +/- 2 days. Results Mean times from symptom onset to randomization were 129 +/- 56 min in patients receiving hypothermia and 132 +/- 64 min in controls. Patients randomized to hypothermia achieved a core body temperature of 34.7 degrees C before reperfusion, with a 9-min longer door-to-balloon time. Median IS/MaR was not significantly reduced (hypothermia: 40.5% [interquartile range: 29.3% to 57.8%; control: 46.6% [interquartile range: 37.8% to 63.4%]; relative reduction 13%; p = 0.15). The incidence of heart failure was lower with hypothermia at 45 +/- 15 days (3% vs. 14%, p < 0.05), with no mortality. Exploratory analysis of early anterior infarctions (0 to 4 h) found a reduction in IS/MaR of 33% (p < 0.05) and an absolute reduction of IS/left ventricular volume of 6.2% (p = 0.15). Conclusions Hypothermia induced by cold saline and endovascular cooling was feasible and safe, and it rapidly reduced core temperature with minor reperfusion delay. The primary end point of IS/MaR was not significantly reduced. Lower incidence of heart failure and a possible effect in patients with early anterior ST-segment elevation myocardial infarctions need confirmation. (Efficacy of Endovascular Catheter Cooling Combined With Cold Saline for the Treatment of Acute Myocardial Infarction [CHILL-MI]; NCT01379261)
  •  
30.
  • Erlinge, David, et al. (författare)
  • Therapeutic Hypothermia for the Treatment of Acute Myocardial Infarction-Combined Analysis of the RAPID MI-ICE and the CHILL-MI Trials
  • 2015
  • Ingår i: Therapeutic Hypothermia and Temperature Management. - : Mary Ann Liebert Inc. - 2153-7658 .- 2153-7933. ; 5:2, s. 77-84
  • Tidskriftsartikel (refereegranskat)abstract
    • In the randomized rapid intravascular cooling in myocardial infarction as adjunctive to percutaneous coronary intervention (RAPID MI-ICE) and rapid endovascular catheter core cooling combined with cold saline as an adjunct to percutaneous coronary intervention for the treatment of acute myocardial infarction CHILL-MI studies, hypothermia was rapidly induced in conscious patients with ST-elevation myocardial infarction (STEMI) by a combination of cold saline and endovascular cooling. Twenty patients in RAPID MI-ICE and 120 in CHILL-MI with large STEMIs, scheduled for primary percutaneous coronary intervention (PCI) within <6 hours after symptom onset were randomized to hypothermia induced by rapid infusion of 600-2000mL cold saline combined with endovascular cooling or standard of care. Hypothermia was initiated before PCI and continued for 1-3 hours after reperfusion aiming at a target temperature of 33 degrees C. The primary endpoint was myocardial infarct size (IS) as a percentage of myocardium at risk (IS/MaR) assessed by cardiac magnetic resonance imaging at 4 +/- 2 days. Patients randomized to hypothermia treatment achieved a mean core body temperature of 34.7 degrees C before reperfusion. Although significance was not achieved in CHILL-MI, in the pooled analysis IS/MaR was reduced in the hypothermia group, relative reduction (RR) 15% (40.5, 28.0-57.6 vs. 46.6, 36.8-63.8, p=0.046, median, interquartile range [IQR]). IS/MaR was predominantly reduced in early anterior STEMI (0-4h) in the hypothermia group, RR=31% (40.5, 28.8-51.9 vs. 59.0, 45.0-67.8, p=0.01, median, IQR). There was no mortality in either group. The incidence of heart failure was reduced in the hypothermia group (2 vs. 11, p=0.009). Patients with large MaR (>30% of the left ventricle) exhibited significantly reduced IS/MaR in the hypothermia group (40.5, 27.0-57.6 vs. 55.1, 41.1-64.4, median, IQR; hypothermia n=42 vs. control n=37, p=0.03), while patients with MaR<30% did not show effect of hypothermia (35.8, 28.3-57.5 vs. 38.4, 27.4-59.7, median, IQR; hypothermia n=15 vs. control n=19, p=0.50). The prespecified pooled analysis of RAPID MI-ICE and CHILL-MI indicates a reduction of myocardial IS and reduction in heart failure by 1-3 hours with endovascular cooling in association with primary PCI of acute STEMI predominantly in patients with large area of myocardium at risk. (ClinicalTrials.gov id NCT00417638 and NCT01379261).
  •  
31.
  • Götberg, Matthias, et al. (författare)
  • A Pilot Study of Rapid Cooling by Cold Saline and Endovascular Cooling Before Reperfusion in Patients With ST-Elevation Myocardial Infarction.
  • 2010
  • Ingår i: Circulation. Cardiovascular Interventions. - 1941-7632. ; 3, s. 400-407
  • Tidskriftsartikel (refereegranskat)abstract
    • Background-Experimental studies have shown that induction of hypothermia before reperfusion of acute coronary occlusion reduces infarct size. Previous clinical studies, however, have not been able to show this effect, which is believed to be mainly because therapeutic temperature was not reached before reperfusion in the majority of the patients. We aimed to evaluate the safety and feasibility of rapidly induced hypothermia by infusion of cold saline and endovascular cooling catheter before reperfusion in patients with acute myocardial infarction. METHODS AND RESULTS: =0.12). Despite similar duration of ischemia (174+/-51 minutes versus 174+/-62 minutes, hypothermia versus control, P=1.00), infarct size normalized to myocardium at risk was reduced by 38% in the hypothermia group compared with the control group (29.8+/-12.6% versus 48.0+/-21.6%, P=0.041). This was supported by a significant decrease in both peak and cumulative release of Troponin T in the hypothermia group (P=0.01 and P=0.03, respectively). Conclusions-The protocol demonstrates the ability to reach a core body temperature of <35 degrees C before reperfusion in all patients without delaying primary percutaneous coronary intervention and that combination hypothermia as an adjunct therapy in acute myocardial infarction may reduce infarct size at 3 days as measured by MRI. Clinical Trial Registration-URL: http://clinicaltrials.gov. Unique identifier: NCT00417638.
  •  
32.
  • Götberg, Matthias, et al. (författare)
  • Optimal timing of hypothermia in relation to myocardial reperfusion.
  • 2011
  • Ingår i: Basic Research in Cardiology. - : Springer Science and Business Media LLC. - 1435-1803 .- 0300-8428. ; 106, s. 697-708
  • Tidskriftsartikel (refereegranskat)abstract
    • Two previous clinical trials investigating hypothermia as an adjunct therapy for myocardial infarction have failed. Recently a pilot study has demonstrated a significant reduction in infarct size. The aims of this study were to elucidate the effects of hypothermia on reperfusion injury and to investigate the optimal hypothermia protocol for a future clinical trial. Pigs (40-50 kg) were anesthetized and a normal pig temperature of 38°C was established utilizing an endovascular temperature modulating catheter. The pigs were randomized to a combination hypothermia group (1,000 ml of 4°C saline solution and endovascular cooling, n = 8), or to normothermic controls (n = 8). A PCI balloon was then inflated in the LAD for 40 min (control) or 45 min with hypothermia induced during the last 5 min. Furthermore, hypothermia induced by cold saline alone (n = 8), and prolonged combination hypothermia during reperfusion (n = 7) were also examined. Infarct size and area at risk were determined ex vivo after 4 h of reperfusion using gadolinium-enhanced MRI and Tc-99-tetrofosmin SPECT, respectively. All pigs in the combination hypothermia group were cooled to <35°C within 5 min. Combination hypothermia reduced IS/AAR by 18% compared with normothermic controls despite 5 min longer ischemic time (61 ± 5 vs. 74 ± 4%, p = 0.03). Cold saline did not reduce IS/AAR. Prolonging hypothermia treatment after onset of reperfusion by an additional 45 min over that used in a previous paper did not confer any additional benefit. The cardioprotective effects of hypothermia treatment are due to an attenuation of myocardial injury during both ischemia and reperfusion. The results suggest that a hypothermia protocol using a cold saline infusion and endovascular cooling enables hypothermia to be induced in a clinical setting without delaying reperfusion therapy.
  •  
33.
  • Götberg, Matthias, et al. (författare)
  • Rapid short-duration hypothermia with cold saline and endovascular cooling before reperfusion reduces microvascular obstruction and myocardial infarct size.
  • 2008
  • Ingår i: BMC Cardiovascular Disorders. - : Springer Science and Business Media LLC. - 1471-2261. ; 8:Apr 10
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The aim of this study was to evaluate the combination of a rapid intravenous infusion of cold saline and endovascular hypothermia in a closed chest pig infarct model. METHODS: Pigs were randomized to pre-reperfusion hypothermia (n = 7), post-reperfusion hypothermia (n = 7) or normothermia (n = 5). A percutaneous coronary intervention balloon was inflated in the left anterior descending artery for 40 min. Hypothermia was started after 25 min of ischemia or immediately after reperfusion by infusion of 1000 ml of 4 degrees C saline and endovascular hypothermia. Area at risk was evaluated by in vivo SPECT. Infarct size was evaluated by ex vivo MRI. RESULTS: Pre-reperfusion hypothermia reduced infarct size/area at risk by 43% (46 +/- 8%) compared to post-reperfusion hypothermia (80 +/- 6%, p < 0.05) and by 39% compared to normothermia (75 +/- 5%, p < 0.05). Pre-reperfusion hypothermia infarctions were patchier in appearance with scattered islands of viable myocardium. Pre-reperfusion hypothermia abolished (0%, p < 0.001), and post-reperfusion hypothermia significantly reduced microvascular obstruction (10.3 +/- 5%; p < 0.05), compared to normothermia: (30.2 +/- 5%). CONCLUSION: Rapid hypothermia with cold saline and endovascular cooling before reperfusion reduces myocardial infarct size and microvascular obstruction. A novel finding is that hypothermia at the onset of reperfusion reduces microvascular obstruction without reducing myocardial infarct size. Intravenous administration of cold saline combined with endovascular hypothermia provides a method for a rapid induction of hypothermia suggesting a potential clinical application.
  •  
34.
  •  
35.
  • Heiberg, Einar, et al. (författare)
  • Automated quantification of myocardial infarction from MR images by accounting for partial volume effects: animal, phantom, and human study.
  • 2008
  • Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 1527-1315 .- 0033-8419. ; 246:2, s. 581-588
  • Tidskriftsartikel (refereegranskat)abstract
    • Ethics committees approved human and animal study components; informed written consent was provided (prospective human study [20 men; mean age, 62 years]) or waived (retrospective human study [16 men, four women; mean age, 59 years]). The purpose of this study was to prospectively evaluate a clinically applicable method, accounting for the partial volume effect, to automatically quantify myocardial infarction from delayed contrast material-enhanced magnetic resonance images. Pixels were weighted according to signal intensity to calculate infarct fraction for each pixel. Mean bias +/- variability (or standard deviation), expressed as percentage left ventricular myocardium (%LVM), were -0.3 +/- 1.3 (animals), -1.2 +/- 1.7 (phantoms), and 0.3 +/- 2.7 (patients), respectively. Algorithm had lower variability than dichotomous approach (2.7 vs 7.7 %LVM, P < .01) and did not differ from interobserver variability for bias (P = .31) or variability (P = .38). The weighted approach provides automatic quantification of myocardial infarction with higher accuracy and lower variability than a dichotomous algorithm.
  •  
36.
  • Jedenmalm, Anneli, et al. (författare)
  • Validation of a 3D CT method for measurement of linear wear of acetabular cups : A hip simulator study
  • 2011
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 82:1, s. 35-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17 degrees A degrees. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.
  •  
37.
  •  
38.
  • Jolly, Sanjit S., et al. (författare)
  • Thrombus Aspiration in ST Elevation Myocardial Infarction : An Individual Patient Meta-analysis
  • 2017
  • Ingår i: Circulation. - 0009-7322. ; 135, s. 143-152
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND—: Thrombus aspiration during percutaneous coronary intervention (PCI) for the treatment of ST elevation myocardial infarction (STEMI) has been widely used; however, recent trials have questioned its value and safety. In this meta-analysis, we, the trial investigators, aimed to pool the individual patient data from these trials to determine the benefits and risks of thrombus aspiration during PCI in patients with STEMI. METHODS—: Included were large (N≥1000) randomized controlled trials comparing manual thrombectomy vs. PCI alone in patients with STEMI. Individual patient data was provided by the leadership of each trial. The pre-specified primary efficacy outcome was cardiovascular (CV) mortality within 30 days and the primary safety outcome was stroke or transient ischemic attack (TIA) within 30 days. RESULTS—: The 3 eligible randomized trials (TAPAS, TASTE and TOTAL) enrolled 19,047 patients, of whom 18,306 underwent PCI and were included in the primary analysis. CV death at 30 days occurred in 221 (2.4%) of 9155 patients randomized to thrombus aspiration and 262 (2.9%) of 9151 randomized to PCI alone (hazard ratio (HR) 0.84; 95% CI 0.70-1.01, p=0.06). Stroke or TIA occurred in 66 (0.8%) randomized to thrombus aspiration and 46 (0.5%) randomized to PCI alone (odds ratio [OR] 1.43 95% CI 0.98-2.1, p=0.06). There were no significant differences in recurrent myocardial infarction, stent thrombosis, heart failure or target vessel revascularization. In the subgroup with high thrombus burden (TIMI thrombus grade ≥3) thrombus aspiration was associated with less CV death (170 [2.5%] vs. 205 [3.1%] HR 0.80; 95% CI 0.65-0.98, p =0.03), and with more stroke or TIA (55 [0.9%] vs. 34 [0.5%] OR 1.56; 95% CI 1.02-2.42, p=0.04). However, the interaction p-values were 0.32 and 0.34, respectively. CONCLUSIONS—: Routine thrombus aspiration during STEMI PCI did not improve clinical outcomes. In the high thrombus burden subgroup the trends toward reduced CV death and increased stroke or TIA provide a rationale for future trials of improved thrombus aspiration technologies in this high-risk subgroup. CLINICAL TRIAL REGISTRATION—: ClinicalTrials.gov identifier NCT02552407, PROSPERO CRD42015025936
  •  
39.
  • Jolly, Sanjit S., et al. (författare)
  • Thrombus Aspiration in ST-Segment-Elevation Myocardial Infarction An Individual Patient Meta-Analysis : Thrombectomy Trialists Collaboration
  • 2017
  • Ingår i: Circulation. - 0009-7322 .- 1524-4539. ; 135:2, s. 143-
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Thrombus aspiration during percutaneous coronary intervention (PCI) for the treatment of ST-segment-elevation myocardial infarction (STEMI) has been widely used; however, recent trials have questioned its value and safety. In this meta-analysis, we, the trial investigators, aimed to pool the individual patient data from these trials to determine the benefits and risks of thrombus aspiration during PCI in patients with ST-segment-elevation myocardial infarction. METHODS: Included were large (n >= 1000), randomized, controlled trials comparing manual thrombectomy and PCI alone in patients with ST-segment-elevation myocardial infarction. Individual patient data were provided by the leadership of each trial. The prespecified primary efficacy outcome was cardiovascular mortality within 30 days, and the primary safety outcome was stroke or transient ischemic attack within 30 days. RESULTS: The 3 eligible randomized trials (TAPAS [Thrombus Aspiration During Percutaneous Coronary Intervention in Acute Myocardial Infarction], TASTE [Thrombus Aspiration in ST-Elevation Myocardial Infarction in Scandinavia], and TOTAL [Trial of Routine Aspiration Thrombectomy With PCI Versus PCI Alone in Patients With STEMI]) enrolled 19 047 patients, of whom 18 306 underwent PCI and were included in the primary analysis. Cardiovascular death at 30 days occurred in 221 of 9155 patients (2.4%) randomized to thrombus aspiration and 262 of 9151 (2.9%) randomized to PCI alone (hazard ratio, 0.84; 95% confidence interval, 0.70-1.01; P=0.06). Stroke or transient ischemic attack occurred in 66 (0.8%) randomized to thrombus aspiration and 46 (0.5%) randomized to PCI alone (odds ratio, 1.43; 95% confidence interval, 0.98-2.10; P=0.06). There were no significant differences in recurrent myocardial infarction, stent thrombosis, heart failure, or target vessel revascularization. In the subgroup with high thrombus burden (TIMI [Thrombolysis in Myocardial Infarction] thrombus grade >= 3), thrombus aspiration was associated with fewer cardiovascular deaths (170 [2.5%] versus 205 [3.1%]; hazard ratio, 0.80; 95% confidence interval, 0.65-0.98; P=0.03) and with more strokes or transient ischemic attacks (55 [0.9%] versus 34 [0.5%]; odds ratio, 1.56; 95% confidence interval, 1.02-2.42, P=0.04). However, the interaction P values were 0.32 and 0.34, respectively. CONCLUSIONS: Routine thrombus aspiration during PCI for ST-segment-elevation myocardial infarction did not improve clinical outcomes. In the high thrombus burden group, the trends toward reduced cardiovascular death and increased stroke or transient ischemic attack provide a rationale for future trials of improved thrombus aspiration technologies in this high-risk subgroup.
  •  
40.
  • Krarup, Niels Henrik, et al. (författare)
  • Quality of cardiopulmonary resuscitation in out-of-hospital cardiac arrest is hampered by interruptions in chest compressions-A nationwide prospective feasibility study
  • 2011
  • Ingår i: Resuscitation. - : Elsevier BV. - 1873-1570 .- 0300-9572. ; 82:3, s. 263-269
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim of the study: Quality of cardiopulmonary resuscitation (CPR) is a critical determinant of outcome following out-of-hospital cardiac arrest. The aim of our study was to evaluate the quality of CPR provided by emergency medical service providers (Basic Life Support (BLS) capability) and emergency medical service providers assisted by paramedics, nurse anesthetists or physician-manned ambulances (Advanced Life Support (ALS) capability) in a nationwide, unselected cohort of out-of-hospital cardiac arrest cases. Methods: We conducted a prospective, observational study of out-of-hospital cardiac arrest with non-traumatic etiology (>18 years of age) occurring from the 1st to the 31st of January 2009 and treated by the primary Danish emergency medical service operator, covering approximately 85% of the population. One hundred and ninety-one cases were eligible for analysis. Follow-up was up to one year or death. Quality of CPR was evaluated using measurements of transthoracic impedance. Results: The majority of patients were treated by ambulances with ALS capability (54%). Interruptions in CPR related to loading of the patient into the emergency medical service vehicle were substantial, but independent of whether patients were managed by ALS or BLS capable units (222s versus 224s, P=0.76) as were duration of interruptions during rhythm analysis alone (20s versus 22s, P=0.33) and defibrillation (24s versus 26s, P=0.07). Conclusions: Nationwide, routine monitoring of transthoracic impedance is feasible. CPR is hampered by extended interruptions, particularly during loading of the patient into the emergency medical service vehicle, rhythm analysis and defibrillation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
  •  
41.
  • Lundqvist, Eva, 1985-, et al. (författare)
  • CT-Based Micromotion Analysis After Locking Plate Fixation of AO Type C Distal Radius Fractures
  • 2023
  • Ingår i: Indian Journal of Orthopaedics. - : Springer. - 0019-5413 .- 1998-3727. ; 57:12, s. 2031-2039
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Volar locking plate fixation (VLPF) is the most common method for operative fixation of distal radius fractures (DRF). The dorsal ulnar corner (DUC) can be difficult to stabilize as the fragment is small and not exposed when using the volar approach. The purpose of this study was to study fracture fragment migration after VLPF of AO type C DRF, using a volume registration technique of paired CT scans with special focus on the DUC fragment.Materials and Methods: This pilot study included ten patients with AO type C DRF, all operated with VLPF. The primary outcome was radiographic outcome. Postoperative and 1-year scans were compared and analyzed. Fragment migration was assessed with CT-based micromotion analysis (CTMA), a software technique used for volume registration of paired CT scans.Results: All plates were stable over time. Two patients showed signs of screw movement (0.2-0.35 mm and 0.35- > 1 mm respectively). Postoperative reduction was maintained, and there was no fragment migration at the 1-year follow-up except for one case with increased dorsal tilt. The DUC fragment was found in 8/10 cases, fixated in 7/8 cases, and not dislocated in any case at the 1-year follow-up.Conclusion: The CTMA results indicate that variable-angle VLPF after AO type C DRF can yield and maintain a highly stable reduction of the fracture fragments. The DUC fragment remained stable regardless of the number of screws through the fragment. CT volume registration can be a valuable tool in the detailed assessment of fracture fragment migration following volar plate fixation of DRFs.
  •  
42.
  •  
43.
  •  
44.
  • Maguire Jr., Gerald Q., et al. (författare)
  • A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner : Method and Analysis
  • 2014
  • Ingår i: Scientific World Journal. - : Hindawi Limited. - 1537-744X .- 2356-6140. ; 2014, s. 528407-
  • Tidskriftsartikel (refereegranskat)abstract
    • As the most advantageous total hip arthroplasty (THA) operation is the first, timely replacement of only the liner is socially and economically important because the utilization of THA is increasing as younger and more active patients are receiving implants and they are living longer. Automatic algorithms were developed to infer liner wear by estimating the separation between the acetabular cup and femoral component head given a computed tomography (CT) volume. Two series of CT volumes of a hip phantom were acquired with the femoral component head placed at 14 different positions relative to the acetabular cup. The mean and standard deviation (SD) of the diameter of the acetabular cup and femoral component head, in addition to the range of error in the expected wear values and the repeatability of all the measurements, were calculated. The algorithms resulted in a mean (+/- SD) for the diameter of the acetabular cup of 54.21 (+/- 0.011) mm and for the femoral component head of 22.09 (+/- 0.02) mm. The wear error was +/- 0.1 mm and the repeatability was 0.077 mm. This approach is applicable clinically as it utilizes readily available computed tomography imaging systems and requires only five minutes of human interaction.
  •  
45.
  • Mahmoud, Karim D., et al. (författare)
  • Clinical impact of direct stenting and interaction with thrombus aspiration in patients with ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention : Thrombectomy Trialists Collaboration
  • 2018
  • Ingår i: European Heart Journal. - : Oxford University Press. - 0195-668X .- 1522-9645. ; 39:26, s. 2472-2479
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Preliminary studies suggest that direct stenting (DS) during percutaneous coronary intervention (PCI) may reduce microvascular obstruction and improve clinical outcome. Thrombus aspiration may facilitate DS. We assessed the impact of DS on clinical outcome and myocardial reperfusion and its interaction with thrombus aspiration among ST-segment elevation myocardial infarction (STEMI) patients undergoing PCI.Methods and results: Patient-level data from the three largest randomized trials on routine manual thrombus aspiration vs. PCI only were merged. A 1:1 propensity matched population was created to compare DS and conventional stenting. Synergy between DS and thrombus aspiration was assessed with interaction P-values in the final models. In the unmatched population (n= 17329), 32% underwent DS and 68% underwent conventional stenting. Direct stenting rates were higher in patients randomized to thrombus aspiration as compared with PCI only (41% vs. 22%; P < 0.001). Patients undergoing DS required less contrast (162 mL vs. 172 mL; P < 0.001) and had shorter fluoroscopy time (11.1 min vs. 13.3 min; P < 0.001). After propensity matching (n = 10944), no significant differences were seen between DS and conventional stenting with respect to 30-day cardiovascular death [1.7% vs. 1.9%; hazard ratio 0.88, 95% confidence interval (CI) 0.55-1.41; P=0.60; P-interaction = 0.96) and 30-day stroke or transient ischaemic attack (0.6% vs. 0.4%; odds ratio 1.02; 95% CI 0.14-7.54; P= 0.99; P-interaction = 0.81). One-year results were similar. No significant differences were seen in electrocardiographic and angiographic myocardial reperfusion measures.Conclusion: Direct stenting rates were higher in patients randomized to thrombus aspiration. Clinical outcomes and myocardial reperfusion measures did not differ significantly between DS and conventional stenting and there was no interaction with thrombus aspiration.
  •  
46.
  • Mannerås Holm, Louise, 1980, et al. (författare)
  • Adipose tissue has aberrant morphology and function in PCOS: enlarged adipocytes and low serum adiponectin, but not circulating sex steroids, are strongly associated with insulin resistance.
  • 2011
  • Ingår i: The Journal of clinical endocrinology and metabolism. - : The Endocrine Society. - 1945-7197 .- 0021-972X. ; 96:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Context: Comprehensive characterization of the adipose tissue in women with polycystic ovary syndrome (PCOS), over a wide range of body mass indices (BMIs), is lacking. Mechanisms behind insulin resistance in PCOS are unclear. Objective: To characterize the adipose tissue of women with PCOS and controls matched pair-wise for age and BMI, and to identify factors, among adipose tissue characteristics and serum sex steroids, that are associated with insulin sensitivity in PCOS. Design/Outcome Measures: Seventy-four PCOS women and 31 controls were included. BMI was 18-47 (PCOS) and 19-41 kg/m2 (controls). Anthropometric variables, volumes of subcutaneous/visceral adipose tissue (magnetic resonance imaging; MRI), and insulin sensitivity (clamp) were investigated. Adipose tissue biopsies were obtained to determine adipocyte size, lipoprotein lipase (LPL) activity, and macrophage density. Circulating testosterone, free testosterone, free 17β-estradiol, SHBG, glycerol, adiponectin, and serum amyloid A were measured/calculated. Results: Comparison of 31 pairs revealed lower insulin sensitivity, hyperandrogenemia, and higher free 17β-estradiol in PCOS. Abdominal adipose tissue volumes/distribution did not differ in the groups, but PCOS women had higher waist-to-hip ratio, enlarged adipocytes, reduced adiponectin, and lower LPL activity. In regression analysis, adipocyte size, adiponectin, and waist circumference were the factors most strongly associated with insulin sensitivity in PCOS (R2=0.681, P < 0.001). Conclusions: In PCOS, adipose tissue has aberrant morphology/function. Increased waist-to-hip ratio indicates abdominal/visceral fat accumulation, but this is not supported by MRI. Enlarged adipocytes and reduced serum adiponectin, together with a large waistline, rather than androgen excess, may be central factors in the pathogenesis/maintenance of insulin resistance in PCOS.
  •  
47.
  • Nordström, Carl-Henrik, et al. (författare)
  • Aspects on the Physiological and Biochemical Foundations of Neurocritical Care
  • 2017
  • Ingår i: Frontiers in Neurology. - : Frontiers Media S.A.. - 1664-2295. ; 8
  • Forskningsöversikt (refereegranskat)abstract
    • Neurocritical care (NCC) is a branch of intensive care medicine characterized by specific physiological and biochemical monitoring techniques necessary for identifying cerebral adverse events and for evaluating specific therapies. Information is primarily obtained from physiological variables related to intracranial pressure (ICP) and cerebral blood flow (CBF) and from physiological and biochemical variables related to cerebral energy metabolism. Non-surgical therapies developed for treating increased ICP are based on knowledge regarding transport of water across the intact and injured blood-brain barrier (BBB) and the regulation of CBF. Brain volume is strictly controlled as the BBB permeability to crystalloids is very low restricting net transport of water across the capillary wall. Cerebral pressure autoregulation prevents changes in intracranial blood volume and intracapillary hydrostatic pressure at variations in arterial blood pressure. Information regarding cerebral oxidative metabolism is obtained from measurements of brain tissue oxygen tension (PbtO2) and biochemical data obtained from intracerebral microdialysis. As interstitial lactate/pyruvate (LP) ratio instantaneously reflects shifts in intracellular cytoplasmatic redox state, it is an important indicator of compromised cerebral oxidative metabolism. The combined information obtained from PbtO2, LP ratio, and the pattern of biochemical variables reveals whether impaired oxidative metabolism is due to insufficient perfusion (ischemia) or mitochondrial dysfunction. Intracerebral microdialysis and PbtO2 give information from a very small volume of tissue. Accordingly, clinical interpretation of the data must be based on information of the probe location in relation to focal brain damage. Attempts to evaluate global cerebral energy state from microdialysis of intraventricular fluid and from the LP ratio of the draining venous blood have recently been presented. To be of clinical relevance, the information from all monitoring techniques should be presented bedside online. Accordingly, in the future, the chemical variables obtained from microdialysis will probably be analyzed by biochemical sensors.
  •  
48.
  • Nyrén, Rakel, 1986-, et al. (författare)
  • Visualizing increased uptake of [18F]FDG and [18F]FTHA in kidneys from obese high-fat diet fed C57BL/6J mice using PET/CT ex vivo
  • 2023
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 18
  • Tidskriftsartikel (refereegranskat)abstract
    • It is known that high-fat diet (HFD) and/or diabetes may influence substrate preferences and energy demands in the heart preceding diabetic cardiomyopathy. They may also induce structural glomerular changes causing diabetic nephropathy. PET/CT has been utilized to examine uptake of energy substrates, and to study metabolic changes or shifts before onset of metabolic disorders. However, conventional PET/CT scanning of organs with relatively low uptake, such as the kidney, in small animals in vivo may render technical difficulties. To address this issue, we developed a PET/CT ex vivo protocol with radiolabeled glucose and fatty acid analouges, [18F]FDG and [18F]FTHA,to study substrate uptake in mouse kidneys. We also aimed to detect a possible energy substrate shift before onset of diabetic nephropathy. The ex vivo protocol reduced interfering background as well as interindividual variances. We found increased uptake of [18F]FDG and [18F]FTHA in kidneys after HFD, compared to kidneys from young mice on standard chow. Levels of kidney triglycerides also increased on HFD. Lipoprotein lipase (LPL) activity, the enzyme responsible for release of fatty acids from circulating lipoproteins, is normally increased in postprandial mice kidneys. After long-term HFD, we found that LPL activity was suppressed, and could therefore not explain the increased levels of stored triglycerides. Suppressed LPL activity was associated with increased expression of angiopoietin-like protein4, an inhibitor of LPL. HFD did not alter the transcriptional control of some common glucose and fatty acid transporters that may mediate uptake of [18F]FDG and [18F]FTHA. Performing PET/CT ex vivo reduced interfering background and interindividual variances. Obesity and insulin resistance induced by HFD increased the uptake of [18F]FDG and [18F]FTHA and triglyceride accumulation in mouse kidneys. Increased levels of [18F]FDG and [18F]FTHA in obese insulin resistant mice could be used clinically as an indicator of poor metabolic control, and a complementary test for incipient diabetic nephropathy.
  •  
49.
  •  
50.
  • Olivecrona, Henrik, et al. (författare)
  • A CT method for following patients with both prosthetic replacement and implanted tantalum beads : preliminary analysis with a pelvic model and in seven patients
  • 2016
  • Ingår i: Journal of Orthopaedic Surgery and Research. - : BioMed Central (BMC). - 1749-799X. ; 11
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Radiostereometric analysis (RSA) is often used for evaluating implanted devices over time. Following patients who have had tantalum beads implanted as markers in conjunction with joint replacements is important for longitudinal evaluation of these patients and for those with similar implants. As doing traditional RSA imaging is exacting and limited to specialized centers, it is important to consider alternative techniques for this ongoing evaluation. This paper studies the use of computed tomography (CT) to evaluate over time tantalum beads which have been implanted as markers. Methods: The project uses both a hip model implanted with tantalum beads, acquired in several orientations, at two different CT energy levels, and a cohort of seven patients. The model was evaluated twice by the same observer with a 1-week interval. All CT volumes were analyzed using a semi-automated 3D volume fusion (spatial registration) tool which provides landmark-based fusion of two volumes, registering a target volume with a reference volume using a rigid body 3D algorithm. The mean registration errors as well as the accuracy and repeatability of the method were evaluated. Results: The mean registration error, maximum value of repeatability, and accuracy for the relative movement in the model were 0.16 mm, 0.02 degrees and 0.1 mm, and 0.36 degrees and 0.13 mm for 120 kVp and 0.21 mm, 0.04 degrees and 0.01 mm, and 0.39 degrees and 0.12 mm for 100 kVp. For the patients, the mean registration errors per patient ranged from 0.08 to 0.35 mm. These results are comparable to those in typical clinical RSA trials. This technique successfully evaluated two patients who would have been lost from the cohort if only RSA were used. Conclusions: The proposed technique can be used to evaluate patients with tantalum beads over time without the need for stereoradiographs. Further, the effective dose associated with CT is decreasing.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-50 av 78
Typ av publikation
tidskriftsartikel (67)
konferensbidrag (6)
annan publikation (3)
doktorsavhandling (1)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (69)
övrigt vetenskapligt/konstnärligt (9)
Författare/redaktör
Olivecrona, Henrik (45)
Noz, Marilyn E. (33)
Zeleznik, Michael P. (28)
Maguire Jr., Gerald ... (23)
Olivecrona, Göran (20)
Götberg, Matthias (12)
visa fler...
Erlinge, David (11)
Engblom, Henrik (11)
Olivecrona, Lotta (11)
Harnek, Jan (11)
Arheden, Håkan (9)
Ugander, Martin (8)
Wagner, Henrik (7)
Carlsson, Marcus (6)
Clemmensen, Peter (6)
Stark, Andreas (6)
Koul, Sasha (5)
Maguire, Gerald Q. J ... (5)
Lassen, Jens Flenste ... (5)
Olivecrona, Gunilla (5)
Stankovic, Goran (5)
Brodén, Cyrus (5)
Wretenberg, Per, 196 ... (4)
Jedenmalm, Anneli (4)
Rundgren, Malin (4)
Hardig, Bjarne Madse ... (4)
Sandberg, Olof (3)
Wallentin, Lars (3)
James, Stefan (3)
Heiberg, Einar (3)
Aspelin, Peter (3)
Cairns, John A. (3)
Jonson, T (3)
Lundqvist, Eva, 1985 ... (3)
vanderPals, Jesper (3)
Olivecrona, Göran K. (3)
Sagerfors, Marcus, M ... (3)
Gao, Peggy (3)
Jensen, Ulf (3)
Emery, Roger (3)
Olivecrona, Goran K. (3)
Crafoord, Joakim (3)
Noc, Marko (3)
Holzer, Michael (3)
Zijlstra, Felix (3)
Kedev, Sasko (3)
Metzler, Bernhard (3)
Maguire Jr., Gerald ... (3)
Lang, Irene (3)
Botker, Hans Erik (3)
visa färre...
Lärosäte
Karolinska Institutet (38)
Kungliga Tekniska Högskolan (33)
Lunds universitet (27)
Uppsala universitet (13)
Umeå universitet (8)
Göteborgs universitet (6)
visa fler...
Örebro universitet (6)
Chalmers tekniska högskola (2)
Mittuniversitetet (1)
Högskolan i Borås (1)
visa färre...
Språk
Engelska (78)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (70)
Teknik (3)
Naturvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy