SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Papadouri T) "

Sökning: WFRF:(Papadouri T)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Carbajal, Ricardo, et al. (författare)
  • Pain Assessment in Ventilated and Non-Ventilated Neonates in NICUs across Europe : EUROpean Pain Audit in Neonates (EUROPAIN Survey)
  • 2014
  • Konferensbidrag (refereegranskat)abstract
    • Background: Neonates undergo many painful procedures during their NICU stay. These may include tracheal intubation/ventilation, skin-breaking procedures, drainage/suctioning of body orifices or cavities. Inherent subjectivity and difficulties of neonatal pain assessment contribute to a wide variety of assessment tools and clinical practices. To date, these practices have been not studied at a large scale. OBJECTIVE: To determine current clinical practices for neonatal pain assessment in NICUs across Europe. DESIGN/METHODS: An epidemiological observational study on bedside pain assessment practices collected data for all neonates in participating NICUs until infants left the unit (discharge, death, transfer to another hospital) or for 28 days. Data collection occurred via an online database for 1 month at each NICU. All neonates up to a gestational age of 44 weeks were included. RESULTS: From October 2012 to June 2013, 243 NICUs from 18 European countries collected pain assessment data in 6680 neonates. Of these, 2142 received tracheal ventilation (ventilated) and 4538 had spontaneous breathing or non- invasive ventilation (non-ventilated). The median (IQR) gestational age of ventilated neonates [32.1 (28.1-37.4)] was less than non-ventilated neonates [36.6 (33.6-39.1), p<0.001]. Overall, 58.5% of ventilated neonates and 35.2%% of non-ventilated neonates received bedside pain assessments (p<0.001). CONCLUSIONS: Over half (58.5%) of ventilated neonates and about one third (35.2%) of non-ventilated neonates had pain assessments performed in European NICUs. Wide variations in the methods used and rates of pain assessment exist among countries 
  •  
2.
  • Carbajal, Ricardo, et al. (författare)
  • Pain Assessment in Ventilated and Non-Ventilated Neonates in NICUS across Europe : Results from the EUROPAIN Study
  • 2016
  • Konferensbidrag (refereegranskat)abstract
    • Aim of Investigation: Pain from invasive or noninvasive procedures, mechanical ventilation, or painful medical and surgical conditions is commonplace in neonatal intensive care units (NICUs). While prevention and treatment of neonatal pain seem essential, an adequate analgesic approach cannot be implemented without relevant and timely pain assessments. Data on neonatal pain assessment practices are scarce, with undefined best practices or clinical benefits. We aimed to describe pain assessment practices in 243 NICUs from 18 European countries and to examine the NICU and patient characteristics influencing pain assessments at the bedside.Methods: Demographic data, modes of respiration, use of sedation, analgesia, or neuromuscular blockers, frequency and types of pain assessments were recorded for all newborns during the first 28 days of NICU admission. Multivariable models tested the associations between the performance of pain assessments and center and neonatal factors.Results: Among 6648 neonates enrolled, highest level of ventilation during the study period classified patients into tracheal ventilation (TV, n=2138 [32%]), non-invasive ventilation (NIV, n=1493 [23%]), and spontaneous ventilation groups (SV, n=3017 [45%]). Pain assessments were performed in 1250 (58%), 672 (45%), and 916 (30%) of these groups respectively (p<0.001). Using data from 78,742 patient-days, we found that 2,838 (43%) neonates received 4.3 (5.2) pain assessments per neonate and per day (median (IQR): 2.4 (1-5)), whereas 3810 (57%) neonates did not receive any pain assessments. Pain assessments occurred on every day of the NICU stay in 461/2138 (22%) TV patients, 236/1493 (16%) NIV patients, and 393/3016 (13%) SV patients (p<0.001).Many different pain assessment methods were used; the EDIN scale was used most frequently (42.3% among those who had at least one pain assessment). We analysed 33,625 patient-days in the TV group to test for associations between pain assessment and the use of opioids, sedatives-hypnotics, or general anaesthetics (O-SH-GA). The rates of pain assessments on patient-days with and without O-SH-GA use were, respectively, 57% vs. 43% while receiving mechanical ventilation, and 60% vs. 34% while not receiving mechanical ventilation (both p<0.001). Multivariable analyses showed that NICU-based guidelines, nursing leadership, and increased surgical admissions promoted the use of routine pain assessments (p<0.001). More pain assessments were performed in newborns below 32-weeks gestational age, those with decreased severity of illness, those already intubated at admission, those requiring mechanical or non-invasive ventilation, or surgery, or use of O-SH-GA.Conclusion: Even though pain is considered the 5th vital sign, only 43% of NICU neonates received bedside pain assessments. Clinical practice variability and low rates of pain assessments in NICUS may reflect weaknesses in the current paradigm used for neonatal pain assessments, their subjectivity, lack of inter-rater reliability, and other long-standing concerns. Results suggest that training to improve the rate of pain assessment in NICUs will enhance pain management in NICUs.Trial Registration: ClinicalTrials.gov #NCT01694745 
  •  
3.
  • Carbajal, Ricardo, et al. (författare)
  • Pain Assessment In Ventilated And Non-ventilated Neonates In Nicus Across Europe : European Pain Audit In Neonates (europain Survey)
  • 2014
  • Ingår i: Archives of Disease in Childhood. - London, United Kingdom : BMJ Publishing Group Ltd. - 0003-9888 .- 1468-2044. ; 99, s. A68-A68
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Neonates undergo many painful procedures during their NICU stay. These may include tracheal intubation/ventilation, skin-breaking procedures, drainage/suctioning of body orifices or cavities. Inherent subjectivity and difficulties of neonatal pain assessment contribute to a wide variety of assessment tools and clinical practices. To date, these practices have been not studied at a large scale.Objective: To determine current clinical practices for neonatal pain assessment in NICUs across Europe.Methods: An epidemiological observational study on bedside pain assessment practices collected data for all neonates in participating NICUs until infants left the unit (discharge, death, transfer to another hospital) or for 28 days. Data collection occurred via an online database for 1 month at each NICU. All neonates up to a gestational age of 44 weeks were included.Results: From October 2012 to June 2013, 243 NICUs from 18 European countries collected pain assessment data in 6680 neonates. Of these, 2142 received tracheal ventilation (TV), 1496 non-invasive ventilation (NIV) and 3042 only spontaneous ventilation (SV). The median (IQR) gestational age of TV, NIV and SV neonates were 32.1 (28.1–37.4), 33.6 (31.0–36.6) and 37.9 (35.0–39.9), respectively (p < 0.001). Overall, 58.5% of TV neonates, 45.0% of NIV neonates and 30.4% of SV neonates received bedside pain assessments (p < 0.001). Fig. shows pain assessments by country.Conclusions: Over half (58.5%) of TV neonates and less than half (45.0%) of NIV neonates had pain assessments performed in European NICUs. Wide variations in the rates of pain assessment exist among countries and an important improvement seems necessary.
  •  
4.
  • Carbajal, Ricardo, et al. (författare)
  • Sedation And Analgesia For Neonates In Nicus Across Europe : The Europain Survey
  • 2014
  • Ingår i: Archives of Disease in Childhood. - London, United Kingdom : BMJ Publishing Group Ltd. - 0003-9888 .- 1468-2044. ; 99, s. A64-A64
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Pain and stress induced by mechanical ventilation, invasive procedures, or painful diseases supports the use of sedation/analgesia (S/A) in newborns admitted to Neonatal Intensive Care Units (NICUs). To date, these practices have not been studied at a large scale.Objective: To determine current clinical practices regarding the use of S/A drugs in NICUs across Europe.Methods: This epidemiological observational study on bedside clinical practices regarding S/A collected data for all neonates in participating NICUs until the infant left the unit (discharge, death, transfer) or for up to 28 days. Data collection occurred via an online database for 1 month at each NICU. All neonates up to 44 weeks gestation were included.Results: From October 2012 to June 2013, 243 NICUs from 18 European countries collected data on 6680 eligible neonates. Of these, 2142 received tracheal ventilation (TV), 1496 non-invasive ventilation (NIV) and 3042 only spontaneous ventilation (SV). The median (IQR) gestational age of TV, NIV and SV neonates were 32.1 (28.1–37.4), 33.6 (31.0–36.6) and 37.9 (35.0–39.9), respectively (p < 0.001). Overall, more TV neonates [81.5% (n = 1746)] received S/A drugs than NIV neonates [17.8% (n = 266)] and SV neonates [9.3% (n = 282)]; p < 0.001. Fig. shows the rate of S/A use by country; table shows S/A drugs used.Conclusions: Most ventilated but few non-ventilated neonates (NIV and SV) receive S/A therapy in European NICUs. Wide variations in S/A use, drugs used, and mode of administration (continuous, bolus, or both) exist among countries.
  •  
5.
  • Shiraz, A., et al. (författare)
  • Compressive sensing in electrical impedance tomography for breathing monitoring
  • 2019
  • Ingår i: Physiological Measurement. - : Institute of Physics Publishing (IOPP). - 0967-3334 .- 1361-6579. ; 40:3, s. 1-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Electrical impedance tomography (EIT) is a functional imaging technique in which cross-sectional images of structures are reconstructed based on boundary trans-impedance measurements. Continuous functional thorax monitoring using EIT has been extensively researched. Increasing the number of electrodes, number of planes and frame rate may improve clinical decision making. Thus, a limiting factor in high temporal resolution, 3D and fast EIT is the handling of the volume of raw impedance data produced for transmission and its subsequent storage. Owing to the periodicity (i.e. sparsity in frequency domain) of breathing and other physiological variations that may be reflected in EIT boundary measurements, data dimensionality may be reduced efficiently at the time of sampling using compressed sensing techniques. This way, a fewer number of samples may be taken. Approach: Measurements using a 32-electrode, 48-frames-per-second EIT system from 30 neonates were post-processed to simulate random demodulation acquisition method on 2000 frames (each consisting of 544 measurements) for compression ratios (CRs) ranging from 2 to 100. Sparse reconstruction was performed by solving the basis pursuit problem using SPGL1 package. The global impedance data (i.e. sum of all 544 measurements in each frame) was used in the subsequent studies. The signal to noise ratio (SNR) for the entire frequency band (0 Hz-24 Hz) and three local frequency bands were analysed. A breath detection algorithm was applied to traces and the subsequent errorrates were calculated while considering the outcome of the algorithm applied to a down-sampled and linearly interpolated version of the traces as the baseline. Main results: SNR degradation was generally proportional with CR. The mean degradation for 0 Hz-8 Hz (of interest for the target physiological variations) was below similar to 15 dB for all CRs. The error-rates in the outcome of the breath detection algorithm in the case of decompressed traces were lower than those associated with the corresponding down-sampled traces for CR >= 25, corresponding to sub-Nyquist rate for breathing frequency. For instance, the mean error-rate associated with CR = 50 was similar to 60% lower than that of the corresponding down-sampled traces. Significance: To the best of our knowledge, no other study has evaluated the applicability of compressive sensing techniques on raw boundary impedance data in EIT. While further research should be directed at optimising the acquisition and decompression techniques for this application, this contribution serves as the baseline for future efforts.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy