SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Parsonage W.) "

Sökning: WFRF:(Parsonage W.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Neumann, J. T., et al. (författare)
  • Application of High-Sensitivity Troponin in Suspected Myocardial Infarction
  • 2019
  • Ingår i: New England Journal of Medicine. - : MASSACHUSETTS MEDICAL SOC. - 0028-4793 .- 1533-4406. ; 380:26, s. 2529-2540
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundData regarding high-sensitivity troponin concentrations in patients presenting to the emergency department with symptoms suggestive of myocardial infarction may be useful in determining the probability of myocardial infarction and subsequent 30-day outcomes. MethodsIn 15 international cohorts of patients presenting to the emergency department with symptoms suggestive of myocardial infarction, we determined the concentrations of high-sensitivity troponin I or high-sensitivity troponin T at presentation and after early or late serial sampling. The diagnostic and prognostic performance of multiple high-sensitivity troponin cutoff combinations was assessed with the use of a derivation-validation design. A risk-assessment tool that was based on these data was developed to estimate the risk of index myocardial infarction and of subsequent myocardial infarction or death at 30 days. ResultsAmong 22,651 patients (9604 in the derivation data set and 13,047 in the validation data set), the prevalence of myocardial infarction was 15.3%. Lower high-sensitivity troponin concentrations at presentation and smaller absolute changes during serial sampling were associated with a lower likelihood of myocardial infarction and a lower short-term risk of cardiovascular events. For example, high-sensitivity troponin I concentrations of less than 6 ng per liter and an absolute change of less than 4 ng per liter after 45 to 120 minutes (early serial sampling) resulted in a negative predictive value of 99.5% for myocardial infarction, with an associated 30-day risk of subsequent myocardial infarction or death of 0.2%; a total of 56.5% of the patients would be classified as being at low risk. These findings were confirmed in an external validation data set. ConclusionsA risk-assessment tool, which we developed to integrate the high-sensitivity troponin I or troponin T concentration at emergency department presentation, its dynamic change during serial sampling, and the time between the obtaining of samples, was used to estimate the probability of myocardial infarction on emergency department presentation and 30-day outcomes.
  •  
2.
  • Pickering, John W., et al. (författare)
  • Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of Detection A Collaborative Meta-analysis
  • 2017
  • Ingår i: Annals of Internal Medicine. - 0003-4819 .- 1539-3704. ; 166:10, s. 715-724
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: High-sensitivity assays for cardiac troponin T (hs-cTnT) are sometimes used to rapidly rule out acute myocardial infarction (AMI). Purpose: To estimate the ability of a single hs-cTnT concentration below the limit of detection (<0.005 mu g/L) and a nonischemic electrocardiogram (ECG) to rule out AMI in adults presenting to the emergency department (ED) with chest pain. Data Sources: EMBASE and MEDLINE without language restrictions (1 January 2008 to 14 December 2016). Study Selection: Cohort studies involving adults presenting to the ED with possible acute coronary syndrome in whom an ECG and hs-cTnT measurements were obtained and AMI outcomes adjudicated during initial hospitalization. Data Extraction: Investigators of studies provided data on the number of low-risk patients (no new ischemia on ECG and hs-cTnT measurements <0.005 mu g/L) and the number who had AMI during hospitalization (primary outcome) or a major adverse cardiac event (MACE) or death within 30 days (secondary outcomes), by risk classification (low or not low risk). Two independent epidemiologists rated risk of bias of studies. Data Synthesis: Of 9241 patients in 11 cohort studies, 2825 (30.6%) were classified as low risk. Fourteen (0.5%) low-risk patients had AMI. Sensitivity of the risk classification for AMI ranged from 87.5% to 100% in individual studies. Pooled estimated sensitivity was 98.7% (95% CI, 96.6% to 99.5%). Sensitivity for 30-day MACEs ranged from 87.9% to 100%; pooled sensitivity was 98.0% (CI, 94.7% to 99.3%). No low-risk patients died. Limitation: Few studies, variation in timing and methods of reference standard troponin tests, and heterogeneity of risk and prevalence of AMI across studies. Conclusion: A single hs-cTnT concentration below the limit of detection in combination with a nonischemic ECG may successfully rule out AMI in patients presenting to EDs with possible emergency acute coronary syndrome.
  •  
3.
  • Eggers, Kai M., 1962-, et al. (författare)
  • Diagnostic and prognostic performance of the ratio between high-sensitivity cardiac troponin I and troponin T in patients with chest pain
  • 2022
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 17:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.Methods We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99(th) percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.Results The median hs-cTn I/T ratio was 3.45 (25(th), 75(th) percentiles 1.80-6.59) in type 1 MI patients (n = 408 (sic) 46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 (sic) 6.3%]) and 0.67 (0.39-1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 (sic) 95% confidence interval 0.86-0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 (sic) 95% confidence interval 0.74-0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.Conclusions The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
  •  
4.
  • Eggers, Kai M., 1962-, et al. (författare)
  • Diagnostic and prognostic performance of the ratio between high-sensitivity cardiac troponin I and troponin T in patients with chest pain.
  • 2022
  • Ingår i: PloS one. - : Public Library of Science (PLoS). - 1932-6203. ; 17:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99th percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.The median hs-cTn I/T ratio was 3.45 (25th, 75th percentiles 1.80-6.59) in type 1 MI patients (n = 408 ☯46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 ☯6.3%]) and 0.67 (0.39-1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 ☯95% confidence interval 0.86-0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 ☯95% confidence interval 0.74-0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
  •  
5.
  • Eggers, Kai M., et al. (författare)
  • Two-hour diagnostic algorithms for early assessment of patients with acute chest pain - Implications of lowering the cardiac troponin I cut-off to the 97.5th percentile
  • 2015
  • Ingår i: Clinica Chimica Acta. - : Elsevier BV. - 0009-8981 .- 1873-3492. ; 445, s. 19-24
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Assessment of patients with suspected non-ST elevation myocardial infarction (NSTEMI) is based on cardiac troponin (cTn) levels with the 99th percentile as cut-off. However, cardiovascular risk starts already at lower troponin concentrations. We therefore, aimed to investigate the utility of 2-hour algorithms using the high-sensitivity cardiac troponin I (hs-cTnI) 97.5th percentile as cut-off which corresponds to the standard URL for most biomarkers. Methods: Hs-cTnI was measured at presentation and 2 h in 1624 chest pain patients. Diagnostic algorithms were developed applying hs-cTnI levels dichotomized at the 99th and 97.5th percentiles combined with hs-cTnI changes and/or ECG findings. Results: The prevalence of NSTEMI was 13.9%. The adjusted odds ratios for 1-year mortality were 2.7(95% CI 1.4-5.1) for the 99th percentile and 3.1 (95% CI 1.6-5.9) for the 97.5th percentile. The best-performing 99th percentile-based algorithms provided a positive predictive value (PPV) of 863% and a negative predictive value (NPV) of 993%. Using 97.5th percentile-based algorithms to define NSTEMI resulted in few reclassifications and yielded similar diagnostic estimates (PPV 85.4%, NPV 99.4%). Conclusion: The hs-cTnI 97.5th percentile integrated into 2-hour algorithms provided high diagnostic estimates and could, due to better prognostic properties serve as an alternative to the 99th percentile.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy