SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Patel Jayna J.) "

Sökning: WFRF:(Patel Jayna J.)

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Patel, Jayna J., et al. (författare)
  • Early outcomes associated with use of the Zenith TX2 Dissection Endovascular Graft for the treatment of Stanford type B aortic dissection
  • 2021
  • Ingår i: Journal of Vascular Surgery. - : Elsevier. - 0741-5214 .- 1097-6809. ; 74:2, s. 547-555
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To evaluate short term outcomes related to the use of the Zenith TX2 Dissection Endovascular Graft (ZDEG) and the Zenith Dissection Bare stent (ZDES) for the treatment of Stanford type B aortic dissections. Methods: This retrospective multicenter case cohort study collated data from 10 European institutions for patients with both complicated and uncomplicated type B aortic dissection treated with ZDEG and ZDES between 2011 and 2018. The primary end point was mortality at 30 and 90 days. Secondary end points included complications related to TEVAR, such as, type Ia endoleak, stroke, paraparesis, paraplegia, and retrograde type A dissection (RTAD). Statistical analysis was carried out using the t test, or one-way analysis of variance and the chi(2) or Fisher exact tests. Results: We treated 120 patients (87 male; mean age, 62.7 +/- 12.2years) either in the acute 76 (63.3%), subacute 16 (13.3%), or chronic 28 (23.3%) phase. Seven patients (5.8%) died within 30 days after the index procedure and two (1.7%) between 30 and 90 days. There was one instance of postoperative RTAD in a patient treated for rupture. Stroke and paraplegia occurred in three (2.5%) and five (4.2%), patients, respectively. Eight patients (6.7%) had a type Ia endoleak in the perioperative period. There were no instances of paraplegia, no permanent dialysis, and no requirement for adjunctive superior mesenteric or celiac artery stenting in the 33 patients (27.5%) who were treated by concurrent placement of ZDES distal to the ZDEG. The length and distal oversizing of ZDEG components used was less in this group. Conclusions: The present series demonstrates a low (<1%) RTAD rate and favorable morbidity and mortality. The lower rate of paraplegia, dialysis, and visceral artery stenting in the cohort that had adjunctive use of ZDES is compelling and merits further assessment.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy