1.
  • Pausch, G., et al. (författare)
  • RoSiB - a 4 pi silicon ball for charged-particle detection in EUROBALL
  • 2000
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 443:03-feb, s. 304-318
  • Tidskriftsartikel (refereegranskat)abstract
    • A 4 pi silicon bail for detection and identification of light charged particles in large multidetector gamma-arrays as EUROBALL is presented. The design is based on a N = 42 ball with 12 pentagons and 30 hexagons as used in the GASP array. The absorptive material for gamma-rays is minimized to the detector thickness of 300 or 500 mu m and a 0.63 mm ceramic backing. The geometrical coverage is designed for about 90% of 4 pi. A pulse shape discrimination method with totally depleted detectors working in the reverse mount allows identifying protons and alpha-particles above an energy threshold of about 2 MeV. The performances of the ball were rested at the tandem - booster accelerator combination of the MPI Heidelberg in two experiments using the high-recoil reaction of 228 MeV Ni-58 + Ti-46 and the low-recoil reaction of 95 MeV O-16 + Ni-58. The two-dimensional spectra of zero-crossing (ZC) versus energy confirmed an excellent discrimination of protons and alpha-particles in all the detectors at different angles. The energy spectra of protons and alpha-particles measured in the experiments are presented. too. The gamma-spectra measured in coincidence with various combinations of emitted particles showed a high selectivity of the ball. The reduced total efficiency for protons of 59% and 55% and alpha-particles of 44% and 32% measured in a nuclear spectroscopy application is analyzed in a Monte-Carlo simulation (GEANT). It is due to a combined influence of a thick target needed to stop the recoiling residual nuclei and thick absorbers needed to protect the Si-detectors from scattered beam. The results along with the GEANT extrapolation to optimum experimental conditions confirm that RoSiB is a highly efficient and selective device for identification of rare reaction channels with heavy ions.
  •  
2.
  • Güsten, R., et al. (författare)
  • APEX - The Atacama Pathfinder Experiment
  • 2006
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 0277-786X .- 1996-756X. ; 6267 I
  • Konferensbidrag (refereegranskat)abstract
    • APEX, the Atacama Pathfinder Experiment, has been successfully commissioned and is in operation now. This novel submillimeter telescope is located at 5107 m altitude on Llano de Chajnantor in the Chilean High Andes, on what is considered one of the world's outstanding sites for submillimeter astronomy. The primary reflector with 12 m diameter has been carefully adjusted by means of holography. Its surface smoothness of 17-18 μm makes APEX suitable for observations up to 200 μm, through all atmospheric submm windows accessible from the ground.
  •  
3.
  • Pausch, G, et al. (författare)
  • RoSiB - a 4 pi silicon ball for charged-particle detection in EUROBALL
  • 2000
  • Ingår i: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. - : ELSEVIER SCIENCE BV, AMSTERDAM. - 0168-9002. ; 443:2-3, s. 304-318
  • Tidskriftsartikel (refereegranskat)abstract
    • A 4 pi silicon bail for detection and identification of light charged particles in large multidetector gamma-arrays as EUROBALL is presented. The design is based on a N = 42 ball with 12 pentagons and 30 hexagons as used in the GASP array. The absorptive
  •  
4.
  • Swiderski, L., et al. (författare)
  • Boron-10 loaded BC523A liquid scintillator for neutron detection in the border monitoring
  • 2007
  • Ingår i: 2007 IEEE Nuclear Science Symposium & Medical Imaging Conference. - : IEEE. - 1424409233 - 9781424409235 ; , s. 1389-1395
  • Konferensbidrag (refereegranskat)abstract
    • A BC523A liquid scintillator loaded with boron-10 was tested as a detector for both fast and thermal neutrons. Pulse shape discrimination (PSD) method based on a zero-crossing principle was applied to distinguish between neutron and gamma radiation. High quantum efficiency Photonis XP5500B photomultiplier was used to enhance light detection from the scintillator. This allowed a good registration of the energy spectrum of neutron capture events on boron-10, corresponding to about 60 keVee. The applied PSD method proved to be useful for n/γ discrimination. A good resolving power of the method was achieved even without gating on neutron capture events. A comparison with a standard BC501A liquid scintillator was done to evaluate thermal neutrons detection efficiency in BC523A.
  •  
5.
  • Swiderski, L., et al. (författare)
  • Boron-10 Loaded BC523A Liquid Scintillator for Neutron Detection in the Border Monitoring
  • 2008
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 55:6, s. 3710-3716
  • Tidskriftsartikel (refereegranskat)abstract
    • A BC523A liquid scintillator loaded with boron-10 was tested as a detector for both fast and thermal neutrons. A pulse shape discrimination (PSD) method based on a zero-crossing principle was applied to distinguish between neutron and gamma radiation. High quantum efficiency Photonis XP5500B photomultiplier was used to enhance light detection from the scintillator. This allowed a good registration of the energy spectrum of neutron capture events on boron-10, corresponding to about 60 keV gamma-rays. The applied PSD method proved to be useful for n/gamma discrimination. A good resolving power of the method was achieved even without gating on neutron capture events. A comparison with a standard BC501A liquid scintillator was done to evaluate thermal neutrons detection efficiency in BC523A.
  •  
6.
  • Swiderski, L., et al. (författare)
  • Further Study of Boron-10 Loaded Liquid Scintillators for Detection of Fast and Thermal Neutrons
  • 2010
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 57:1, s. 375-380
  • Tidskriftsartikel (refereegranskat)abstract
    • Boron-10 loaded liquid scintillators were studied in order to improve n/gamma separation. Pulse shape discrimination (PSD) was implemented by means of a zero-crossing (ZC) method to distinguish between gamma-rays and fast/slow neutrons. Significant progress was done for BC523A2 and EJ339A2 scintillators loaded with reduced amount of B-10 (2% and 2.5%, respectively), as compared to the results obtained earlier with BC523A loaded with 4.4% of B-10. The improvement was probably caused by the reduction of B-10 content, as indicated in the reported study. A B-10 loaded scintillator EJ309B5 based on non- flammable liquid was also studied, showing the best separation of thermal neutron capture events from fast neutrons, gamma-rays and noise.
  •  
7.
  • Swiderski, L., et al. (författare)
  • Further study of Boron-10 loaded liquid scintillators for detection of fast and thermal neutrons
  • 2008
  • Konferensbidrag (refereegranskat)abstract
    • Boron-10 loaded liquid scintillators were studied in order to improve n/γ separation. Pulse shape discrimination (PSD) was done by means of a zero-crossing (ZC) method to distinguish between γ-rays and fast/slow neutrons. A significant progress was achieved for BC523A2 and EJ339A2 loaded with reduced amount of ,10B (2% and 2.5%, respectively), as compared to the results obtained earlier with BC523A loaded with 5% of 10B. The improvement was probably caused by the reduction of 10B content, as indicated in the latter study. A 10B loaded scintillator EJ309B5 based on a non-flammable liquid was also studied, showing the best separation of thermal neutron capture events from fast neutrons, γ-rays and noise.
  •  