SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Pemberton Christopher) "

Search: WFRF:(Pemberton Christopher)

  • Result 1-6 of 6
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Pickering, John W., et al. (author)
  • Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of Detection A Collaborative Meta-analysis
  • 2017
  • In: Annals of Internal Medicine. - 0003-4819 .- 1539-3704. ; 166:10, s. 715-724
  • Journal article (peer-reviewed)abstract
    • Background: High-sensitivity assays for cardiac troponin T (hs-cTnT) are sometimes used to rapidly rule out acute myocardial infarction (AMI). Purpose: To estimate the ability of a single hs-cTnT concentration below the limit of detection (<0.005 mu g/L) and a nonischemic electrocardiogram (ECG) to rule out AMI in adults presenting to the emergency department (ED) with chest pain. Data Sources: EMBASE and MEDLINE without language restrictions (1 January 2008 to 14 December 2016). Study Selection: Cohort studies involving adults presenting to the ED with possible acute coronary syndrome in whom an ECG and hs-cTnT measurements were obtained and AMI outcomes adjudicated during initial hospitalization. Data Extraction: Investigators of studies provided data on the number of low-risk patients (no new ischemia on ECG and hs-cTnT measurements <0.005 mu g/L) and the number who had AMI during hospitalization (primary outcome) or a major adverse cardiac event (MACE) or death within 30 days (secondary outcomes), by risk classification (low or not low risk). Two independent epidemiologists rated risk of bias of studies. Data Synthesis: Of 9241 patients in 11 cohort studies, 2825 (30.6%) were classified as low risk. Fourteen (0.5%) low-risk patients had AMI. Sensitivity of the risk classification for AMI ranged from 87.5% to 100% in individual studies. Pooled estimated sensitivity was 98.7% (95% CI, 96.6% to 99.5%). Sensitivity for 30-day MACEs ranged from 87.9% to 100%; pooled sensitivity was 98.0% (CI, 94.7% to 99.3%). No low-risk patients died. Limitation: Few studies, variation in timing and methods of reference standard troponin tests, and heterogeneity of risk and prevalence of AMI across studies. Conclusion: A single hs-cTnT concentration below the limit of detection in combination with a nonischemic ECG may successfully rule out AMI in patients presenting to EDs with possible emergency acute coronary syndrome.
  •  
2.
  • Eggers, Kai M., 1962-, et al. (author)
  • Diagnostic and prognostic performance of the ratio between high-sensitivity cardiac troponin I and troponin T in patients with chest pain
  • 2022
  • In: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 17:11
  • Journal article (peer-reviewed)abstract
    • Background Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.Methods We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99(th) percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.Results The median hs-cTn I/T ratio was 3.45 (25(th), 75(th) percentiles 1.80-6.59) in type 1 MI patients (n = 408 (sic) 46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 (sic) 6.3%]) and 0.67 (0.39-1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 (sic) 95% confidence interval 0.86-0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 (sic) 95% confidence interval 0.74-0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.Conclusions The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
  •  
3.
  • Eggers, Kai M., 1962-, et al. (author)
  • Diagnostic and prognostic performance of the ratio between high-sensitivity cardiac troponin I and troponin T in patients with chest pain.
  • 2022
  • In: PloS one. - : Public Library of Science (PLoS). - 1932-6203. ; 17:11
  • Journal article (peer-reviewed)abstract
    • Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99th percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.The median hs-cTn I/T ratio was 3.45 (25th, 75th percentiles 1.80-6.59) in type 1 MI patients (n = 408 ☯46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 ☯6.3%]) and 0.67 (0.39-1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 ☯95% confidence interval 0.86-0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 ☯95% confidence interval 0.74-0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
  •  
4.
  • Neumann, Johannes Tobias, et al. (author)
  • Personalized diagnosis in suspected myocardial infarction
  • 2023
  • In: Clinical Research in Cardiology. - : Springer. - 1861-0684 .- 1861-0692. ; 112, s. 1288-1301
  • Journal article (peer-reviewed)abstract
    • Background: In suspected myocardial infarction (MI), guidelines recommend using high-sensitivity cardiac troponin (hscTn)- based approaches. These require fixed assay-specific thresholds and timepoints, without directly integrating clinical information. Using machine-learning techniques including hs-cTn and clinical routine variables, we aimed to build a digital tool to directly estimate the individual probability of MI, allowing for numerous hs-cTn assays.Methods: In 2,575 patients presenting to the emergency department with suspected MI, two ensembles of machine-learning models using single or serial concentrations of six different hs-cTn assays were derived to estimate the individual MI probability ( ARTEMIS model). Discriminative performance of the models was assessed using area under the receiver operating characteristic curve (AUC) and logLoss. Model performance was validated in an external cohort with 1688 patients and tested for global generalizability in 13 international cohorts with 23,411 patients.Results: Eleven routinely available variables including age, sex, cardiovascular risk factors, electrocardiography, and hs-cTn were included in the ARTEMIS models. In the validation and generalization cohorts, excellent discriminative performance was confirmed, superior to hs-cTn only. For the serial hs-cTn measurement model, AUC ranged from 0.92 to 0.98. Good calibration was observed. Using a single hs-cTn measurement, the ARTEMIS model allowed direct rule-out of MI with very high and similar safety but up to tripled efficiency compared to the guideline- recommended strategy.Conclusion We developed and validated diagnostic models to accurately estimate the individual probability of MI, which allow for variable hs-cTn use and flexible timing of resampling. Their digital application may provide rapid, safe and efficient personalized patient care.
  •  
5.
  • Pemberton, Hugh G., et al. (author)
  • Quantification of amyloid PET for future clinical use : a state-of-the-art review
  • 2022
  • In: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 49:10, s. 3508-3528
  • Research review (peer-reviewed)abstract
    • Amyloid-β (Aβ) pathology is one of the earliest detectable brain changes in Alzheimer’s disease (AD) pathogenesis. The overall load and spatial distribution of brain Aβ can be determined in vivo using positron emission tomography (PET), for which three fluorine-18 labelled radiotracers have been approved for clinical use. In clinical practice, trained readers will categorise scans as either Aβ positive or negative, based on visual inspection. Diagnostic decisions are often based on these reads and patient selection for clinical trials is increasingly guided by amyloid status. However, tracer deposition in the grey matter as a function of amyloid load is an inherently continuous process, which is not sufficiently appreciated through binary cut-offs alone. State-of-the-art methods for amyloid PET quantification can generate tracer-independent measures of Aβ burden. Recent research has shown the ability of these quantitative measures to highlight pathological changes at the earliest stages of the AD continuum and generate more sensitive thresholds, as well as improving diagnostic confidence around established binary cut-offs. With the recent FDA approval of aducanumab and more candidate drugs on the horizon, early identification of amyloid burden using quantitative measures is critical for enrolling appropriate subjects to help establish the optimal window for therapeutic intervention and secondary prevention. In addition, quantitative amyloid measurements are used for treatment response monitoring in clinical trials. In clinical settings, large multi-centre studies have shown that amyloid PET results change both diagnosis and patient management and that quantification can accurately predict rates of cognitive decline. Whether these changes in management reflect an improvement in clinical outcomes is yet to be determined and further validation work is required to establish the utility of quantification for supporting treatment endpoint decisions. In this state-of-the-art review, several tools and measures available for amyloid PET quantification are summarised and discussed. Use of these methods is growing both clinically and in the research domain. Concurrently, there is a duty of care to the wider dementia community to increase visibility and understanding of these methods.
  •  
6.
  • Pemberton, Hugh G., et al. (author)
  • Software compatibility analysis for quantitative measures of [18F]flutemetamol amyloid PET burden in mild cognitive impairment
  • 2023
  • In: EJNMMI Research. - 2191-219X. ; 13:1
  • Journal article (peer-reviewed)abstract
    • Rationale: Amyloid-β (Aβ) pathology is one of the earliest detectable brain changes in Alzheimer’s disease pathogenesis. In clinical practice, trained readers will visually categorise positron emission tomography (PET) scans as either Aβ positive or negative. However, adjunct quantitative analysis is becoming more widely available, where regulatory approved software can currently generate metrics such as standardised uptake value ratios (SUVr) and individual Z-scores. Therefore, it is of direct value to the imaging community to assess the compatibility of commercially available software packages. In this collaborative project, the compatibility of amyloid PET quantification was investigated across four regulatory approved software packages. In doing so, the intention is to increase visibility and understanding of clinically relevant quantitative methods. Methods: Composite SUVr using the pons as the reference region was generated from [18F]flutemetamol (GE Healthcare) PET in a retrospective cohort of 80 amnestic mild cognitive impairment (aMCI) patients (40 each male/female; mean age = 73 years, SD = 8.52). Based on previous autopsy validation work, an Aβ positivity threshold of ≥ 0.6 SUVrpons was applied. Quantitative results from MIM Software’s MIMneuro, Syntermed’s NeuroQ, Hermes Medical Solutions’ BRASS and GE Healthcare’s CortexID were analysed using intraclass correlation coefficient (ICC), percentage agreement around the Aβ positivity threshold and kappa scores. Results: Using an Aβ positivity threshold of ≥ 0.6 SUVrpons, 95% agreement was achieved across the four software packages. Two patients were narrowly classed as Aβ negative by one software package but positive by the others, and two patients vice versa. All kappa scores around the same Aβ positivity threshold, both combined (Fleiss’) and individual software pairings (Cohen’s), were ≥ 0.9 signifying “almost perfect” inter-rater reliability. Excellent reliability was found between composite SUVr measurements for all four software packages, with an average measure ICC of 0.97 and 95% confidence interval of 0.957–0.979. Correlation coefficient analysis between the two software packages reporting composite z-scores was strong (r 2 = 0.98). Conclusion: Using an optimised cortical mask, regulatory approved software packages provided highly correlated and reliable quantification of [18F]flutemetamol amyloid PET with a ≥ 0.6 SUVrpons positivity threshold. In particular, this work could be of interest to physicians performing routine clinical imaging rather than researchers performing more bespoke image analysis. Similar analysis is encouraged using other reference regions as well as the Centiloid scale, when it has been implemented by more software packages.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-6 of 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view