SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Poder A) "

Sökning: WFRF:(Poder A)

  • Resultat 1-12 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Walker, Anthony P, et al. (författare)
  • Horizon 2020 EuPRAXIA design study
  • 2017
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 874:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The Horizon 2020 Project EuPRAXIA ("European Plasma Research Accelerator with eXcellence In Applications") is preparing a conceptual design report of a highly compact and cost-effective European facility with multi-GeV electron beams using plasma as the acceleration medium. The accelerator facility will be based on a laser and/or a beam driven plasma acceleration approach and will be used for photon science, high-energy physics (HEP) detector tests, and other applications such as compact X-ray sources for medical imaging or material processing. EuPRAXIA started in November 2015 and will deliver the design report in October 2019. EuPRAXIA aims to be included on the ESFRI roadmap in 2020.
  •  
2.
  • Abu-Elyazeed, R R, et al. (författare)
  • Safety and immunogenicity of a glycoprotein D genital herpes vaccine in healthy girls 10-17 years of age : results from a randomised, controlled, double-blind trial
  • 2013
  • Ingår i: Vaccine. - : Elsevier BV. - 0264-410X .- 1873-2518. ; 31:51, s. 6136-6143
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The investigational AS04-adjuvanted herpes simplex virus type 2 (HSV-2) glycoprotein D (gD2) subunit prophylactic vaccine ('HSV vaccine'; GlaxoSmithKline Vaccines) has been shown to be well tolerated in adults, but limited data exist for pre-teen and adolescent girls, a likely target population. The primary objective of this study was to compare the occurrence of serious adverse events (SAEs) over 12 months between HSV vaccine recipients and saline recipients (placebo control group) in pre-teen and adolescent girls. The immunogenicity of the HSV vaccine was also assessed.METHODS: Healthy girls aged 10-17 years, stratified by age (10-15 years; 16-17 years), were randomised 2:1:1 to receive the HSV vaccine, a hepatitis A vaccine (Havrix™; HAV control) or placebo (saline) according to a 0-, 1-, 6-month schedule. Participants and study personnel not involved in the preparation or administration of vaccines were blinded to treatment. Safety and immunogenicity analyses were performed overall and by age (10-15 years; 16-17 years) and HSV serostatus.RESULTS: No statistically significant difference in the percentage of subjects with SAEs was observed between the HSV and saline group, or between the HSV and pooled control (HAV and saline) groups. The HSV vaccine was well tolerated, although a higher incidence of solicited local symptoms was observed in the HSV group than in the control group. Neither age nor HSV serostatus at the time of study entry had an impact on the safety profile of this vaccine. The HSV vaccine was immunogenic regardless of pre-vaccination HSV serostatus. Higher anti-gD geometric mean concentrations were observed in HSV-1 seropositive participants than in HSV-1 seronegative participants.CONCLUSION: The HSV vaccine had an acceptable safety profile, and was well tolerated and immunogenic when administered to girls aged 10-17 years regardless of age or HSV pre-vaccination serostatus.
  •  
3.
  • Sarri, Gianluca, et al. (författare)
  • Laser-driven generation of collimated ultra-relativistic positron beams
  • 2013
  • Ingår i: Plasma Physics and Controlled Fusion. - London : Institute of Physics (IOP). - 0741-3335 .- 1361-6587. ; 55:12
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on recent experimental results concerning the generation of collimated (divergence of the order of a few mrad) ultra-relativistic positron beams using a fully optical system. The positron beams are generated exploiting a quantum-electrodynamic cascade initiated by the propagation of a laser-accelerated, ultra-relativistic electron beam through high-Z solid targets. As long as the target thickness is comparable to or smaller than the radiation length of the material, the divergence of the escaping positron beam is of the order of the inverse of its Lorentz factor. For thicker solid targets the divergence is seen to gradually increase, due to the increased number of fundamental steps in the cascade, but it is still kept of the order of few tens of mrad, depending on the spectral components in the beam. This high degree of collimation will be fundamental for further injection into plasma-wakefield afterburners.
  •  
4.
  •  
5.
  • Behm, K. T., et al. (författare)
  • A spectrometer for ultrashort gamma-ray pulses with photon energies greater than 10 MeV
  • 2018
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 1089-7623 .- 0034-6748. ; 89:11
  • Tidskriftsartikel (refereegranskat)abstract
    • © 2018 Author(s). We present a design for a pixelated scintillator based gamma-ray spectrometer for non-linear inverse Compton scattering experiments. By colliding a laser wakefield accelerated electron beam with a tightly focused, intense laser pulse, gamma-ray photons up to 100 MeV energies and with few femtosecond duration may be produced. To measure the energy spectrum and angular distribution, a 33 × 47 array of cesium-iodide crystals was oriented such that the 47 crystal length axis was parallel to the gamma-ray beam and the 33 crystal length axis was oriented in the vertical direction. Using an iterative deconvolution method similar to the YOGI code, modeling of the scintillator response using GEANT4 and fitting to a quantum Monte Carlo calculated photon spectrum, we are able to extract the gamma ray spectra generated by the inverse Compton interaction.
  •  
6.
  • Cole, J. M., et al. (författare)
  • Experimental Evidence of Radiation Reaction in the Collision of a High-Intensity Laser Pulse with a Laser-Wakefield Accelerated Electron Beam
  • 2018
  • Ingår i: Physical Review X. - 2160-3308. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The dynamics of energetic particles in strong electromagnetic fields can be heavily influenced by the energy loss arising from the emission of radiation during acceleration, known as radiation reaction. When interacting with a high-energy electron beam, today's lasers are sufficiently intense to explore the transition between the classical and quantum radiation reaction regimes. We present evidence of radiation reaction in the collision of an ultrarelativistic electron beam generated by laser-wakefield acceleration (μ 500 MeV) with an intense laser pulse (a0 > 10). We measure an energy loss in the postcollision electron spectrum that is correlated with the detected signal of hard photons (γ rays), consistent with a quantum description of radiation reaction. The generated γ rays have the highest energies yet reported from an all-optical inverse Compton scattering scheme, with critical energy > 30 MeV.
  •  
7.
  • López-Fauqued, M., et al. (författare)
  • Safety profile of the adjuvanted recombinant zoster vaccine : Pooled analysis of two large randomised phase 3 trials
  • 2019
  • Ingår i: Vaccine. - : Elsevier Ltd. - 0264-410X .- 1873-2518. ; 37:18, s. 2482-2493
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The ZOE-50 (NCT01165177) and ZOE-70 (NCT01165229) phase 3 clinical trials showed that the adjuvanted recombinant zoster vaccine (RZV) was ≥90% efficacious in preventing herpes zoster in adults. Here we present a comprehensive overview of the safety data from these studies. Methods: Adults aged ≥50 (ZOE-50) and ≥70 (ZOE-70) years were randomly vaccinated with RZV or placebo. Safety analyses were performed on the pooled total vaccinated cohort, consisting of participants receiving at least one dose of RZV or placebo. Solicited and unsolicited adverse events (AEs) were collected for 7 and 30 days after each vaccination, respectively. Serious AEs (SAEs) were collected from the first vaccination until 12 months post-last dose. Fatal AEs, vaccination-related SAEs, and potential immune-mediated diseases (pIMDs) were collected during the entire study period. Results: Safety was evaluated in 14,645 RZV and 14,660 placebo recipients. More RZV than placebo recipients reported unsolicited AEs (50.5% versus 32.0%); the difference was driven by transient injection site and solicited systemic reactions that were generally seen in the first week post-vaccination. The occurrence of overall SAEs (RZV: 10.1%; Placebo: 10.4%), fatal AEs (RZV: 4.3%; Placebo: 4.6%), and pIMDs (RZV: 1.2%; Placebo: 1.4%) was balanced between groups. The occurrence of possible exacerbations of pIMDs was rare and similar between groups. Overall, except for the expected local and systemic symptoms, the safety results were comparable between the RZV and Placebo groups irrespective of participant age, gender, or race. Conclusions: No safety concerns arose, supporting the favorable benefit-risk profile of RZV. © 2019 GlaxoSmithKline Biologicals SA
  •  
8.
  • Papp, Zoltan, et al. (författare)
  • Levosimendan Efficacy and Safety : 20 Years of SIMDAX in Clinical Use
  • 2020
  • Ingår i: Journal of Cardiovascular Pharmacology. - : Ovid Technologies (Wolters Kluwer Health). - 0160-2446 .- 1533-4023. ; 76:1, s. 4-22
  • Tidskriftsartikel (refereegranskat)abstract
    • Levosimendan was first approved for clinical use in 2000, when authorization was granted by Swedish regulatory authorities for the hemodynamic stabilization of patients with acutely decompensated chronic heart failure (HF). In the ensuing 20 years, this distinctive inodilator, which enhances cardiac contractility through calcium sensitization and promotes vasodilatation through the opening of adenosine triphosphate-dependent potassium channels on vascular smooth muscle cells, has been approved in more than 60 jurisdictions, including most of the countries of the European Union and Latin America. Areas of clinical application have expanded considerably and now include cardiogenic shock, takotsubo cardiomyopathy, advanced HF, right ventricular failure, pulmonary hypertension, cardiac surgery, critical care, and emergency medicine. Levosimendan is currently in active clinical evaluation in the United States. Levosimendan in IV formulation is being used as a research tool in the exploration of a wide range of cardiac and noncardiac disease states. A levosimendan oral form is at present under evaluation in the management of amyotrophic lateral sclerosis. To mark the 20 years since the advent of levosimendan in clinical use, 51 experts from 23 European countries (Austria, Belgium, Croatia, Cyprus, Czech Republic, Estonia, Finland, France, Germany, Greece, Hungary, Italy, the Netherlands, Norway, Poland, Portugal, Russia, Slovenia, Spain, Sweden, Switzerland, the United Kingdom, and Ukraine) contributed to this essay, which evaluates one of the relatively few drugs to have been successfully introduced into the acute HF arena in recent times and charts a possible development trajectory for the next 20 years.
  •  
9.
  • Poder, J., et al. (författare)
  • Risk and Quality in Brachytherapy From a Technical Perspective
  • 2023
  • Ingår i: Clinical Oncology. - : ELSEVIER SCIENCE LONDON. - 0936-6555 .- 1433-2981. ; 35:8, s. 541-547
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: To provide an overview of the history of incidents in brachytherapy and to describe the pillars in place to ensure that medical physicists deliver high quality brachytherapy. Materials and methods: A review of the literature was carried out to identify reported incidents in brachytherapy, together with an evaluation of the structures and processes in place to ensure that medical physicists deliver high-quality brachytherapy. In particular, the role of education and training, the use of process and technical quality assurance and the role of international guidelines are discussed. Results: There are many human factors in brachytherapy procedures that introduce additional risks into the process. Most of the reported incidents in the literature are related to human factors. Brachytherapy-related education and training initiatives are in place at the societal and departmental level for medical physicists. Additionally, medical physicists have developed process and technical quality assurance procedures, together with international guidelines and protocols. Education and training initiatives, together with quality assurance procedures and international guidelines may reduce the risk of human factors in brachytherapy. Conclusion: Through application of the three pillars (education and training; process control and technical quality assurance; international guidelines), medical physicists will continue to minimise risk and deliver high-quality brachytherapy treatments. & COPY; 2023 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
  •  
10.
  • Warwick, J., et al. (författare)
  • Experimental Observation of a Current-Driven Instability in a Neutral Electron-Positron Beam
  • 2017
  • Ingår i: Physical Review Letters. - : AMER PHYSICAL SOC. - 0031-9007 .- 1079-7114. ; 119:18
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the first experimental observation of a current-driven instability developing in a quasineutral matter-antimatter beam. Strong magnetic fields (amp;gt;= 1 T) are measured, via means of a proton radiography technique, after the propagation of a neutral electron-positron beam through a background electron-ion plasma. The experimentally determined equipartition parameter of epsilon(B) approximate to 10(-3) is typical of values inferred from models of astrophysical gamma-ray bursts, in which the relativistic flows are also expected to be pair dominated. The data, supported by particle-in-cell simulations and simple analytical estimates, indicate that these magnetic fields persist in the background plasma for thousands of inverse plasma frequencies. The existence of such long-lived magnetic fields can be related to analog astrophysical systems, such as those prevalent in lepton-dominated jets.
  •  
11.
  •  
12.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-12 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy