1.
  • Ekqvist, Susanne, et al. (författare)
  • High frequency of contact allergy to gold in patients with endovascular coronary stents
  • 2007
  • Ingår i: British Journal of Dermatology. - : Oxford University Press (OUP). - 1365-2133 .- 0007-0963. ; 157:4, s. 730-738
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Stent implantation is an effective method for treatment of atherosclerotic disease. Factors predisposing to in-stent restenosis are still largely unknown. Contact allergy to metal ions eluted from the stent has been suggested to be a risk factor. Objectives To explore whether there is a possible induction of contact allergy to metals used in stents among patients with a stainless steel stent containing nickel (Ni stent) and patients with a gold-plated stent (Au stent). Methods Adults (n = 484) treated with coronary stent implantation participated in the study with patch testing. The study design was retrospective and cross-sectional with no assessment of contact allergy before stenting. Age- and sex-matched patch-tested patients with dermatitis (n = 447) served as controls. Results Of Au-stented patients, 54 of 146 (37%) were allergic to gold compared with 85 of 447 (19%) controls (P < 0.001). Within the stented population there were no statistically significant differences in contact allergy to gold or nickel between Ni-stented and Au-stented patients. In multivariate models where other risk factors for contact allergy to gold were considered, the Au stent showed a trend towards statistical significance (odds ratio 1.43, 95% confidence interval 0.95-2.16; P = 0.09). Conclusions As the frequency of contact allergy to gold is higher in stented patients independent of stent type it suggests a previous sensitization. However, several pieces of circumstantial evidence as well as statistical analysis indicate the possibility of sensitization in the coronary vessel by the Au stent. Ni stents and Au stents should not be ruled out as risk factors for induction of contact allergy to these metals.
  •  
2.
  • Yuan, S, et al. (författare)
  • Dispersion of repolarization following double and triple programmed stimulation. A clinical study using the monophasic action potential recording technique
  • 1996
  • Ingår i: European Heart Journal. - 0195-668X. ; 17, s. 1080-
  • Tidskriftsartikel (refereegranskat)abstract
    • To study the dispersion of ventricular repolarization following double and triple programmed stimulation and its correlation with the inducibility of ventricular arrhythmias, monophasic action potentials were simultaneously recorded from the right ventricular apex and outflow tract during programmed stimulation in 12 patients with ventricular arrhythmias and a normal QT interval. The time difference between the ends of the two monophasic action potentials were used as a measure of the dispersion of ventricular repolarization, which consists of the activation time difference and the monophasic action potential duration difference. During double and triple programmed stimulation, the dispersion of ventricular repolarization increased significantly with the shortening of the coupling interval but decreased slightly with the shortening of the preceding interval. The induction of the ventricular arrhythmias in these patients was invariably associated with a marked increase in the dispersion of ventricular repolarization. The maximal dispersion of ventricular repolarization was significantly larger in the seven patients with polymorphic ventricular tachycardia and/or ventricular flutter/fibrillation induced than in the four patients with monomorphic ventricular tachycardia induced. Analysis of the two components of the dispersion of ventricular repolarization revealed that the increased dispersion of ventricular repolarization was mainly caused by an increase in the activation time difference in the monomorphic ventricular tachycardia subgroup, and by increases in both the activation time difference and monophasic action potential duration difference in the polymorphic ventricular tachycardia/fibrillation subgroup. These findings suggest that increased dispersion of ventricular repolarization is one of the underlying mechanisms accounting for the myocardial vulnerability to ventricular arrhythmias and that repolarization disturbance is important for the genesis of polymorphic ventricular tachycardia/fibrillation.
  •  
3.
  • Yuan, Shiwen, et al. (författare)
  • Recording monophasic action potentials using a platinum-electrode ablation catheter
  • 2000
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1532-2092 .- 1099-5129. ; 2:4, s. 312-319
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The monophasic action potential (MAP) is conventionally recorded using Ag-AgCl electrodes which are not suitable for delivering radiofrequency currents. To be able to use the sharp MAP upstroke for identifying the local activation, as a step towards the development of a MAP-guided catheter ablation technique, the possibility of recording MAP via platinum electrodes of an ordinary ablation catheter was explored. METHODS AND RESULTS: One hundred and forty-two MAP recordings from the endocardium were obtained via an ablation catheter in 40 patients undergoing electrophysiological study/catheter ablation. During sinus rhythm and pacing, 90% of the ventricular and 100% of the atrial MAPs had stable baselines. The amplitudes were 13 +/- 4.2 mV for ventricular and 2.4 +/- 0.8 mV for atrial MAPs. During mapping and ablation, MAPs and uni- and bipolar electrograms were recorded simultaneously using the same tip electrode in eight patients. The MAPs provided more distinct local activation than the electrograms. During 17 MAP recordings, additional MAPs were recorded simultaneously using an Ag-AgCl electrode catheter in the immediate vicinity of the ablation catheter. The MAPs taken with the ablation catheter had characteristics consistent with those taken with the Ag-AgCl catheter. CONCLUSIONS: (1) Platinum electrodes can be used for timely recording of MAPs in patients. (2) It is feasible to record MAPs and deliver radiofrequency currents via the same platinum-tip electrode. These findings suggest that MAP-guided catheter ablation is technically possible.
  •  
4.
  • Yuan, S, et al. (författare)
  • Signed value of monophasic action potential duration difference. A useful measure in evaluation of dispersion of repolarization in patients with ventricular arrhythmias
  • 1997
  • Ingår i: European Heart Journal. - 0195-668X. ; 18:8, s. 38-1329
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: To evaluate the usefulness of the signed value of monophasic action potential duration difference in analysing the cause of dispersion of ventricular repolarization.METHODS AND RESULTS: Monophasic action potentials were simultaneously recorded from the right ventricular apex and outflow tract during programmed stimulation in 36 patients with ventricular arrhythmias. The time difference between the ends of repolarization on the two monophasic action potentials was used as a measure of the dispersion of ventricular repolarization, and the signed value of the monophasic action potential duration difference was used to specify the contributions of the activation time difference and the monophasic action potential duration difference to the dispersion of ventricular repolarization. During right ventricular pacing, single and double programmed stimulation and at the induction of ventricular arrhythmias, the dispersion of ventricular repolarization and the signed value of monophasic action potential duration difference were markedly greater in the 11 patients with polymorphic ventricular tachycardia/ventricular fibrillation induced than in the 13 patients with monomorphic ventricular tachycardia induced, and in the 10 patients with clinical polymorphic ventricular tachycardia/ventricular fibrillation/cardiac arrest than in the 12 patients with sustained monomorphic ventricular tachycardia. This disclosed that the increased dispersion of ventricular repolarization was caused by increases in both the activation time difference and the monophasic action potential duration difference in the former, but mainly by an increased activation time difference in the latter groups.CONCLUSION: The signed value of monophasic action potential duration difference can specify whether an increased dispersion of ventricular repolarization is caused by inhomogeneous repolarization, inhomogeneous conduction or both, and thereby it is useful in study of the mechanism of ventricular arrhythmias.
  •  