SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Rens W.) "

Search: WFRF:(Rens W.)

  • Result 1-9 of 9
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Aguilar, J A, et al. (author)
  • Transmission of light in deep sea water at the site of the ANTARES neutrino telescope
  • 2005
  • In: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 23:1, s. 131-155
  • Journal article (peer-reviewed)abstract
    • The ANTARES neutrino telescope is a large photomultiplier array designed to detect neutrino-induced upward-going muons by their Cherenkov radiation. Understanding the absorption and scattering of light in the deep Mediterranean is fundamental to optimising the design and performance of the detector. This paper presents measurements of blue and UV light transmission at the ANTARES site taken between 1997 and 2000. The derived values for the scattering length and the angular distribution of particulate scattering were found to be highly correlated, and results are therefore presented in terms of an absorption length;,ab, and an effective scattering length lambda(sct)(eff). The values for blue (UV) light are found to be lambda(abs) similar or equal to 60(26) m, lambda(sct)(eff similar or equal to) 265(122) m, with significant (similar to15%) time variability. Finally, the results of ANTARES simulations showing the effect of these water properties on the anticipated performance of the detector are presented. (C) 2004 Elsevier B.V. All rights reserved.
  •  
2.
  • Aguilar, J A, et al. (author)
  • Study of large hemispherical photomultiplier tubes for the ANTARES neutrino telescope
  • 2005
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 555:1-2, s. 132-141
  • Journal article (peer-reviewed)abstract
    • The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a three-dimensional matrix of 900 large area photomultiplier tubes housed in pressure-resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the photomultiplier tube chosen for ANTARES. (c) 2005 Elsevier B.V. All rights reserved.
  •  
3.
  • Ageron, M., et al. (author)
  • Studies of a full-scale mechanical prototype line for the ANTARES neutrino telescope and tests of a prototype instrument for deep-sea acoustic measurements
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 581:3, s. 695-708
  • Journal article (peer-reviewed)abstract
    • full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented. (c) 2007 Elsevier B.V. All rights reserved.
  •  
4.
  • Ageron, M., et al. (author)
  • The ANTARES optical beacon system
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 578:3, s. 498-509
  • Journal article (peer-reviewed)abstract
    • ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented. (C) 2007 Elsevier B.V. All rights reserved.
  •  
5.
  • Aguilar, J. A., et al. (author)
  • First results of the instrumentation line for the deep-sea ANTARES neutrino telescope
  • 2006
  • In: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 26:4-5, s. 314-324
  • Journal article (peer-reviewed)abstract
    • In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved.
  •  
6.
  • Aguilar, J. A., et al. (author)
  • The data acquisition system for the ANTARES neutrino telescope
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 570:1, s. 107-116
  • Journal article (peer-reviewed)abstract
    • The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described. (c) 2006 Elsevier B.V. All rights reserved.
  •  
7.
  • Blösch, Günter, et al. (author)
  • Twenty-three unsolved problems in hydrology (UPH) - a community perspective
  • 2019
  • In: Hydrological Sciences Journal. - : Informa UK Limited. - 0262-6667 .- 2150-3435. ; 64:10, s. 1141-1158
  • Journal article (peer-reviewed)abstract
    • This paper is the outcome of a community initiative to identify major unsolved scientific problems in hydrology motivated by a need for stronger harmonisation of research efforts. The procedure involved a public consultation through online media, followed by two workshops through which a large number of potential science questions were collated, prioritised, and synthesised. In spite of the diversity of the participants (230 scientists in total), the process revealed much about community priorities and the state of our science: a preference for continuity in research questions rather than radical departures or redirections from past and current work. Questions remain focused on the process-based understanding of hydrological variability and causality at all space and time scales. Increased attention to environmental change drives a new emphasis on understanding how change propagates across interfaces within the hydrological system and across disciplinary boundaries. In particular, the expansion of the human footprint raises a new set of questions related to human interactions with nature and water cycle feedbacks in the context of complex water management problems. We hope that this reflection and synthesis of the 23 unsolved problems in hydrology will help guide research efforts for some years to come.
  •  
8.
  • Revay, T., et al. (author)
  • Macrocephaly in Bull Spermatozoa Is Associated with Nuclear Vacuoles, Diploidy and Alteration of Chromatin Condensation
  • 2009
  • In: Cytogenetic and Genome Research. - : S. Karger. - 1424-8581 .- 1424-859X. ; 126:1-2, s. 202-209
  • Journal article (peer-reviewed)abstract
    • Spermatozoa from 2 dairy AI (artificial insemination) bulls (A and B), identified by their abnormal spermiogram with cells depicting frequent macrocephaly, double tails and nuclear vacuoles, were case-investigated and compared to normal spermatozoa from a control AI sire (C). Head sizes were measured and morphological abnormalities scored using brightfield and differential interference contrast microscopy. The degree of sperm maturation and of resistance to acid-induced DNA denaturation in situ were determined after uploading of acridine orange using flow cytometry of 5,000 cells/sample. Nuclear fragmentation, i.e. the ratio of red to total (red + green) fluorescence, reached 7.1% and 31% in bulls A and B, compared to 2% in bull C. The proportion of immature spermatozoa, i.e. those with incomplete histone-protamine exchange and depicting higher green fluorescence compared to the main population of the control bull, reached 9.54% in A and 7.75% in B, compared to only 0.47% in the control. In the second part of this study the previously unknown chromosomal constitution of large-headed spermatozoa of bull A was investigated by fluorescence in situ hybridization using an X-Y painting probe set. The 7.5% XY-bearing cells and the presence of diploid spermatozoa detected by flow cytometry indicate a meiotic arrest in the first division in bull A, becoming the first proven case of association of macrocephaly and M1 diploidy. The diverse approaches used for the investigation of spermatozoal DNA provide insights into the etiology of macrocephaly. Copyright (C) 2009 S. Karger AG, Basel
  •  
9.
  • Van Loey, Nancy E., et al. (author)
  • The Burn Specific Health Scale-Brief: Measurement invariant across European countries
  • 2013
  • In: JOURNAL OF TRAUMA AND ACUTE CARE SURGERY. - : Lippincott, Williams and Wilkins. - 2163-0755. ; 74:5, s. 1321-1326
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: The Burn Specific Health Scale Brief (BSHS-B), which is the only multidimensional measure to evaluate burn-specific aspects of health status, has previously been validated in several languages across the world. However, the stability of the underlying construct was not cross-culturally evaluated. The current study reports on measurement invariance across two samples of Swedish and Dutch-speaking patients with burns. less thanbrgreater than less thanbrgreater thanMETHODS: In a prospective study, 231 and 275 Swedish and Dutch-Belgian patients with burns, completed the BSHS-B at 9 or 12 months, respectively, after burn. Using a multigroup confirmatory factor analysis, measurement invariance across languages (Swedish and Dutch) was tested. less thanbrgreater than less thanbrgreater thanRESULTS: The results of the confirmatory factor analysis in the total sample revealed that the scale structure for the earlier reported three-factor structure and the original nine-factor structure was adequate. However, an eight-factor structure in which hand function and simple abilities were merged provided the best fit. This structure was used to test measurement invariance across the two language groups. The two-group outcomes testing measurement invariance across Swedish- and Dutch-speaking patients indicated a stable, configural invariance. less thanbrgreater than less thanbrgreater thanCONCLUSION: The BSHS-B seems to function uniformly across both language groups. The BSHS-B can be used to compare cross-cultural results in both countries.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-9 of 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view