SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rexhepaj Nehat) "

Sökning: WFRF:(Rexhepaj Nehat)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bajraktari, Gani, et al. (författare)
  • Gender related predictors of limited exercise capacity in heart failure
  • 2013
  • Ingår i: IJC Heart & Vessels. - : Elsevier. - 2214-7632. ; 1, s. 11-16
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Aim The aim of this study was to investigate the impact of gender on the prediction of limited exercise capacity in heart failure (HF) patients assessed by 6 minute walk test (6-MWT).Methods In 147 HF patients (mean age 61 ± 11 years, 50.3% male), a 6-MWT and a Doppler echocardiographic study were performed in the same day. Conventional cardiac measurements were obtained and global LV dyssynchrony was indirectly assessed using total isovolumic time − t-IVT [in s/min; calculated as: 60 − (total ejection time − total filling time)] and Tei index (t-IVT/ejection time). Patients were divided into two groups according to gender, which were again divided into two subgroups based on the 6-MWT distance (Group I: ≤ 300 m, and Group II: > 300 m).Results Female patients were younger (p = 0.02), and had higher left ventricular (LV) ejection fraction — EF (p = 0.007) but with similar 6-MWT distance to male patients (p = 68). Group I male patients had lower hemoglobin level (p = 0.02) and lower EF (p = 0.03), compared with Group II, but none of the clinical or echocardiographic variables differed between groups in female patients. In multivariate analysis, only t-IVT [0.699 (0.552–0.886), p = 0.003], and LV EF [0.908 (0.835–0.987), p = 0.02] in males, and NYHA functional class [4.439 (2.213–16.24), p = 0.02] in females independently predicted poor 6-MWT distance (< 300 m).Conclusion Despite similar limited exercise capacity, gender determines the pattern of underlying cardiac disturbances; ventricular dysfunction in males and subjective NYHA class in female heart failure patients.
  •  
2.
  • Bajraktari, Gani, et al. (författare)
  • Left ventricular asynchrony and raised filling pressure predict limited exercise performance assessed by 6 minute walk test
  • 2011
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273 .- 1874-1754. ; 146:3, s. 385-389
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Six minute walking test (6-MWT) may serve as a reproducible test for assessing exercise capacity in heart failure (HF) patients and can be clinically predicted. We aimed in this study to ascertain if global markers of ventricular asynchrony can predict 6MWT distance in a group of patients with HF and left ventricular (LV) ejection fraction (EF) <45%.METHODS AND RESULTS: This study included 77 consecutive patients (60+/-12 years) with stable HF. LV end-diastolic and end-systolic dimensions, shortening fraction (SF), EF, myocardial velocities, t-IVT, and Tei index were measured, as well as 6-MWT distance. Patients with limited exercise performance (CONCLUSIONS: In heart failure patients, the higher the filling pressures and the more asynchronous the left ventricle, the poorer is the patient's exercise capacity. These findings highlight specific LV functional disturbances that should be targeted for better optimization of medical and/or electrical therapy.
  •  
3.
  • Berisha, Gëzim, et al. (författare)
  • Impaired left atrial reservoir function in metbolic syndrome predicts symptoms in HFpEF patients
  • 2015
  • Ingår i: International Cardiovascular Forum Journal. - : Barcaray Publishing. - 2410-2636 .- 2409-3424. ; 4, s. 37-42
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Aim. The Metabolic Syndrome (MetS) has been shown to be independently associated with increased risk for incident heart failure (HF) and coronary artery disease. The aim of this study was to investigate the additional effect of MetS on LA dysfunction in a group of patients with HF and preserved ejection fraction (HFpEF) and its relationship with symptoms.Methods. This study included 194 consecutive patients (age 62 ± 9 years) with stable HFpEF. LV dimensions, ejection fraction (EF), mitral annulus peak systolic excursion (MAPSE), myocardial velocities (s’, e’ and a’), LA dimensions and volumes were measured. Total LA emptying fraction (LA EF) was measured by Simpson rule volumes. Based on the NCEP-ATP III criteria, patients were divided into two groups; MetS (n=95) and non-MetS (n=108) and were compared with 34 age and gender matched controls.Results. Age and gender were not different between patients and control neither between MetS and non-Met. LV dimensions, EF and longitudinal function indices were also not different. The MetS patients had higher LV mass index (p=0.038), lower septal and lateral e’ (p=0.003 and p=0.001, respectively) velocities, larger LA minimal volume (p=0.007) and lower LA EF (p<0.001) compared with the non-MetS patients. Age, LA EF and MetS independently predicted the NYHA class.Conclusions. Despite no difference in LV systolic function, patients with HFpEF and MetS have worse LA emptying fraction, compared with HFpEF and non-MetS patients. In addition, LA reservoir function impairment and MetS independently predict patients limiting symptoms, thus add to a better understanding of HFpEF.
  •  
4.
  • Bytyci, Ibadete, et al. (författare)
  • Left atrial emptying fraction predicts limited exercise performance in heart failure patients
  • 2014
  • Ingår i: IJC Heart and Vessels. - : Elsevier. - 2214-7632. ; 4, s. 203-207
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: We aimed in this study to assess the role of left atrial (LA), in addition to left ventricular (LV) indices, in predicting exercise capacity in patients with heart failure (HF). Methods: This study included 88 consecutive patients (60 ± 10 years) with stable HF. LV end-diastolic and end-systolic dimensions, ejection fraction (EF), mitral and tricuspid annulus peak systolic excursion (MAPSE and TAPSE), myocardial velocities (s′, e′ and a′), LA dimensions, LA volume and LA emptying fraction were measured. A 6-min walking test (6-MWT) distance was performed on the same day of the echocardiographic examination. Results: Patients with limited exercise performance (≤ 300 m) were older (p = 0.01), had higher NYHA functional class (p = 0.004), higher LV mass index (p = 0.003), larger LA (p = 0.002), lower LV EF (p = 0.009), larger LV end-systolic dimension (p = 0.007), higher E/A ratio (p = 0.03), reduced septal MAPSE (p < 0.001), larger LA end-systolic volume (p = 0.03), larger LA end-diastolic volume (p = 0.005) and lower LA emptying fraction (p < 0.001) compared with good performance patients. In multivariate analysis, only the LA emptying fraction [0.944 (0.898–0.993), p = 0.025] independently predicted poor exercise performance. An LA emptying fraction < 60% was 68% sensitive and 73% specific (AUC 0.73, p < 0.001) in predicting poor exercise performance. Conclusion: In heart failure patients, the impaired LA emptying function is the best predictor of poor exercise capacity. This finding highlights the need for routine LA size and function monitoring for better optimization of medical therapy in HF.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy