SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rigaud V.) "

Sökning: WFRF:(Rigaud V.)

  • Resultat 1-14 av 14
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aguilar, J A, et al. (författare)
  • Study of large hemispherical photomultiplier tubes for the ANTARES neutrino telescope
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 555:1-2, s. 132-141
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a three-dimensional matrix of 900 large area photomultiplier tubes housed in pressure-resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the photomultiplier tube chosen for ANTARES. (c) 2005 Elsevier B.V. All rights reserved.
  •  
2.
  •  
3.
  • Ageron, M., et al. (författare)
  • The ANTARES optical beacon system
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 578:3, s. 498-509
  • Tidskriftsartikel (refereegranskat)abstract
    • ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented. (C) 2007 Elsevier B.V. All rights reserved.
  •  
4.
  • Aguilar, J. A., et al. (författare)
  • First results of the instrumentation line for the deep-sea ANTARES neutrino telescope
  • 2006
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 26:4-5, s. 314-324
  • Tidskriftsartikel (refereegranskat)abstract
    • In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved.
  •  
5.
  • Aguilar, J. A., et al. (författare)
  • The data acquisition system for the ANTARES neutrino telescope
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 570:1, s. 107-116
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described. (c) 2006 Elsevier B.V. All rights reserved.
  •  
6.
  • Ageron, M., et al. (författare)
  • ANTARES : The first undersea neutrino telescope
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 656:1, s. 11-38
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES Neutrino Telescope was completed in May 2008 and is the first operational Neutrino Telescope in the Mediterranean Sea. The main purpose of the detector is to perform neutrino astronomy and the apparatus also offers facilities for marine and Earth sciences. This paper describes the design, the construction and the installation of the telescope in the deep sea, offshore from Toulon in France. An illustration of the detector performance is given. (C) 2011 Elsevier B.V. All rights reserved.
  •  
7.
  • Ageron, M., et al. (författare)
  • Studies of a full-scale mechanical prototype line for the ANTARES neutrino telescope and tests of a prototype instrument for deep-sea acoustic measurements
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 581:3, s. 695-708
  • Tidskriftsartikel (refereegranskat)abstract
    • full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented. (c) 2007 Elsevier B.V. All rights reserved.
  •  
8.
  •  
9.
  • Tabiri, S, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
10.
  • Bravo, L, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
11.
  • 2021
  • swepub:Mat__t
  •  
12.
  •  
13.
  • Oza, Amit M., et al. (författare)
  • Quality of life in patients with recurrent ovarian cancer treated with niraparib versus placebo (ENGOT-OV16/NOVA) : results from a double-blind, phase 3, randomised controlled trial
  • 2018
  • Ingår i: The Lancet Oncology. - 1470-2045. ; 19:8, s. 1117-1125
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Quality of life (QOL) has become an important complementary endpoint in cancer clinical studies alongside more traditional assessments (eg, tumour response, progression-free survival, overall survival). Niraparib maintenance treatment has been shown to significantly improve progression-free survival in patients with recurrent ovarian cancer. We aimed to assess whether the benefits of extending progression-free survival are offset by treatment-associated toxic effects that affect QOL. Methods: The ENGOT-OV16/NOVA trial was a multicentre, double-blind, phase 3, randomised controlled trial done in 107 study sites in the USA, Canada, Europe, and Israel. Patients with recurrent ovarian cancer who were in response to their last platinum-based chemotherapy were randomly assigned (2:1) to receive either niraparib (300 mg once daily) as a maintenance treatment or placebo. Randomisation was stratified based on time to progression after the penultimate platinum-based regimen, previous use of bevacizumab, and best response (complete or partial) to the last platinum-based regimen with permuted-block randomisation (six in each block) using an interactive web response system. The trial enrolled two independent cohorts on the basis of germline BRCA (gBRCA) mutation status (determined by BRACAnalysis Testing, Myriad Genetics, Salt Lake City, UT, USA). The primary endpoint of the trial was progression-free survival, and has already been reported. In this study, we assessed patient-reported outcomes (PROs) in the intention-to-treat population using the Functional Assessment of Cancer Therapy–Ovarian Symptoms Index (FOSI) and European QOL five-dimension five-level questionnaire (EQ-5D-5L). We collected PROs from trial entry every 8 weeks for the first 14 cycles and every 12 weeks thereafter. If a patient discontinued, we collected PROs at discontinuation and during a postprogression visit 8 weeks (plus or minus 2 weeks) later. We assessed the effect of haematological toxic effects on QOL with disutility analyses of the most common grade 3–4 adverse events (thrombocytopenia, anaemia, and neutropenia) using a mixed model with histology, region, previous treatment, age, planned treatment, and baseline score as covariates. This study is registered with ClinicalTrials.gov, number NCT01847274. Findings: Between Aug 28, 2013, and June 1, 2015, 553 patients were enrolled and randomly assigned to receive niraparib (n=138 in the gBRCAmut cohort, n=234 in the non-gBRCAmut cohort) or placebo (n=65 in the gBRCAmut cohort, n=116 in the non-gBRCAmut cohort). The mean FOSI score at baseline was similar between the two groups (range between 25·0–25·6 in the two groups). Overall QOL scores remained stable during the treatment and preprogression period in the niraparib group; no significant differences were observed between the niraparib and placebo group, and preprogression EQ-5D-5L scores were similar between the two groups in both cohorts (0·838 [0·0097] in the niraparib group vs 0·834 [0·0173] in the placebo group in the gBRCAmut cohort; and 0·833 [0·0077] in the niraparib group vs 0·815 [0·0122] in the placebo group in the non-gBRCAmut cohort). The most common adverse events reported at screening (baseline) were lack of energy (425 [79%]; 97 [18%] reporting severe lack of energy), pain (236 [44%]), and nausea (118 [22%]). All symptoms, except nausea, either remained stable or improved over time in the niraparib group. The most common grade 3 or 4 toxicities observed in the niraparib group were haematological in nature: thrombocytopenia (124 [34%] of 367 patients), anaemia (93 [25%]), and neutropenia (72 [20%]); disutility analyses showed no significant QOL impairment associated with these toxic effects. Interpretation: These PRO data suggest that women who receive niraparib as maintenance treatment for recurrent ovarian cancer after responding to platinum treatment are able to maintain QOL during their treatment when compared with placebo. Funding: TESARO.
  •  
14.
  • Vermunt, L., et al. (författare)
  • Duration of preclinical, prodromal, and dementia stages of Alzheimer's disease in relation to age, sex, and APOE genotype
  • 2019
  • Ingår i: Alzheimers & Dementia. - : Wiley. - 1552-5260 .- 1552-5279. ; 15:7, s. 888-898
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: We estimated the age-specific duration of the preclinical, prodromal, and dementia stages of Alzheimer's disease (AD) and the influence of sex, setting, apolipoprotein E (APOE) genotype, and cerebrospinal fluid tau on disease duration. Methods: We performed multistate modeling in a combined sample of 6 cohorts (n = 3268) with death as the end stage and estimated the preclinical, prodromal, and dementia stage duration. Results: The overall AD duration varied between 24 years (age 60) and 15 years (age 80). For individuals presenting with preclinical AD, age 70, the estimated preclinical AD duration was 10 years, prodromal AD 4 years, and dementia 6 years. Male sex, clinical setting, APOE epsilon 4 allele carriership, and abnormal cerebrospinal fluid tau were associated with a shorter duration, and these effects depended on disease stage. Discussion: Estimates of AD disease duration become more accurate if age, sex, setting, APOE, and cerebrospinal fluid tau are taken into account. This will be relevant for clinical practice and trial design. (C) 2019 the Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-14 av 14

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy