SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Romero PR) "

Sökning: WFRF:(Romero PR)

  • Resultat 1-28 av 28
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
4.
  • Glasbey, JC, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
5.
  • 2021
  • swepub:Mat__t
  •  
6.
  • Abel, I, et al. (författare)
  • Overview of the JET results with the ITER-like wall
  • 2013
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 1741-4326 .- 0029-5515. ; 53:10, s. 104002-
  • Tidskriftsartikel (refereegranskat)abstract
    • Following the completion in May 2011 of the shutdown for the installation of the beryllium wall and the tungsten divertor, the first set of JET campaigns have addressed the investigation of the retention properties and the development of operational scenarios with the new plasma-facing materials. The large reduction in the carbon content (more than a factor ten) led to a much lower Z(eff) (1.2-1.4) during L- and H-mode plasmas, and radiation during the burn-through phase of the plasma initiation with the consequence that breakdown failures are almost absent. Gas balance experiments have shown that the fuel retention rate with the new wall is substantially reduced with respect to the C wall. The re-establishment of the baseline H-mode and hybrid scenarios compatible with the new wall has required an optimization of the control of metallic impurity sources and heat loads. Stable type-I ELMy H-mode regimes with H-98,H-y2 close to 1 and beta(N) similar to 1.6 have been achieved using gas injection. ELM frequency is a key factor for the control of the metallic impurity accumulation. Pedestal temperatures tend to be lower with the new wall, leading to reduced confinement, but nitrogen seeding restores high pedestal temperatures and confinement. Compared with the carbon wall, major disruptions with the new wall show a lower radiated power and a slower current quench. The higher heat loads on Be wall plasma-facing components due to lower radiation made the routine use of massive gas injection for disruption mitigation essential.
  •  
7.
  •  
8.
  • Romanelli, F, et al. (författare)
  • Overview of the JET results
  • 2011
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 1741-4326 .- 0029-5515. ; 51:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Since the last IAEA Conference JET has been in operation for one year with a programmatic focus on the qualification of ITER operating scenarios, the consolidation of ITER design choices and preparation for plasma operation with the ITER-like wall presently being installed in JET. Good progress has been achieved, including stationary ELMy H-mode operation at 4.5 MA. The high confinement hybrid scenario has been extended to high triangularity, lower ρ*and to pulse lengths comparable to the resistive time. The steady-state scenario has also been extended to lower ρ*and ν*and optimized to simultaneously achieve, under stationary conditions, ITER-like values of all other relevant normalized parameters. A dedicated helium campaign has allowed key aspects of plasma control and H-mode operation for the ITER non-activated phase to be evaluated. Effective sawtooth control by fast ions has been demonstrated with3He minority ICRH, a scenario with negligible minority current drive. Edge localized mode (ELM) control studies using external n = 1 and n = 2 perturbation fields have found a resonance effect in ELM frequency for specific q95values. Complete ELM suppression has, however, not been observed, even with an edge Chirikov parameter larger than 1. Pellet ELM pacing has been demonstrated and the minimum pellet size needed to trigger an ELM has been estimated. For both natural and mitigated ELMs a broadening of the divertor ELM-wetted area with increasing ELM size has been found. In disruption studies with massive gas injection up to 50% of the thermal energy could be radiated before, and 20% during, the thermal quench. Halo currents could be reduced by 60% and, using argon/deuterium and neon/deuterium gas mixtures, runaway electron generation could be avoided. Most objectives of the ITER-like ICRH antenna have been demonstrated; matching with closely packed straps, ELM resilience, scattering matrix arc detection and operation at high power density (6.2 MW m-2) and antenna strap voltages (42 kV). Coupling measurements are in very good agreement with TOPICA modelling. © 2011 IAEA, Vienna.
  •  
9.
  • 2021
  • swepub:Mat__t
  •  
10.
  •  
11.
  •  
12.
  •  
13.
  •  
14.
  •  
15.
  •  
16.
  •  
17.
  •  
18.
  •  
19.
  •  
20.
  • Hanly, JG, et al. (författare)
  • Prospective analysis of neuropsychiatric events in an international disease inception cohort of patients with systemic lupus erythematosus
  • 2010
  • Ingår i: Annals of the rheumatic diseases. - : BMJ. - 1468-2060 .- 0003-4967. ; 69:3, s. 529-535
  • Tidskriftsartikel (refereegranskat)abstract
    • To determine the frequency, accrual, attribution and outcome of neuropsychiatric (NP) events and impact on quality of life over 3 years in a large inception cohort of patients with systemic lupus erythematosus (SLE).MethodsThe study was conducted by the Systemic Lupus International Collaborating Clinics. Patients were enrolled within 15 months of SLE diagnosis. NP events were identified using the American College of Rheumatology case definitions, and decision rules were derived to determine the proportion of NP disease attributable to SLE. The outcome of NP events was recorded and patient-perceived impact determined by the SF-36.Results1206 patients (89.6% female) with a mean (±SD) age of 34.5±13.2 years were included in the study. The mean disease duration at enrolment was 5.4±4.2 months. Over a mean follow-up of 1.9±1.2 years, 486/1206 (40.3%) patients had ≥1 NP events, which were attributed to SLE in 13.0–23.6% of patients using two a priori decision rules. The frequency of individual NP events varied from 47.1% (headache) to 0% (myasthenia gravis). The outcome was significantly better for those NP events attributed to SLE, especially if they occurred within 1.5 years of the diagnosis of SLE. Patients with NP events, regardless of attribution, had significantly lower summary scores for both mental and physical health over the study.ConclusionsNP events in patients with SLE are of variable frequency, most commonly present early in the disease course and adversely impact patients' quality of life over time. Events attributed to non-SLE causes are more common than those due to SLE, although the latter have a more favourable outcome.
  •  
21.
  •  
22.
  •  
23.
  • Hanly, JG, et al. (författare)
  • SF-36 summary and subscale scores are reliable outcomes of neuropsychiatric events in systemic lupus erythematosus
  • 2011
  • Ingår i: Annals of the rheumatic diseases. - : BMJ. - 1468-2060 .- 0003-4967. ; 70:6, s. 961-967
  • Tidskriftsartikel (refereegranskat)abstract
    • To examine change in health-related quality of life in association with clinical outcomes of neuropsychiatric events in systemic lupus erythematosus (SLE).MethodsAn international study evaluated newly diagnosed SLE patients for neuropsychiatric events attributed to SLE and non-SLE causes. The outcome of events was determined by a physician-completed seven-point scale and compared with patient-completed Short Form 36 (SF-36) health survey questionnaires. Statistical analysis used linear mixed-effects regression models with patient-specific random effects.Results274 patients (92% female; 68% Caucasian), from a cohort of 1400, had one or more neuropsychiatric event in which the interval between assessments was 12.3±2 months. The overall difference in change between visits in mental component summary (MCS) scores of the SF-36 was significant (p<0.0001) following adjustments for gender, ethnicity, centre and previous score. A consistent improvement in neuropsychiatric status (N=295) was associated with an increase in the mean (SD) adjusted MCS score of 3.66 (0.89) in SF-36 scores. Between paired visits when the neuropsychiatric status consistently deteriorated (N=30), the adjusted MCS score decreased by 4.00 (1.96). For the physical component summary scores the corresponding changes were +1.73 (0.71) and −0.62 (1.58) (p<0.05), respectively. Changes in SF-36 subscales were in the same direction (p<0.05; with the exception of role physical). Sensitivity analyses confirmed these findings. Adjustment for age, education, medications, SLE disease activity, organ damage, disease duration, attribution and characteristics of neuropsychiatric events did not substantially alter the results.ConclusionChanges in SF-36 summary and subscale scores, in particular those related to mental health, are strongly associated with the clinical outcome of neuropsychiatric events in SLE patients.
  •  
24.
  •  
25.
  •  
26.
  •  
27.
  •  
28.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-28 av 28

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy