SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Rudolph Tanja) "

Search: WFRF:(Rudolph Tanja)

  • Result 1-11 of 11
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Droppa, Michal, et al. (author)
  • Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis
  • 2020
  • In: Heart and Vessels. - : Springer. - 0910-8327 .- 1615-2573. ; 35, s. 1735-1745
  • Journal article (peer-reviewed)abstract
    • Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%;p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes. Clinical Trial: NCT03497611.
  •  
2.
  • Elkoumy, Ahmed, et al. (author)
  • ACURATE neo2 Transcatheter aortic valve implantation without balloon aortic valvuloplasty : direct ACURATE neo2
  • 2024
  • In: International Journal of Cardiology. - 0167-5273 .- 1874-1754. ; 400
  • Journal article (peer-reviewed)abstract
    • Background: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. Aim: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. Methodology: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. Results: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. Conclusion: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.
  •  
3.
  • Escaned, Javier, et al. (author)
  • Applied coronary physiology for planning and guidance of percutaneous coronary interventions. A clinical consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) of the European Society of Cardiology
  • 2023
  • In: EuroIntervention. - : Europa Digital & Publishing. - 1774-024X .- 1969-6213. ; 19:6, s. 464-
  • Journal article (peer-reviewed)abstract
    • The clinical value of fractional flow reserve and non-hyperaemic pressure ratios are well established in determining an indication for percutaneous coronary intervention (PCI) in patients with coronary artery disease (CAD). In addition, over the last 5 years we have witnessed a shift towards the use of physio-logy to enhance procedural planning, assess post-PCI functional results, and guide PCI optimisation. In this regard, clinical studies have reported compelling data supporting the use of longitudinal vessel analysis, obtained with pressure guidewire pullbacks, to better understand how obstructive CAD contributes to myocardial ischaemia, to establish the likelihood of functionally successful PCI, to identify the presence and location of residual flow-limiting stenoses and to predict long-term outcomes. The introduction of new functional coronary angiography tools, which merge angiographic information with fluid dynamic equations to deliver information equivalent to intracoronary pressure measurements, are now available and potentially also applicable to these endeavours. Furthermore, the ability of longitudinal vessel analysis to predict the functional results of stenting has played an integral role in the evolving field of simulated PCI. Nevertheless, it is important to have an awareness of the value and challenges of physiology-guided PCI in specific clinical and anatomical contexts. The main aim of this European Association of Percutaneous Cardiovascular Interventions clinical consensus statement is to offer up-to-date evidence and expert opin-ion on the use of applied coronary physiology for procedural PCI planning, disease pattern recognition and post-PCI optimisation.
  •  
4.
  • Hollestelle, Antoinette, et al. (author)
  • No clinical utility of KRAS variant rs61764370 for ovarian or breast cancer
  • 2016
  • In: Gynecologic Oncology. - : Elsevier BV. - 0090-8258 .- 1095-6859. ; 141:2, s. 386-401
  • Journal article (peer-reviewed)abstract
    • Objective Clinical genetic testing is commercially available for rs61764370, an inherited variant residing in a KRAS 3′ UTR microRNA binding site, based on suggested associations with increased ovarian and breast cancer risk as well as with survival time. However, prior studies, emphasizing particular subgroups, were relatively small. Therefore, we comprehensively evaluated ovarian and breast cancer risks as well as clinical outcome associated with rs61764370. Methods Centralized genotyping and analysis were performed for 140,012 women enrolled in the Ovarian Cancer Association Consortium (15,357 ovarian cancer patients; 30,816 controls), the Breast Cancer Association Consortium (33,530 breast cancer patients; 37,640 controls), and the Consortium of Modifiers of BRCA1 and BRCA2 (14,765 BRCA1 and 7904 BRCA2 mutation carriers). Results We found no association with risk of ovarian cancer (OR = 0.99, 95% CI 0.94-1.04, p = 0.74) or breast cancer (OR = 0.98, 95% CI 0.94-1.01, p = 0.19) and results were consistent among mutation carriers (BRCA1, ovarian cancer HR = 1.09, 95% CI 0.97-1.23, p = 0.14, breast cancer HR = 1.04, 95% CI 0.97-1.12, p = 0.27; BRCA2, ovarian cancer HR = 0.89, 95% CI 0.71-1.13, p = 0.34, breast cancer HR = 1.06, 95% CI 0.94-1.19, p = 0.35). Null results were also obtained for associations with overall survival following ovarian cancer (HR = 0.94, 95% CI 0.83-1.07, p = 0.38), breast cancer (HR = 0.96, 95% CI 0.87-1.06, p = 0.38), and all other previously-reported associations. Conclusions rs61764370 is not associated with risk of ovarian or breast cancer nor with clinical outcome for patients with these cancers. Therefore, genotyping this variant has no clinical utility related to the prediction or management of these cancers.
  •  
5.
  • Kilpeläinen, Tuomas O, et al. (author)
  • Genome-wide meta-analysis uncovers novel loci influencing circulating leptin levels
  • 2016
  • In: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 7
  • Journal article (peer-reviewed)abstract
    • Leptin is an adipocyte-secreted hormone, the circulating levels of which correlate closely with overall adiposity. Although rare mutations in the leptin (LEP) gene are well known to cause leptin deficiency and severe obesity, no common loci regulating circulating leptin levels have been uncovered. Therefore, we performed a genome-wide association study (GWAS) of circulating leptin levels from 32,161 individuals and followed up loci reaching P<10(-6) in 19,979 additional individuals. We identify five loci robustly associated (P<5 × 10(-8)) with leptin levels in/near LEP, SLC32A1, GCKR, CCNL1 and FTO. Although the association of the FTO obesity locus with leptin levels is abolished by adjustment for BMI, associations of the four other loci are independent of adiposity. The GCKR locus was found associated with multiple metabolic traits in previous GWAS and the CCNL1 locus with birth weight. Knockdown experiments in mouse adipose tissue explants show convincing evidence for adipogenin, a regulator of adipocyte differentiation, as the novel causal gene in the SLC32A1 locus influencing leptin levels. Our findings provide novel insights into the regulation of leptin production by adipose tissue and open new avenues for examining the influence of variation in leptin levels on adiposity and metabolic health.
  •  
6.
  • Kim, Won Keun, et al. (author)
  • Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice : one-yearresults of the ACURATE neo2 PMCF Study
  • 2024
  • In: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. - 1969-6213. ; 20:1, s. 85-94
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).
  •  
7.
  • Lawrenson, Kate, et al. (author)
  • Functional mechanisms underlying pleiotropic risk alleles at the 19p13.1 breast-ovarian cancer susceptibility locus
  • 2016
  • In: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 7
  • Journal article (peer-reviewed)abstract
    • A locus at 19p13 is associated with breast cancer (BC) and ovarian cancer (OC) risk. Here we analyse 438 SNPs in this region in 46,451 BC and 15,438 OC cases, 15,252 BRCA1 mutation carriers and 73,444 controls and identify 13 candidate causal SNPs associated with serous OC (P=9.2 × 10-20), ER-negative BC (P=1.1 × 10-13), BRCA1-associated BC (P=7.7 × 10-16) and triple negative BC (P-diff=2 × 10-5). Genotype-gene expression associations are identified for candidate target genes ANKLE1 (P=2 × 10-3) and ABHD8 (P<2 × 10-3). Chromosome conformation capture identifies interactions between four candidate SNPs and ABHD8, and luciferase assays indicate six risk alleles increased transactivation of the ADHD8 promoter. Targeted deletion of a region containing risk SNP rs56069439 in a putative enhancer induces ANKLE1 downregulation; and mRNA stability assays indicate functional effects for an ANKLE1 3′-UTR SNP. Altogether, these data suggest that multiple SNPs at 19p13 regulate ABHD8 and perhaps ANKLE1 expression, and indicate common mechanisms underlying breast and ovarian cancer risk.
  •  
8.
  • Ludwig, Sebastian, et al. (author)
  • Transcatheter Mitral Valve Replacement versus Medical Therapy for Secondary Mitral Regurgitation: A Propensity Score-Matched Comparison.
  • 2023
  • In: Circulation. Cardiovascular interventions. - 1941-7632. ; 16:6
  • Journal article (peer-reviewed)abstract
    • Background: Transcatheter mitral valve replacement (TMVR) is an emerging therapeutic alternative for patients with secondary mitral regurgitation (MR). Outcomes of TMVR versus guideline-directed medical therapy (GDMT) have not been investigated for this population. This study aimed to compare clinical outcomes of patients with secondary MR undergoing TMVR versus GDMT alone. Methods: The CHOICE-MI registry included patients with MR undergoing TMVR using dedicated devices. Patients with MR etiologies other than secondary MR were excluded. Patients treated with GDMT alone were derived from the control arm of the COAPT trial. We compared outcomes between the TMVR and GDMT groups, using propensity score (PS)-matching to adjust for baseline differences. Results: After PS-matching, 97 patient pairs undergoing TMVR (72.9±8.7 years, 60.8% male, transapical access 91.8%) versus GDMT (73.1±11.0 years, 59.8% male) were compared. At 1 and 2 years, residual MR was ≤1+ in all patients of the TMVR group compared to 6.9% and 7.7%, respectively, in those receiving GDMT alone (both p<0.001). The 2-year rate of HF hospitalization was significantly lower in the TMVR group (32.8% vs. 54.4%, HR 0.59, 95% CI 0.35-0.99; p=0.04). Among survivors, a higher proportion of patients were in NYHA functional class I or II in the TMVR group at 1 year (78.2% vs. 59.7%, p=0.03) and at 2 years (77.8% vs. 53.2%, p=0.09). Two-year mortality was similar in the two groups (TMVR vs. GDMT, 36.8% vs. 40.8%, HR 1.01, 95% CI 0.62-1.64; p=0.98). Conclusions: In this observational comparison, over 2-year follow-up, TMVR using mostly transapical devices in patients with secondary MR was associated with significant reduction of MR, symptomatic improvement, less frequent hospitalizations for HF and similar mortality compared with GDMT.
  •  
9.
  • Rosseel, Liesbeth, et al. (author)
  • Contemporary European practice in transcatheter aortic valve implantation: results from the 2022 European TAVI Pathway Registry.
  • 2023
  • In: Frontiers in cardiovascular medicine. - 2297-055X. ; 10
  • Journal article (peer-reviewed)abstract
    • A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume.The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe.Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice.Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%).Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.
  •  
10.
  • Rück, Andreas, et al. (author)
  • The Early neo2 Registry : Transcatheter Aortic Valve Implantation With ACURATE neo2 in a European Population
  • 2023
  • In: Journal of the American Heart Association. - 2047-9980. ; 12:15
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. METHODS AND RESULTS: The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory–adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. CONCLUSIONS: In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.
  •  
11.
  • Rudolph, Tanja, et al. (author)
  • Modifiable risk factors for permanent pacemaker after transcatheter aortic valve implantation: CONDUCT registry
  • 2023
  • In: Open heart. - : BMJ PUBLISHING GROUP. - 2053-3624. ; 10:1
  • Journal article (peer-reviewed)abstract
    • Objective The onset of new conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is still a relevant adverse event. The main objective of this registry was to identify modifiable procedural risk factors for an improved outcome (lower rate of PPI) after TAVI in patients at high risk of PPI.Methods Patients from four European centres receiving a balloon-expandable TAVI (Edwards SAPIEN 3/3 Ultra) and considered at high risk of PPI (pre-existing conduction disturbance, heavily calcified left ventricular outflow tract or short membranous septum) were prospectively enrolled into registry.Results A total of 300 patients were included: 42 (14.0%) required PPI after TAVI and 258 (86.0%) did not. Patients with PPI had a longer intensive care unit plus intermediate care stay (65.7 vs 16.3 hours, p < 0.001), general ward care stay (6.9 vs 5.3 days, p=0.004) and later discharge (8.6 vs 5.0 days, p < 0.001). Of the baseline variables, only pre-existing right bundle branch block at baseline (OR 6.8, 95% CI 2.5 to 18.1) was significantly associated with PPI in the multivariable analysis. Among procedure-related variables, oversizing had the highest impact on the rate of PPI: higher than manufacturer-recommended sizing, mean area oversizing as well as the use of the 29 mm valve (OR 3.4, 95% CI 1.4 to 8.5, p=0.008) all were significantly associated with PPI. Rates were higher with the SAPIEN 3 (16.1%) vs SAPIEN 3 Ultra (8.5%), although not statistically significant but potentially associated with valve sizing. Implantation depth and postdelivery balloon dilatation also tended to affect PPI rates but without a statistical significance.Conclusion Valve oversizing is a strong procedure-related risk factor for PPI following TAVI. The clinical impact of the valve type (SAPIEN 3), implantation depth, and postdelivery balloon dilatation did not reach significance and may reflect already refined procedures in the participating centres, giving attention to these avoidable risk factors.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-11 of 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view