SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sabri Muhammad Haziq Mohamad) "

Sökning: WFRF:(Sabri Muhammad Haziq Mohamad)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Baharin, Shamsul Ammar Shamsul, et al. (författare)
  • Microwave and Very High Frequency Radiations of The First Narrow Initial Breakdown
  • 2021
  • Ingår i: 2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA). - : Institute of Electrical and Electronics Engineers (IEEE). - 9781665423465
  • Konferensbidrag (refereegranskat)abstract
    • This paper reports the observation of microwave and very high frequency (VHF) radiation pulses associated with the first narrow (<10us) initial breakdown (IB) pulses of ten negative cloud-to-ground (-CG) flashes. The centre frequency of microwave and VHF sensors was 0.97 GHz and 60 MHz, respectively. We found that all microwave pulses were the initiation event led the first VHF pulses ranging between 0.03187 and 2.57968 mu s and led the first narrow IB pulses ranging between 0.02382 and 2.70202 mu s. Half of the VHF pulses were observed to lead the first narrow IB pulses ranging between 0.03453 and 0.128 mu s. Moreover, polarity of microwave radiation pulses was always positive while the polarity of the first narrow IB pulses always negative. On the other hand, half of VHF radiation pulses had the same polarity as microwave radiation pulses.
  •  
2.
  • Sabri, Muhammad Haziq Mohamad, et al. (författare)
  • Environmental Analysis of Quasi-Static Electric Field Changes of Tropical Lightning Flashes
  • 2019
  • Ingår i: Ekoloji. - 1300-1361. ; 28:107, s. 373-378
  • Tidskriftsartikel (refereegranskat)abstract
    • The environmental conditions leading to the bouncing-wave discharge and the subsequent electron beam remain to be investigated in more detailed future studies. The analysis of quasi-static initial electric field changes (IECs) were found at the beginning of all 24 lightning flashes detected within reversal distance (22 Negative Cloud-to-Ground (–CG) and 2 normal Intra-Cloud (IC) flashes) in a tropical storm on June 15th, 2017 close to our station in Malacca, Malaysia (2.314077° N, 102.318282° E). The IECs durations averaged 4.28 ms for –CG flashes (range 1.48 to 9.45 ms) and averaged 11.30 ms for normal ICs flashes (range 7.24 to 15.35 ms). In comparison to Florida storms, the duration of IECs for –CG and IC flashes were 0.18 ms (range 0.08 to 0.33 ms) and 1.53 ms (range 0.18 to 5.70 ms), respectively. Moreover, the magnitudes of E-change for tropical thunderstorm were 0.13 V/m (range 0.03 to 0.44 V/m) for –CG flashes and -0.20 V/m (range -0.13 to -0.27 V/m) for IC flashes. The E-change magnitudes of tropical flashes are significantly larger than Florida flashes.
  •  
3.
  • Ahmad, Mohd Riduan, et al. (författare)
  • Emission Heights of Narrow Bipolar Events in a Tropical Storm over the Malacca Strait
  • 2017
  • Ingår i: 2017 International Conference On Electrical Engineering And Computer Science (Icecos). - : IEEE. - 9781479976751 - 9781479976768 - 9781479976744 ; , s. 305-309
  • Konferensbidrag (refereegranskat)abstract
    • Emission heights for narrow bipolar events (NBEs) have been reported mostly from observations at mid latitudes but none have been reported from tropical regions. In this paper, we are reporting for the first time the heights of NBE emissions from a tropical storm over the Malacca Strait, a narrow water passage between the Malay Peninsula and Sumatra Island. A total of 49 positive NBEs (+NBEs) were detected from the storm. The NBE activity can be divided into two stages according to the emission heights and radar reflectivity data. The first stage (or S1) lasted for only 6 minutes, started with the first detected NBE, and produced 20 NBEs (41%). The emission heights ranged between 12.0 and 16.7 km. Radar reflectivity data showed that the storm reached maximum values at 55 dBZ within the period S1. In contrast, the second stage (S2) lasted longer (32 minutes) and produced 29 NBEs (59%). The emission heights were lower and ranged from 8.5 to 13.7 km. Radar reflectivity data showed that the storm reached maximum values at 50 dBZ within the period S2.
  •  
4.
  • Yusop, Norbayah, et al. (författare)
  • Cloud-to-Ground lightning observations over the Western Antarctic region
  • 2019
  • Ingår i: Polar Science. - : ELSEVIER. - 1873-9652 .- 1876-4428. ; 20, s. 84-91
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the observations and characterization of Cloud-to-Ground (CG) lightning activity in Western Antarctica in a region that covers the Amundsen/Bellingshausen Sea (ABS), the Antarctic Peninsula (AP) and the Weddell Sea (WS). Lightning data have been collected by a lightning detector (Boltek LD-350) and an atmospheric electric field mill (EFM-100) sensors deployed at the Carlini Base on the Antarctic Peninsula (CARL: 62.23 degrees S, 58.63 degrees W). The flash rate and flash multiplicity were analysed for three different seasons within a 1,000 km range, starting at the end of summer (February 2017) and ending in winter (July 2017). Three storm days for each month (within the 1,000 km radius from the LD sensor) with three composite active thunderstorms (labelled as Storm region A, B, and C) for each day have been selected from a collection of storm days between February and July 2017. A total of 355,899 flashes have been recorded with 156,190 Positive CG and 199,709 Negative CG flashes from these 54 thunderstorms. In total, Positive CG flash counts made up around 43.9% of the total detected CG flashes. Most of the Positive CG flashes (> 80%) had only 1 or 2 strokes with a maximum number of 5. For Negative CG flashes, the average multiplicity and the maximum multiple stroke were 1.2 and 16 respectively. Most CG flashes were detected during the summer and fall months. Positive CG flashes were prevalent in Western Antarctic storms even during the winter. The mean, median and range of the ratio of Positive CG to Negative CG flashes were 0.7, 0.718 and 0.217-1.279, respectively.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy