SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sakse A.) "

Sökning: WFRF:(Sakse A.)

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Sakse, A., et al. (författare)
  • Defects on endoanal ultrasound and anal incontinence after primary repair of fourth-degree anal sphincter rupture: a study of the anal sphincter complex and puborectal muscle
  • 2009
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 34:6, s. 693-698
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To perform three-dimensional endoanal ultrasound (EA US) after primary repair of fourth-degree anal sphincter rupture (ASR) and correlate the sonographic defects with anal incontinence (AI); to measure the axial and sagittal thickness and angle of the puborectal muscle (PRM) as well as the length of the anal canal, and then correlate these measures with AI; and to assess the interobserver measurement agreement between an inexperienced and an experienced sonologist. Methods EAUS was offered to 84 consecutive women, who were asked to answer a validated questionnaire after fourth-degree ASR. AI was graded according to the Wexner score and EA US defects were graded according to the Starck score. Results Sixty-one women (73%) answered the questionnaire. The median (range) follow-up time was 5.1. (1.3-8.7) years. Thirty-three (54%) of these women underwent EAUS and were included in the study. There was no difference in the incontinence scores between women who underwent EA US and those who did not. Eleven of the women who underwent EAUS (33%) were continent, 22 women (67%) had flatus incontinence at least once a month, of whom 12 also had incontinence for liquid stool and two had incontinence for solid stool. The median Wexner score was 2 (range, 0-12). Five of the patients (15%) had no ultrasound defects. All of the patients with Wexner scores >= 4 had a Starck score of >= 10. No association between ultrasound defects and AI was demonstrated, however, the angle of the PRM and parity were associated with Starck score. No clear association between the measurements of the PRM and AI was shown. The experienced observer detected more of the small defects than did the inexperienced observer. Conclusion In a 1-9-year follow-up period after primary suture of fourth-degree ASR, the frequency of A I was high, at 67%. No clear association was seen between AI and sphincter defects detected on ultrasonography. There was an association between the angle of the PRM and the extent of ultrasound defects. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Starck-Söndergaard, ... (1)
Sakse, A. (1)
Secher, N. J. (1)
Ottesen, M. (1)
Lärosäte
Lunds universitet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy