SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sas Korczynska B.) "

Sökning: WFRF:(Sas Korczynska B.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Krzempek, D., et al. (författare)
  • CALIBRATION OF GAFCHROMIC EBT3 FILM FOR DOSIMETRY OF SCANNING PROTON PENCIL BEAM (PBS)
  • 2018
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 180:1-4, s. 324-328
  • Tidskriftsartikel (refereegranskat)abstract
    • Gafchromic EBT3 films are applied in proton radiotherapy for 2D dose mapping because they demonstrate spatial resolution well below 1mm. However, the film response must be corrected in order to reach the accuracy of dose measurements required for the clinical use. The in-house developed AnalyseGafchromic software allows to analyze and correct the measured response using triple channel dose calibration, statistical scan-to-scan fluctuations as well as experimentally determined dose and LET dependence. Finally, the optimized protocol for evaluation of response of Gafchromic EBT3 films was applied to determine 30 x 40 cm(2) dose profiles of the scanning therapy unit at the Cyclotron Centre Bronowice, CCB in Krakow, Poland.
  •  
2.
  • Stock, M., et al. (författare)
  • Harmonization of proton treatment planning for head and neck cancer using pencil beam scanning: first report of the IPACS collaboration group
  • 2019
  • Ingår i: Acta Oncologica. - : Informa UK Limited. - 0284-186X .- 1651-226X. ; 58:12, s. 1720-1730
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: A collaborative network between proton therapy (PT) centres in Trento in Italy, Poland, Austria, Czech Republic and Sweden (IPACS) was founded to implement trials and harmonize PT. This is the first report of IPACS with the aim to show the level of harmonization that can be achieved for proton therapy planning of head and neck (sino-nasal) cancer. Methods: CT-data sets of five patients were included. During several face-to-face and online meetings, a common treatment planning protocol was developed. Each centre used its own treatment planning system (TPS) and planning approach with some restrictions specified in the treatment planning protocol. In addition, volumetric modulated arc therapy (VMAT) photon plans were created. Results: For CTV1, the average D-median was 59.3 +/- 2.4 Gy(RBE) for protons and 58.8 +/- 2.0 Gy(RBE) for VMAT (aim was 56 Gy(RBE)). For CTV2, the average D-median was 71.2 +/- 1.0 Gy(RBE) for protons and 70.6 +/- 0.4 Gy(RBE) for VMAT (aim was 70 Gy(RBE)). The average D-2% for the spinal cord was 25.1 +/- 8.5 Gy(RBE) for protons and 47.6 +/- 1.4 Gy(RBE) for VMAT. The average D-2% for chiasm was 46.5 +/- 4.4 Gy(RBE) for protons and 50.8 +/- 1.4 Gy(RBE) for VMAT, respectively. Robust evaluation was performed and showed the least robust plans for plans with a low number of beams. Discussion: In conclusion, several influences on harmonization were identified: adherence/interpretation to/of the protocol, available technology, experience in treatment planning and use of different beam arrangements. In future, all OARs that should be included in the optimization need to be specified in order to further harmonize treatment planning.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy