SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Scuka V.) "

Sökning: WFRF:(Scuka V.)

  • Resultat 1-34 av 34
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Cooray, V, et al. (författare)
  • Lightning-induced overvoltages in power lines: Validity of various approximations made in overvoltage calculations
  • 1998
  • Ingår i: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 0018-9375. ; 40:4, s. 355-363
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • In this paper, the validity of different approximations used in the calculation of induced overvoltages in power lines are investigated, These approximations are as follows: 1) neglect the distortions introduced by the finitely conducting ground on the el
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Gao, L, et al. (författare)
  • Simulation of streamer discharges as finitely conducting channels
  • 1999
  • Ingår i: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 1070-9878. ; 6:1, s. 35-42
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • This paper presents a two-dimensional simulation of positive streamers in air at atmospheric pressure in a quasi-uniform electric field. A streamer is assumed to consist of a hemispherical tip and a finitely conducting cylindrical channel with a constant
  •  
8.
  •  
9.
  •  
10.
  • Roman, F, et al. (författare)
  • Comparison of the breakdown of rod-plane gaps with floating electrode
  • 1998
  • Ingår i: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 1070-9878. ; 5:4, s. 622-624
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The possible influence of a metal body in a lightning protection system was determined by comparing the electrical breakdown probability of two symmetrical sphere-rod gaps, one conventional and the other with a floating electrode, i.e. a rod with a series
  •  
11.
  • Roman, F, et al. (författare)
  • Corona from floating electrodes
  • 1996
  • Ingår i: JOURNAL OF ELECTROSTATICS. - : ELSEVIER SCIENCE BV. - 0304-3886. ; 37:1-2, s. 67-78
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • It is not unusual to have insulated conducting objects located close to the conductors of a Lightning Protection System. However, the separation of these objects from the Lightning Protection System could vary from a few millimetres to some centimetres. W
  •  
12.
  •  
13.
  • Roman, F, et al. (författare)
  • Increase in the visual corona from floating electrodes
  • 1999
  • Ingår i: JOURNAL OF ELECTROSTATICS. - : ELSEVIER SCIENCE BV. - 0304-3886. ; 45:4, s. 243-254
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The corona and streamer discharges on a floating metallic rod located close to a high-voltage electrode were investigated under the application of both positive and negative 300/3000 mu s switching impulses. The distance between the floating rod and the h
  •  
14.
  •  
15.
  •  
16.
  •  
17.
  •  
18.
  • Bendjamin, J, et al. (författare)
  • Time varying magnetic fields generated by human metal (ESD) electrostatic discharges
  • 1999
  • Ingår i: JOURNAL OF ELECTROSTATICS. - : ELSEVIER SCIENCE BV. - 0304-3886. ; 46:4, s. 259-269
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper it is shown that the magnetic fields very close to an ESD can be predicted by modelling the radiating discharge current path as a sequence of electric dipoles. Time domain measurements of current and magnetic fields generated by human-metal
  •  
19.
  •  
20.
  •  
21.
  •  
22.
  • Larsson, A, et al. (författare)
  • Numerical simulation of gas discharge protectors - A review
  • 1999
  • Ingår i: IEEE TRANSACTIONS ON POWER DELIVERY. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 0885-8977. ; 14:2, s. 405-410
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • This paper gives a review of the efforts that have been made to model the gas discharge protector (gas arrester) for use in computer simulations of surge protector co-ordination in low-voltage power systems.
  •  
23.
  • Larsson, A, et al. (författare)
  • Numerical simulation of transient protector co-ordination
  • 1999
  • Ingår i: EUROPEAN TRANSACTIONS ON ELECTRICAL POWER. - : VDE VERLAG GMBH. - 1430-144X. ; 9:1, s. 57-63
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The issue of protection and protection co-ordination is of increasing importance due to the vulnerability of electronic equipment to voltage surges. In order to properly co-ordinate the different protection units of a protection system, all the different
  •  
24.
  • Manyahi, M.J., Thottappillil, R., Scuka, V. (författare)
  • Transient Response of Equipment Transformers
  • 1999
  • Ingår i: proceedings. - : 1999 International Conference on Electrical Engineering and Technology, Dar Es Salaam, Tanzania.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
  •  
25.
  • Tang, H, et al. (författare)
  • The breakdown mechanism of a mid-plane triggered spark gap trigatron
  • 1996
  • Ingår i: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 1070-9878. ; 3:6, s. 843-848
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • A mid-plane triggered spark gap trigatron prototype with adjustable main gap distance and replaceable trigger electrode was constructed and experimentally investigated. The electric parameter measurements, the luminosity measurements and the streak image
  •  
26.
  • Tang, H, et al. (författare)
  • Time-domain study of a shielding cable system with a nonlinear load
  • 1999
  • Ingår i: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 0018-9375. ; 41:3, s. 214-220
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • An impulse current of several kiloamperes was injected to the shield of a shielded cable, which was terminated by a varistor. The induced voltage on the inner conductor caused by this impulse current reaches an amplitude in excess of the varistor's thresh
  •  
27.
  •  
28.
  •  
29.
  •  
30.
  •  
31.
  •  
32.
  •  
33.
  • Zitnik, M, et al. (författare)
  • Degradation of low-voltage ZnO varistors
  • 1998
  • Ingår i: 24th International Conference on Lightning Protection (ICLP), Birmingham, UK, Sept 14-18. ; , s. 784-789
  • Konferensbidrag (refereegranskat)
  •  
34.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-34 av 34

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy