SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Serna Franco J.) "

Sökning: WFRF:(Serna Franco J.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abdalla, H., et al. (författare)
  • TeV Emission of Galactic Plane Sources with HAWC and HESS
  • 2021
  • Ingår i: Astrophysical Journal. - : Institute of Physics Publishing (IOPP). - 0004-637X .- 1538-4357. ; 917:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The High Altitude Water Cherenkov (HAWC) observatory and the High Energy Stereoscopic System (H.E.S.S.) are two leading instruments in the ground-based very-high-energy gamma-ray domain. HAWC employs the water Cherenkov detection (WCD) technique, while H.E.S.S. is an array of Imaging Atmospheric Cherenkov Telescopes (IACTs). The two facilities therefore differ in multiple aspects, including their observation strategy, the size of their field of view, and their angular resolution, leading to different analysis approaches. Until now, it has been unclear if the results of observations by both types of instruments are consistent: several of the recently discovered HAWC sources have been followed up by IACTs, resulting in a confirmed detection only in a minority of cases. With this paper, we go further and try to resolve the tensions between previous results by performing a new analysis of the H.E.S.S. Galactic plane survey data, applying an analysis technique comparable between H.E.S.S. and HAWC. Events above 1 TeV are selected for both data sets, the point-spread function of H.E.S.S. is broadened to approach that of HAWC, and a similar background estimation method is used. This is the first detailed comparison of the Galactic plane observed by both instruments. H.E.S.S. can confirm the gamma-ray emission of four HAWC sources among seven previously undetected by IACTs, while the three others have measured fluxes below the sensitivity of the H.E.S.S. data set. Remaining differences in the overall gamma-ray flux can be explained by the systematic uncertainties. Therefore, we confirm a consistent view of the gamma-ray sky between WCD and IACT techniques.
  •  
2.
  • Ordoñez, Carlos A., et al. (författare)
  • Critical systolic blood pressure threshold for endovascular aortic occlusion : A multinational analysis to determine when to place a REBOA
  • 2024
  • Ingår i: Journal of Trauma and Acute Care Surgery. - : Lippincott Williams & Wilkins. - 2163-0755 .- 2163-0763. ; 96:2, s. 247-255
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Systolic blood pressure (SBP) is a potential indicator that could guide when to use a resuscitative endovascular balloon occlusion of the aorta (REBOA) in trauma patients with life-threatening injuries. This study aims to determine the optimal SBP threshold for REBOA placement by analyzing the association between SBP pre-REBOA and 24-hour mortality in severely injured hemodynamically unstable trauma patients.METHODS: We performed a pooled analysis of the Aortic Balloon Occlusion (ABO) trauma and AORTA registries. These databases record the details related to the use of REBOA and include data from 14 countries worldwide. We included patients who had suffered penetrating and/or blunt trauma. Patients who arrived at the hospital with a SBP pre-REBOA of 0 mm Hg and remained at 0 mm Hg after balloon inflation were excluded. We evaluated the impact that SBP pre-REBOA had on the probability of death in the first 24 hours.RESULTS: A total of 1107 patients underwent endovascular aortic occlusion, of these, 848 met inclusion criteria. The median age was 44 years [IQR, 27-59 years] and 643(76%) were male. The median injury severity score was 34 [IQR, 25-45]. The median SBP pre-REBOA was 65 mm Hg [IQR: 49-88 mm Hg]. Mortality at 24-hours was reported in 279 (32%) patients. Math modelling shows that predicted probabilities of the primary outcome increased steadily in SBP pre-REBOA below 100 mm Hg. Multivariable mixed-effects analysis shows that when SBP pre-REBOA was lower than 60 mm Hg, the risk of death was more than 50% (relative risk, 1.5; 95%CI, 1.17-1.92; P = .001).DISCUSSION: In patients who do not respond to initial resuscitation, the use of REBOA in SBP's between 60- and 80-mm Hg may be a useful tool in resuscitation efforts before further decompensation or complete cardiovascular collapse. The findings from our study are clinically important as a first step in identifying candidates for REBOA.STUDY TYPE: Observational Study. LEVEL OF EVIDENCE: Level IV.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy