  • Bjällmark, Anna, et al. (författare)
  • Differences in myocardial velocities during supine and upright exercise stress echocardiography in healthy adults
  • 2009
  • Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961 .- 1475-097X. ; 29:3, s. 216-223
  • Tidskriftsartikel (refereegranskat)abstract
    • Tissue Velocity Imaging (TVI) is a method for quantitative analysis of longitudinal myocardial velocities, which can be used during exercise and pharmacological stress echocardiography. It is of interest to evaluate cardiac response to different types of stress tests and the differences between upright and supine bicycle exercise tests have not been fully investigated. Therefore, the aim of this study was to compare cardiac response during supine and upright exercise stress tests. Twenty young healthy individuals underwent supine and upright stress test. The initial workload was set to 30 W and was increased every minute by a further 30 W until physical exhaustion. Tissue Doppler data from the left ventricle were acquired at the end of every workload level using a GE Vivid7 Dimension system (> 200 frames s(-1)). In the off-line processing, isovolumic contraction velocity (IVCV), peak systolic velocity (PSV), isovolumic relaxation velocity (IVRV), peak early diastolic velocity (E') and peak late diastolic velocity (A') were identified at every workload level. No significant difference between the tests was found in PSV. On the contrary, E' was shown to be significantly higher (P < 0.001) during supine exercise than during upright exercise and IVRV was significantly lower (P < 0.001) during supine exercise compared to upright exercise. Upright and supine exercise stress echocardiography give a comparable increase in measured systolic velocities and significant differences in early diastolic velocities.
  •  
2.
  • Bjällmark, Anna, et al. (författare)
  • Ultrasonographic strain imaging is superior to conventional non-invasive measures of vascular stiffness in the detection of age-dependent differences in the mechanical properties of the common carotid artery
  • 2010
  • Ingår i: European Journal of Echocardiography. - : Oxford University Press (OUP). - 1525-2167 .- 1532-2114. ; 11:7, s. 630-636
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Elastic properties of large arteries have been shown to deteriorate with age and in the presence of atherosclerotic vascular disease. In this study, the performance of ultrasonographic strain measurements was compared to conventional measures of vascular stiffness in the detection of age-dependent differences in the elastic properties of the common carotid artery.Methods and results: In 10 younger (25-28 years, 4 women) and 10 older (50-59 years, 4 women) healthy individuals, global and regional circumferential and radial strain variables were measured in the short-axis view of the right common carotid artery using ultrasonographic two-dimensional (2D) strain imaging with recently introduced speckle tracking technique. Conventional elasticity variables, elastic modulus (Ep) and β stiffness index, were calculated using M-mode sonography and non-invasive blood pressure measurements. Global and regional circumferential systolic strain and strain rate values were significantly higher (p < 0.001, p < 0.01 for regional late systolic strain rate) in the younger individuals, whereas the values of conventional elasticity variables in the same group were lower (p < 0.05). Among all strain and conventional elasticity variables, principal component analysis and its regression extension identified only circumferential systolic strain variables as contributing significantly to the observed discrimination between the younger and older age groups.Conclusion: Ultrasonographic 2D-strain imaging is a sensitive method for the assessment of elastic properties in the common carotid artery, being in this respect superior to conventional measures of vascular elasticity. The method has potential to become a valuable non-invasive tool in the detection of early atherosclerotic vascular changes.
  •  
3.
  • da Silva, Cristina, et al. (författare)
  • Hemodynamic outcomes of transcatheter aortic valve implantation with the CoreValve system : an early assessment
  • 2015
  • Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 35:3, s. 216-222
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Aims: Transcatheter aortic valve implantation (TAVI) is an established method for the treatment of high-risk patients with aortic stenosis (AS). The beneficial effects of TAVI in cardiac hemodynamics have been described in recent studies, but those investigations were mostly performed after an interval of more than 6 months following aortic valve implantation. The aim of this study is to investigate the acute and short-term alterations in hemodynamic conditions using the echocardiography outcomes in patients undergoing TAVI. Methods and Results: A total of 60 patients (26 males, 34 females; age 84·7 ± 5·8) who underwent TAVI with CoreValve system were included in the study. Echocardiography was performed before hospital discharge and at 3 months follow-up. As expected, TAVI was associated with an immediate significant improvement in aortic valve area (AVA) (from 0·64 ± 0·16 cm2 to 1·67 ± 0·41 cm2, P-value<0·001) and mean gradient (from 51·9 ± 15·4 mmHg to 8·8 ± 3·8 mmHg, P-value<0·001). At 3-month follow-up, systolic LV function was augmented (EF: 50 ± 14% to 54 ± 11%, P-value = 0·024). Left ventricle (LV) mass and left atrium (LA) volume were significantly reduced (LV mass index from 126·5 ± 30·5 g m-2 to 102·4 ± 32·4 g m-2; LA index from 42·9 ± 17·3 ml m-2 to 33·6 ± 10·6 ml m-2; P-value<0·001 for both). Furthermore, a decrement in systolic pulmonary artery pressure (SPAP) from 47·5 ± 13·5 mmHg to 42·5 ± 11·2 mmHg, P-value = 0·02 was also observed. Despite the high incidence of paravalvular regurgitation (PVR) (80%), most of the patients presented mild or trace PVR and no significant progress of the regurgitation grade was seen after 3 months. Conclusion: This study demonstrates that the beneficial effects of TAVI in cardiac function and hemodynamics occur already after a short period following aortic valve implantation.
  •  
4.
  • da Silva, Cristina, et al. (författare)
  • Prosthesis-patient mismatch after transcatheter aortic valve implantation : impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography
  • 2014
  • Ingår i: The International Journal of Cardiovascular Imaging. - : Springer Science and Business Media LLC. - 1569-5794 .- 1875-8312 .- 1573-0743. ; 30:8, s. 1549-1557
  • Tidskriftsartikel (refereegranskat)abstract
    • To investigate the role of 2D-transthoracic echocardiography (2D-TTE) and 3D-transesophageal echocardiography (3D-TEE) in the determination of aortic annulus size prior transcatheter aortic valve implantation (TAVI) and its' impact on the prevalence of patient prosthesis mismatch (PPM). Echocardiography plays an important role in measuring aortic annulus dimension in patients undergoing TAVI. This has great importance since it determines both eligibility for TAVI and selection of prosthesis type and size, and can be potentially important in preventing an inadequate ratio between the prosthetic valvular orifice and the patient's body surface area, concept known as prosthesis-patient mismatch (PPM). A total of 45 patients were studied pre-TAVI: 20 underwent 3D-TEE (men/women 12/8, age 84.8 +/- A 5.6) and 25 2D-TTE (men/women 9/16, age 84.4 +/- A 5.4) in order to measure aortic annulus diameter. The presence of PPM was assessed before hospital discharge and after a mean period of 3 months. Moderate PPM was defined as indexed aortic valve area (AVAi) a parts per thousand currency sign 0.85 cm(2)/m(2) and severe PPM as AVAi < 0.65 cm(2)/m(2). Immediately post-TAVI, moderate PPM was present in 25 and 28 % of patients worked up using 3D-TEE and 2D-TTE respectively p value = n.s) and severe PPM occurred in 10 % of the patients who underwent 3D-TEE and in 20 % in those with 2D-TTE (p value = n.s). The echocardiographic evaluation 3 months post-TAVI showed 25 % moderate PPM in the 3D-TEE group compared with 24 % in the 2D-TTE group (p value = n.s) and no cases of severe PPM in the 3DTEE group comparing to 20 % in the 2D-TTE group (p = 0.032). Our results indicate a higher incidence of severe PPM in patients who performed 2DTTE compared to those performing 3DTEE prior TAVI. This suggests that the 3D technique should replace the 2DTTE analysis when investigating the aortic annulus diameter in patients undergoing TAVI.
  •  
5.
  • Gudmundsson, Petri, et al. (författare)
  • Head to head comparisons of two modalities of perfusion adenosine stress echocardiography with simultaneous SPECT
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : BioMed Central. - 1476-7120. ; 7:19
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Real-time perfusion (RTP) contrast echocardiography can be used during adenosine stress echocardiography (ASE) to evaluate myocardial ischemia. We compared two different types of RTP power modulation techniques, angiomode (AM) and high-resolution grayscale (HR), with 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia. Methods: Patients with known or suspected coronary artery disease (CAD), admitted to SPECT, were prospectively invited to participate. Patients underwent RTP imaging (SONOS 5500) using AM and HR during Sonovue® infusion, before and throughout the adenosine stress, also used for SPECT. Analysis of myocardial perfusion and wall motion by RTP-ASE were done for AM and HR at different time points, blinded to one another and to SPECT. Each segment was attributed to one of the three main coronary vessel areas of interest. Results: In 50 patients, 150 coronary areas were analyzed by SPECT and RTP-ASE AM and HR. SPECT showed evidence of ischemia in 13 out of 50 patients. There was no significant difference between AM and HR in detecting ischemia (p = 0.08). The agreement for AM and HR, compared to SPECT, was 93% and 96%, with Kappa values of 0.67 and 0.75, respectively (p < 0.001). Conclusion: There was no significant difference between AM and HR in correctly detecting myocardial ischemia as judged by SPECT. This suggests that different types of RTP modalities give comparable data during RTP-ASE in patients with known or suspected CAD.
  •  
6.
  •  
7.
  • Gudmundsson, Petri, et al. (författare)
  • Parametric quantification of myocardial ischaemia using real-time perfusion adenosine stress echocardiography images, with SPECT as reference method
  • 2010
  • Ingår i: Clinical Physiology and Functional Imaging. - : John Wiley & Sons. - 1475-0961 .- 1475-097X. ; 30:1, s. 30-42
  • Tidskriftsartikel (refereegranskat)abstract
    • SUMMARY BACKGROUND: Real-time perfusion (RTP) adenosine stress echocardiography (ASE) can be used to visually evaluate myocardial ischaemia. The RTP power modulation technique, provides images for off-line parametric perfusion quantification using Qontrast software. From replenishment curves, this generates parametric images of peak signal intensity (A), myocardial blood flow velocity (beta) and myocardial blood flow (Axbeta) at rest and stress. This may be a tool for objective myocardial ischaemia evaluation. We assessed myocardial ischaemia by RTP-ASE Qontrast((R))-generated images, using 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) as reference. METHODS: Sixty-seven patients admitted to SPECT underwent RTP-ASE (SONOS 5500) during Sonovue infusion, before and throughout adenosine stress, also used for SPECT. Quantitative off-line analyses of myocardial perfusion by RTP-ASE Qontrast-generated A, beta and Axbeta images, at different time points during rest and stress, were blindly compared to SPECT. RESULTS: We analysed 201 coronary territories [corresponding to the left anterior descendent (LAD), left circumflex (LCx) and right coronary (RCA) arteries] from 67 patients. SPECT showed ischaemia in 18 patients. Receiver operator characteristics and kappa values showed that A, beta and Axbeta image interpretation significantly identified ischaemia in all territories (area under the curve 0.66-0.80, P = 0.001-0.05). Combined A, beta and Axbeta image interpretation gave the best results and the closest agreement was seen in the LAD territory: 89% accuracy; kappa 0.63; P<0.001. CONCLUSION: Myocardial isachemia can be evaluated in the LAD territory using RTP-ASE Qontrast-generated images, especially by combined A, beta and Axbeta image interpretation. However, the technique needs improvements regarding the LCx and RCA territories.
  •  
8.
  •  
9.
  •  
10.
  • Gudmundsson, Petri, et al. (författare)
  • Quantitative detection of myocardial ischaemia by stress echocardiography; a comparison with SPECT
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : BioMed Central. - 1476-7120. ; 7:28
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Real-time perfusion (RTP) adenosine stress echocardiography (ASE) can be used to visually evaluate myocardial ischaemia. The RTP power modulation technique angio-mode (AM), provides images for off-line perfusion quantification using Qontrast® software, generating values of peak signal intensity (A), myocardial blood flow velocity (β) and myocardial blood flow (Axβ). By comparing rest and stress values, their respective reserve values (A-r, β-r, Axβ-r) are generated. We evaluated myocardial ischaemia by RTP-ASE Qontrast® quantification, compared to visual perfusion evaluation with 99mTc-tetrofosmin singlephoton emission computed tomography (SPECT). Methods and Results: Patients admitted to SPECT underwent RTP-ASE (SONOS 5500) using AM during Sonovue® infusion, before and throughout adenosine stress, also used for SPECT. Visual myocardial perfusion and wall motion analysis, and Qontrast® quantification, were blindly compared to one another and to SPECT, at different time points off-line. We analyzed 201 coronary territories (left anterior descendent [LAD], left circumflex [LCx] and right coronary [RCA] artery territories) in 67 patients. SPECT showed ischaemia in 18 patients and 19 territories. Receiver operator characteristics and kappa values showed significant agreement with SPECT only for β-r and Axβ-r in all segments: area under the curve 0.678 and 0.665; P < 0.001 and < 0.01, respectively. The closest agreements were seen in the LAD territory: kappa 0.442 for both β-r and Axβ- r; P < 0.01. Visual evaluation of ischaemia showed good agreement with SPECT: accuracy 93%; kappa 0.67; P < 0.001; without non-interpretable territories. Conclusion: In this agreement study with SPECT, RTP-ASE Qontrast® quantification of myocardial ischaemia was less accurate and less feasible than visual evaluation and needs further development to be clinically useful.
  •  
11.
  • Johnson, Jonas, et al. (författare)
  • Impact of tachycardia and sympathetic stimulation by cold pressor test on cardiac diastology and arterial function in elderly females
  • 2013
  • Ingår i: American Journal of Physiology. Heart and Circulatory Physiology. - : American Physiological Society. - 0363-6135 .- 1522-1539. ; 304:7, s. H1002-H1009
  • Tidskriftsartikel (refereegranskat)abstract
    • Johnson J, Hakansson F, Shahgaldi K, Manouras A, Norman M, Sahlen A. Impact of tachycardia and sympathetic stimulation by cold pressor test on cardiac diastology and arterial function in elderly females. Am J Physiol Heart Circ Physiol 304: H1002-H1009, 2013. First published January 25, 2013; doi:10.1152/ajpheart.00837.2012.-Abnormal vascular-ventricular coupling has been suggested to contribute to heart failure with preserved ejection fraction in elderly females. Failure to increase stroke volume (SV) during exercise occurs in parallel with dynamic changes in arterial physiology leading to increased afterload. Such adverse vascular reactivity during stress may reflect either sympathoexcitation or be due to tachycardia. We hypothesized that afterload elevation induces SV failure by transiently attenuating left ventricular relaxation, a phenomenon described in animal research. The respective roles of tachycardia and sympathoexcitation were investigated in n = 28 elderly females (70 +/- 4 yr) carrying permanent pacemakers. At rest, during atrial tachycardia pacing (ATP; 100 min(-1)) and during cold pressor test (hand immersed in ice water), we performed Doppler echocardiography (maximal untwist rate analyzed by speckle tracking imaging of rotational mechanics) and arterial tonometry (arterial stiffness estimated as augmentation index). Estimation of arterial compliance was based on an exponential relationship between arterial pressure and volume. We found that ATP produced central hypovolemia and a reduction in SV which was larger in patients with stiffer arteries (higher augmentation index). There was an associated adverse response of arterial compliance and vascular resistance during ATP and cold pressor test, causing an overall increase in afterload, but nonetheless enhanced maximal rate of untwist and no evidence of afterload-dependent failure of relaxation. In conclusion, tachycardia and cold provocation in elderly females produces greater vascular reactivity and SV failure in the presence of arterial stiffening, but SV failure does not arise secondary to afterload-dependent attenuation of relaxation.
  •  
12.
  • Lund, Lars H., et al. (författare)
  • Acyl ghrelin improves cardiac function in heart failure and increases fractional shortening in cardiomyocytes without calcium mobilization
  • 2023
  • Ingår i: European Heart Journal. - : Oxford University Press. - 0195-668X .- 1522-9645.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and AimsGhrelin is an endogenous appetite-stimulating peptide hormone with potential cardiovascular benefits. Effects of acylated (activated) ghrelin were assessed in patients with heart failure and reduced ejection fraction (HFrEF) and in ex vivo mouse cardiomyocytes.Methods and resultsIn a randomized placebo-controlled double-blind trial, 31 patients with chronic HFrEF were randomized to synthetic human acyl ghrelin (0.1 µg/kg/min) or placebo intravenously over 120 min. The primary outcome was change in cardiac output (CO). Isolated mouse cardiomyocytes were treated with acyl ghrelin and fractional shortening and calcium transients were assessed. Acyl ghrelin but not placebo increased cardiac output (acyl ghrelin: 4.08 ± 1.15 to 5.23 ± 1.98 L/min; placebo: 4.26 ± 1.23 to 4.11 ± 1.99 L/min, P < 0.001). Acyl ghrelin caused a significant increase in stroke volume and nominal increases in left ventricular ejection fraction and segmental longitudinal strain and tricuspid annular plane systolic excursion. There were no effects on blood pressure, arrhythmias, or ischaemia. Heart rate decreased nominally (acyl ghrelin: 71 ± 11 to 67 ± 11  b.p.m.; placebo 69 ± 8 to 68 ± 10  b.p.m.). In cardiomyocytes, acyl ghrelin increased fractional shortening, did not affect cellular Ca2+ transients, and reduced troponin I phosphorylation. The increase in fractional shortening and reduction in troponin I phosphorylation was blocked by the acyl ghrelin antagonist D-Lys 3.ConclusionIn patients with HFrEF, acyl ghrelin increased cardiac output without causing hypotension, tachycardia, arrhythmia, or ischaemia. In isolated cardiomyocytes, acyl ghrelin increased contractility independently of preload and afterload and without Ca2+ mobilization, which may explain the lack of clinical side effects. Ghrelin treatment should be explored in additional randomized trials.
  •  
13.
  • Magnusson, Martin, et al. (författare)
  • Brain natriuretic peptide is related to diastolic dysfunction whereas urinary albumin excretion rate is related to left ventricular mass in asymptomatic type 2 diabetes patients
  • 2010
  • Ingår i: Cardiovascular Diabetology. - : Springer Science and Business Media LLC. - 1475-2840. ; 9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The aims of this study were to estimate the prevalence of left ventricular systolic (LVSD) and diastolic (LVDD) dysfunction, and to test if BNP and urinary albumin excretion rate (AER) are related to LVSD, LVD and left ventricular mass (LVM) in asymptomatic type 2 diabetes patients. Methods: Presence of LVSD, LVDD and LVM, determined with echocardiography, was related to levels of BNP and AER in 153 consecutive asymptomatic patients with type 2 diabetes. Results: LVSD was present in 6.1% of patients whereas 49% (29% mild, 19% moderate and 0.7% severe) had LVDD and 9.4% had left ventricular hypertrophy. Increasing age (P < 0.0001) was the only independent variable related to mild LVDD whereas increasing BNP (P = 0.01), systolic blood pressure (P = 0.01), age (P = 0.003) and female gender (P = 0.04) were independent determinants of moderate to severe LVDD. AER (P = 0.003), age (P = 0.01) and male gender (P = 0.006) were directly and independently related to LVM. Conclusion: About half of asymptomatic type 2 diabetes patients have LVDD. Of those, more than one third display moderate LVDD pattern paralleled by increases in BNP, suggesting markedly increased risk of heart failure, especially in females, whereas AER and male sex are related to LVM.
  •  
14.
  • Manouras, Aristomenis, et al. (författare)
  • Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 7, s. 29-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated. Methods: Left ventricular (LV) longitudinal systolic myocardial velocities and displacement during ejection period were quantified at the basal septal and lateral wall in 24 healthy individuals (4 women and 20 men, 34 +/- 12 years) using spectral TD, colour TD and M-mode recordings. Mean, maximal and minimal spectral TD systolic velocities and the corresponding displacement values were obtained by measurements at the outer and inner borders of the spectral velocity signal. The results were then compared with those obtained with the two other modalities used. Results: Systolic myocardial velocities derived from mean spectral TD frequencies were highly concordant with corresponding colour TD measurements (mean difference 0.10 +/- 0.54 cm/sec in septal and 0.09 +/- 0.97 cm/sec in lateral wall). Similarly, the agreement between spectral and colour TD (mean difference 0.22 +/- 0.74 mm in septal and 0.02 +/- 0.86 mm in lateral wall) as well as M-mode was good when mean spectral velocities were temporally integrated and the results did not differ statistically. Conversely, displacement values from the inner or outer border of the spectral signal differed significantly from values obtained with colour TD and M-mode (p < 0.001, in both cases). Conclusion: LV systolic myocardial measurements based on mean spectral TD frequencies are highly concordant with those provided by colour TD and M-mode. Hence, in order to maintain compatibility of the results, the use of this particular spectral TD procedure should be advocated in clinical praxis.
  •  
15.
  • Manouras, Aristomenis, et al. (författare)
  • Comparison between colour-coded and spectral tissue Doppler measurements of systolic and diastolic myocardial velocities : effect of temporal filtering and offline gain setting
  • 2009
  • Ingår i: European Journal of Echocardiography. - : Oxford University Press (OUP). - 1525-2167 .- 1532-2114. ; 10:3, s. 406-413
  • Tidskriftsartikel (refereegranskat)abstract
    • Colour tissue Doppler (TD) has been reported to underestimate the longitudinal myocardial motion velocities measured with spectral TD. This study evaluates the effect of temporal smoothing and offline gain settings on the results of velocity measurements with these two methods and the difference between them. In 57 patients, 2D data and left ventricular velocity profiles were acquired using spectral and colour TD for a subsequent offline analysis. Longitudinal myocardial velocities were measured at unsaturated, 50%-saturated and fully saturated gain, and before and after temporal smoothing using 30, 50, and 70 ms filters, respectively. Gain level and filter width altered significantly the measured velocities. Peak systolic and early diastolic velocities were significantly higher (P < 0.001) and E/E' ratio was significantly lower (P < 0.001) with spectral TD than with colour TD, although there was a good correlation between the results of both TD modalities. The differences between the methods increased at increasing filter width and gain level. Despite good correlation of the results, spectral TD produces significantly higher myocardial velocity values and lower E/E' ratio than colour TD modality. Increasing gain and temporal smoothing alter significantly the results of velocity measurements and accentuate the difference between the two TD methods.
  •  
16.
  • Manouras, Aristomenis, et al. (författare)
  • Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler : time for a reassessment?
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 7, s. 12-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Echocardiographic measurements of left ventricular (LV) myocardial displacement may produce different results depending on the choice of employed modality and subjective adjustments during data acquisition and analysis. Methods: In this study, left ventricular longitudinal systolic displacement was quantified in 57 patients (31 women and 26 men, 50 +/- 16 years) using colour (colour TD) and spectral tissue Doppler (spectral TD) before and after temporal filtering (30 to 70 milliseconds in 20-millisecond steps) and changed offline gain saturation (0%, 50% and 100%), respectively. The results were compared with those obtained with anatomic M-mode. Results: Whereas only minor differences occurred between the results of colour TD and anatomic M-mode measurements, spectral TD significantly overestimated the results obtained with both these methods. However, the limits of agreement between the results produced by all three studied methods were not clinically acceptable in any of the cases. The spectral TD displacement values increased along with increasing offline gain saturation whereas the effect of temporal filtering on colour Doppler measurements was insignificant. Conclusion: Measurements of LV myocardial longitudinal displacement employing spectral TD, colour TD or anatomic M-mode produce different results, thus discouraging interchangeable use of these modalities. Whereas the results of spectral TD measurements can be significantly altered by changing offline gain setting, the effect of temporal filtering on colour TD measurements is insignificant, a fact that increases clinical practicality of the latter method.
  •  
17.
  • Ostenfeld, Ellen, et al. (författare)
  • Comparison of different views with three-dimensional echocardiography : apical views offer superior visualization compared with parasternal and subcostal views
  • 2008
  • Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961 .- 1475-097X. ; 28:6, s. 409-416
  • Tidskriftsartikel (refereegranskat)abstract
    • Studies seeking to validate real-time three-dimensional echocardiography (3DE) with regard to cardiac function and dimensions have almost exclusively used apical views. However, it has never been examined whether apical views are preferable to parasternal or subcostal views. In the present study, we compared the feasibility of 3DE volumetric measurements of the four heart chambers in three different views. We included 40 patients planned for a routine two-dimensional transthoracic echocardiography examination (2DE). All patients were scanned with both 2DE and 3DE (Sonos 7500; Philips Medical Systems Andover, MA, USA). Parasternal, apical and subcostal views were used for 3DE. Volumes were calculated using manual tracing in 16 planes. 2DE was performed in parasternal longaxis, subcostal and apical four- and two-chamber views. Manual tracing was used for area calculations. To be judged fully traceable, 5/6 (85%) or more of the ventricular and atrial walls had to be adequately visualized in each plane. The left ventricle and left atrium were adequately visualized in the 3DE apical view in 34 (85%) and 40 (100%) patients, respectively. Visualization of the right atrium was adequate in 31 (78%) patients, whereas the right ventricle was adequately visualized in only 12 (30%) patients. The apical view of 3DE provided superior visualization of all four heart chambers compared with the parasternal and subcostal views, when applying a slight off-axis approach for both ventricles when needed. Thus, in the present study, there was no incremental value of assessment of chamber volumes in the parasternal and subcostal views.
  •  
18.
  • Ostenfeld, Ellen, et al. (författare)
  • Manual correction of semi-automatic three-dimensional echocardiography is needed for right ventricular assessment in adults; validation with cardiac magnetic resonance
  • 2012
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 10
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Three-dimensional echocardiography (3DE) and semi-automatic right ventricular delineation has been proposed as an appropriate method for right ventricle (RV) evaluation. We aimed to examine how manual correction of semi-automatic delineation influences the accuracy of 3DE for RV volumes and function in a clinical adult setting using cardiac magnetic resonance (CMR) as the reference method. We also examined the feasibility of RV visualization with 3DE. Methods: 62 non-selected patients were examined with 3DE (Sonos 7500 and iE33) and with CMR (1.5T). Endocardial RV contours of 3DE-images were semi-automatically assessed and manually corrected in all patients. End-diastolic (EDV), end-systolic (ESV) volumes, stroke volume (SV) and ejection fraction (EF) were computed. Results: 53 patients (85%) had 3DE-images feasible for examination. Correlation coefficients and Bland Altman biases between 3DE with manual correction and CMR were r = 0.78, -22 +/- 27 mL for EDV, r = 0.83, -7 +/- 16 mL for ESV, r = 0.60, -12 +/- 18 mL for SV and r = 0.60, -2 +/- 8% for EF (p < 0.001 for all r-values). Without manual correction r-values were 0.77, 0.77, 0.70 and 0.49 for EDV, ESV, SV and EF, respectively (p < 0.001 for all r-values) and biases were larger for EDV, SV and EF (-32 +/- 26 mL, -21 +/- 15 mL and -6 +/- 9%, p <= 0.01 for all) compared to manual correction. Conclusion: Manual correction of the 3DE semi-automatic RV delineation decreases the bias and is needed for acceptable clinical accuracy. 3DE is highly feasible for visualizing the RV in an adult clinical setting.
  •  
19.
  •  
20.
  • Sahlén, Anders, et al. (författare)
  • Altered ventriculo-arterial coupling during exercise in athletes releasing biomarkers after endurance running
  • 2012
  • Ingår i: European Journal of Applied Physiology. - : Springer Science and Business Media LLC. - 1439-6319 .- 1439-6327. ; 112:12, s. 4069-4079
  • Tidskriftsartikel (refereegranskat)abstract
    • Exercise can lead to release of biomarkers such as cardiac troponin T (cTnT) and N-terminal pro-brain natriuretic peptide (NT-proBNP), a poorly understood phenomenon proposed to especially occur with highintensity exercise in less trained subjects. We hypothesised that haemodynamic perturbations during exercise are larger in athletes with cTnT release, and studied athletes with detectable cTnT levels after an endurance event (HIGH; n = 16; 46 ± 9 years) against matched controls whose levels were undetectable (LOW; n = 11; 44 ± 7 years). Echocardiography was performed at rest and at peak supine bicycle exercise stress. Left ventricular (LV) end-systolic elastance (ELV a load-independent measure of LV contractility), effective arterial elastance (EA a lumped index of arterial load) and end-systolic meridional wall stress were calculated from cardiac dimensions and brachial blood pressure. Efficiency of cardiac work was judged from the ventriculo-arterial coupling ratio (EA/ELV: optimal range 0.5-1.0). While subgroups had similar values at rest, we found ventriculo-arterial mismatch during exercise in HIGH subjects (0.47 (0.39-0.58) vs. LOW: 0.73 (0.62-0.83); p<0.01] due to unopposed increase in ELV (p<0.05). In LOW subjects, a greater increase occurred in EA during exercise (+81 ± 67 % vs. HIGH: +39 ± 32 %; p = 0.02) which contributed to a maintained coupling ratio. Subjects with higher baseline NT-proBNP had greater systolic wall stress during exercise (R2 = 0.39; p<0.01) despite no correlation at rest (p = ns). In conclusion, athletes with exercise-induced biomarker release exhibit ventriculo-arterial mismatch during exercise, suggesting non-optimal cardiac work may contribute to this phenomenon.
  •  
21.
  •  
22.
  •  
23.
  • Sahlen, Anders, et al. (författare)
  • Arterial vasodilatory and ventricular diastolic reserves determine the stroke volume response to exercise in elderly female hypertensive patients
  • 2011
  • Ingår i: American Journal of Physiology. Heart and Circulatory Physiology. - : American Physiological Society. - 0363-6135 .- 1522-1539. ; 301:6, s. H2433-H2441
  • Tidskriftsartikel (refereegranskat)abstract
    • Sahlen A, Abdula G, Norman M, Manouras A, Brodin LA, Lund LH, Shahgaldi K, Winter R. Arterial vasodilatory and ventricular diastolic reserves determine the stroke volume response to exercise in elderly female hypertensive patients. Am J Physiol Heart Circ Physiol 301: H2433-H2441, 2011. First published September 16, 2011; doi:10.1152/ajpheart.00555.2011.-Elderly female hypertensives with arterial stiffening constitute a majority of patients with heart failure with preserved ejection fraction (HFpEF), a condition characterized by inability to increase cardiac stroke volume (SV) with physical exercise. As SV is determined by the interaction between the left ventricle (LV) and its load, we wished to study the role of arterial hemodynamics for exertional SV reserve in patients at high risk of HFpEF. Twenty-one elderly (67 +/- 9 yr) female hypertensive patients were studied at rest and during supine bicycle stress using echocardiography including pulsed-wave Doppler to record flow in the LV outflow tract and arterial tonometry for central arterial pressure waveforms. Arterial compliance was estimated based on an exponential relationship between pressure and volume. The ratio of aortic pressure-to-flow in early systole was used to derive characteristic impedance, which was subsequently subtracted from total resistance (mean arterial pressure/cardiac output) to yield systemic vascular resistance (SVR). It was found that patients with depressed SV reserve (NoRes; reserve <15%; n = 10) showed decreased arterial compliance during exercise, while patients with SV reserve >= 15% (Res; n = 11) showed increased compliance. Exercise produced parallel increases in LV end-diastolic volume and arterial volume in Res patients while NoRes patients exhibited a lesser decrease in SVR and a drop in effective arterial volume. Poor SV reserve in elderly female hypertensives is due to simultaneous failure of LV preload and arterial vasodilatory reserves. Abnormal arterial function contributes to a high risk of HFpEF in these patients.
  •  
24.
  •  
25.
  • Shahgaldi, Kambiz, 1978- (författare)
  • Assessment of Left Ventricular Function and Hemodynamics Using Three-dimensional Echocardiography
  • 2010
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Left ventricular (LV) volumes and ejection fraction (EF) are important predictors of cardiac morbidity and mortality. LV volumes provide valuable prognostic information which isparticularly useful in the selection of therapy or determination of the optimal time for surgery. Two-dimensional (2D) echocardiography is the most widely used non-invasive method forassessment of cardiac function, 2D echocardiography has however several limitations inmeasuring LV volumes and EF since the formulas for quantifications are based on geometricalassumptions. Three-dimensional (3D) echocardiography has been available for almost twodecades, although the use of this modality has not gained wide spread acceptance. 3D echocardiography can overcome the above mentioned limitation in LV volume and EF evaluation since it is not based on geometrical assumption. 3D echocardiography has been shownin several studies to be more accurate and reproducible with low inter- and intraobservervariability in comparison to 2D echocardiography regarding the measurements of LV volumesand EF. The overall aim of the thesis was to evaluate the feasibility and accuracy of 3D echocardiography based-methods in the clinical context. In Study I the feasibility of 3D echocardiography was investigated for determination of LV volumes and EF using parasternal, apical and subcostal approaches. The study demonstrated that the apical 3D echocardiography view offers superior visualization. Study II tested the possibility of creating flow-volume loops to differentiate patients with valvular abnormalities from normal subjects. There were significant differences in the pattern from flow-volume loops clearly separating the groups. In Study III the visual estimation, “eyeballing” of EF was evaluated with two- and tri-plane echocardiography in comparison to quantitative 3D echocardiography. The study confirmed that an experienced echocardiographer can, with a high level of agreement estimate EF both with two- and tri-plane echocardiography. Study IV exposed the high accuracy of stroke volume and cardiac output determination using a3D biplane technique by planimetrically tracing the left ventricular outflow tract and indicating that an assumption of circular left ventricular outflow tract is not reliable. In Study V, two 3D echocardiography modalities, single-beat and four-beat ECG-gated 3D echocardiography were evaluated in patients having sinus rhythm and atrial fibrillation. Thesingle-beat technique showed significantly lower inter-and intraobserver variability in LV volumes and EF measurements in patients having atrial fibrillation in comparison to four-beat ECG-gated acquisition due to absence of stitching artifact. All studies demonstrated good results suggesting 3D echocardiography to be a feasible andaccurate method in daily clinical settings.
  •  
26.
  • Shahgaldi, Kambiz, et al. (författare)
  • Direct measurement of left ventricular outflow tract area using three-dimensional echocardiography in biplane mode improves accuracy of stroke volume assessment
  • 2010
  • Ingår i: Echocardiography. - : Wiley. - 0742-2822 .- 1540-8175. ; 27:9, s. 1078-1085
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: The aim of the study was to investigate whether left ventricular stroke volume (LVSV) assessment using direct measurement of left ventricular outflow tract area (LVOTA) is superior to conventional methods for SV calculation. Methods and results: Thirty patients were included in the study (39 +/- 12 years). LVSV was assessed by multiplying LVOT velocity time integral (VTI) by LVOTA provided by direct plani-metrical measurements from real time three-dimensional echocardiography (RT3DE) in biplane mode (SV2). These measurements were compared to conventional methods using either the LVOT diameter for LVOTA multiplied with VTI (SV1) or biplane Simpson (SV3). Direct SV measurements by RT3DE were used as gold standard (SVref). There was an excellent correlation and agreement between SV determined by SV2 and 3DE (r = 0.98, mean difference 0.5 +/- 3.3 mL). However, the concordance of the traditional methods (SV1 and SV3) with 3DE was weaker (r = 0.38, mean difference -2.0 +/- 17.6 mL, r = 0.84, mean difference -7.6 +/- 8.7 mL, respectively). Furthermore, cardiac output (CO) measurements performed by the different modalities were not concordant with wide limits of agreement, except by SV2 the mean difference of CO by SV1 was -0.12 +/- 1.05 L/min, 0.03 +/- 0.20 L/min by SV2, and -0.45 +/- 0.52 L/min by SV3. Conclusions: SV and CO calculations using direct measurement of LVOT area is a feasible, accurate and reproducible method and correlates extremely well with 3DE volume measurements. SV and CO calculation by LVOTA is therefore an appealing method for LVSV assessment in clinical routine.
  •  
27.
  • Shahgaldi, Kambiz, et al. (författare)
  • Flow-volume loops derived from three-dimensional echocardiography : a novel approach to the assessment of left ventricular hemodynamics
  • 2008
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: This study explores the feasibility of non-invasive evaluation of left ventricular (LV) flow-volume dynamics using 3-dimensional (3D) echocardiography, and the capacity of such an approach to identify altered LV hemodynamic states caused by valvular abnormalities. Methods: Thirty-one patients with moderate-severe aortic (AS) and mitral (MS) stenoses (21 and 10 patients, respectively) and 10 healthy volunteers underwent 3D echocardiography with full volume acquisition using Philips Sonos 7500 equipment. The digital 3D data were post-processed using TomTec software. LV flow-volume loops were subsequently constructed for each subject by plotting instantaneous LV volume data sampled throughout the cardiac cycle vs. their first derivative representing LV flow. After correction for body surface area, an average flow-volume loop was calculated for each subject group. Results: Flow-volume loops were obtainable in all subjects, except 3 patients with AS. The flow-volume diagrams displayed clear differences in the form and position of the loops between normal individuals and the respective patient groups. In patients with AS, an "obstructive" pattern was observed, with lower flow values during early systole and larger end-systolic volume. On the other hand, patients with MS displayed a "restrictive" flow-volume pattern, with reduced diastolic filling and smaller end-diastolic volume. Conclusion: Non-invasive evaluation of LV flow-volume dynamics using 3D-echocardiographic data is technically possible and the approach has a capacity to identify certain specific types of alteration of LV flow-volume pattern caused by valvular abnormalities, thus reflecting underlying hemodynamic states specific for these abnormalities.
  •  
28.
  • Shahgaldi, Kambiz, et al. (författare)
  • Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
  • 2010
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter-and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. Methods: A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter-and intraobserver variability was analyzed. Results: SB modality showed significantly lower inter-and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p < 0.001) and EF (p < 0.05) with SB in comparison to 4B in group B. Conclusion: Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes.
  •  
29.
  • Shahgaldi, Kambiz, et al. (författare)
  • Transesophageal echocardiography measurements of aortic annulus diameter using biplane mode in patients undergoing transcatheter aortic valve implantation
  • 2013
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 11:1, s. 5-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Aortic stenosis (AS) is a relevant common valve disorder. Severe AS and symptoms and/or left ventricular dysfunction (EF<50%) have the indication for aortic valve replacement (AVR). Majority of the patients with AS are elderly often with co-morbidities and generally have high preoperative risk. Transcatheter aortic valve implantation (TAVI) is offered in this group. Four different sizes of Corevalve prosthesis are available. Correct measurement of aortic size prior to TAVI is of great important to choose the right prosthesis size to avoid among others paravalvular leak or prosthesis patient mismatch. Aim of the study is to assess the aortic annulus diameter in patients undergoing TAVI by biplane (BP) mode using transesophageal echocardiography (TEE) and compare it to two-dimensional (2D) transthoracic echocardiography (TTE) and 2DTEE using three-dimensional (3D) TEE as reference method. Methods: The study population consisted of 50 patients retrospectively (24 men and 26 women, mean age 85 +/- 8 years of age) who all had undergone echocardiography examination prior to TAVI. Results: The mean aortic annulus diameter was 20.4 +/- 2.2 mm with TTE, 22.3 +/- 2.5 mm with 2DTEE, 22.9 +/- 1.9 mm with BP-mode and 23.1 +/- 1.9 mm with 3DTEE. TTE underestimated the mean aortic annulus diameter in comparison to transesophageal imaging modalities (p<0.001). Using 3DTEE, 2% of patients were unsuitable for TAVI due to a too-small AoA (n=1). This figure was similar with BP (4%, n=2; p=1.00) but considerably larger with 2DTTE (36%, n=18; p<0.001) and 2DTEE (12%, n=6; p=0.06). There was a strong correlation between BP-mode and 3DTEE for assessment of aortic annulus diameter (r-value 0.88) with small mean difference (-0.2 +/- 0.9 mm) whereas the other modalities showed larger 95% confidence interval and modest correlation (2DTTE vs. 3DTEE, -6.3 to 0.9 mm, r=0.64 and 2DTEE vs. 3DTEE, -4.8 to 3.2 mm, r=0.61). Conclusion: A multi-dimensional method is preferred to assess aortic annulus diameter in TAVI patients since there is risk of underestimation using single plane. Biplane mode is the method of choice in view of speedy post-processing with no need for expensive dedicated software. Lastly, single plane methods lead to misclassification of patients as unsuitable for TAVI. This may be of major clinical importance.
  •  
30.
  • Shahgaldi, Kambiz, et al. (författare)
  • Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 7
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method. Methods: Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE. Results: There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively) without any significant bias (-0.5 +/- 3.7% and -0.2 +/- 2.9% respectively). Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP. Conclusion: Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant.
  •  
31.
  • Venkateshvaran, Ashwin, et al. (författare)
  • The impact of arterial load on left ventricular performance : An invasive haemodynamic study in severe mitral stenosis
  • 2015
  • Ingår i: Journal of Physiology. - : Wiley. - 0022-3751 .- 1469-7793. ; 593:8, s. 1901-1912
  • Tidskriftsartikel (refereegranskat)abstract
    • Key points: A hallmark of mitral stenosis (MS) is the markedly altered left ventricular (LV) loading. As most of the methods used to determine LV performance in MS patients are influenced by loading conditions, previous studies have shown conflicting results. The present study calculated LV elastance, which is a robust method to quantify LV function. We demonstrate that LV loading in MS patients is elevated but normalizes after valve repair and might be a result of reflex pathways. Additionally, we show that the LV in MS is less compliant than normal due to a combination of right ventricular loading and the valvular disease itself. Immediately after valve dilatation the increase in blood inflow into the LV results in even greater LV stiffness. Our findings enrich our understanding of heart function in MS patients and provide a simple reproducible way of assessing LV performance in MS. Left ventricular (LV) function in rheumatic mitral stenosis (MS) remains an issue of controversy, due to load dependency of previously employed assessment methods. We investigated LV performance in MS employing relatively load-independent indices robust to the altered loading state. We studied 106 subjects (32 ± 8 years, 72% female) with severe MS (0.8 ± 0.2 cm2) and 40 age-matched controls. MS subjects underwent simultaneous bi-ventricular catheterization and transthoracic echocardiography (TTE) before and immediately after percutaneous transvenous mitral commisurotomy (PTMC). Sphygmomanometric brachial artery pressures and TTE recordings were simultaneously acquired in controls. Single-beat LV elastance (Ees) was employed for LV contractility measurements. Effective arterial elastance (Ea) and LV diastolic stiffness were measured. MS patients demonstrated significantly elevated afterload (Ea: 3.0 ± 1.3 vs. 1.5 ± 0.3 mmHg ml-1; P < 0.001) and LV contractility (Ees: 4.1 ± 1.6 vs. 2.4 ± 0.5 mmHg ml-1; P < 0.001) as compared to controls, with higher Ea in subjects with smaller mitral valve area (≤ 0.8 cm2) and pronounced subvalvular fusion. Stroke volume (49 ± 16 to 57 ± 17 ml; P < 0.001) and indexed LV end-diastolic volume (LVEDVindex: 57 ± 16 to 64 ± 16 ml m-2; P < 0.001) increased following PTMC while Ees and Ea returned to more normal levels. Elevated LV stiffness was demonstrated at baseline and increased further following PTMC. Our findings provide evidence of elevated LV contractility, increased arterial load and increased diastolic stiffness in severe MS. Following PTMC, both LV contractility and afterload tend to normalize.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-31 av 31
Typ av publikation
tidskriftsartikel (27)
konferensbidrag (2)
annan publikation (1)
doktorsavhandling (1)
Typ av innehåll
refereegranskat (25)
övrigt vetenskapligt/konstnärligt (6)
Författare/redaktör
Shahgaldi, Kambiz (30)
Winter, Reidar (23)
Manouras, Aristomeni ... (16)
Gudmundsson, Petri (9)
Brodin, Lars-Åke (8)
Sahlén, Anders (7)
visa fler...
Willenheimer, Ronnie (7)
Dencker, Magnus (6)
Thorsson, Ola (6)
Ljunggren, Lennart (6)
Nowak, Jacek (5)
Sahlen, A (3)
Rück, Andreas (3)
Settergren, Magnus (3)
Brodin, Lars-Ake (3)
da Silva, Cristina (3)
Lund, Lars H. (2)
Ostenfeld, Ellen (2)
Norman, Mikael (2)
Bäck, Magnus (2)
Holm, Johan (2)
Bjällmark, Anna (2)
Lind, Britta (2)
Aagaard, Philip (1)
Braunschweig, Friede ... (1)
Norman, M. (1)
Lund, L (1)
Jovinge, Stefan (1)
Groop, Leif (1)
Abdula, G (1)
Magnusson, Martin (1)
Abrahamsson, Anna (1)
Haney, Michael, Doce ... (1)
Carlsson, Marcus (1)
Melander, Olle (1)
Sola, S (1)
Roijer, Anders (1)
Webb, Dominic-Luc (1)
Hellström, Per M., 1 ... (1)
Andersson, Daniel C. (1)
Lund, L. H. (1)
Venkateshvaran, Ashw ... (1)
Peolsson, Michael (1)
Brodin, Lars-Åke, Pr ... (1)
Larsson, Matilda (1)
Hage, Camilla (1)
Ståhlberg, Marcus (1)
Jacobsen, Per (1)
Söderqvist, Emil (1)
Ljung Faxén, Ulrika (1)
visa färre...
Lärosäte
Karolinska Institutet (24)
Kungliga Tekniska Högskolan (22)
Malmö universitet (9)
Lunds universitet (5)
Jönköping University (2)
Uppsala universitet (1)
Språk
Engelska (31)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (16)
Teknik (12)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy