SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Siska M.) "

Sökning: WFRF:(Siska M.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aamodt, K., et al. (författare)
  • The ALICE experiment at the CERN LHC
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:S08002
  • Forskningsöversikt (refereegranskat)abstract
    • ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries, Its overall dimensions are 16 x 16 x 26 m(3) with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008.
  •  
2.
  • Alme, J., et al. (författare)
  • The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events
  • 2010
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 622:1, s. 316-367
  • Tidskriftsartikel (refereegranskat)abstract
    • The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m(3) and is operated in a 0.5T solenoidal magnetic field parallel to its axis. In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb-Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report. (C) 2010 CERN for the benefit of the ALICE collaboration. Published by Elsevier B.V. All rights reserved.
  •  
3.
  • Gawlik-Starzyk, Aneta M., et al. (författare)
  • Availability, usage, and preferences of estradiol and progestogen preparations for puberty induction from a multicentral perspective
  • 2024
  • Ingår i: Hormone Research in Paediatrics. - : S. Karger. - 1663-2818 .- 1663-2826.
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Natural oestrogen administration as oral or transdermal 17β-estradiol is recommended for pubertal induction in girls with hypogonadism. However, suitable low-dose formulations are not consistently available globally. This questionnaire study aimed to identify the current availability of oestrogen and progesterone preparations worldwide.Methods: Endorsed by the ESPE Turner Syndrome Working Group, the questionnaire targeted paediatric endocrinologists. Questions focused on accessibility of oral/transdermal 17β-estradiol and progestogen preparations. Responses were collected through a SurveyMonkey survey disseminated via ESPE channels, direct outreach, and conferences from June 2020 to December 2022.Results: Participation included 229 healthcare professionals from 45 countries. Oral and transdermal 17β-estradiol in adult dosage was highly accessible (86.5% and 84.3%), with transdermal administration the preferred form (62.8%). Most commonly available estradiol preparations included 50 μg patches (32 countries) and 1 or 2 mg tablets (65.8% and 71.1% countries). However, 0.5 mg 17β-estradiol tablets were available in only 20% of respondents from 8 countries. Patches delivering 14 or 25 μg/day of 17β-estradiol were available in 3 and 20 countries, respectively. Oral progestogen had widespread availability (96.0%) and preference (87.0%), while transdermal usage was limited to 15.2% of respondents.Conclusion: This study highlights global challenges in accessing suitable hormone preparations for female pubertal induction. In most countries, the lowest dose of the estradiol is 50 μg for patches and 2 mg for tablets. Appropriate low-dose 17β-estradiol tablets are much less available than low-dose patches. Our survey underscores the importance of adapting guidelines to local availability, and the need for improved accessibility to address these global disparities.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy