SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Smekal David) "

Sökning: WFRF:(Smekal David)

  • Resultat 1-24 av 24
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Rubertsson, Sten, et al. (författare)
  • Mechanical chest compressions and simultanous defibrillationvs conventional cardiopulmonary resuscitationin out-of hospital cardiac arrest:the LINC randomized trial
  • 2014
  • Ingår i: Journal of the American Medical Association (JAMA). - : American Medical Association. - 0098-7484 .- 1538-3598. ; 311:1, s. 53-61
  • Tidskriftsartikel (refereegranskat)abstract
    • IMPORTANCE: A strategy using mechanical chest compressions might improve the poor outcome in out-of-hospital cardiac arrest, but such a strategy has not been tested in large clinical trials. OBJECTIVE: To determine whether administering mechanical chest compressions with defibrillation during ongoing compressions (mechanical CPR), compared with manual cardiopulmonary resuscitation (manual CPR), according to guidelines, would improve 4-hour survival. DESIGN, SETTING, AND PARTICIPANTS: Multicenter randomized clinical trial of 2589 patients with out-of-hospital cardiac arrest conducted between January 2008 and February 2013 in 4 Swedish, 1 British, and 1 Dutch ambulance services and their referring hospitals. Duration of follow-up was 6 months. INTERVENTIONS: Patients were randomized to receive either mechanical chest compressions (LUCAS Chest Compression System, Physio-Control/Jolife AB) combined with defibrillation during ongoing compressions (n = 1300) or to manual CPR according to guidelines (n = 1289). MAIN OUTCOMES AND MEASURES: Four-hour survival, with secondary end points of survival up to 6 months with good neurological outcome using the Cerebral Performance Category (CPC) score. A CPC score of 1 or 2 was classified as a good outcome. RESULTS: Four-hour survival was achieved in 307 patients (23.6%) with mechanical CPR and 305 (23.7%) with manual CPR (risk difference, -0.05%; 95% CI, -3.3% to 3.2%; P > .99). Survival with a CPC score of 1 or 2 occurred in 98 (7.5%) vs 82 (6.4%) (risk difference, 1.18%; 95% CI, -0.78% to 3.1%) at intensive care unit discharge, in 108 (8.3%) vs 100 (7.8%) (risk difference, 0.55%; 95% CI, -1.5% to 2.6%) at hospital discharge, in 105 (8.1%) vs 94 (7.3%) (risk difference, 0.78%; 95% CI, -1.3% to 2.8%) at 1 month, and in 110 (8.5%) vs 98 (7.6%) (risk difference, 0.86%; 95% CI, -1.2% to 3.0%) at 6 months with mechanical CPR and manual CPR, respectively. Among patients surviving at 6 months, 99% in the mechanical CPR group and 94% in the manual CPR group had CPC scores of 1 or 2. CONCLUSIONS AND RELEVANCE: Among adults with out-of-hospital cardiac arrest, there was no significant difference in 4-hour survival between patients treated with the mechanical CPR algorithm or those treated with guideline-adherent manual CPR. The vast majority of survivors in both groups had good neurological outcomes by 6 months. In clinical practice, mechanical CPR using the presented algorithm did not result in improved effectiveness compared with manual CPR. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00609778.
  •  
2.
  • Rubertsson, Sten, et al. (författare)
  • Per-Protocol and Pre-Defined population analysis of the LINC study
  • 2015
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 96, s. 92-99
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To perform two predefined sub-group analyses within the LINC study and evaluate if the results were supportive of the previous reported intention to treat (ITT) analysis.METHODS: Predefined subgroup analyses from the previously published LINC study were performed. The Per-Protocol population (PPP) included the randomized patients included in the ITT-population but excluding those with violated inclusion or exclusion criteria and those that did not get the actual treatment to which the patient was randomized. In the Pre-Defined population (PDP) analyses patients were also excluded if the dispatch time to ambulance arrival at the address exceeded 12min, there was a non-witnessed cardiac arrest, or if it was not possible to determine whether the arrest was witnessed or not, and those cases where LUCAS was not brought to the scene at the first instance.RESULTS: After exclusion from the 2589 patients within the ITT-population, the Per-Protocol analysis was performed in 2370 patients and the Pre-Defined analysis within 1133 patients. There was no significant difference in 4-h survival of patients between the mechanical-CPR group and the manual-CPR group in the Per-Protocol population; 279 of 1172 patients (23.8%) versus 281 of 1198 patients (23.5%) (risk difference -0.35%, 95% C.I. -3.1 to 3.8, p=0.85) or in the Pre-Defined population; 176 of 567 patients (31.0%) versus 192 of 566 patients (33.9%) (risk difference -2.88%, 95% C.I. -8.3 to 2.6, p=0.31). There was no difference in any of the second outcome variables analyzed in the Pre-Protocol or Pre-Defined populations.CONCLUSIONS: The results from these predefined sub-group analyses of the LINC study population did not show any difference in 4h survival or in secondary outcome variables between patients treated with mechanical-CPR or manual-CPR. This is consistent with the previously published ITT analysis.
  •  
3.
  • Bandert, Anna, et al. (författare)
  • Different distances between central venous catheter tips can affect antibiotic clearance during continuous renal replacement therapy
  • 2024
  • Ingår i: Intensive Care Medicine Experimental. - : Springer Nature. - 2197-425X. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The aim of this experimental study was to elucidate whether different distances between central venous catheter tips can affect drug clearance during continuous renal replacement therapy (CRRT). Central venous catheters (CVCs) are widely used in intensive care patients for drug infusion. If a patient receives CRRT, a second central dialysis catheter (CDC) is required. Where to insert CVCs is directed by guidelines, but recommendations regarding how to place multiple catheters are scarce. There are indications that a drug infused in a CVC with the tip close to the tip of the CDC, could be directly aspirated into the dialysis machine, with a risk of increased clearance. However, studies on whether clearance is affected by different CVC and CDC tip positions, when the two catheters are in the same vessel, are few.METHODS: In this model with 18 piglets, gentamicin (GM) and vancomycin (VM) were infused through a CVC during CRRT. The CVC tip was placed in different positions in relation to the CDC tip from caudal, i.e., proximal to the heart, to cranial, i.e., distal to the heart. Serum and dialysate concentrations were sampled after approximately 30 min of CRRT at four different positions: when the CVC tip was 2 cm caudally (+ 2), at the same level (0), and at 2 (- 2) and 4 (- 4) cm cranially of the tip of the CDC. Clearance was calculated. A mixed linear model was performed, and level of significance was set to p < 0.05.RESULTS: Clearance of GM had median values at + 2 cm, 0 cm, - 2 cm and - 4 cm of 17.3 (5.2), 18.6 (7.4), 20.0 (16.2) and 26.2 (12.2) ml/min, respectively (p = 0.04). Clearance of VM had median values at + 2 cm, 0 cm, - 2 cm and - 4 cm of 16.2 (4.5), 14.7 (4.9), 19.0 (10.2) and 21.2 (11.4) ml/min, respectively (p = 0.02).CONCLUSIONS: The distance between CVC and CDC tips can affect drug clearance during CRRT. A cranial versus a caudal tip position of the CVC in relation to the tip of the CDC led to the highest clearance.
  •  
4.
  • Bandert, Anna, et al. (författare)
  • In an endotoxaemic model, antibiotic clearance can be affected by different central venous catheter positions, during renal replacement therapy
  • 2023
  • Ingår i: Intensive Care Medicine Experimental. - : Springer Nature. - 2197-425X. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In intensive care, different central venous catheters (CVC) are often used for infusion of drugs. If a patient is treated with continuous renal replacement therapy (CRRT) a second catheter, a central venous dialysis catheter (CVDC), is needed. Placing the catheters close together might pose a risk that a drug infused in a CVC could be directly aspirated into a CRRT machine and cleared from the blood without giving the effect intended. The purpose of this study was to elucidate if drug clearance is affected by different catheter placement, during CRRT. In this endotoxaemic animal model, an infusion of antibiotics was administered in a CVC placed in the external jugular vein (EJV). Antibiotic clearance was compared, whether CRRT was through a CVDC placed in the same EJV, or in a femoral vein (FV). To reach a target mean arterial pressure (MAP), noradrenaline was infused through the CVC and the dose was compared between the CDVDs.RESULTS: The main finding in this study was that clearance of antibiotics was higher when both catheter tips were in the EJV, close together, compared to in different vessels, during CRRT. The clearance of gentamicin was 21.0 ± 7.3 vs 15.5 ± 4.2 mL/min (p 0.006) and vancomycin 19.3 ± 4.9 vs 15.8 ± 7.1 mL/min (p 0.021). The noradrenaline dose to maintain a target MAP also showed greater variance with both catheters in the EJV, compared to when catheters were placed in different vessels.CONCLUSION: The results in this study indicate that close placement of central venous catheter tips could lead to unreliable drug concentration, due to direct aspiration, during CRRT.
  •  
5.
  • Frithiof, Robert, et al. (författare)
  • Central Venous Line and Dialysis Catheter Position Affects Drug Clearance during Continuous Renal Replacement Therapy in an Animal Model.
  • 2019
  • Ingår i: ASAIO journal (1992). - 1058-2916 .- 1538-943X. ; 65:4, s. 408-413
  • Tidskriftsartikel (refereegranskat)abstract
    • In intensive care, drugs are commonly administered through central venous catheters (CVC). These catheters and central venous dialysis catheters (CVDC) are often placed in the same vessel for practical reasons. The aim of this experimental study was to investigate if the position of CVC and CVDC influences the elimination of infused drugs, during continuous renal replacement therapy (CRRT). In a randomized, cross-over model, anesthetized piglets received both a CVC and a CVDC in a jugular vein. Another CVDC was placed in a femoral vein for comparison. After baseline measurements, CRRT was performed in either of the CVDC, each CRRT-period separated by another baseline period. Hypotension was induced by peripherally given sodium nitroprusside. In the CVC, both gentamicin and noradrenaline were administered. Noradrenaline was titrated to reach a target blood pressure. When CRRT was performed using the CVDC in the same vessel as the drugs were infused, the plasma concentration of gentamicin was reduced compared with when the infusion and CVDC were in different vessels (5.66 [standard deviation (SD) ± 1.23] vs. 7.76 [SD ± 2.30] mg/L [p = 0.02]). The noradrenaline infusion rate needed to reach the target blood pressure was more than doubled (0.32 [SD ± 0.16] vs. 0.15 [SD ± 0.08] µg/kg/min [p = 0.006]). This experimental study indicates that the removal of drugs is increased if infusion is in close vicinity of the CVDC, during CRRT.
  •  
6.
  • Lagedal, Rickard, et al. (författare)
  • Coronary angiographic findings after cardiac arrest in relation to ECG and comorbidity
  • 2020
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 146, s. 213-219
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: The relations between specific ECG patterns and coronary angiographic findings in cardiac arrest patients with different comorbidities are not properly assessed. More evidence is needed to identify patients with the highest risk for acute coronary artery disease as a cause of the cardiac arrest. This study aims to describe the coronary artery findings after cardiac arrest in relation to ECG and comorbidity.Method: A retrospective study of out-of-hospital cardiac arrest patients, with coronary angiography performed within 28 days. ECG on admission, comorbidity, PCI attempts and angiographic findings are described. Data were retrieved from national registries in Sweden.Results: Among 1133 patients with available ECG and angiography information the mean age was 64 years. The rate of shockable rhythm was 79 degrees 0. The total incidence of any significant stenosis in cardiac arrest patients without ST-elevation who underwent coronary angiography within 28 days was 71 degrees 0. The incidence of any stenosis in patients with normal ECG was 62.1 degrees 0 and in patients with LBBB, 59.3 degrees 0. In patients with ST-depression or RBBB, PCI attempts were made in 47.1 degrees 0 and 42.4 degrees 0 respectively, compared with 33.3 degrees 0 in patients with normal ECG. Among patients without ST-elevation, those with diabetes mellitus and those with initial shockable rhythm respectively, 84.8 degrees 0 and 71.5 had at least one significant stenosis.Conclusion: Our study suggests, that evaluation of ECG patterns and comorbidities in out-of-hospital cardiac arrest patients without ST-segment elevation may be important to identify those with a high risk of coronary artery lesions that could benefit from early revascularization.
  •  
7.
  • Lagedal, Rickard, 1981- (författare)
  • Coronary angiography after out-of-hospital cardiac arrest
  • 2020
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Out-of-hospital cardiac arrest (OHCA) is a common cause of death with a survival rate of 10% in Sweden. The chance of survival depends on rapid recognition, high quality cardiopulmonary resuscitation and post-resuscitation care including searching and treating the cause of the arrest. Ischaemic cardiac disease including acute coronary artery occlusions is the most common cause of OHCA. Acute coronary artery lesions can be diagnosed and treated with coronary angiography and subsequent PCI. This thesis analyses various aspects of coronary angiography after OHCA. Paper I+II describes the rational, protocol and the results from the pilot phase (n=117) of a randomized multicentre clinical trial. We compared a strategy of immediate coronary angiography in patients successfully resuscitated after OHCA with a strategy without immediate coronary angiography. We did not reach the stipulated time of 120 minutes from first medical contact to angiography, but our study strategy was feasible. No major unexpected safety issues were reported. The main phase of the study could therefore be started with only minor changes from the pilot phase protocol.  In a registry study of 1133 patients (Paper III) coronary angiographic findings were compared with ECG and comorbidities in unconscious patients after OHCA. In patients without ST-elevation, the rate of PCI attempts was higher in patients with ST-depression (47%) and in patients with ECG classified as “other findings” (45%) compared to patients with normal ECG (33%), OR 1.78 (CI 1.13-2.82) and OR 1.65 (CI 1.04-2.61), respectively. When analysing patients without ST-elevation, no difference in PCI rates were found between the comorbidity groups and neither between patients with shockable compared to non-shockable initial ECG rhythm. Paper IV is a registry study (n=3906) analysing the impact of patient income on the probability to receive early coronary angiography after OHCA. When dividing patients into income quarters and adjusting for confounders, increasing income was associated with higher rates of early coronary angiography. Thirty-six percent of patients in the highest income quarter received early angiography compared to fifteen percent in the lowest income quarter, OR 1.64 (1.27-2.11). Adding potential mediators to explain this finding gradually decreased the difference, and the main explanatory factor for this difference was that higher income is associated with higher rates of shockable ECG rhythm. 30-day survival was also higher in the highest income quarter compared to the lowest income group in the fully adjusted analysis, OR 1.51 (CI 1.22-1.89).
  •  
8.
  • Lagedal, Rickard, et al. (författare)
  • Income is associated with the probability to receive early coronary angiography after out-of-hospital cardiac arrest
  • 2020
  • Ingår i: Resuscitation. - : Elsevier. - 0300-9572 .- 1873-1570. ; 156, s. 35-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Low socioeconomic status has been associated with worse outcome after cardiac arrest. This study aims to investigate if patients income influences the probability to receive early coronary angiography in out-of-hospital cardiac arrest (OHCA) patients.Methods: In this nationwide retrospective observational study, 3906 OHCA patients admitted alive and registered in the Swedish Registry for Cardiopulmonary Resuscitation were included. Individual data on income and educational level, prehospital parameters, coronary angiography results and comorbidity were linked from SWEDEHEART and other national registers.Results: Patients were divided into quarters depending on their income level. In the unadjusted model there was a strong correlation between income level and rate of early coronary angiography where 35.5% of patients in the highest income quarters received early angiography compared to 15.4% in the lowest income quarters. When adjusting for educational level, sex, age, comorbidity and hospital type, there were still higher chance of receiving early coronary angiography with increasing income, OR 1.31 (CI 1.01-1.68) and 1.67 (CI 1.29-2.16) for the two highest income quarters respectively compared to the lowest income quarter. When adding potential mediators to the model (first recorded ECG rhythm by the EMS, location, response time, bystander cardiopulmonary resuscitation and if the arrest was witnessed) no difference in early angiography related to income level where found. The main mediator was first recorded ECG rhythm.Conclusion: Income level is associated with the probability to undergo early coronary angiography in OHCA patients. This association seems to be mediated by the initial ECG rhythm.
  •  
9.
  • Larsson, Anders, et al. (författare)
  • Rapid testing of red blood cells, white blood cells and platelets in intensive care patients using the HemoScreen™ point-of-care analyzer
  • 2019
  • Ingår i: Platelets. - : Informa UK Limited. - 0953-7104 .- 1369-1635. ; 30:8, s. 1013-1016
  • Tidskriftsartikel (refereegranskat)abstract
    • Acute major bleeding is a condition that can be encountered in critically ill patients and may require rapid transfusions. To evaluate the need for packed red blood cells (RBCs) and platelets (PLTs), it is important to have rapid test results for RBC/hemoglobin and PLTs. Recently, PixCell Medical (Yokneam Ilit, Israel) introduced the HemoScreen™, an automated hematology analyzer. It is a point-of-care device that uses single sample cuvettes and image analysis of RBCs, PLTs and white blood cells (WBCs), performing a five-part differential count. The HemoScreen™ is the first portable differential count instrument that uses image analysis. We compared the RBC, PLT, and WBC test results of the HemoScreen™ with the Sysmex XN device. In the study we analyzed 104 samples from the cardiothoracic, neuro and general intensive care units. The HemoScreen™ technique showed good precision, with total coefficient of variation of 1-2% for RBCs and 3-5% for PLTs. Deming correlations between the HemoScreen and the Sysmex XN instrument analyzer: (WBCHemoScreen™ = 1.061* WBCSysmex - 0.644; r = 0.995), RBC (RBCHemoScreen™ = 0.998* RBCSysmex + 0.049; r = 0.993) for WBC and (PlateletsHemoScreen™ = 1.087* PlateletsSysmex - 14.80; r = 0.994) for PLT. The HemoScreen™ device provided rapid and accurate test results to evaluate the need for RBC and PLT transfusion. This new technology is promising given that it allows the analysis of WBCs, RBCs, and PLTs further out in the healthcare organization compared with laboratory infrastructure based on traditional cell counters.
  •  
10.
  • Lindgren, Erik, et al. (författare)
  • Gender differences in utilization of coronary angiography and angiographic findings after out-of-hospital cardiac arrest : A registry study
  • 2019
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 143, s. 189-195
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: We investigated the impact of gender in performance and findings of early coronary angiography (CAG) and percutaneous coronary intervention (PCI), comorbidity and outcome in a large population of out-of-hospital cardiac arrest (OHCA) patients with an initially shockable rhythm.Methods: Retrospective cohort study. Data retrieved 2008-2013 from the Swedish Register for Cardio-Pulmonary Resuscitation, Swedeheart Registry and National Patient Register.Results: We identified 1498 patients of whom 78% were men. Men and women had the same pathology on the first registered electrocardiogram (ECG): 30% vs. 29% had ST-elevation and 10% vs. 9% had left bundle branch block (LBBB) (P=0.97). Proportions of performed CAG did not differ between genders. Among patients without ST-elevation/LBBB men more often had at least one significant stenosis, 78% vs. 54% (P= 0.001), more multi-vessel disease (P= 0.01), had normal coronary angiography less often, 22% vs. 46% and PCI more often, 59% vs. 42% (P= 0.03). Among patients without STelevation/LBBB on the initial ECG, more men had previously known ischaemic heart disease, 27% vs. 19% (P=0.02) and a presumed cardiac origin of the cardiac arrest, 86% vs. 72% (P< 0.001). Multivariable analysis showed no association between gender and evaluation by early CAG. In men and women, 1-year survival was 56% vs. 50% (P= 0.22) in patients with ST-elevation/LBBB and 48% vs. 51% (P= 0.50) in patients without.Conclusion: Despite no gender differences in ECG findings indicating an early CAG, men had more severe coronary artery disease while women more frequently had normal coronary angiography. However, this did not influence 1-year survival.
  •  
11.
  • Lipcsey, Miklós, et al. (författare)
  • The time course of calprotectin liberation from human neutrophil granulocytes after Escherichia coli and endotoxin challenge
  • 2019
  • Ingår i: Innate Immunity. - : SAGE Publications. - 1753-4259 .- 1753-4267. ; 25:6, s. 369-373
  • Tidskriftsartikel (refereegranskat)abstract
    • Plasma calprotectin has previously been reported as a biomarker for sepsis. The aim of the present study was to elucidate the kinetics of calprotectin release from neutrophils exposed to Escherichia coli and endotoxin. Whole blood samples were exposed to E. coli bacteria or endotoxin in vitro. Blood samples were collected after 0, 1, 2, 3 and 4 h and plasma calprotectin was analysed by particle enhanced turbidimetric immunoassay while TNF-α, IL-6, neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule-1 (KIM-1) were analyzed by ELISA. When neutrophils were exposed to either E. coli or endotoxin, calprotectin levels began to increase within a couple of hours after the challenge. Calprotectin increases early in response to bacterial challenge. Given the logistic advantages of the calprotectin analysis, this may be of interest for early diagnosis of bacterial infections.
  •  
12.
  • Mälberg, Johan, et al. (författare)
  • Continuous chest compressions are associated with higher peak inspiratory pressures when compared to 30:2 in an experimental cardiac arrest model
  • 2023
  • Ingår i: Intensive Care Medicine Experimental. - : Springer. - 2197-425X. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Ventilation during cardiopulmonary resuscitation (CPR) has long been a part of the standard treatment during cardiac arrests. Ventilation is usually given either during continuous chest compressions (CCC) or during a short pause after every 30 chest compressions (30:2). There is limited knowledge of how ventilation is delivered if it effects the hemodynamics and if it plays a role in the occurrence of lung injuries. The aim of this study was to compare ventilation parameters, hemodynamics, blood gases and lung injuries during experimental CPR given with CCC and 30:2 in a porcine model.METHODS: Sixteen pigs weighing approximately 33 kg were randomized to either receive CPR with CCC or 30:2. Ventricular fibrillation was induced by passing an electrical current through the heart. CPR was started after 3 min and given for 20 min. Chest compressions were provided mechanically with a chest compression device and ventilations were delivered manually with a self-inflating bag and 12 l/min of oxygen. During the experiment, ventilation parameters and hemodynamics were sampled continuously, and arterial blood gases were taken every five minutes. After euthanasia and cessation of CPR, the lungs and heart were removed in block and visually examined followed by sampling of lung tissue which were examined using microscopy.RESULTS: In the CCC group and the 30:2 group, peak inspiratory pressure (PIP) was 58.6 and 35.1 cmH2O (p < 0.001), minute volume (MV) 2189.6 and 1267.1 ml (p < 0.001), peak expired carbon dioxide (PECO2) 28.6 and 39.4 mmHg (p = 0.020), partial pressure of carbon dioxide (PaCO2) 50.2 and 61.1 mmHg (p = 0.013) and pH 7.3 and 7.2 (p = 0.029), respectively. Central venous pressure (CVP) decreased more over time in the 30:2 group (p = 0.023). All lungs were injured, but there were no differences between the groups.CONCLUSIONS: Ventilation during CCC resulted in a higher PIP, MV and pH and lower PECO2 and PaCO2, showing that ventilation mode during CPR can affect ventilation parameters and blood gases.
  •  
13.
  • Mälberg, Johan, et al. (författare)
  • Physiological respiratory parameters in pre-hospital patients with suspected COVID-19 : A prospective cohort study
  • 2021
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 16:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The COVID-19 pandemic has presented emergency medical services (EMS) worldwide with the difficult task of identifying patients with COVID-19 and predicting the severity of their illness. The aim of this study was to investigate whether physiological respiratory parameters in pre-hospital patients with COVID-19 differed from those without COVID-19 and if they could be used to aid EMS personnel in the prediction of illness severity. Methods Patients with suspected COVID-19 were included by EMS personnel in Uppsala, Sweden. A portable respiratory monitor based on pneumotachography was used to sample the included patient's physiological respiratory parameters. A questionnaire with information about present symptoms and background data was completed. COVID-19 diagnoses and hospital admissions were gathered from the electronic medical record system. The physiological respiratory parameters of patients with and without COVID-19 were then analyzed using descriptive statistical analysis and logistic regression. Results Between May 2020 and January 2021, 95 patients were included, and their physiological respiratory parameters analyzed. Of these patients, 53 had COVID-19. Using adjusted logistic regression, the odds of having COVID-19 increased with respiratory rate (95% CI 1.000-1.118), tidal volume (95% CI 0.996-0.999) and negative inspiratory pressure (95% CI 1.017-1.152). Patients admitted to hospital had higher respiratory rates (p<0.001) and lower tidal volume (p = 0.010) compared to the patients who were not admitted. Using adjusted logistic regression, the odds of hospital admission increased with respiratory rate (95% CI 1.081-1.324), rapid shallow breathing index (95% CI 1.006-1.040) and dead space percentage of tidal volume (95% CI 1.027-1.159). Conclusion Patients taking smaller, faster breaths with less pressure had higher odds of having COVID-19 in this study. Smaller, faster breaths and higher dead space percentage also increased the odds of hospital admission. Physiological respiratory parameters could be a useful tool in detecting COVID-19 and predicting hospital admissions, although more research is needed.
  •  
14.
  • Mälberg, Johan, et al. (författare)
  • Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
  • 2022
  • Ingår i: Resuscitation Plus. - : Elsevier. - 2666-5204. ; 12
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: The presented study aimed to investigate whether a mechanical chest compression piston device with a suction cup assisting chest recoil could impact the hemodynamic status when compared to a bare piston during cardiopulmonary resuscitation.Methods: 16 piglets were anesthetized and randomized into 2 groups. After 3 minutes of induced ventricular fibrillation, a LUCAS 3 device was used to perform chest compressions, in one group a suction cup was mounted on the device's piston, while in the other group, compressions were per -formed by the bare piston. The device was used in 30:2 mode and the animals were manually ventilated. Endpoints of the study were: end tidal carbon dioxide, coronary and cerebral perfusion pressures, and brain oxygenation (measured using near infrared spectroscopy). At the end of the protocol, the animals that got a return to spontaneous circulation were observed for 60 minutes, then euthanized.Results: No difference was found in end tidal carbon dioxide or tidal volumes. Coronary perfusion pressure and cerebral oxygenation were higher in the Suction cup group over the entire experiment time, while cerebral perfusion pressure was higher only in the last 5 minutes of CPR. A passive tidal volume (air going in and out the airways during compressions) was detected and found correlated to end tidal carbon dioxide.Conclusions: The use of a suction cup on a piston-based chest compression device did not increase end tidal carbon dioxide, but it was associated to a higher coronary perfusion pressure.
  •  
15.
  •  
16.
  •  
17.
  • Rubertsson, Sten, et al. (författare)
  • The Study Protocol for the LINC (LUCAS in Cardiac Arrest) Study : a study comparing conventional adult out-of-hospital cardiopulmonary resuscitation with a concept with mechanical chest compressions and simultaneous defibrillation
  • 2013
  • Ingår i: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine. - : BioMed Central Ltd.. - 1757-7241. ; 21:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The LUCAS™ device delivers mechanical chest compressions that have been shown in experimental studies to improve perfusion pressures to the brain and heart as well as augmenting cerebral blood flow and end tidal CO2, compared with results from standard manual cardiopulmonary resuscitation (CPR). Two randomised pilot studies in out-of-hospital cardiac arrest patients have not shown improved outcome when compared with manual CPR. There remains evidence from small case series that the device can be potentially beneficial compared with manual chest compressions in specific situations. This multicentre study is designed to evaluate the efficacy and safety of mechanical chest compressions with the LUCAS™ device whilst allowing defibrillation during on-going CPR, and comparing the results with those of conventional resuscitation. Methods/design This article describes the design and protocol of the LINC-study which is a randomised controlled multicentre study of 2500 out-of-hospital cardiac arrest patients. The study has been registered at ClinicalTrials.gov (http://clinicaltrials.gov/ct2/show/NCT00609778?term=LINC&rank=1 webcite). Results Primary endpoint is four-hour survival after successful restoration of spontaneous circulation. The safety aspect is being evaluated by post mortem examinations in 300 patients that may reflect injuries from CPR. Conclusion This large multicentre study will contribute to the evaluation of mechanical chest compression in CPR and specifically to the efficacy and safety of the LUCAS™ device when used in association with defibrillation during on-going CPR.
  •  
18.
  • Smekal, David, et al. (författare)
  • A pilot study of mechanical chest compressions with the LUCAS (TM) device in cardiopulmonary resuscitation
  • 2011
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 82:6, s. 702-706
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: The LUCASTM device has been shown to improve organ perfusion during cardiac arrest in experimental studies. In this pilot study the aim was to compare short-term survival between cardiopulmonary resuscitation (CPR) performed with mechanical chest compressions using the LUCASTM device and CPR performed with manual chest compressions. The intention was to use the results for power calculation in a larger randomised multicentre trial. Methods: In a prospective pilot study, from February 1, 2005, to April 1, 2007, 149 patients with out-of hospital cardiac arrest in two Swedish cities were randomised to mechanical chest compressions or standard CPR with manual chest compressions. Results: After exclusion, the LUCAS and the manual groups contained 75 and 73 patients, respectively. In the LUCAS and manual groups, spontaneous circulation with a palpable pulse returned in 30 and 23 patients (p = 0.30), spontaneous circulation with blood pressure above 80/50 mmHg remained for at least 5 min in 23 and 19 patients (p = 0.59), the number of patients hospitalised alive >4 h were 18 and 15 (p = 0.69), and the number discharged, alive 6 and 7 (p = 0.78), respectively. Conclusions: In this pilot study of out-of-hospital cardiac arrest patients we found no difference in early survival between CPR performed with mechanical chest compression with the LUCASTM device and CPR with manual chest compressions. Data have been used for power calculation in a forthcoming multicentre trial.
  •  
19.
  • Smekal, David, et al. (författare)
  • Comparison of computed tomography and autopsy in detection of injuries after unsuccessful cardiopulmonary resuscitation
  • 2013
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 84:3, s. 357-360
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM:Computed tomography (CT) has been suggested as an aid or even a replacement for autopsy. The aim of this trial was to study the conformity of the two methods in finding injuries in non-surviving patients after unsuccessful cardiopulmonary resuscitation.METHODS:In this prospective study, 31 patients were submitted to a CT prior to autopsy after unsuccessful resuscitation attempts. Pathological findings were noted by both the radiologist and the pathologists in a specified protocol. The pathologists and radiologist were blinded from each other's results.RESULTS: CT and autopsy revealed rib fractures in 22 and 24 patients respectively (kappa=0.83). In 8 patients, CT revealed more rib fractures than autopsy; and in 12 patients, autopsy revealed more rib fractures than CT. In 7 patients, neither method showed any rib fractures. The mean difference between the two methods in detecting rib fractures was 0.16 (S.D.: ±3.174, limits of agreement: -6.19 to 6.51). The kappa value for sternal fractures was 0.49. A total of 260 pathological findings were noted by CT and 244 by autopsy. The average patient showed a median of 9 injuries (every fracture counted as one injury), independent of the method used in detecting the injuries.CONCLUSIONS:There was a strong concordance between the two methods in finding rib fractures but not sternal fractures and these results support the concept of CT as a valuable complement to autopsy in detecting rib fractures after unsuccessful cardiopulmonary resuscitation but not as a replacement. Other injuries did not show the same concordance.
  •  
20.
  • Smekal, David, 1971-, et al. (författare)
  • CPR related injuries after manual or mechanical chest compressions with the LUCAS™ device : A multicentre study in victims after unsuccessful resuscitation
  • 2014
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 85:12, s. 1708-1712
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: The reported incidence of injuries due to cardiopulmonary resuscitation using manual chest compressions (manual CPR) varies greatly. Our aim was to elucidate the incidence of CPR-related injuries by manual chest compressions compared to mechanical chest compressions with the LUCAS device (mechanical CPR) in non-survivors after out-of-hospital cardiac arrest.METHODS: In this prospective multicentre trial, including 222 patients (83 manual CPR/139 mechanical CPR), autopsies were conducted after unsuccessful CPR and the results were evaluated according to a specified protocol.RESULTS: Among the patients included, 75.9% in the manual CPR group and 91.4% in the mechanical CPR group (p=0.002) displayed CPR-related injuries. Sternal fractures were present in 54.2% of the patients in the manual CPR group and in 58.3% in the mechanical CPR group (p=0.56). Of the patients in the manual CPR group, there were 64.6% with at least one rib fracture versus 78.8% in the mechanical CPR group (p=0.02). The median number of rib fractures among patients with rib fractures was 7 in the manual CPR group and 6 in the mechanical CPR group. No CPR-related injury was considered to be the cause of death.CONCLUSION: In patients with unsuccessful CPR after out-of-hospital cardiac arrest, rib fractures were more frequent after mechanical CPR but there was no difference in the incidence of sternal fractures. No injury was deemed fatal by the pathologist.
  •  
21.
  • Smekal, David, et al. (författare)
  • No difference in autopsy detected injuries in cardiac arrest patients treated with manual chest compressions compared with mechanical compressions with the LUCAS device--a pilot study
  • 2009
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 80:10, s. 1104-1107
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: To compare the variety and incidence of internal injuries after manual and mechanical chest compressions during CPR. METHODS: In a prospective pilot study conducted in two Swedish cities, 85 patients underwent autopsy after unsuccessful resuscitation attempts with manual or mechanical chest compressions, the latter with the LUCAS device. Autopsy was performed and the results were evaluated according to a specified protocol. RESULTS: No injuries were found in 26/47 patients in the manual group and in 16/38 patients in the LUCAS group (p=0.28). Sternal fracture was present in 10/47 in the manual group and 11/38 in the LUCAS group (p=0.46), and there were multiple rib fractures (> or =3 fractures) in 13/47 in the manual group and in 17/38 in the LUCAS group (p=0.12). Bleeding in the ventral mediastinum was noted in 2/47 and 3/38 in the manual and LUCAS groups respectively (p=0.65), retrosternal bleeding in 1/47 and 3/38 (p=0.32), epicardial bleeding in 1/47 and 4/38 (p=0.17), and haemopericardium in 4/47 and 3/38 (p=1.0) respectively. One patient in the LUCAS group had a small rift in the liver and one patient in the manual group had a rift in the spleen. These injuries were not considered to have contributed to the patient's death. CONCLUSION: Mechanical chest compressions with the LUCAS device appear to be associated with the same variety and incidence of injuries as manual chest compressions.
  •  
22.
  • Smekal, David, 1971- (författare)
  • Safety with Mechanical Chest Compressions in CPR : Clinical studies with the LUCAS™ device
  • 2013
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Chest compressions in cardiopulmonary resuscitation are of utmost importance although not without a risk. Many injuries are described but the incidence of these is hard to define due to methodological differences. It is strenuous to perform chest compressions and therefore mechanical chest compressions have been looked upon with interest. This thesis presents new insights on the panorama and incidence of injuries in modern CPR and a comparison of safety and efficacy between manual chest compressions and mechanical chest compressions with the LUCAS™ device.We also evaluated if computed tomography could be an aid in the detection of these injuries.Two pilot trials were conducted and one presented no difference in early survival with 26% and 31% having return of spontaneous circulation when comparing manual chest compressions with the LUCAS device in out-of-hospital cardiac arrest. The other revealed no difference in autopsy-detected injuries. A third multicentre autopsy trial revealed that in patients treated with manual chest compressions 78.3% had at least one injury and 63.9% had at least one rib fracture. The corresponding numbers for patients treated with the LUCAS device was 92.8% (p = 0.002) and 77.7% (p=0.022). Sternal fractures occurred in 54.2% and in 58.3% of the cases treated with manual chest compressions and the LUCAS device respectively (p = 0.556). The median number of rib fractures was 7 in the group receiving manual chest compressions and 6 in the group receiving chest compressions with the LUCAS device. In 31 cases a computed tomography was conducted prior to autopsy and we found a very strong correlation in the discrimination of patients with or without rib fractures (kappa=0.83). Mean difference between the two methods in detecting rib fractures was 0.16. The detection of other injuries did not have a strong correlation. In conclusion there is no difference in early survival between the two methods and mechanical chest compressions adds 14-15% more patients with rib fractures but the amount of rib fractures, sternal fractures and other injuries is equal. CT can aid but not replace autopsies in the detection of these injuries.
  •  
23.
  • Spangler, Douglas, et al. (författare)
  • A validation of machine learning-based risk scores in the prehospital setting
  • 2019
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 14:12
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The triage of patients in prehospital care is a difficult task, and improved risk assessment tools are needed both at the dispatch center and on the ambulance to differentiate between low- and high-risk patients. This study validates a machine learning-based approach to generating risk scores based on hospital outcomes using routinely collected prehospital data.METHODS: Dispatch, ambulance, and hospital data were collected in one Swedish region from 2016-2017. Dispatch center and ambulance records were used to develop gradient boosting models predicting hospital admission, critical care (defined as admission to an intensive care unit or in-hospital mortality), and two-day mortality. Composite risk scores were generated based on the models and compared to National Early Warning Scores (NEWS) and actual dispatched priorities in a prospectively gathered dataset from 2018.RESULTS: A total of 38203 patients were included from 2016-2018. Concordance indexes (or areas under the receiver operating characteristics curve) for dispatched priorities ranged from 0.51-0.66, while those for NEWS ranged from 0.66-0.85. Concordance ranged from 0.70-0.79 for risk scores based only on dispatch data, and 0.79-0.89 for risk scores including ambulance data. Dispatch data-based risk scores consistently outperformed dispatched priorities in predicting hospital outcomes, while models including ambulance data also consistently outperformed NEWS. Model performance in the prospective test dataset was similar to that found using cross-validation, and calibration was comparable to that of NEWS.CONCLUSIONS: Machine learning-based risk scores outperformed a widely-used rule-based triage algorithm and human prioritization decisions in predicting hospital outcomes. Performance was robust in a prospectively gathered dataset, and scores demonstrated adequate calibration. Future research should explore the robustness of these methods when applied to other settings, establish appropriate outcome measures for use in determining the need for prehospital care, and investigate the clinical impact of interventions based on these methods.
  •  
24.
  • Spangler, Douglas, et al. (författare)
  • Prehospital identification of Covid-19 : an observational study
  • 2021
  • Ingår i: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine. - : Springer Nature. - 1757-7241. ; 29:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The novel coronavirus disease 2019 (Covid-19) pandemic has affected prehospital care systems across the world, but the prehospital presentation of affected patients and the extent to which prehospital care providers are able to identify them is not well characterized. In this study, we describe the presentation of Covid-19 patients in a Swedish prehospital care system, and asses the predictive value of Covid-19 suspicion as documented by dispatch and ambulance nurses.METHODS: Data for all patients with dispatch, ambulance, and hospital records between January 1-August 31, 2020 were extracted. A descriptive statistical analysis of patients with and without hospital-confirmed Covid-19 was performed. In a subset of records beginning from April 14, we assessed the sensitivity and specificity of documented Covid-19 suspicion in dispatch and ambulance patient care records.RESULTS: A total of 11,894 prehospital records were included, of which 481 had a primary hospital diagnosis code related to-, or positive test results for Covid-19. Covid-19-positive patients had considerably worse outcomes than patients with negative test results, with 30-day mortality rates of 24% vs 11%, but lower levels of prehospital acuity (e.g. emergent transport rates of 14% vs 22%). About half (46%) of Covid-19-positive patients presented to dispatchers with primary complaints typically associated with Covid-19. Six thousand seven hundred seventy-six records were included in the assessment of predictive value. Sensitivity was 76% (95% CI 71-80) and 82% (78-86) for dispatch and ambulance suspicion respectively, while specificities were 86% (85-87) and 78% (77-79).CONCLUSIONS: While prehospital suspicion was strongly indicative of hospital-confirmed Covid-19, based on the sensitivity identified in this study, prehospital suspicion should not be relied upon as a single factor to rule out the need for isolation precautions. The data provided may be used to develop improved guidelines for identifying Covid-19 patients in the prehospital setting.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-24 av 24

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy