SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sobh Mohamed) "

Sökning: WFRF:(Sobh Mohamed)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Cheng, Peng, et al. (författare)
  • Contactless Rotor RPM Measurement Using Laser Mouse Sensors
  • 2012
  • Ingår i: IEEE Transactions on Instrumentation and Measurement. - 0018-9456 .- 1557-9662. ; 61:3, s. 740-748
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents an experimental study using laser mouse sensors for the contactless revolutions per minute (RPM) measurement of a rotating shaft. The sensor performance characterization experiment is firstly conducted under different parameter setups. After the optimal parameter value has been found, the rotor RPM experiment is then conducted with a speed sweep from 500 to 3800 rpm, and data are gathered at 30 different speeds and processed using two different methods to convert the sensor readings into the RPM of the rotating shaft; the results are then displayed. The performance differences between the two methods are compared, and the observation is that both the linearity and the signal-to-noise ratio of the frequency correlation method are several times better than those for the amplitude correlation method. The conclusion summarizes the experimental results and the advantage associated with this new RPM sensing method and provides the motivation for its potential applications and its future works.
  •  
2.
  • Mustafa, Mohamed Sobh, et al. (författare)
  • Stator-Free Low Angular Speed Sensor Based on a MEMS Gyroscope
  • 2014
  • Ingår i: IEEE Transactions on Instrumentation and Measurement. - 0018-9456 .- 1557-9662. ; 63:11, s. 2591-2598
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper demonstrates the implementation and tests the performance of a low angular speed sensor for rotary machinery based on a microelectromechanical system gyroscope. First, an experimental test setup is presented that features a top-of-the-line optical absolute angle encoder as a reference for characterizing the proposed sensor in a controlled environment chamber. A prototype of the proposed sensor has been designed and implemented with its architecture and hardware design described in detail. For the experimental purposes, a wireless synchronization scheme between the reference and the gyroscopic sensor is also discussed. The experimental measurement has taken place to benchmark the performance of the realized sensor. The experimental data have been processed and analyzed, and the results have been presented. The gyroscopic sensor has shown satisfactory results. The sensor has an accuracy of 0.06 degrees/s, standard deviation of 0.45 degrees/s, and hysteresis of 0.08 degrees/s.
  •  
3.
  •  
4.
  • Nguyen, Thanh N, et al. (författare)
  • Global Impact of the COVID-19 Pandemic on Stroke Volumes and Cerebrovascular Events: A 1-Year Follow-up.
  • 2023
  • Ingår i: Neurology. - 1526-632X. ; 100:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Declines in stroke admission, IV thrombolysis (IVT), and mechanical thrombectomy volumes were reported during the first wave of the COVID-19 pandemic. There is a paucity of data on the longer-term effect of the pandemic on stroke volumes over the course of a year and through the second wave of the pandemic. We sought to measure the effect of the COVID-19 pandemic on the volumes of stroke admissions, intracranial hemorrhage (ICH), IVT, and mechanical thrombectomy over a 1-year period at the onset of the pandemic (March 1, 2020, to February 28, 2021) compared with the immediately preceding year (March 1, 2019, to February 29, 2020).We conducted a longitudinal retrospective study across 6 continents, 56 countries, and 275 stroke centers. We collected volume data for COVID-19 admissions and 4 stroke metrics: ischemic stroke admissions, ICH admissions, IVT treatments, and mechanical thrombectomy procedures. Diagnoses were identified by their ICD-10 codes or classifications in stroke databases.There were 148,895 stroke admissions in the 1 year immediately before compared with 138,453 admissions during the 1-year pandemic, representing a 7% decline (95% CI [95% CI 7.1-6.9]; p < 0.0001). ICH volumes declined from 29,585 to 28,156 (4.8% [5.1-4.6]; p < 0.0001) and IVT volume from 24,584 to 23,077 (6.1% [6.4-5.8]; p < 0.0001). Larger declines were observed at high-volume compared with low-volume centers (all p < 0.0001). There was no significant change in mechanical thrombectomy volumes (0.7% [0.6-0.9]; p = 0.49). Stroke was diagnosed in 1.3% [1.31-1.38] of 406,792 COVID-19 hospitalizations. SARS-CoV-2 infection was present in 2.9% ([2.82-2.97], 5,656/195,539) of all stroke hospitalizations.There was a global decline and shift to lower-volume centers of stroke admission volumes, ICH volumes, and IVT volumes during the 1st year of the COVID-19 pandemic compared with the prior year. Mechanical thrombectomy volumes were preserved. These results suggest preservation in the stroke care of higher severity of disease through the first pandemic year.This study is registered under NCT04934020.
  •  
5.
  •  
6.
  • Kanai, M, et al. (författare)
  • 2023
  • swepub:Mat__t
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy