SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Spanakis E. K.) "

Sökning: WFRF:(Spanakis E. K.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Klonoff, D. C., et al. (författare)
  • A Glycemia Risk Index (GRI) of Hypoglycemia and Hyperglycemia for Continuous Glucose Monitoring Validated by Clinician Ratings
  • 2022
  • Ingår i: Journal of Diabetes Science and Technology. - : SAGE Publications. - 1932-2968.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: A composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data. Methods: We assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia. We used principal component analysis and multiple regressions to develop a model to predict the clinician ranking based on seven standard metrics in an Ambulatory Glucose Profile: very low–glucose and low-glucose hypoglycemia; very high–glucose and high-glucose hyperglycemia; time in range; mean glucose; and coefficient of variation. Results: The analysis showed that clinician rankings depend on two components, one related to hypoglycemia that gives more weight to very low-glucose than to low-glucose and the other related to hyperglycemia that likewise gives greater weight to very high-glucose than to high-glucose. These two components should be calculated and displayed separately, but they can also be combined into a single Glycemia Risk Index (GRI) that corresponds closely to the clinician rankings of the overall quality of glycemia (r = 0.95). The GRI can be displayed graphically on a GRI Grid with the hypoglycemia component on the horizontal axis and the hyperglycemia component on the vertical axis. Diagonal lines divide the graph into five zones (quintiles) corresponding to the best (0th to 20th percentile) to worst (81st to 100th percentile) overall quality of glycemia. The GRI Grid enables users to track sequential changes within an individual over time and compare groups of individuals. Conclusion: The GRI is a single-number summary of the quality of glycemia. Its hypoglycemia and hyperglycemia components provide actionable scores and a graphical display (the GRI Grid) that can be used by clinicians and researchers to determine the glycemic effects of prescribed and investigational treatments.
  •  
2.
  • Ash, G. I., et al. (författare)
  • Establishing a Global Standard for Wearable Devices in Sport and Exercise Medicine: Perspectives from Academic and Industry Stakeholders
  • 2021
  • Ingår i: Sports Medicine. - : Springer Science and Business Media LLC. - 0112-1642 .- 1179-2035. ; 51, s. 2237-2250
  • Tidskriftsartikel (refereegranskat)abstract
    • Millions of consumer sport and fitness wearables (CSFWs) are used worldwide, and millions of datapoints are generated by each device. Moreover, these numbers are rapidly growing, and they contain a heterogeneity of devices, data types, and contexts for data collection. Companies and consumers would benefit from guiding standards on device quality and data formats. To address this growing need, we convened a virtual panel of industry and academic stakeholders, and this manuscript summarizes the outcomes of the discussion. Our objectives were to identify (1) key facilitators of and barriers to participation by CSFW manufacturers in guiding standards and (2) stakeholder priorities. The venues were the Yale Center for Biomedical Data Science Digital Health Monthly Seminar Series (62 participants) and the New England Chapter of the American College of Sports Medicine Annual Meeting (59 participants). In the discussion, stakeholders outlined both facilitators of (e.g., commercial return on investment in device quality, lucrative research partnerships, and transparent and multilevel evaluation of device quality) and barriers (e.g., competitive advantage conflict, lack of flexibility in previously developed devices) to participation in guiding standards. There was general agreement to adopt Keadle et al.'s standard pathway for testing devices (i.e., benchtop, laboratory, field-based, implementation) without consensus on the prioritization of these steps. Overall, there was enthusiasm not to add prescriptive or regulatory steps, but instead create a networking hub that connects companies to consumers and researchers for flexible guidance navigating the heterogeneity, multi-tiered development, dynamicity, and nebulousness of the CSFW field.
  •  
3.
  • Zicha, S., et al. (författare)
  • Comparative analytical performance of multiple plasma A beta 42 and A beta 40 assays and their ability to predict positron emission tomography amyloid positivity
  • 2022
  • Ingår i: Alzheimers & Dementia. - : Wiley. - 1552-5260 .- 1552-5279.
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction This report details the approach taken to providing a dataset allowing for analyses on the performance of recently developed assays of amyloid beta (A beta) peptides in plasma and the extent to which they improve the prediction of amyloid positivity. Methods Alzheimer's Disease Neuroimaging Initiative plasma samples with corresponding amyloid positron emission tomography (PET) data were run on six plasma A beta assays. Statistical tests were performed to determine whether the plasma A beta measures significantly improved the area under the receiver operating characteristic curve for predicting amyloid PET status compared to age and apolipoprotein E (APOE) genotype. Results The age and APOE genotype model predicted amyloid status with an area under the curve (AUC) of 0.75. Three assays improved AUCs to 0.81, 0.81, and 0.84 (P < .05, uncorrected for multiple comparisons). Discussion Measurement of A beta in plasma contributes to addressing the amyloid component of the ATN (amyloid/tau/neurodegeneration) framework and could be a first step before or in place of a PET or cerebrospinal fluid screening study. Highlights The Foundation of the National Institutes of Health Biomarkers Consortium evaluated six plasma amyloid beta (A beta) assays using Alzheimer's Disease Neuroimaging Initiative samples. Three assays improved prediction of amyloid status over age and apolipoprotein E (APOE) genotype. Plasma A beta 42/40 predicted amyloid positron emission tomography status better than A beta 42 or A beta 40 alone.
  •  
4.
  • Tian, Tiffany, et al. (författare)
  • Diabetes Technology Meeting 2023
  • 2024
  • Ingår i: Journal of Diabetes Science and Technology. - : Diabetes Technology Society. - 1932-2968.
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Diabetes Technology Society hosted its annual Diabetes Technology Meeting from November 1 to November 4, 2023. Meeting topics included digital health; metrics of glycemia; the integration of glucose and insulin data into the electronic health record; technologies for insulin pumps, blood glucose monitors, and continuous glucose monitors; diabetes drugs and analytes; skin physiology; regulation of diabetes devices and drugs; and data science, artificial intelligence, and machine learning. A live demonstration of a personalized carbohydrate dispenser for people with diabetes was presented.
  •  
5.
  • Stamoulou, E, et al. (författare)
  • Harmonization Strategies in Multicenter MRI-Based Radiomics
  • 2022
  • Ingår i: Journal of imaging. - : MDPI AG. - 2313-433X. ; 8:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Radiomics analysis is a powerful tool aiming to provide diagnostic and prognostic patient information directly from images that are decoded into handcrafted features, comprising descriptors of shape, size and textural patterns. Although radiomics is gaining momentum since it holds great promise for accelerating digital diagnostics, it is susceptible to bias and variation due to numerous inter-patient factors (e.g., patient age and gender) as well as inter-scanner ones (different protocol acquisition depending on the scanner center). A variety of image and feature based harmonization methods has been developed to compensate for these effects; however, to the best of our knowledge, none of these techniques has been established as the most effective in the analysis pipeline so far. To this end, this review provides an overview of the challenges in optimizing radiomics analysis, and a concise summary of the most relevant harmonization techniques, aiming to provide a thorough guide to the radiomics harmonization process.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy