SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Suvdantsetseg E.) "

Sökning: WFRF:(Suvdantsetseg E.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bortot, Sara, et al. (författare)
  • BELLA : a multi-point dynamics code for safety-informed design of fast reactors
  • 2015
  • Ingår i: Annals of Nuclear Energy. - : PERGAMON-ELSEVIER SCIENCE LTD. - 0306-4549 .- 1873-2100. ; 85, s. 228-235
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, the multi-point dynamics code BELLA and its benchmarking with respect to SAS4A/SASSYS-1 is described for a small fast reactor cooled with natural convection of lead (ELECTRA). It is shown that BELLA is capable of reproducing the magnitude of mass-flow, reactivity, power and temperature excursions during design extension conditions with an accuracy better than 10%. Hence, the BELLA code can be used for safety-informed design and stability analyses of fast reactor systems, permitting to isolate essential phenomena and trends of significance for their safety assessment. (C) 2015 Elsevier Ltd. All rights reserved.
  •  
2.
  • Suvdantsetseg, Erdenechimeg, et al. (författare)
  • Preliminary transient analysis of the Autonomous Reactivity Control system for fast reactors
  • 2015
  • Ingår i: Annals of Nuclear Energy. - : Elsevier BV. - 0306-4549 .- 1873-2100. ; 77, s. 47-64
  • Tidskriftsartikel (refereegranskat)abstract
    • A preliminary parametric dynamic response study of the Autonomous Reactivity Control (ARC) system is performed for a large fast reactor core subjected to the following postulated design-extension accident scenarios: unprotected overpower (UTOP), unprotected loss of flow (ULOF) and unprotected loss of heat sink (ULOHS). The results show that the ARC system could prevent fuel and cladding failure as well as coolant boiling during UTOP and can lower transient temperatures during ULOHS. However, in case of ULOF, the design space examined the ARC system did not prevent exceeding permissible cladding temperature and introduced instability. A more thorough analysis is recommended.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Bortot, Sara (1)
Wallenius, Janne (1)
Suvdantsetseg, E. (1)
Suvdantsetseg, Erden ... (1)
Qvist, Staffan, 1986 ... (1)
Greenspan, E. (1)
Lärosäte
Kungliga Tekniska Högskolan (2)
Uppsala universitet (1)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (2)
Teknik (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy