SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Troelsen A) "

Sökning: WFRF:(Troelsen A)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Skuladottir, AT, et al. (författare)
  • A genome-wide meta-analysis identifies 50 genetic loci associated with carpal tunnel syndrome
  • 2022
  • Ingår i: Nature communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 13:1, s. 1598-
  • Tidskriftsartikel (refereegranskat)abstract
    • Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy and has a largely unknown underlying biology. In a genome-wide association study of CTS (48,843 cases and 1,190,837 controls), we found 53 sequence variants at 50 loci associated with the syndrome. The most significant association is with a missense variant (p.Glu366Lys) in SERPINA1 that protects against CTS (P = 2.9 × 10−24, OR = 0.76). Through various functional analyses, we conclude that at least 22 genes mediate CTS risk and highlight the role of 19 CTS variants in the biology of the extracellular matrix. We show that the genetic component to the risk is higher in bilateral/recurrent/persistent cases than nonrecurrent/nonpersistent cases. Anthropometric traits including height and BMI are genetically correlated with CTS, in addition to early hormonal-replacement therapy, osteoarthritis, and restlessness. Our findings suggest that the components of the extracellular matrix play a key role in the pathogenesis of CTS.
  •  
2.
  • Gromov, K., et al. (författare)
  • Varying but reduced use of postoperative mobilization restrictions after primary total hip arthroplasty in Nordic countries: a questionnaire-based study
  • 2019
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 90:2, s. 143-147
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose Mobilization has traditionally been restricted following total hip arthroplasty (THA) in an attempt to reduce the risk of dislocation and muscle detachment. However, recent studies have questioned the effect and rationale underlying such restrictions. We investigated the use of postoperative restrictions and possible differences in mobilization protocols following primary THA in Denmark (DK), Finland (FIN), Norway (NO), and Sweden (SWE).Patients and methods All hospitals performing primary THA in the participating countries were identified from the latest national THA registry report. A questionnaire containing questions regarding standard surgical procedure, use of restrictions, and postoperative mobilization protocol was distributed to all hospitals through national representatives for each arthroplasty registry.Results 83% to 94% (n = 167) of the 199 hospitals performing THA in DK, FIN, NO, and SWE returned correctly filled out questionnaires. A posterolateral approach was used by 77% of the hospitals. 92% of the hospitals had a standardized mobilization protocol. 50%, 41%, 19%, and 38% of the hospitals in DK, FIN, NO, and SWE, respectively, did not have any postoperative restrictions. If utilized, restrictions were applied for a median of 6 weeks. Two-thirds of all hospitals have changed their mobilization protocol within the last 5 yearsall but 2 to a less restrictive protocol.Interpretation Use of postoperative restrictions following primary THA differs between the Nordic countries, with 19% to 50% allowing mobilization without any restrictions. There has been a strong tendency towards less restrictive mobilization over the last 5 years.
  •  
3.
  • Nebergall, A. K., et al. (författare)
  • Stable Fixation of a Cementless, Proximally Coated, Double Wedged, Double Tapered Femoral Stem in Total Hip Arthroplasty: A 5-Year Radiostereometric Analysis
  • 2016
  • Ingår i: Journal of Arthroplasty. - : Elsevier BV. - 0883-5403. ; 31:6, s. 1267-1274
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The objective of this 5-year prospective study of 51 hips was to assess migration of a cementless tapered femoral stem using radiostereometric analysis (RSA), plain radiographs (radiolucencies), and patient-reported outcome measures (PROMs). Methods: Forty-seven patients (51 hips) agreed to participate in this prospective RSA study. All patients received a Taperloc stem. Tantalum beads were inserted into the femoral bone surrounding the stem to measure migration using RSA. RSA films, plain radiograph, and PROM follow-up were obtained immediately after surgery, 6 months, 1, 2, 3, and 5 years after surgery. Results: The median (interquartile range) subsidence was 0.03 mm (-0.23 to 0.06) at 5 years, with no significant differences over time. Four outlier stems had >1.5 mm of subsidence by 1 year. No stem showed radiolucencies in more than 3 zones during the 5 years. All PROMs remained favorable at 5 years, suggesting an excellent outcome. There were no stems revised for mechanical loosening; 1 stem was revised for an infection. Conclusion: After initial settling, the cementless tapered femoral stems in our series were stable. The 4 outlier stems with >1.5 mm of subsidence by 1 year remain stable at 5 years. RSA was the most sensitive method of detection for stems at greater risk for potential future failure. This report adds contributions to the positive results associated with this type of fixation. The results at 5 years showed excellent midterm survivorship in this cohort with a cementless tapered femoral component. (C) 2015 Elsevier Inc. All rights reserved.
  •  
4.
  • Nebergall, A. K., et al. (författare)
  • Thirteen- Year Evaluation of Highly Cross-Linked Polyethylene Articulating With Either 28-mm or 36-mm Femoral Heads Using Radiostereometric Analysis and Computerized Tomography
  • 2016
  • Ingår i: Journal of Arthroplasty. - : Elsevier BV. - 0883-5403. ; 31:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The objective of this 13-year prospective evaluation of highly cross-linked ultra high molecular weight polyethylene (HXLPE) was to (1) assess the long-term wear of HXLPE articulating with 2 femoral head sizes using radiostereometric analysis (RSA) and to (2) determine if osteolysis is a concern with this material through the use of plain radiographs and computerized tomography (CT). Methods: All patients received a Longevity HXLPE liner with tantalum beads and either a 28-mm or 36-mm femoral head. Twelve patients (6 in each head size group) agreed to return for 13-year RSA, plain radiograph, and CT follow-up. The 1-year and 13-year plain radiographs as well as the CT scans were analyzed for the presence of osteolysis. Results: The 13-year mean +/- standard error steady-state wear was 0.05 +/- 0.02 mm with no significant increase over time or between the 2 head size groups. Two patients' CT scans showed radiolucent regions in the acetabulum of 4.51 cm(3) and 11.25 cm(3), respectively. In one patient, this area corresponded to a partially healed degenerative cyst treated with autograft during surgery. The second patient had an acetabular protrusio treated with autograft, and the CT scan revealed areas of remodeling of this graft. One patient's 13-year plain radiographs showed evidence of cup loosening and linear radiolucencies in zones 2 and 3. Conclusion: There was no evidence of significant wear over time using RSA. The CT scans did not show evidence of osteolysis due to wear particles. These results suggest that this material has reduced wear compared to conventional polyethylene, irrespective of head size.
  •  
5.
  •  
6.
  • Bangsbo, Jens, et al. (författare)
  • Copenhagen Consensus statement 2019 : physical activity and ageing
  • 2019
  • Ingår i: British Journal of Sports Medicine. - London : BMJ Publishing Group Ltd. - 0306-3674 .- 1473-0480. ; 53:14, s. 856-858
  • Tidskriftsartikel (refereegranskat)abstract
    • From 19th to 22nd November 2018, 26 researchers representing nine countries and a variety of academic disciplines met in Snekkersten, Denmark, to reach evidence-based consensus about physical activity and older adults. It was recognised that the term ‘older adults’ represents a highly heterogeneous population. It encompasses those that remain highly active and healthy throughout the life-course with a high intrinsic capacity to the very old and frail with low intrinsic capacity. The consensus is drawn from a wide range of research methodologies within epidemiology, medicine, physiology, neuroscience, psychology and sociology, recognising the strength and limitations of each of the methods. Much of the evidence presented in the statements is based on longitudinal associations from observational and randomised controlled intervention studies, as well as quantitative and qualitative social studies in relatively healthy community-dwelling older adults. Nevertheless, we also considered research with frail older adults and those with age-associated neurodegenerative diseases, such as Alzheimer’s and Parkinson’s disease, and in a few cases molecular and cellular outcome measures from animal studies. The consensus statements distinguish between physical activity and exercise. Physical activity is used as an umbrella term that includes both structured and unstructured forms of leisure, transport, domestic and work-related activities. Physical activity entails body movement that increases energy expenditure relative to rest, and is often characterised in terms of intensity from light, to moderate to vigorous. Exercise is defined as a subset of structured physical activities that are more specifically designed to improve cardiorespiratory fitness, cognitive function, flexibility balance, strength and/or power. This statement presents the consensus on the effects of physical activity on older adults’ fitness, health, cognitive functioning, functional capacity, engagement, motivation, psychological well-being and social inclusion. It also covers the consensus on physical activity implementation strategies. While it is recognised that adverse events can occur during exercise, the risk can be minimised by carefully choosing the type of activity undertaken and by consultation with the individual’s physician when warranted, for example, when the individual is frail, has a number of co-morbidities, or has exercise-related symptoms, such as chest pain, heart arrhythmia or dizziness. The consensus was obtained through an iterative process that began with the presentation of the state-of-the-science in each domain, followed by group and plenary discussions. Ultimately, the participants reached agreement on the 30-item consensus statements.
  •  
7.
  • Bunyoz, K. I., et al. (författare)
  • No difference in whole-blood metal ions between 32-mm and 36-to 44-mm femoral heads in metal-on-polyethylene total hip arthroplasty: a 2-year report from a randomised control trial
  • 2023
  • Ingår i: HIP International. - : SAGE Publications. - 1120-7000 .- 1724-6067. ; 33:2, s. 184-192
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: To investigate the effect of femoral head size on blood metal-ion levels caused by taper corrosion in metal-on-polyethylene total hip arthroplasty, comparing 36- to 44-mm heads with 32-mm heads. Methods: In a randomised, controlled, single-blinded trial, 96 patients were allocated to receive either a 32-mm metal head or the largest possible metal head (36-44 mm) that could be accommodated in the thinnest available vitamin E, cross-linked polyethylene insert. Blood metal ion levels were collected at 1- and 2-year follow-ups. Results: At 1-year, metal-ion levels did not differ between the groups. The median (interquartile range) blood-ion levels for the 32-mm versus the 36- to 44-mm group were 0.11 mu g/L (0.08-0.15) versus 0.12 mu g/L (0.08-0.22), p = 0.546, for cobalt, 0.50 mu g/L (0.50-0.59) versus 0.50 mu g/L (0.50-1.20), p = 0.059, for chromium and 1.58 mu g/L (1.38-2.05) versus 1.48 mu g/L (1.14-1.87), p = 0.385, for titanium. At 2 years, there was no difference either and the corresponding values were 0.15 mu g/L (0.12-0.24) versus 0.18 mu g/L (0.12-0.28), p = 0.682 for cobalt, 0.50 mu g/L (0.50-0.50) versus 0.50 mu g/L (0.50-0.57), p = 0.554, for chromium and 1.54 mu g/L (1.16-1.87) versus 1.42 mu g/L (1.01-1.72), p = 0.207 for titanium. Conclusions: The use of the largest possible metal head (36-44 mm) compared to a 32-mm head in metal-on-polyethylene bearings does not appear to elevate blood metal-ion levels up to 2 years postoperatively. As taper corrosion is probably time-dependent, longer-term reports are needed to evaluate the association between large metal heads and blood metal ion levels. Trial registration: ClinicalTrials.gov (reg. ID NCT0231 6704)
  •  
8.
  • Tsikandylakis, Georgios, et al. (författare)
  • Does the use of the largest possible metal head increase the wear of vitamin E-doped cross-linked polyethylene? Two-year results from a randomized controlled trial
  • 2021
  • Ingår i: Bone & Joint Journal. - 2049-4394. ; 103B:7, s. 1206-1214
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty. Methods In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes. Results At two years, 44 patients in each group were available for RSA assessment. The median total two-year proximal head penetration was -0.02 mm (IQR -0.09 to 0.07; p = 0.548) for the largest possible head and -0.01 mm (IQR -0.07 to 0.10; p = 0.525) for 32 mm heads. Their difference was not statistically significant (p = 0.323). Neither group demonstrated a bedding-in period. The median steady-state volumetric wear rates were 6.1 mm(3)/year (IQR -59 to 57) and 3.5 mm(3)/year (-21 to 34) respectively, and did not differ between the groups (p = 0.848). There were no statistically significant differences in periacetabular radiolucencies or patient-reported outcomes. Conclusion The use of the largest possible metal head did not increase vitamin E-doped cross-linked polyethylene wear compared with 32 mm heads at two years. Linear wear was negligible and volumetric wear rates were very low in both head size groups. There was a tendency towards higher values of volumetric wear in large heads that warrants longer-term evaluation before any definite conclusions about the association between head size and wear can be drawn.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy