SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Truong My) "

Sökning: WFRF:(Truong My)

  • Resultat 1-12 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Håkansson, Claes, et al. (författare)
  • Inter-modality assessment of medial temporal lobe atrophy in a non-demented population: application of a visual rating scale template across radiologists with varying clinical experience
  • 2022
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 32, s. 1127-1134
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To assess inter-modality agreement and accuracy for medial temporal lobe atrophy (MTA) ratings across radiologists with varying clinical experience in a non-demented population. Methods Four raters (two junior radiologists and two senior neuroradiologists) rated MTA on CT and MRI scans using Scheltens' MTA scale. Ratings were compared to a consensus rating by two experienced neuroradiologists for estimation of true positive and negative rates (TPR and TNR) and over- and underestimation of MTA. Inter-modality agreement expressed as Cohen's kappa (dichotomized data), Cohen's kappa(w), and two-way mixed, single measures, consistency ICC (ordinal data) were determined. Adequate agreement was defined as kappa/kappa(w) >= 0.80 and ICC >= 0.80 (significance level at 95% CI >= 0.65). Results Forty-nine subjects (median age 72 years, 27% abnormal MTA) with cognitive impairment were included. Only junior radiologists achieved adequate agreement expressed as Cohen's kappa. All raters achieved adequate agreement expressed as Cohen's kappa(w) and ICC. True positive rates varied from 69 to 100% and TNR varied from 85 to 100%. No under- or overestimation of MTA was observed. Ratings did not differ between radiologists. Conclusion We conclude that radiologists with varying experience achieve adequate inter-modality agreement and similar accuracy when Scheltens' MTA scale is used to rate MTA on a non-demented population. However, TPR varied between radiologists which could be attributed to rating style differences.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Truong, My, et al. (författare)
  • Classifications of atherosclerotic plaque components with T1 and T2* mapping in 11.7 T MRI
  • 2021
  • Ingår i: European Journal of Radiology Open. - : Elsevier BV. - 2352-0477. ; 8, s. 100323-100323
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and aims: Histopathology is the gold standard for analysis of atherosclerotic plaques but has drawbacks due to the destructive nature of the method. Ex vivo MRI is a non-destructive method to image whole plaques. Our aim was to use quantitative high field ex vivo MRI to classify plaque components, with histology as gold standard.Methods: Surgically resected carotid plaques from 12 patients with recent TIA or stroke were imaged at 11.7 T MRI. Quantitative T1/T2* mapping sequences and qualitative T1/T2* gradient echo sequences with voxel size of 30 × 30 × 60 μm3 were obtained prior to histological preparation, sectioning and staining for lipids, inflammation, hemorrhage, and fibrous tissue. Regions of interest (ROI) were selected based on the histological staining at multiple levels matched between histology and MRI. The MRI parameters of each ROI were then analyzed with quadratic discriminant analysis (QDA) for classification.Results: A total of 965 ROIs, at 70 levels matched between histology and MRI, were registered based on histological staining. In the nine plaques where three or more plaque components were possible to co-localize with MRI, the mean degree of misclassification by QDA was 16.5 %. One of the plaques contained mostly fibrous tissue and lipids and had no misclassifications, and two plaques mostly contained fibrous tissue. QDA generally showed good classification for fibrous tissue and lipids, whereas plaques with hemorrhage and inflammation had more misclassifications.Conclusion: 11.7 T ex vivo high field MRI shows good visual agreement with histology in carotid plaques. T1/T2* maps analyzed with QDA is a promising non-destructive method to classify plaque components, but with a higher degree of misclassifications in plaques with hemorrhage or inflammation.
  •  
8.
  •  
9.
  • Truong, My, et al. (författare)
  • Sub-micrometer morphology of human atherosclerotic plaque revealed by synchrotron radiation-based μCT—A comparison with histology
  • 2022
  • Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 17:4, s. 1-18
  • Tidskriftsartikel (refereegranskat)abstract
    • Histology is a long standing and well-established gold standard for pathological characterizations. In recent years however, synchrotron radiation-based micro-computed tomography (SRμCT) has become a tool for extending the imaging of two-dimensional thin sections into three-dimensional imaging of tissue blocks, enabling so-called virtual histology with arbitrary clipping planes, volumetric rendering and automatic segmentation. In this study, we present a thorough characterization of human carotid plaques after endarterectomy of patients with stroke or transient ischemic attack (TIA), investigating several different pathologic structures using both SRμCT and histology. Phase-contrast SRμCT was performed with two different magnifications (voxel sizes 6.5 μm and 0.65 μm, respectively), and histology was performed with multiple different stainings (Alpha-actin, Glycophorin A, von Kossa, Movat, CD68). The 0.65 μm high-resolution SRμCT was performed on selected areas with plaque typical relevant morphology, identified on the 6.5 μm low-resolution SRμCT. The tomography datasets were reconstructed with additional 3D volume rendering and compared to histology. In total, nine different regions with typical pathologic structures were identified and imaged with high-resolution SRμCT. The results show many characteristics typical for advanced atherosclerotic plaques, clinically relevant, namely ruptures with thrombosis, neo-vascularization, inflammatory infiltrates in shoulder regions, lipid rich necrotic cores (LRNC), thin fibrous cap, calcifications, lumen irregularities, and changes in vessel wall structures such as the internal elastic membrane. This method’s non-destructive nature renders details of micro-structures with an excellent visual likeness to histology, with the additional strength of multiplanar and 3D visualization and the possibility of multiple re-scans.
  •  
10.
  • Truong, My, et al. (författare)
  • Subacute vessel wall imaging at 7-T MRI in post-thrombectomy stroke patients
  • 2019
  • Ingår i: Neuroradiology. - : Springer Science and Business Media LLC. - 1432-1920 .- 0028-3940. ; 61:10, s. 1145-1153
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeReports from 3-T vessel wall MRI imaging have shown contrast enhancement following thrombectomy for acute stroke, suggesting potential intimal damage. Comparisons have shown higher SNR and more lesions detected by vessel wall imaging when using 7 T compared with 3 T. The aim of this study was to investigate the vessel walls after stent retriever thrombectomy using high-resolution vessel wall imaging at 7 T.MethodsSeven patients with acute stroke caused by occlusion of the distal internal carotid artery (T-occlusion), or proximal medial cerebral artery, and treated by stent retriever thrombectomy with complete recanalization were included and examined by 7-T MRI within 2 days. The MRI protocol included a high-resolution black blood sequence with prospective motion correction (iMOCO), acquired before and after contrast injection. Flow measurements were performed in the treated and untreated M1 segments.ResultsAll subjects completed the MRI examination. Image quality was independently rated as excellent by two neuroradiologists for all cases, and the level of motion artifacts did not impair diagnostic quality, despite severe motion in some cases. Contrast enhancement correlated with the deployment location of the stent retrievers. Flow data showed complete restoration of flow after treatment.ConclusionVessel wall imaging with prospective motion correction can be performed in patients following thrombectomy with excellent imaging quality at 7 T. We show that vessel wall contrast enhancement is the normal post-operative state and corresponds to the deployment location of the stent retriever.
  •  
11.
  • Truong, My, et al. (författare)
  • The potential role of T2*-weighted multi-echo data image combination as an imaging marker for intraplaque hemorrhage in carotid plaque imaging
  • 2021
  • Ingår i: BMC Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 21:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Carotid atherosclerotic plaques with intraplaque hemorrhage (IPH) are associated with elevated stroke risk. IPH is predominantly imaged based on paramagnetic properties of the upstream hemoglobin degradation product methemoglobin. This is an explorative observational study to test the feasibility of a spoiled gradient echo based T2* weighted MRI sequence (3D MEDIC) for carotid plaque imaging, and to compare signs suggestive of the downstream degradation product hemosiderin on 3D MEDIC with signs of methemoglobin on a T1wBB sequence. Methods: Patients with recent TIA or stroke were selected based on the presence on non-calcified plaque components on CTA to promote an enriched prevalence of IPH in the material. Patients (n = 42) underwent 3T MRI with 3D MEDIC and 2D turbo spin echo T1w black blood (T1wBB). Images were independently evaluated by two neuroradiologists and Cohens Kappa was used for inter-reader agreement for each sequence. Results: The technical feasibility for 3D MEDIC, was 34/42 patients (81%). Non-calcified plaque components with susceptibility effect without simultaneous T1-shortening—a combination suggestive of hemosiderin, was seen in 13/34 of the plaques. An equally large group display elevated T1w signal in combination with signal loss on 3D MEDIC, a combination suggestive of both hemosiderin and methemoglobin. Cohen’s kappa for inter-reader agreement was 0.64 (CI 0.345–0.925) for 3D MEDIC and 0.94 (CI 0.81–1.00) for T1wBB. Conclusions: 3D MEDIC shows signal loss, without elevated T1w signal on T1wBB, in non-calcified tissue in many plaques in this group of patients. If further studies, including histological verification, confirm that the 3D MEDIC susceptibility effect is indeed caused by hemosiderin, 3D MEDIC could aid in the detection of IPH, beyond elevation of T1w signal.
  •  
12.
  • Aad, G, et al. (författare)
  • 2015
  • swepub:Mat__t
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-12 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy