SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Verberne H. J.) "

Search: WFRF:(Verberne H. J.)

  • Result 1-15 of 15
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Tabiri, S, et al. (author)
  • 2021
  • swepub:Mat__t
  •  
2.
  • Bravo, L, et al. (author)
  • 2021
  • swepub:Mat__t
  •  
3.
  • Glasbey, JC, et al. (author)
  • 2021
  • swepub:Mat__t
  •  
4.
  •  
5.
  • Khatri, C, et al. (author)
  • Outcomes after perioperative SARS-CoV-2 infection in patients with proximal femoral fractures: an international cohort study
  • 2021
  • In: BMJ open. - : BMJ. - 2044-6055. ; 11:11, s. e050830-
  • Journal article (peer-reviewed)abstract
    • Studies have demonstrated high rates of mortality in people with proximal femoral fracture and SARS-CoV-2, but there is limited published data on the factors that influence mortality for clinicians to make informed treatment decisions. This study aims to report the 30-day mortality associated with perioperative infection of patients undergoing surgery for proximal femoral fractures and to examine the factors that influence mortality in a multivariate analysis.SettingProspective, international, multicentre, observational cohort study.ParticipantsPatients undergoing any operation for a proximal femoral fracture from 1 February to 30 April 2020 and with perioperative SARS-CoV-2 infection (either 7 days prior or 30-day postoperative).Primary outcome30-day mortality. Multivariate modelling was performed to identify factors associated with 30-day mortality.ResultsThis study reports included 1063 patients from 174 hospitals in 19 countries. Overall 30-day mortality was 29.4% (313/1063). In an adjusted model, 30-day mortality was associated with male gender (OR 2.29, 95% CI 1.68 to 3.13, p<0.001), age >80 years (OR 1.60, 95% CI 1.1 to 2.31, p=0.013), preoperative diagnosis of dementia (OR 1.57, 95% CI 1.15 to 2.16, p=0.005), kidney disease (OR 1.73, 95% CI 1.18 to 2.55, p=0.005) and congestive heart failure (OR 1.62, 95% CI 1.06 to 2.48, p=0.025). Mortality at 30 days was lower in patients with a preoperative diagnosis of SARS-CoV-2 (OR 0.6, 95% CI 0.6 (0.42 to 0.85), p=0.004). There was no difference in mortality in patients with an increase to delay in surgery (p=0.220) or type of anaesthetic given (p=0.787).ConclusionsPatients undergoing surgery for a proximal femoral fracture with a perioperative infection of SARS-CoV-2 have a high rate of mortality. This study would support the need for providing these patients with individualised medical and anaesthetic care, including medical optimisation before theatre. Careful preoperative counselling is needed for those with a proximal femoral fracture and SARS-CoV-2, especially those in the highest risk groups.Trial registration numberNCT04323644
  •  
6.
  • Bakker, G. J., et al. (author)
  • Pancreatic 18 F-FDG uptake is increased in type 2 diabetes patients compared to non-diabetic controls
  • 2019
  • In: Plos One. - : Public Library of Science (PLoS). - 1932-6203. ; 14:3
  • Journal article (peer-reviewed)abstract
    • Introduction Increasing evidence indicates that the development of type 2 diabetes is driven by chronic low grade beta-cell inflammation. However, it is unclear whether pancreatic inflammation can be noninvasively visualized in type 2 diabetes patients. We aimed to assess pancreatic 18 F-FDG uptake in type 2 diabetes patients and controls using 18 F-fluorodeoxylglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT). Material and methods In this retrospective cross-sectional study, we enrolled 20 type 2 diabetes patients and 65 controls who had undergone a diagnostic 18 F-FDG PET/CT scan and obtained standardized uptake values (SUVs) of pancreas and muscle. Pancreatic SUV was adjusted for background uptake in muscle and for fasting blood glucose concentrations. Results The maximum pancreatic SUVs adjusted for background muscle uptake (SUV max.m ) and fasting blood glucose concentration (SUV glucose ) were significantly higher in diabetes patients compared to controls (median 2.86 [IQR 2.24–4.36] compared to 2.15 [IQR 1.51–2.83], p = 0.006 and median 2.76 [IQR 1.18–4.34] compared to 1.91 [IQR 1.27–2.55], p<0.001, respectively). In linear regression adjusting for age and body mass index, diabetes remained the main predictor of SUV max.m and SUV glucose . Conclusion Pancreatic 18 F-FDG uptake adjusted for background muscle uptake and fasting blood glucose concentration was significantly increased in type 2 diabetes patients. © 2019 Bakker et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
  •  
7.
  • Bouter, K. E. C., et al. (author)
  • Differential metabolic effects of oral butyrate treatment in lean versus metabolic syndrome subjects article
  • 2018
  • In: Clinical and Translational Gastroenterology. - : Ovid Technologies (Wolters Kluwer Health). - 2155-384X. ; 9:5
  • Journal article (peer-reviewed)abstract
    • Background: Gut microbiota-derived short-chain fatty acids (SCFAs) have been associated with beneficial metabolic effects. However, the direct effect of oral butyrate on metabolic parameters in humans has never been studied. In this first in men pilot study, we thus treated both lean and metabolic syndrome male subjects with oral sodium butyrate and investigated the effect on metabolism. Methods: Healthy lean males (n = 9) and metabolic syndrome males (n = 10) were treated with oral 4 g of sodium butyrate daily for 4 weeks. Before and after treatment, insulin sensitivity was determined by a two-step hyperinsulinemic euglycemic clamp using [6,6-2H2]-glucose. Brown adipose tissue (BAT) uptake of glucose was visualized using 18F-FDG PET-CT. Fecal SCFA and bile acid concentrations as well as microbiota composition were determined before and after treatment. Results: Oral butyrate had no effect on plasma and fecal butyrate levels after treatment, but did alter other SCFAs in both plasma and feces. Moreover, only in healthy lean subjects a significant improvement was observed in both peripheral (median Rd: from 71 to 82 μmol/kg min, p < 0.05) and hepatic insulin sensitivity (EGP suppression from 75 to 82% p < 0.05). Although BAT activity was significantly higher at baseline in lean (SUVmax: 12.4 ± 1.8) compared with metabolic syndrome subjects (SUVmax: 0.3 ± 0.8, p < 0.01), no significant effect following butyrate treatment on BAT was observed in either group (SUVmax lean to 13.3 ± 2.4 versus metabolic syndrome subjects to 1.2 ± 4.1). Conclusions: Oral butyrate treatment beneficially affects glucose metabolism in lean but not metabolic syndrome subjects, presumably due to an altered SCFA handling in insulin-resistant subjects. Although preliminary, these first in men findings argue against oral butyrate supplementation as treatment for glucose regulation in human subjects with type 2 diabetes mellitus. © 2018 The Author(s).
  •  
8.
  • Slart, Riemer H. J. A., et al. (author)
  • Position paper of the EACVI and EANM on artificial intelligence applications in multimodality cardiovascular imaging using SPECT/CT, PET/CT, and cardiac CT
  • 2021
  • In: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer. - 1619-7070 .- 1619-7089. ; 48:5, s. 1399-1413
  • Journal article (peer-reviewed)abstract
    • In daily clinical practice, clinicians integrate available data to ascertain the diagnostic and prognostic probability of a disease or clinical outcome for their patients. For patients with suspected or known cardiovascular disease, several anatomical and functional imaging techniques are commonly performed to aid this endeavor, including coronary computed tomography angiography (CCTA) and nuclear cardiology imaging. Continuous improvement in positron emission tomography (PET), single-photon emission computed tomography (SPECT), and CT hardware and software has resulted in improved diagnostic performance and wide implementation of these imaging techniques in daily clinical practice. However, the human ability to interpret, quantify, and integrate these data sets is limited. The identification of novel markers and application of machine learning (ML) algorithms, including deep learning (DL) to cardiovascular imaging techniques will further improve diagnosis and prognostication for patients with cardiovascular diseases. The goal of this position paper of the European Association of Nuclear Medicine (EANM) and the European Association of Cardiovascular Imaging (EACVI) is to provide an overview of the general concepts behind modern machine learning-based artificial intelligence, highlights currently prefered methods, practices, and computational models, and proposes new strategies to support the clinical application of ML in the field of cardiovascular imaging using nuclear cardiology (hybrid) and CT techniques.
  •  
9.
  • Slart, Riemer H. J. A., et al. (author)
  • Procedural recommendations of cardiac PET/CT imaging : standardization in inflammatory-, infective-, infiltrative-, and innervation (4Is)-related cardiovascular diseases: a joint collaboration of the EACVI and the EANM
  • 2021
  • In: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer. - 1619-7070 .- 1619-7089. ; 48:4, s. 1016-1039
  • Journal article (peer-reviewed)abstract
    • With this document, we provide a standard for PET/(diagnostic) CT imaging procedures in cardiovascular diseases that are inflammatory, infective, infiltrative, or associated with dysfunctional innervation (4Is). This standard should be applied in clinical practice and integrated in clinical (multicenter) trials for optimal procedural standardization. A major focus is put on procedures using [18F]FDG, but 4Is PET radiopharmaceuticals beyond [18F]FDG are also described in this document. Whilst these novel tracers are currently mainly applied in early clinical trials, some multicenter trials are underway and we foresee in the near future their use in clinical care and inclusion in the clinical guidelines. Finally, PET/MR applications in 4Is cardiovascular diseases are also briefly described. Diagnosis and management of 4Is-related cardiovascular diseases are generally complex and often require a multidisciplinary approach by a team of experts. The new standards described herein should be applied when using PET/CT and PET/MR, within a multimodality imaging framework both in clinical practice and in clinical trials for 4Is cardiovascular indications.
  •  
10.
  • Slart, Riemer H J A, et al. (author)
  • Procedural recommendations of cardiac PET/CT imaging : standardization in inflammatory-, infective-, infiltrative-, and innervation- (4Is) related cardiovascular diseases
  • 2020
  • In: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 21:12, s. 1320-1330
  • Journal article (peer-reviewed)abstract
    • With this summarized document we share the standard for positron emission tomography (PET)/(diagnostic)computed tomography (CT) imaging procedures in cardiovascular diseases that are inflammatory, infective, infiltrative, or associated with dysfunctional innervation (4Is) as recently published in the European Journal of Nuclear Medicine and Molecular Imaging. This standard should be applied in clinical practice and integrated in clinical (multicentre) trials for optimal standardization of the procedurals and interpretations. A major focus is put on procedures using [18F]-2-fluoro-2-deoxyglucose ([18F]FDG), but 4Is PET radiopharmaceuticals beyond [18F]FDG are also described in this summarized document. Whilst these novel tracers are currently mainly applied in early clinical trials, some multicentre trials are underway and we foresee in the near future their use in clinical care and inclusion in the clinical guidelines. Diagnosis and management of 4Is related cardiovascular diseases are generally complex and often require a multidisciplinary approach by a team of experts. The new standards described herein should be applied when using PET/CT and PET/magnetic resonance, within a multimodality imaging framework both in clinical practice and in clinical trials for 4Is cardiovascular indications.
  •  
11.
  • Hyafil, Fabien, et al. (author)
  • EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras
  • 2019
  • In: European Journal of Hybrid Imaging. - : Springer Nature. - 2510-3636. ; 3:1
  • Journal article (peer-reviewed)abstract
    • An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.
  •  
12.
  • Sciagrà, Roberto, et al. (author)
  • EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging
  • 2021
  • In: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer. - 1619-7070 .- 1619-7089. ; 48:4, s. 1040-1069
  • Journal article (peer-reviewed)abstract
    • The use of cardiac PET, and in particular of quantitative myocardial perfusion PET, has been growing during the last years, because scanners are becoming widely available and because several studies have convincingly demonstrated the advantages of this imaging approach. Therefore, there is a need of determining the procedural modalities for performing high-quality studies and obtaining from this demanding technique the most in terms of both measurement reliability and clinical data. Although the field is rapidly evolving, with progresses in hardware and software, and the near perspective of new tracers, the EANM Cardiovascular Committee found it reasonable and useful to expose in an updated text the state of the art of quantitative myocardial perfusion PET, in order to establish an effective use of this modality and to help implementing it on a wider basis. Together with the many steps necessary for the correct execution of quantitative measurements, the importance of a multiparametric approach and of a comprehensive and clinically useful report have been stressed.
  •  
13.
  • Totzeck, Matthias, et al. (author)
  • Nuclear medicine in the assessment and prevention of cancer therapy-related cardiotoxicity : prospects and proposal of use by the European Association of Nuclear Medicine (EANM)
  • 2023
  • In: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Nature. - 1619-7070 .- 1619-7089. ; 50:3, s. 792-812
  • Journal article (peer-reviewed)abstract
    • Cardiotoxicity may present as (pulmonary) hypertension, acute and chronic coronary syndromes, venous thromboembolism, cardiomyopathies/heart failure, arrhythmia, valvular heart disease, peripheral arterial disease, and myocarditis. Many of these disease entities can be diagnosed by established cardiovascular diagnostic pathways. Nuclear medicine, however, has proven promising in the diagnosis of cardiomyopathies/heart failure, and peri- and myocarditis as well as arterial inflammation. This article first outlines the spectrum of cardiotoxic cancer therapies and the potential side effects. This will be complemented by the definition of cardiotoxicity using non-nuclear cardiovascular imaging (echocardiography, CMR) and biomarkers. Available nuclear imaging techniques are then presented and specific suggestions are made for their application and potential role in the diagnosis of cardiotoxicity.
  •  
14.
  • Trägårdh, Elin, et al. (author)
  • Systematic review of cost-effectiveness of myocardial perfusion scintigraphy in patients with ischaemic heart disease A report from the cardiovascular committee of the European Association of Nuclear Medicine. Endorsed by the European Association of Cardiovascular Imaging
  • 2017
  • In: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 18:8, s. 825-832
  • Research review (peer-reviewed)abstract
    • Coronary artery disease (CAD) is a major cause of death and disability. Several diagnostic tests, such as myocardial perfusion scintigraphy (MPS), are accurate for the detection of CAD, as well as having prognostic value for the prediction of cardiovascular events. Nevertheless, the diagnostic and prognostic value of these tests should be cost-effective and should lead to improved clinical outcome. We have reviewed the literature on the cost-effectiveness of MPS in different circumstances: (i) the diagnosis and management of CAD; (ii) comparison with exercise electrocardiography (ECG) and other imaging tests; (iii) as gatekeeper to invasive coronary angiography (ICA), (iv) the impact of appropriate use criteria; (v) acute chest pain, and (vi) screening of asymptomatic patients with type-2 diabetes. In total 57 reports were included. Although most non-invasive imaging tests are cost-effective compared with alternatives, the data conflict on which non-invasive strategy is the most cost-effective. Different definitions of cost-effectiveness further confound the subject. Computer simulations of clinical diagnosis and management are influenced by the assumptions made. For instance, diagnostic accuracy is often defined against an anatomical standard that is wrongly assumed to be perfect. Conflicting data arise most commonly from these incorrect or differing assumptions.
  •  
15.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-15 of 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view