SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vesseur Maud A. M.) "

Sökning: WFRF:(Vesseur Maud A. M.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Mattsson, Viktor, et al. (författare)
  • Muscle Analyzer System : Exploring Correlation Between Novel Microwave Resonator and Ultrasound-based Tissue Information in the Thigh
  • 2022
  • Ingår i: 2022 16TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP). - : Institute of Electrical and Electronics Engineers (IEEE). - 9788831299046
  • Konferensbidrag (refereegranskat)abstract
    • A microwave sensor to safely measure quality of muscle tissue for diagnosis and screening of diseases and medical conditions characterized by fat infiltration in muscle is presented. Fat infiltration in muscle may be seen by a lower dielectric constant of muscle at microwave frequencies corresponding to the large contrast between fat and muscle tissues. A planar resonator based on a bandstop filter and optimized to noninvasively interrogate muscle in the thigh on tissue quality is proposed. Currently, a study based on clinical trials is carried out, and, here, we present a preliminary correlation between skin and fat thicknesses and rectus femoris cross sectional area (CSA) measured with ultrasound and the proposed sensor's resonance frequency. CST simulations based on the ultrasound information guide the analysis. We see that although there are signs of a potential correlation between CSA and resonance, skin and fat variability is still an issue to overcome.
  •  
3.
  • Mattsson, Viktor, et al. (författare)
  • MAS : Standalone Microwave Resonator to Assess Muscle Quality
  • 2021
  • Ingår i: Sensors. - : MDPI. - 1424-8220. ; 21:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Microwave-based sensing for tissue analysis is recently gaining interest due to advantages such as non-ionizing radiation and non-invasiveness. We have developed a set of transmission sensors for microwave-based real-time sensing to quantify muscle mass and quality. In connection, we verified the sensors by 3D simulations, tested them in a laboratory on a homogeneous three-layer tissue model, and collected pilot clinical data in 20 patients and 25 healthy volunteers. This report focuses on initial sensor designs for the Muscle Analyzer System (MAS), their simulation, laboratory trials and clinical trials followed by developing three new sensors and their performance comparison. In the clinical studies, correlation studies were done to compare MAS performance with other clinical standards, specifically the skeletal muscle index, for muscle mass quantification. The results showed limited signal penetration depth for the Split Ring Resonator (SRR) sensor. New sensors were designed incorporating Substrate Integrated Waveguides (SIW) and a bandstop filter to overcome this problem. The sensors were validated through 3D simulations in which they showed increased penetration depth through tissue when compared to the SRR. The second-generation sensors offer higher penetration depth which will improve clinical data collection and validation. The bandstop filter is fabricated and studied in a group of volunteers, showing more reliable data that warrants further continuation of this development.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy