SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vetter I) "

Sökning: WFRF:(Vetter I)

  • Resultat 1-38 av 38
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abat, E., et al. (författare)
  • A layer correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test
  • 2011
  • Ingår i: Journal of Instrumentation. - : Institute of Physics (IOP). - 1748-0221. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions impinging on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.
  •  
2.
  • Abat, E., et al. (författare)
  • Combined performance studies for electrons at the 2004 ATLAS combined test-beam
  • 2010
  • Ingår i: Journal of Instrumentation. - : Institute of Physics (IOP). - 1748-0221. ; 5, s. P11006-
  • Tidskriftsartikel (refereegranskat)abstract
    • In 2004 at the ATLAS (A Toroidal LHC ApparatuS) combined test beam, one slice of the ATLAS barrel detector (including an Inner Detector set-up and the Liquid Argon calorimeter) was exposed to particles from the H8 SPS beam line at CERN. It was the first occasion to test the combined electron performance of ATLAS. This paper presents results obtained for the momentum measurement p with the Inner Detector and for the performance of the electron measurement with the LAr calorimeter (energy E linearity and resolution) in the presence of a magnetic field in the Inner Detector for momenta ranging from 20 GeV/c to 100 GeV/c. Furthermore the particle identification capabilities of the Transition Radiation Tracker, Bremsstrahlungs-recovery algorithms relying on the LAr calorimeter and results obtained for the E/p ratio and a way how to extract scale parameters will be discussed.
  •  
3.
  • Abat, E., et al. (författare)
  • Photon reconstruction in the ATLAS Inner Detector and Liquid Argon Barrel Calorimeter at the 2004 Combined Test Beam
  • 2011
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • The reconstruction of photons in the ATLAS detector is studied with data taken during the 2004 Combined Test Beam, where a full slice of the ATLAS detector was exposed to beams of particles of known energy at the CERN SPS. The results presented show significant differences in the longitudinal development of the electromagnetic shower between converted and unconverted photons as well as in the total measured energy. The potential to use the reconstructed converted photons as a means to precisely map the material of the tracker in front of the electromagnetic calorimeter is also considered. All results obtained are compared with a detailed Monte-Carlo simulation of the test-beam setup which is based on the same simulation and reconstruction tools as those used for the ATLAS detector itself.
  •  
4.
  • Abat, E., et al. (författare)
  • Study of the response of the ATLAS central calorimeter to pions of energies from 3 to 9 GeV
  • 2009
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002 .- 1872-9576. ; 607:2, s. 372-386
  • Tidskriftsartikel (refereegranskat)abstract
    • A fully instrumented slice of the ATLAS central detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. in this paper, the response of the central calorimeters to pions with energies in the range between 3 and 9 GeV is presented. The linearity and the resolution of the combined calorimetry (electromagnetic and hadronic calorimeters) was measured and compared to the prediction of a detector simulation program using the toolkit Geant 4. (C) 2009 Elsevier B.V. All rights reserved.
  •  
5.
  • Abata, E., et al. (författare)
  • Study of energy response and resolution of the ATLAS barrel calorimeter to hadrons of energies from 20 to 350 GeV
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 621:1-3, s. 134-150
  • Tidskriftsartikel (refereegranskat)abstract
    • A fully instrumented slice of the ATLAS detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the results of the measurements of the response of the barrel calorimeter to hadrons with energies in the range 20-350 GeV and beam impact points and angles corresponding to pseudo-rapidity values in the range 0.2-0.65 are reported. The results are compared to the predictions of a simulation program using the Geant 4 toolkit. (C) 2010 Published by Elsevier B.V.
  •  
6.
  •  
7.
  •  
8.
  • Abgrall, N., et al. (författare)
  • The large enriched germanium experiment for neutrinoless double beta decay (LEGEND)
  • 2017
  • Ingår i: AIP Conference Proceedings. - : Author(s). - 1551-7616 .- 0094-243X. ; 1894
  • Konferensbidrag (refereegranskat)abstract
    • The observation of neutrinoless double-beta decay (0νββ) would show that lepton number is violated, reveal that neu-trinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of ∼0.1 count /(FWHM·t·yr) in the region of the signal. The current generation 76Ge experiments GERDA and the Majorana Demonstrator, utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0νββ signal region of all 0νββ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale 76Ge experiment. The collaboration aims to develop a phased 0νββ experimental program with discovery potential at a half-life approaching or at 1028 years, using existing resources as appropriate to expedite physics results.
  •  
9.
  • Shepherd, L., et al. (författare)
  • Infection-related and -unrelated malignancies, HIV and the aging population
  • 2016
  • Ingår i: HIV Medicine. - : Wiley. - 1464-2662 .- 1468-1293. ; 17:8, s. 590-600
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: HIV-positive people have increased risk of infection-related malignancies (IRMs) and infection-unrelated malignancies (IURMs). The aim of the study was to determine the impact of aging on future IRM and IURM incidence. Methods: People enrolled in EuroSIDA and followed from the latest of the first visit or 1 January 2001 until the last visit or death were included in the study. Poisson regression was used to investigate the impact of aging on the incidence of IRMs and IURMs, adjusting for demographic, clinical and laboratory confounders. Linear exponential smoothing models forecasted future incidence. Results: A total of 15 648 people contributed 95 033 person-years of follow-up, of whom 610 developed 643 malignancies [IRMs: 388 (60%); IURMs: 255 (40%)]. After adjustment, a higher IRM incidence was associated with a lower CD4 count [adjusted incidence rate ratio (aIRR) CD4 count < 200 cells/μL: 3.77; 95% confidence interval (CI) 2.59, 5.51; compared with ≥ 500 cells/μL], independent of age, while a CD4 count < 200 cells/μL was associated with IURMs in people aged < 50 years only (aIRR: 2.51; 95% CI 1.40–4.54). Smoking was associated with IURMs (aIRR: 1.75; 95% CI 1.23, 2.49) compared with never smokers in people aged ≥ 50 years only, and not with IRMs. The incidences of both IURMs and IRMs increased with older age. It was projected that the incidence of IRMs would decrease by 29% over a 5-year period from 3.1 (95% CI 1.5–5.9) per 1000 person-years in 2011, whereas the IURM incidence would increase by 44% from 4.1 (95% CI 2.2–7.2) per 1000 person-years over the same period. Conclusions: Demographic and HIV-related risk factors for IURMs (aging and smoking) and IRMs (immunodeficiency and ongoing viral replication) differ markedly and the contribution from IURMs relative to IRMs will continue to increase as a result of aging of the HIV-infected population, high smoking and lung cancer prevalence and a low prevalence of untreated HIV infection. These findings suggest the need for targeted preventive measures and evaluation of the cost−benefit of screening for IURMs in HIV-infected populations.
  •  
10.
  •  
11.
  • Fusco, F.M., et al. (författare)
  • Isolation rooms for highly infectious diseases : an inventory of capabilities in European countries
  • 2009
  • Ingår i: Journal of Hospital Infection. - : Elsevier BV. - 0195-6701. ; 73:1, s. 15-23
  • Tidskriftsartikel (refereegranskat)abstract
    • Isolation of patients with highly infectious diseases (HIDs) in hospital rooms with adequate technical facilities is essential to reduce the risk of spreading disease. The European Network for Infectious Diseases (EUNID), a project co-funded by European Commission and involving 16 European Union member states, performed an inventory of high level isolation rooms (HIRs, hospital rooms with negative pressure and anteroom). In participating countries, HIRs are available in at least 211 hospitals, with at least 1789 hospital beds. The adequacy of this number is not known and will depend on prevailing circumstances. Sporadic HID cases can be managed in the available HIRs. HIRs could also have a role in the initial phases of an influenza pandemic. However, large outbreaks due to natural or to bioterrorist events will need management strategies involving healthcare facilities other than HIRs.
  •  
12.
  •  
13.
  •  
14.
  • Svensson, C. E., et al. (författare)
  • Collective rotational motion in the N=Z nucleus 36Ar
  • 2001
  • Ingår i: Nuclear Physics A. - 0375-9474. ; 682:1-4, s. 1-11
  • Tidskriftsartikel (refereegranskat)abstract
    • A superdeformed rotational band has been identified in the N = Z nucleus 36Ar, firmly linked to known low-spin states, and observed to its high-spin termination at Iπ = 16+. Lifetime measurements by the Doppler shift attenuation method establish a large low-spin deformation (β2 ≈ 0.46) and a decrease in the collectivity as the band approaches termination. Comparisons with cranked Nilsson-Strutinsky and large-scale spherical shell model calculations lead to a consistent description of the band based on a configuration in which four particles are promoted to the pf shell. With two major shells active for both protons and neutrons, yet a valence space dimension small enough to be approached from the shell model perspective, this band offers an excellent opportunity to investigate the microscopic structure of collective rotational motion in nuclei.
  •  
15.
  • Svensson, C. E., et al. (författare)
  • Lifetimes of superdeformed rotational states in 36Ar
  • 2001
  • Ingår i: Physical Review C - Nuclear Physics. - 0556-2813. ; 63:6, s. 613011-613015
  • Tidskriftsartikel (refereegranskat)abstract
    • Lifetimes have been measured in a superdeformed rotational band recently identified in the N = Z nucleus 36Ar. A large low-spin quadrupole deformation (β2=0.46±0.03) is confirmed and a decrease in the collectivity is observed as the high-spin band termination at Iπ=16+ is approached. Detailed comparisons of the experimental B(E2) values with the results of cranked Nilsson-Strutinsky and large-scale (s1/2d3/2)-pf spherical shell model calculations indicate the need for a more refined treatment of transition matrix elements close to termination in the former, and the inclusion of the complete sd-pf model space in the latter description of this highly-collective rotational band.
  •  
16.
  • Svensson, C. E., et al. (författare)
  • Lifetimes of superdeformed rotational states in [Formula Presented]
  • 2001
  • Ingår i: Physical Review C - Nuclear Physics. - 0556-2813. ; 63:6, s. 5-5
  • Tidskriftsartikel (refereegranskat)abstract
    • Lifetimes have been measured in a superdeformed rotational band recently identified in the [Formula Presented] nucleus [Formula Presented] A large low-spin quadrupole deformation [Formula Presented] is confirmed and a decrease in the collectivity is observed as the high-spin band termination at [Formula Presented] is approached. Detailed comparisons of the experimental [Formula Presented] values with the results of cranked Nilsson-Strutinsky and large-scale [Formula Presented] spherical shell model calculations indicate the need for a more refined treatment of transition matrix elements close to termination in the former, and the inclusion of the complete [Formula Presented] model space in the latter description of this highly-collective rotational band.
  •  
17.
  • Svensson, C. E., et al. (författare)
  • Superdeformation in the N = z Nucleus 36Ar : Experimental, deformed mean field, and spherical shell model descriptions
  • 2000
  • Ingår i: Physical Review Letters. - 0031-9007. ; 85:13, s. 2693-2696
  • Tidskriftsartikel (refereegranskat)abstract
    • A superdeformed rotational band has been identified in 36Ar, linked to known low-spin states, and observed to its high-spin termination at Iπ = 16+. Cranked Nilsson-Strutinsky and spherical shell model calculations assign the band to a configuration in which four pf-shell orbitals are occupied, leading to a low-spin deformation β2 ≈ 0.45. Two major shells are active for both protons and neutrons, yet the valence space remains small enough to be confronted with the shell model. This band thus provides an ideal case to study the microscopic structure of collective rotational motion.
  •  
18.
  • Ward, D., et al. (författare)
  • Band Structure of 68Ge
  • 2001
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 63:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The nucleus Ge-68 has been studied by gamma-ray spectroscopy following its population at high spin in the reaction Ca-40(S-32,4p) Ge-68. The reaction channel was selected with the Microball array and gamma rays were detected with the Gammasphere array. The level scheme is very complex, reflecting the many different, and presumably mixed, excitation modes in this nucleus. Nevertheless, there appear to be some simplifications in the spin range above 18 (h) over bar where we have identified a superdeformed band and several terminating bands. The results are compared with a cranked Nilsson-Strutinsky model without pairing.
  •  
19.
  • Althueser, L., et al. (författare)
  • GPU-based optical simulation of the DARWIN detector
  • 2022
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 17:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.
  •  
20.
  • Asztalos, S. J., et al. (författare)
  • Isotopic yields of neutron-rich nuclei from deep-inelastic reactions
  • 2000
  • Ingår i: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 6101:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We follow up on our earlier work involving a light projectile (Ca-48) to populate high spin states in neutron-rich nuclei with results from experiments involving a heavier projectile (Sm-154) fur the purposes of studying isotopic yields. These yields, which in some cases were mensurable down to a level of 0.1 of the total reaction cross section, are presented from three separate reactions. A trend in the isotopic yields towards N/Z equilibration is observed in one experiment having a large disparity in N/Z ratios between the projectile and target. In the two other reactions, where the N/Z driving force is less pronounced, the yields are instead clustered around the projectile and target nuclei. We present correlated projectilelike and targetlike fragment isotopic yields derived from gamma-gamma coincidences, a technique that enables one to partition the yield of an isotope according to the amount of neutron evaporation. Using this method we find that for the zero-neutron evaporation channel transfer occurs predominantly into the light fragment, consistent with the nature of the deep-inelastic mechanism. We further find that multiple-neutron evaporation contributes substantially to the yields of the isotopes.
  •  
21.
  • Asztalos, S J, et al. (författare)
  • Spin yields of neutron-rich nuclei from deep inelastic reactions
  • 1999
  • Ingår i: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 60:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The potential for using deep inelastic reactions to populate high-spin states in neutron-rich nuclei is studied in a series of experiments using GAMMASPHERE for gamma-ray detection and a silicon strip detector for measuring the angles of projectilelike and targetlike fragments. In three experiments 61 new transitions up to a maximum spin of 22 (h) over bar in 12 neutron-rich rare-earth nuclei were found. We observe that gamma-ray yields as a function of spin are flatter for all neutron transfer products than for inelastic excitation of either the projectile or target nucleus. Calculations are presented which indicate that this difference cannot be accounted for by quasielastic processes, but more likely are the result of larger energy loss processes, such as deep inelastic reactions. [S0556-2813(99)06009-4].
  •  
22.
  • Bruce, Louise C, et al. (författare)
  • A multi-lake comparative analysis of the General Lake Model (GLM) : Stress-testing across a global observatory network
  • 2018
  • Ingår i: Environmental Modelling & Software. - : Elsevier BV. - 1364-8152 .- 1873-6726. ; 102, s. 274-291
  • Tidskriftsartikel (refereegranskat)abstract
    • The modelling community has identified challenges for the integration and assessment of lake models due to the diversity of modelling approaches and lakes. In this study, we develop and assess a one-dimensional lake model and apply it to 32 lakes from a global observatory network. The data set included lakes over broad ranges in latitude, climatic zones, size, residence time, mixing regime and trophic level. Model performance was evaluated using several error assessment metrics, and a sensitivity analysis was conducted for nine parameters that governed the surface heat exchange and mixing efficiency. There was low correlation between input data uncertainty and model performance and predictions of temperature were less sensitive to model parameters than prediction of thermocline depth and Schmidt stability. The study provides guidance to where the general model approach and associated assumptions work, and cases where adjustments to model parameterisations and/or structure are required.
  •  
23.
  •  
24.
  • Drezner, J. A., et al. (författare)
  • International criteria for electrocardiographic interpretation in athletes: Consensus statement
  • 2017
  • Ingår i: Br J Sports Med. - : BMJ. - 0306-3674. ; 51:9, s. 704-731
  • Tidskriftsartikel (refereegranskat)abstract
    • Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly, advanced by a growing body of scientific data and investigations that both examine proposed criteria sets and establish new evidence to guide refinements. On 26-27 February 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington (USA), to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD.
  •  
25.
  • Dujon, B, et al. (författare)
  • The nucleotide sequence of Saccharomyces cerevisiae chromosome XV
  • 1997
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 387:6632, s. 98-102
  • Tidskriftsartikel (refereegranskat)abstract
    • Chromosome XV was one of the last two chromosomes of Saccharomyces cerevisiae to be discovered(1). It is the third-largest yeast chromosome after chromosomes XII and IV, and is very similar in size to chromosome VII. It alone represents 9% of the yeast genome (8% if ribosomal DNA is included). When systematic sequencing of chromosome XV was started, 93 genes or markers were identified, and most of them were mapped(2). However, very little else was known about chromosome XV which, in contrast to shorter chromosomes, had not been the object of comprehensive genetic or molecular analysis. It was therefore decided to start sequencing chromosome XV only in the third phase of the European Yeast Genome Sequencing Programme, after experience was gained on chromosomes III, XI and II (refs 3-5). The sequence of chromosome XV has been determined from a set of partly overlapping cosmid clones derived from a unique yeast strain, and physically mapped at 3.3-kilobase resolution before sequencing. As well as numerous new open reading frames (ORFs) and genes encoding tRNA or small RNA molecules, the sequence of 1,091,283 base pairs confirms the high proportion of orphan genes and reveals a number of ancestral and successive duplications with other yeast chromosomes.
  •  
26.
  •  
27.
  • Karlgren, Daniel, et al. (författare)
  • High-angular-momentum structures in Zn-64
  • 2004
  • Ingår i: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 69, s. 1-034330
  • Tidskriftsartikel (refereegranskat)abstract
    • High-angular-momentum states in Zn-64 were populated in the Ca-40(Si-28,4p) reaction at a beam energy of 122 MeV. Evaporated, light, charged particles were identified by the Microball, while gamma rays were detected using the Gammasphere array. The main focus of this paper is on two strongly coupled, collective bands. The yrast band, which was previously known, has been linked to lower-lying states establishing the excitation energies and angular momenta of in-band states for the first time. The newly identified excited band decays to the yrast band but firm angular-momentum assignments could not be made. In order to interpret these structures cranked-Nilsson-Strutinsky calculations have been performed. The calculations have been extended to account for the distribution of nucleons within a configuration. The yrast collective band is interpreted as based on the pi(f(7/2))(-1)(p(3/2)f(5/2))(2)(g(9/2))(1)nu(p(3/2)f(5/2))(4)(g(9/2))(2) configuration. There are several possible interpretations of the second band but it is difficult to distinguish between the different possibilities.
  •  
28.
  • Markidis, Stefano, et al. (författare)
  • NVIDIA tensor core programmability, performance & precision
  • 2018
  • Ingår i: Proceedings - 2018 IEEE 32nd International Parallel and Distributed Processing Symposium Workshops, IPDPSW 2018. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781538655559 ; , s. 522-531
  • Konferensbidrag (refereegranskat)abstract
    • The NVIDIA Volta GPU microarchitecture introduces a specialized unit, called Tensor Core that performs one matrix-multiply-and-accumulate on 4x4 matrices per clock cycle. The NVIDIA Tesla V100 accelerator, featuring the Volta microarchitecture, provides 640 Tensor Cores with a theoretical peak performance of 125 Tflops/s in mixed precision. In this paper, we investigate current approaches to program NVIDIA Tensor Cores, their performances and the precision loss due to computation in mixed precision. Currently, NVIDIA provides three different ways of programming matrix-multiply-and-accumulate on Tensor Cores: the CUDA Warp Matrix Multiply Accumulate (WMMA) API, CUTLASS, a templated library based on WMMA, and cuBLAS GEMM. After experimenting with different approaches, we found that NVIDIA Tensor Cores can deliver up to 83 Tflops/s in mixed precision on a Tesla V100 GPU, seven and three times the performance in single and half precision respectively. A WMMA implementation of batched GEMM reaches a performance of 4 Tflops/s. While precision loss due to matrix multiplication with half precision input might be critical in many HPC applications, it can be considerably reduced at the cost of increased computation. Our results indicate that HPC applications using matrix multiplications can strongly benefit from using of NVIDIA Tensor Cores.
  •  
29.
  • Mezza, D., et al. (författare)
  • Calibration methods for charge integrating detectors
  • 2022
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 1024
  • Tidskriftsartikel (refereegranskat)abstract
    • Since the introduction of the extremely intense X-ray free electron lasers, the need for low noise, high dynamic range and potentially fast charge integrating detectors has increased significantly. Among all the problems that research and development groups have to face in the development of such detectors, their calibration represents one of the most challenging and the collaboration between the detector development and user groups is of fundamental importance. The main challenge is to develop a calibration suite that is capable to test the detector over a wide dynamic range, with a high granularity and a very high linearity, together with a certain radiation tolerance and the possibility to well define the timings and the synchronization with the detector. Practical considerations have also to be made like the possibility to calibrate the detector in a reasonable time, the availability of the calibration source at the experimental place and so on. Such a calibration test suite is often not represented by a single source but by several sources that can cover different parts of the dynamic range and that need to be cross calibrated to have a final calibration curve. In this respect an essential part of the calibration is also to develop a mathematical model that allows calibrating the entire dynamic range, taking into account features that are calibration source and/or detector specific. The aim of this contribution is to compare the calibration for the AGIPD detector using several calibration sources such as internal current source, backside pulsing, IR pulsed laser, LED light and mono-energetic protons. The mathematical procedure used to calibrate the different sources will be discussed in great detail showing how to take into account a few shortcomings (like pixel coupling) that are common for many charge integrating detectors. This work has been carried out in the frame of the AGIPD project for the European X-ray Free Electron Laser. 
  •  
30.
  • Peng, I. B., et al. (författare)
  • Characterizing the performance benefit of hybrid memory system for HPC applications
  • 2018
  • Ingår i: Parallel Computing. - : Elsevier. - 0167-8191 .- 1872-7336. ; 76, s. 57-69
  • Tidskriftsartikel (refereegranskat)abstract
    • Heterogenous memory systems that consist of multiple memory technologies are becoming common in high-performance computing environments. Modern processors and accelerators, such as the Intel Knights Landing (KNL) CPU and NVIDIA Volta GPU, feature small-size high-bandwidth memory near the compute cores and large-size normal-bandwidth memory that is connected off-chip. Theoretically, HBM can provide about four times higher bandwidth than conventional DRAM. However, many factors impact the actual performance improvement that an application can achieve on such system. In this paper, we focus on the Intel KNL system and identify the most important factors on the application performance, including the application memory access pattern, the problem size, the threading level and the actual memory configuration. We use a set of representative applications from both scientific and data-analytics domains. Our results show that applications with regular memory access benefit from MCDRAM, achieving up to three times performance when compared to the performance obtained using only DRAM. On the contrary, applications with irregular memory access pattern are latency-bound and may suffer from performance degradation when using only MCDRAM. Also, we provide memory-centric analysis of four applications, identify their major data objects, correlate their characteristics to the performance improvement on the testbed.
  •  
31.
  •  
32.
  • Rondelet, A., et al. (författare)
  • Clathrin's adaptor interaction sites are repurposed to stabilize microtubules during mitosis
  • 2020
  • Ingår i: Journal of Cell Biology. - : Rockefeller University Press. - 0021-9525 .- 1540-8140. ; 219:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Clathrin ensures mitotic spindle stability and efficient chromosome alignment, independently of its vesicle trafficking function. Although clathrin localizes to the mitotic spindle and kinetochore fiber microtubule bundles, the mechanisms by which clathrin stabilizes microtubules are unclear. We show that clathrin adaptor interaction sites on clathrin heavy chain (CHC) are repurposed during mitosis to directly recruit the microtubule-stabilizing protein GTSE1 to the spindle. Structural analyses reveal that these sites interact directly with clathrin-box motifs on GTSE1. Disruption of this interaction releases GTSE1 from spindles, causing defects in chromosome alignment. Surprisingly, this disruption destabilizes astral microtubules, but not kinetochore-microtubule attachments, and chromosome alignment defects are due to a failure of chromosome congression independent of kinetochore-microtubule attachment stability. GTSE1 recruited to the spindle by clathrin stabilizes microtubules by inhibiting the microtubule depolymerase MCAK. This work uncovers a novel role of clathrin adaptor-type interactions to stabilize nonkinetochore fiber microtubules to support chromosome congression, defining for the first time a repurposing of this endocytic interaction mechanism during mitosis.
  •  
33.
  • Sharma, S., et al. (författare)
  • International Recommendations for Electrocardiographic Interpretation in Athletes
  • 2017
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097. ; 69:8, s. 1057-1075
  • Tidskriftsartikel (refereegranskat)abstract
    • Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural, or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly over the last decade; pushed by a growing body of scientific data that both tests proposed criteria sets and establishes new evidence to guide refinements. On February 26-27, 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington, to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD. (C) 2017 The Authors. Published by Elsevier Inc. on behalf of American College of Cardiology Foundation. All rights reserved.
  •  
34.
  • Sharma, S., et al. (författare)
  • International recommendations for electrocardiographic interpretation in athletes
  • 2018
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 39:16, s. 1466-1480
  • Tidskriftsartikel (refereegranskat)abstract
    • Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural, or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly over the last decade; pushed by a growing body of scientific data that both tests proposed criteria sets and establishes new evidence to guide refinements. On 26-27 February 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington, to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD.
  •  
35.
  •  
36.
  • Zicari, Roberto V., et al. (författare)
  • Co-design of a trustworthy AI system in healthcare : deep learning based skin lesion classifier
  • 2021
  • Ingår i: Frontiers in Human Dynamics. - : Frontiers Media S.A.. - 2673-2726. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper documents how an ethically aligned co-design methodology ensures trustworthiness in the early design phase of an artificial intelligence (AI) system component for healthcare. The system explains decisions made by deep learning networks analyzing images of skin lesions. The co-design of trustworthy AI developed here used a holistic approach rather than a static ethical checklist and required a multidisciplinary team of experts working with the AI designers and their managers. Ethical, legal, and technical issues potentially arising from the future use of the AI system were investigated. This paper is a first report on co-designing in the early design phase. Our results can also serve as guidance for other early-phase AI-similar tool developments.
  •  
37.
  • Zicari, Roberto V., et al. (författare)
  • On assessing trustworthy AI in healthcare : Machine learning as a supportive tool to recognize cardiac arrest in emergency calls
  • 2021
  • Ingår i: Frontiers in Human Dynamics. - : Frontiers Media S.A.. - 2673-2726. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • Artificial Intelligence (AI) has the potential to greatly improve the delivery of healthcare and other services that advance population health and wellbeing. However, the use of AI in healthcare also brings potential risks that may cause unintended harm. To guide future developments in AI, the High-Level Expert Group on AI set up by the European Commission (EC), recently published ethics guidelines for what it terms “trustworthy” AI. These guidelines are aimed at a variety of stakeholders, especially guiding practitioners toward more ethical and more robust applications of AI. In line with efforts of the EC, AI ethics scholarship focuses increasingly on converting abstract principles into actionable recommendations. However, the interpretation, relevance, and implementation of trustworthy AI depend on the domain and the context in which the AI system is used. The main contribution of this paper is to demonstrate how to use the general AI HLEG trustworthy AI guidelines in practice in the healthcare domain. To this end, we present a best practice of assessing the use of machine learning as a supportive tool to recognize cardiac arrest in emergency calls. The AI system under assessment is currently in use in the city of Copenhagen in Denmark. The assessment is accomplished by an independent team composed of philosophers, policy makers, social scientists, technical, legal, and medical experts. By leveraging an interdisciplinary team, we aim to expose the complex trade-offs and the necessity for such thorough human review when tackling socio-technical applications of AI in healthcare. For the assessment, we use a process to assess trustworthy AI, called 1Z-Inspection® to identify specific challenges and potential ethical trade-offs when we consider AI in practice.
  •  
38.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-38 av 38

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy