SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Weinmann Wolfgang) "

Sökning: WFRF:(Weinmann Wolfgang)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kip, Miriam Julia, et al. (författare)
  • The usefulness of direct ethanol metabolites in assessing alcohol intake in nonintoxicated male patients in an emergency room setting
  • 2008
  • Ingår i: Alcoholism: Clinical and Experimental Research. - : Wiley. - 0145-6008 .- 1530-0277. ; 32:7, s. 1284-1291
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: A major part of medical pathology in internal medicine is associated with chronic alcoholism. The aim of the current study was to investigate whether screening for Alcohol Use Disorders (AUD) can be improved through determination of direct ethanol metabolites compared to traditional biological state markers, the Alcohol Use Disorders Identification Test (AUDIT) and additional self-reports beyond the detection time period of a positive blood alcohol concentration (BAC). Methods: A total of 74 blood alcohol negative male patients who presented at the emergency room with either thoracic or gastrointestinal complaints were included. Phosphatidylethanol (PEth) was determined in whole blood, and ethyl glucuronide (EtG) in serum and urine samples. Traditional biological state markers [carbohydrate deficient transferrin (%CDT), gamma glutamyl transpeptidase (GGT), mean corpuscular volume (MCV)] were determined. The AUDIT was obtained and furthermore, all patients completed an additional self-report of alcohol consumption. Patients were divided into two (2) groups: AUDIT scores < 8 and AUDIT scores >= 8. Results: After assessment of the AUDIT, patients were allocated to one of the following groups: patients with AUDIT scores < 8 (n = 52) and with AUDIT scores >= 8 (n = 22). Twenty-five percent of the patients with AUDIT scores below the cut-off (n = 13/52) were tested positive for both PEth and UEtG. Of the patients who declared to be sober during the past 12 months, 38.5% were tested positive for PEth and UEtG. PEth discriminated similarly as %CDT for AUDIT scores >= 8 (AUC: 0.672; 95%CI 0.524 to 0.821). Self-reports of alcohol consumption were unreliable. Conclusion: Determination of direct ethanol metabolites such as PEth and UEtG provides additional evidence in screening for AUD in an ER setting. Determination of PEth might be considered complementary with or alternatively to %CDT.
  •  
2.
  • Wurst, Friedrich M, et al. (författare)
  • Characterization of Sialic Acid Index of Plasma Apolipoprotein J and Phosphatidylethanol During Alcohol Detoxification-A Pilot Study.
  • 2012
  • Ingår i: Alcoholism: Clinical and Experimental Research. - : Wiley. - 0145-6008. ; 36:2, s. 251-257
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Apolipoprotein J (ApoJ) is a component of plasma high-density lipoproteins. Previous studies have shown progressive recovery of ApoJ sialic acid content with increased duration of alcohol abstinence. Therefore, the sialic acid index of plasma apolipoprotein J (SIJ) seems to be a promising alcohol biomarker. Phosphatidylethanol (PEth) is a direct ethanol metabolite and has recently attracted attention as a biomarker of prolonged intake of higher amounts of alcohol. The aim of the pilot study was to explore sensitivity, specificity, and normalization of SIJ and PEth in comparison with traditional and emerging biomarkers. Methods: Five male alcohol-dependent patients (International Classification of Diseases 10, F 10.25) were included (median: 40 years old; Alcohol Use Disorders Identification Test value, 30; alcohol consumption in the previous 7 days, 1,680 g). SIJ, PEth, urinary ethyl glucuronide (UEtG), urinary ethyl sulfate (UEtS), and gamma glutamyl-transpeptidase (GGT) were determined at days 1, 3, 7, 10, 14, 21, and 28. Results: At study entry, SIJ, PEth, UEtG, and UEtS were positive in all subjects, whereas GGT and mean corpuscular volume were positive in 3 of 5 (60%) of the subjects. Individual SIJ levels increased between day 1 and 28 between 13.7 and 44.3%, respectively. For SIJ and PEth, the ANOVA (p < 0.005) showed a significant trend with the average subject's SIJ and PEth changing 1.22 and 1.02, respectively, per week. Conclusions: Our preliminary data suggest that SIJ and PEth might hold potential as markers of heavy ethanol intake.
  •  
3.
  • Wurst, Friedrich Martin, et al. (författare)
  • Measurement of direct ethanol metabolites suggests higher rate of alcohol use among pregnant women than found with the AUDIT : a pilot study in a population-based sample of Swedish women
  • 2008
  • Ingår i: American Journal of Obstetrics and Gynecology. - : Elsevier BV. - 0002-9378 .- 1097-6868. ; 198:4, s. 407.e1-
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: The objective of the study was to investigate whether biomarkers of alcohol consumption would provide additional information to the use of a validated alcohol questionnaire in pregnant women. STUDY DESIGN: One hundred three pregnant women were included in the study. The women completed the Alcohol Use Disorders Identification Test (AUDIT) questionnaire, and a urine and hair sample was collected. The urine samples were used for determination of ethyl glucuronide (EtG) and ethyl sulfate and the hair samples for EtG and fatty acid ethyl esters (FAEE). RESULTS: Twenty-six women (25.2%) were identified as possible alcohol consumers by the combined use of AUDIT and direct ethanol metabolites. Seven subjects had EtG or FAEE levels in hair highly suspicious of heavy drinking, but only 1 of these were positive according to the AUDIT questionnaire CONCLUSION: The combined use of the AUDIT questionnaire and direct ethanol metabolites appear to identify more potential alcohol consumers among pregnant women than does the sole use of the AUDIT questionnaire.
  •  
4.
  • Wurst, Friedrich Martin, et al. (författare)
  • Phosphatidylethanol: normalization during detoxification, gender aspects and correlation with other biomarkers and self-reports
  • 2010
  • Ingår i: Addiction Biology. - : Wiley. - 1369-1600 .- 1355-6215. ; 15:1, s. 88-95
  • Tidskriftsartikel (refereegranskat)abstract
    • Phosphatidylethanol (PEth) is a direct ethanol metabolite, and has recently attracted attention as biomarker of ethanol intake. The aims of the current study are: (1) to characterize the normalization time of PEth in larger samples than previously conducted; (2) to elucidate potential gender differences; and (3) to report the correlation of PEth with other biomarkers and self-reported alcohol consumption. Fifty-seven alcohol-dependent patients (ICD 10 F 10.25; 9 females, 48 males) entering medical detoxification at three study sites were enrolled. The study sample was comprised of 48 males and 9 females, with mean age 43.5. Mean gamma glutamyl transpeptidase (GGT) was 209.61 U/l, average mean corpuscular volume (MCV) was 97.35 fl, mean carbohydrate deficient transferrin (%CDT) was 8.68, and mean total ethanol intake in the last 7 days was 1653 g. PEth was measured in heparinized whole blood with a high-pressure liquid chromatography method, while GGT, MCV and %CDT were measured using routine methods. PEth levels at day 1 of detoxification ranged between 0.63 and 26.95 mu mol/l (6.22 mean, 4.70 median, SD 4.97). There were no false negatives at day 1. Sensitivities for the other biomarkers were 40.4% for MCV, 73.1% for GGT and 69.2% for %CDT, respectively. No gender differences were found for PEth levels at any time point. Our data suggest that PEth is (1) a suitable intermediate term marker of ethanol intake in both sexes; and (2) sensitivity is extraordinary high in alcohol dependent patients. The results add further evidence to the data that suggest that PEth has potential as a candidate for a sensitive and specific biomarker, which reflects longer-lasting intake of higher amounts of alcohol and seemingly has the above mentioned certain advantages over traditional biomarkers.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy