SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Weismann Constance Gesina) "

Sökning: WFRF:(Weismann Constance Gesina)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Broberg, Olof, et al. (författare)
  • Childhood Cancer Survivors Have Impaired Strain-Derived Myocardial Contractile Reserve by Dobutamine Stress Echocardiography
  • 2023
  • Ingår i: Journal of Clinical Medicine. - 2077-0383. ; 12:8, s. 1-14
  • Tidskriftsartikel (refereegranskat)abstract
    • Abnormal left ventricular contractile reserve (LVCR) is associated with adverse cardiac outcomes in different patient cohorts and might be useful in the detection of cardiomyopathy in childhood cancer survivors (CCS) after cardiotoxic treatment. The aim of this study was to evaluate LVCR by dobutamine stress echocardiography (DSE) combined with measures of myocardial strain in CCS previously treated with anthracyclines (AC). Fifty-three CCS (age 25.34 ± 2.44 years, 35 male) and 53 healthy controls (age 24.40 ± 2.40 years, 32 male) were included. Subjects were examined with echocardiography at rest, at low-dose (5 micrograms/kg/min), and at high-dose (40 micrograms/kg/min) dobutamine infusion. Left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS), strain rate (GSR), and early diastolic strain rate (GEDSR) at different DSE phases were used as measures of LVCR. The mean follow-up time among CCS was 15.8 ± 5.8 years. GLS, GSR, and LVEF were lower at rest in CCS compared to controls (p ≤ 0.03). LVEF was within the normal range in CCS. ΔGLS, ΔGSR, and ΔGEDSR but not ΔLVEF were lower in CCS compared to controls after both low- (p ≤ 0.048) and high-dose dobutamine infusion (p ≤ 0.023). We conclude that strain measures during low-dose DSE detect impaired myocardial contractile reserve in young CCS treated with AC at 15-year follow-up. Thus, DSE may help identify asymptomatic CCS at risk for heart failure and allows for tailored follow-up accordingly.
  •  
2.
  • Fricke, Katrin, et al. (författare)
  • Fetal Echocardiographic Dimension Indices: Important Predictors of Postnatal Coarctation
  • 2021
  • Ingår i: Pediatric Cardiology. - : Springer Science and Business Media LLC. - 0172-0643 .- 1432-1971. ; 42:3, s. 517-525
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the study is to identify reliable quantitative fetal echocardiographic predictors for postnatal development of coarctation (CoA). In this retrospective study, we included 65 fetuses with a prenatally suspected, isolated CoA, born 2010–2018. Dimensions of the cardiac structures, aortic, and ductal arches expressed as ratios and Z-scores were analyzed in relation to outcome. Fetuses that developed CoA postnatally (34%) exhibited significantly smaller Z-scores of left cardiac structures from the mitral valve to the aortic isthmus. The most sensitive and specific predictors were a carotid-subclavian artery index (CSAI) of < 0.78 (92.3% sensitivity, 96.8% specificity) or a product of isthmus-to-duct ratio in the three-vessel trachea view (3VT) and the mitral-to-tricuspid valve ratio (I/D3VTxMV/TV) of < 0.37 (100% sensitivity, 94.6% specificity). When comparing different Z-score datasets, we observed large and highly significant differences. Postnatal CoA can be predicted with high accuracy during fetal life using CSAI or I/D3VTxMV/TV. The latter may be particularly useful if adequate sagittal aortic arch images cannot be obtained. As significant and clinically unacceptable differences in Z-scores were observed for the same measurements, this calls for a large multi-center collaboration to generate reliable fetal echocardiographic Z-scores.
  •  
3.
  • Fricke, Katrin, et al. (författare)
  • Impact of Left Ventricular Morphology on Adverse Outcomes Following Stage 1 Palliation for Hypoplastic Left Heart Syndrome: 20 Years of National Data From Sweden
  • 2022
  • Ingår i: Journal of the American Heart Association. - : John Wiley & Sons. - 2047-9980. ; 11:7
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Hypoplastic left heart syndrome is associated with significant morbidity and mortality. We aimed to assess the influence of left ventricular morphology and choice of shunt on adverse outcome in patients with hypoplastic left heart syndrome and stage 1 palliation. METHODS AND RESULTS: This was a retrospective analysis of patients with hypoplastic left heart syndrome with stage 1 palliation between 1999 and 2018 in Sweden. Patients (n=167) were grouped based on the anatomic subtypes aortic-mitral atresia, aortic atresia-mitral stenosis (AA-MS), and aortic-mitral stenosis. The left ventricular phenotypes including globular left ventricle (Glob-LV), miniaturized and slit-like left ventricle (LV), and the incidence of major adverse events (MAEs) including mortality were assessed. The overall mortality and MAEs were 31% and 41%, respectively. AA-MS (35%) was associated with both mortality (all other subtypes versus AA-MS: interstage-I: hazard ratio [HR], 2.7; P=0.006; overall: HR, 2.2; P=0.005) and MAEs (HR, 2.4; P=0.0009). Glob-LV (57%), noticed in all patients with AA-MS, 61% of patients with aortic stenosis-mitral stenosis, and 19% of patients with aortic atresia-mitral atresia, was associated with both mortality (all other left ventricular phenotypes versus Glob-LV: interstage-I: HR, 4.5; P=0.004; overall: HR, 3.4; P=0.0007) and MAEs (HR, 2.7; P=0.0007). There was no difference in mortality and MAEs between patients with AA-MS and without AA-MS with Glob-LV (P>0.15). Patients with AA-MS (35%) or Glob-LV (38%) palliated with a Blalock-Taussig shunt had higher overall mortality compared with those palliated with Sano shunts, irrespective of the stage 1 palliation year (AA-MS: HR, 2.6; P=0.04; Glob-LV: HR, 2.1; P=0.03). CONCLUSIONS: Glob-LV and AA-MS are independent morphological risk factors for adverse short-and long-term outcome, especially if a Blalock-Taussig shunt is used as part of stage 1 palliation. These findings are important for the clinical management of patients with hypoplastic left heart syndrome.
  •  
4.
  • Sjöberg, Pia, et al. (författare)
  • Comparison of 2D and 4D Flow MRI in Neonates Without General Anesthesia
  • 2023
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 57:1, s. 71-82
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundNeonates with critical congenital heart disease require early intervention. Four-dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown.PurposeTo 1) validate two-dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows.Study TypePhantom and prospective patients.PopulationA total of 17 neonates with surgically corrected aortic coarctation (age 18 days [IQR 11–20]) and a three-dimensional printed neonatal aorta phantom.Field Strength/SequenceA 5 T, 2D flow and 4D flow.AssessmentIn the phantom, 2D and 4D flow volumes (ascending and descending aorta, and aortic arch vessels) with different resolutions were compared to high-resolution reference 2D flow. In neonates, 4D flow was compared to 2D flow volumes at each vessel. Internal consistency was computed as the flow volume in the ascending aorta minus the sum of flow volumes in the aortic arch vessels and descending aorta, divided by ascending aortic flow.Statistical testsBland–Altman plots, Pearson correlation coefficient (r), and Student's t-tests.ResultsIn the phantom, 2D flow differed by 0.01 ± 0.02 liter/min with 1.5 mm spatial resolution and −0.01 ± 0.02 liter/min with 0.8 mm resolution; 4D flow differed by −0.05 ± 0.02 liter/min with 2.4 mm spatial and 42 msec temporal resolution, −0.01 ± 0.02 liter/min with 1.5 mm, 42 msec resolution and −0.01 ± 0.02 liter/min with 1.5 mm, 21 msec resolution. In patients, 4D flow and 2D flow differed by −0.06 ± 0.08 liter/min. Internal consistency in patients was −11% ± 17% for 2D flow and 5% ± 13% for 4D flow. Scan time was 17.1 minutes [IQR 15.5–18.5] for 2D flow and 6.2 minutes [IQR 5.3–6.9] for 4D flow, P < 0.0001.Data ConclusionNeonatal 4D flow MRI is time efficient and can be acquired with good internal consistency without contrast agents or general anesthesia, thus potentially expanding 4D flow use to the youngest and smallest patients.Evidence Level1Technical EfficacyStage 2
  •  
5.
  •  
6.
  • Weismann, Constance Gesina, et al. (författare)
  • Electrocardiographic proarrhythmic changes in pregnancy of women with CHD
  • Ingår i: Cardiology in the Young. - 1467-1107.
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives:Pregnancy-related physiological adaptations result in increased heart rate as well as electrocardiographic changes such as a mean QTc prolongation of 27 ms. Pregnant women with CHD are at increased risk for cardiovascular complications. The aim of this study was to identify risk factors for abnormally prolonged QTc interval—a risk factor for ventricular arrhythmias—in pregnant women with CHD.Material and method:Retrospective longitudinal single-centre study. Pre-pregnancy demographic and electrocardiographic risk factors for abnormal QTc duration during pregnancy of (a) > 460 ms and (b) >27 ms increase were analyzed.Results:Eighty-three pregnancies in 63 women were included, of which three had documented arrhythmias. All five Modified World Health Organization Classification of Maternal Cardiovascular Risk (mWHO) classes were represented, with 15 pregnancies (18.1%) in mWHO class I, 26 (31.3%) in mWHO II, 28 (33.7%) in mWHO II-III, 11 (13.3%) in mWHO III, and three pregnancies (3.6%) in mWHO class IV. Heart rate and QTc interval increased, while QRS duration and PR interval shortened during pregnancy. QTc duration of > 460 ms was associated with increased pre-pregnancy QTc interval, QRS duration, and weight, as well as body mass index. QTc increase of > 27 ms was associated with increased heart rate prior to pregnancy. No significant associations of electrocardiographic changes with mWHO class or CHD type were identified.Conclusion:Increased QTc in pregnant women with CHD was associated with being overweight or having higher heart rate, QRS, or QTc duration prior to pregnancy. These patients should be monitored closely for arrhythmias during pregnancy.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy