SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Whitley R. J.) "

Sökning: WFRF:(Whitley R. J.)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abdesselam, A., et al. (författare)
  • The ATLAS semiconductor tracker end-cap module
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 575:3, s. 353-389
  • Tidskriftsartikel (refereegranskat)abstract
    • The challenges for the tracking detector systems at the LHC are unprecedented in terms of the number of channels, the required read-out speed and the expected radiation levels. The ATLAS Semiconductor Tracker. (SCT) end-caps have a total of about 3 million electronics channels each reading out every 25 ns into its own on-chip 3.3 mu s buffer. The highest anticipated dose after 10 years operation is 1.4x10(14) cm(-2) in units of 1 MeV neutron equivalent (assuming the damage factors scale with the non-ionising energy loss). The forward tracker has 1976 double-sided modules, mostly of area similar to 70 cm(2), each having 2 x 768 strips read out by six ASICs per side. The requirement to achieve an average perpendicular radiation length of 1.5% X-0, while coping with up to 7 W dissipation per module (after irradiation), leads to stringent constraints on the thermal design. The additional requirement of 1500e(-) equivalent noise charge (ENC) rising to only 1800e(-) ENC after irradiation, provides stringent design constraints on both the high-density Cu/Polyimide flex read-out circuit and the ABCD3TA read-out ASICs. Finally, the accuracy of module assembly must not compromise the 16 mu m (r phi) resolution perpendicular to the strip directions or 580 mu m radial resolution coming from the 40 mrad front-back stereo angle. A total of 2210 modules were built to the tight tolerances and specifications required for the SCT. This was 234 more than the 1976 required and represents a yield of 93%. The component flow was at times tight, but the module production rate of 40-50 per week was maintained despite this. The distributed production was not found to be a major logistical problem and it allowed additional flexibility to take advantage of where the effort was available, including any spare capacity, for building the end-cap modules. The collaboration that produced the ATLAS SCT end-cap modules kept in close contact at all times so that the effects of shortages or stoppages at different sites could be rapidly resolved.
  •  
2.
  •  
3.
  • Gnann, J. W., et al. (författare)
  • Herpes Simplex Encephalitis: Lack of Clinical Benefit of Long-term Valacyclovir Therapy
  • 2015
  • Ingår i: Clinical Infectious Diseases. - : Oxford University Press (OUP). - 1058-4838 .- 1537-6591. ; 61:5, s. 683-691
  • Tidskriftsartikel (refereegranskat)abstract
    • Background. Despite the proven efficacy of acyclovir (ACV) therapy, herpes simplex encephalitis (HSE) continues to cause substantial morbidity and mortality. Among patients with HSE treated with ACV, the mortality rate is approximately 14%-19%. Among survivors, 45%-60% have neuropsychological sequelae at 1 year. Thus, improving therapeutic approaches to HSE remains a high priority. Methods. Following completion of a standard course of intravenous ACV, 87 adult patients with HSE (confirmed by positive polymerase chain reaction [PCR] for herpes simplex virus DNA in cerebrospinal fluid) were randomized to receive either valacyclovir (VACV) 2 g thrice daily (n = 40) or placebo tablets (n = 47) for 90 days (12 tablets of study medication daily). The primary endpoint was survival with no or mild neuropsychological impairment at 12 months, as measured by the Mattis Dementia Rating Scale (MDRS). Logistic regression was utilized to assess factors related to the primary endpoint. Results. The demographic characteristics of the 2 randomization groups were statistically similar with no significant differences in age, sex, or race. At 12 months, there was no significant difference in the MDRS scoring for VACV-treated vs placebo recipients, with 85.7% and 90.2%, respectively, of patients demonstrating no or mild neuropsychological impairment (P = .72). No significant study-related adverse events were encountered in either treatment group. Conclusions. Following standard treatment with intravenous ACV for PCR-confirmed HSE, an additional 3-month course of oral VACV therapy did not provide added benefit as measured by neuropsychological testing 12 months later in a population of relatively high-functioning survivors.
  •  
4.
  •  
5.
  • Williams, Edward H, et al. (författare)
  • CamGFR v2: A New Model for Estimating the Glomerular Filtration Rate from Standardized or Non-standardized Creatinine in Patients with Cancer.
  • 2021
  • Ingår i: Clinical cancer research : an official journal of the American Association for Cancer Research. - 1557-3265. ; 27:5, s. 1381-1390
  • Tidskriftsartikel (refereegranskat)abstract
    • Management of patients with cancer, specifically carboplatin dosing, requires accurate knowledge of glomerular filtration rate (GFR). Direct measurement of GFR is resource limited. Available models for estimated GFR (eGFR) are optimized for patients without cancer and either isotope dilution mass spectrometry (IDMS)- or non-IDMS-standardized creatinine measurements. We present an eGFR model for patients with cancer compatible with both creatinine measurement methods.GFR measurements, biometrics, and IDMS- or non-IDMS-standardized creatinine values were collected for adult patients from three cancer centers. Using statistical modeling, an IDMS and non-IDMS creatinine-compatible eGFR model (CamGFR v2) was developed. Its performance was compared with that of the existing models Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI), Modification of Diet in Renal Disease (MDRD), Full Age Spectrum (FAS), Lund-Malmö revised, and CamGFR v1, using statistics for bias, precision, accuracy, and clinical robustness.A total of 3,083 IDMS- and 4,612 non-IDMS-standardized creatinine measurements were obtained from 7,240 patients. IDMS-standardized creatinine values were lower than non-IDMS-standardized values in within-center comparisons (13.8% lower in Cambridge; P < 0.0001 and 19.3% lower in Manchester; P < 0.0001), and more consistent between centers. CamGFR v2 was the most accurate [root-mean-squared error for IDMS, 14.97 mL/minute (95% confidence interval, 13.84-16.13) and non-IDMS, 15.74 mL/minute (14.86-16.63)], most clinically robust [proportion with >20% error of calculated carboplatin dose for IDMS, 0.12 (0.09-0.14) and non-IDMS, 0.17 (0.15-0.2)], and least biased [median residual for IDMS, 0.73 mL/minute (-0.68 to 2.2) and non-IDMS, -0.43 mL/minute (-1.48 to 0.91)] eGFR model, particularly when eGFR was larger than 60 ml/minute.CamGFR v2 can utilize IDMS- and non-IDMS-standardized creatinine measurements and outperforms previous models. CamGFR v2 should be examined prospectively as a practice-changing standard of care for eGFR-based carboplatin dosing.
  •  
6.
  •  
7.
  •  
8.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy