SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wikh R) "

Sökning: WFRF:(Wikh R)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andersson, Bert, 1952, et al. (författare)
  • Early changes in longitudinal performance predict future improvement in global left ventricular function during long term beta adrenergic blockade.
  • 2000
  • Ingår i: Heart (British Cardiac Society). - 1468-201X. ; 84:6, s. 599-605
  • Tidskriftsartikel (refereegranskat)abstract
    • Contraction of longitudinal and subendocardial myocardial muscle fibres is reflected in descent of the atrioventricular (AV) plane. The aim was therefore to determine whether beta blocker treatment with prolongation of diastole might result in improved function as reflected by AV plane movements in patients with chronic heart failure.Double blind, randomised, placebo controlled and open intervention study.University hospital.Patients with congestive heart failure: placebo controlled (n = 26) and an open protocol (n = 15).12 months of metoprolol treatment.Short axis and long axis echocardiography, invasive haemodynamics, radionuclide angiography.Recovery of systolic and diastolic function during metoprolol treatment was reflected by early changes in mean (SD) AV plane amplitude, from 5.3 (2.0)% to 7.1 (3.2)% and 7.8 (3. 1)% (at 3 and 12 months, respectively; p < 0.05). In a multivariate analysis, only the change in AV plane amplitude by three months was independently associated with improvement in pulmonary capillary wedge pressure by six months (r = 0.80, p = 0.017). Change in AV plane amplitude by three months was also a better predictor of improvement in ejection fraction by 12 months (r = 0.78, p < 0.001) than changes in radionuclide ejection fraction by three months (r = 0.34, p = 0.049).Improvement in longitudinal contraction was closely associated with a decrease in left ventricular filling pressure during metoprolol treatment. This association was stronger than changes in short axis performance or radionuclide ejection fraction, emphasising the importance of AV plane motion for left ventricular filling and systolic performance in patients with heart failure.
  •  
2.
  • Caidahl, Kenneth, 1949, et al. (författare)
  • New concept in echocardiography: harmonic imaging of tissue without use of contrast agent.
  • 1998
  • Ingår i: Lancet (London, England). - : Elsevier BV. - 0140-6736. ; 352:9136, s. 1264-70
  • Tidskriftsartikel (refereegranskat)abstract
    • Endocardial border detection is important for echocardiographic assessment of left-ventricular function. Second harmonic imaging of contrast agents enhances this border detection. We discovered that harmonic imaging improves tissue visualisation even before contrast injection. We therefore sought objectively to demonstrate the degree of enhancement of endocardial and myocardial visualisation.An ATL HDI-3000 scanner with software for contrast harmonic imaging was used to record short-axis images of the left ventricle in 27 patients with possible myocardial disease and 22 controls, in the fundamental mode and with harmonic imaging. A computer program measured the relative grey-scale values within six segments of the endocardium and myocardium. An Acuson Sequoia scanner equipped with software for tissue harmonic imaging was used to investigate the reproducibility of ejection-fraction calculations in 22 patients with ischaemic heart disease.Harmonic imaging produced brighter endocardium within each segment. Relative to the mean grey value of the total imaging sector, the values for harmonic and fundamental imaging were 171.5 vs 85.6% (p<0.0001) in end diastole and 194.1 vs 106.7% (p<0.0001) in end systole. Results for the myocardial segments were also significantly better for harmonic imaging. Structure enhancement of similar magnitude was seen among patients and healthy controls. Use of harmonic imaging reduced the proportion of unacceptable images by 14-46% in different views and improved the reproducibility of biplane ejection-fraction measurements.In comparison with fundamental imaging, the relative endocardial and myocardial brightness is enhanced by harmonic imaging.
  •  
3.
  • Guron, Cecilia Wallentin, 1965, et al. (författare)
  • Can the left ventricular early diastolic tissue-to-blood time interval be used to identify a normal pulmonary capillary wedge pressure?
  • 2007
  • Ingår i: Eur J Echocardiogr. - : Oxford University Press (OUP). - 1525-2167. ; 8:2, s. 94-101
  • Tidskriftsartikel (refereegranskat)abstract
    • The pulsed Doppler early diastolic left ventricular (LV) tissue (e)-blood (E) onset temporal relationship (e-E) is suggested to predict pulmonary capillary wedge pressure (PCWP), through the formulas: tau = 32 + 0.7(e-E) and PCWP = LV end-systolic pressure x e(-IVRT/tau). Small changes/errors in E could influence the quotient IVRT/tau by oppositely affecting IVRT and e-E. At rest in 50 healthy individuals we noted: e-E: 2 +/- 14 ms; IVRT: 89 +/- 17 ms; calculated tau: 33 +/- 10 ms; and PCWP: 9 +/- 9 mmHg (> 12 mmHg in 28%). Non-pharmacological preload alterations in 14 individuals rendered an intraindividual 'PCWP'-fluctuation of up to 40 mmHg. This application may therefore not be clinically robust.
  •  
4.
  • Guron, Cecilia Wallentin, 1965, et al. (författare)
  • The E/e filling index and right ventricular pressure in relation to applied international Doppler recommendations of left ventricular filling assessment
  • 2005
  • Ingår i: Eur J Echocardiogr. - : Oxford University Press (OUP). - 1525-2167. ; 6:6, s. 419-28
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: A ratio>15 between the early diastolic pulsed Doppler velocities of the mitral inflow (E) and the basal left ventricular (LV) tissue (e) has been demonstrated to predict an elevated LV filling pressure (FP). An elevated LVFP implies an elevated right ventricular pressure (RVp). In order to investigate the sensitivity of the E/e filling index, we compared E/e and RVp, in their ability to identify a Doppler-assumed elevation of LVFP. METHODS AND RESULTS: Application of pulsed Doppler international recommendations grouped 134 patients with acute coronary syndromes (ACS) and 50 age- and sex-matched controls, according to LV filling: normal; delayed relaxation; an isolated pathological mitral-pulmonary venous-A-wave-duration difference; pseudo normal; or a restrictive filling pattern. An E/e>15 and an RVp>30 mmHg showed the following (%) sensitivity (32/94), specificity (95/76), positive (68/59), and negative (80/97) predictive values of a Doppler-assumed elevation of LVFP, in terms of either a pseudo normal or a restrictive filling pattern. CONCLUSION: The low sensitivity of E/e to detect a Doppler-assumed elevation of LVFP could limit its clinical usefulness as a single variable, in ACS. The high sensitivity and negative predictive value of RVp support its use as an additional LV filling variable in these patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy