SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Willumeit Römer Regine) "

Sökning: WFRF:(Willumeit Römer Regine)

  • Resultat 1-13 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Galli, Silvia, et al. (författare)
  • Evaluation of the degradation behavior of resorbable metal implants for in vivo osteosynthesis by synchrotron radiation based x-ray tomography and histology
  • 2016
  • Ingår i: Developments in X-Ray Tomography X. - : SPIE - International Society for Optical Engineering.
  • Konferensbidrag (refereegranskat)abstract
    • Magnesium(Mg)-alloys are promising candidates as temporary implants for orthopedic and cranio-facial applications. They can sustain tissues during healing, thanks to favorable mechanical properties, and then they slowly degrade into biocompatible products, avoiding the need of a second surgery for implant removal. They have the potential to benefit a vast number of patients, especially children and elderly patients. However, to be able to tailor their degradation to match the speed of tissue regeneration it is crucial to understand how they actually degrade in the living organism. We utilized high-resolution synchrotron-based tomography at the beamline P05 operated by HZG at the storage ring PETRA III at DESY to study the degradation of 3 novel Mg-alloys in rat bone and the consequent bone response. On three-dimensional reconstructions of the bone-implant explants we were able to follow the dynamic transformation that the materials underwent at different healing times and on the basis of absorption coefficients we could distinguish and quantify the amount of remaining implants, the corrosion layers and the new bone. This was a great advantage compared to laboratory CT, for which the limitation in contrast and in resolution made impossible to discriminate between original alloy, degradation products and bone, leading to inaccurate determination of the materials degradation rates. The same samples imaged by tomography were used for non-decalcified histology. The combination of histological and tomographical images provided new insight on the nature of the bone-to-implant interface and of the degradation products, which appeared to have great similarities to the host bone.
  •  
2.
  • Moosmann, Julian, et al. (författare)
  • A load frame for in situ tomography at PETRA III
  • 2019
  • Ingår i: Developments in X-Ray Tomography XII. - : SPIE. - 0277-786X .- 1996-756X. - 9781510629196 ; 11113
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • A load frame for in situ mechanical testing is developed for the microtomography end stations at the imaging beamline P05 and the high-energy material science beamline P07 of PETRA III at DESY, both operated by the Helmholtz- Zentrum Geesthacht. The load frame is fully integrated into the beamline control system and can be controlled via a feedback loop. All relevant parameters (load, displacement, temperature, etc.) are continuously logged. It can be operated in compression or tensile mode applying forces of up to 1 kN and is compatible with all contrast modalities available at IBL and HEMS i.e. conventional attenuation contrast, propagation based phase contrast and differential phase contrast using a grating interferometer. The modularity and flexibility of the load frame allows conducting a wide range of experiments. E.g. compression tests to understand the failure mechanisms in biodegradable implants in rat bone or to investigate the mechanics and kinematics of the tessellated cartilage skeleton of sharks and rays, or tensile tests to illuminate the structure-property relationship in poplar tension wood or to visualize the 3D deformation of the tendonbone insertion. We present recent results from the experiments described including machine-learning driven volume segmentation and digital volume correlation of load tomography sequences.
  •  
3.
  • Moosmann, Julian, et al. (författare)
  • Biodegradable magnesium-based implants in bone studied by synchrotron radiation microtomography
  • 2017
  • Ingår i: Developments in X-Ray Tomography XI. - : SPIE - International Society for Optical Engineering. ; 10391
  • Konferensbidrag (refereegranskat)abstract
    • Permanent implants made of titanium or its alloys are the gold standard in many orthopedic and traumatological applications due to their good biocompatibility and mechanical properties. However, a second surgical intervention is required for this kind of implants as they have to be removed in the case of children that are still growing or on patient's demand. Therefore, magnesium-based implants are considered for medical applications as they are degraded under physiological conditions. The major challenge is tailoring the degradation in a manner that is suitable for a biological environment and such that stabilization of the bone is provided for a controlled period. In order to understand failure mechanisms of magnesium-based implants in orthopedic applications and, further, to better understand the osseointegration, screw implants in bone are studied under mechanical load by means of a push-out device installed at the imaging beamline P05 of PETRA III at DESY. Conventional absorption contrast microtomography and phasecontrast techniques are applied in order to monitor the bone-to-implant interface under increasing load conditions. In this proof-of-concept study, first results from an in situ push-out experiment are presented.
  •  
4.
  • Peruzzi, Niccolò, et al. (författare)
  • Multimodal ex vivo methods reveal that Gd-rich corrosion byproducts remain at the implant site of biodegradable Mg-Gd screws
  • 2021
  • Ingår i: Acta Biomaterialia. - : Elsevier. - 1742-7061 .- 1878-7568. ; 136, s. 582-591
  • Tidskriftsartikel (refereegranskat)abstract
    • Extensive research is being conducted on magnesium (Mg) alloys for bone implant manufacturing, due to their biocompatibility, biodegradability and mechanical properties. Gadolinium (Gd) is among the most promising alloying elements for property control in Mg alloy implants; however, its toxicity is controversial. Investigating Gd behavior during implant corrosion is thus of utmost importance. In this study, we analyzed the degradation byproducts at the implant site of biodegradable Mg-5Gd and Mg-10Gd implants after 12 weeks healing time, using a combination of different imaging techniques: histology, energy-dispersive x-ray spectroscopy (EDX), x-ray microcomputed tomography (µCT) and neutron µCT. The main finding has been that, at the healing time in exam, the corrosion appears to have involved only the Mg component, which has been substituted by calcium and phosphorus, while the Gd remains localized at the implant site. This was observed in 2D by means of EDX maps and extended to 3D with a novel application of neutron tomography. X-ray fluorescence analysis of the main excretory organs also did not reveal any measurable accumulation of Gd, further reinforcing the conclusion that very limited or no removal at all of Gd-alloy happened during degradation.
  •  
5.
  • Raj, Akanksha, et al. (författare)
  • Lubrication synergy : Mixture of hyaluronan and dipalmitoylphosphatidylcholine (DPPC) vesicles
  • 2017
  • Ingår i: Journal of Colloid and Interface Science. - : Elsevier BV. - 0021-9797 .- 1095-7103. ; 488, s. 225-233
  • Tidskriftsartikel (refereegranskat)abstract
    • Phospholipids and hyaluronan have been implied to fulfil important roles in synovial joint lubrication. Since both components are present in synovial fluid, self-assembly structures formed by them should also be present. We demonstrate by small angle X-ray scattering that hyaluronan associates with the outer shell of dipalmitoylphophatidylcholine (DPPC) vesicles in bulk solution. Further, we follow adsorption to silica from mixed hyaluronan/DPPC vesicle solution by Quartz Crystal Microbalance with Dissipation measurements. Atomic Force Microscope imaging visualises the adsorbed layer structure consisting of non-homogeneous phospholipid bilayer with hyaluronan/DPPC aggregates on top. The presence of these aggregates generates a long-range repulsive surface force as two such surfaces are brought together. However, the aggregates are easily deformed, partly rearranged into multilayer structures and partly removed from between the surfaces under high loads. These layers offer very low friction coefficient (<0.01), high load bearing capacity (≈23 MPa), and self-healing ability. Surface bound DPPC/hyaluronan aggregates provide a means for accumulation of lubricating DPPC molecules on sliding surfaces.
  •  
6.
  •  
7.
  • Wang, Min, et al. (författare)
  • The effect of temperature on supported dipalmitoylphosphatidylcholine (DPPC) bilayers : Structure and lubrication performance
  • 2015
  • Ingår i: Journal of Colloid and Interface Science. - : Elsevier BV. - 0021-9797 .- 1095-7103. ; 445, s. 84-92
  • Tidskriftsartikel (refereegranskat)abstract
    • Phospholipids fulfill an important role in joint lubrication. They, together with hyaluronan and glycoproteins, are the biolubricants that sustain low friction between cartilage surfaces bathed in synovial fluid. In this work we have investigated how the friction force and load bearing capacity of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) bilayers on silica surfaces are affected by temperature, covering the temperature range 25–52 °C. Friction forces have been determined utilizing the AFM colloidal probe technique, which showed that DPPC bilayers are able to provide low friction forces over the whole temperature interval. However, the load bearing capacity is improved at higher temperatures. We interpret this finding as being a consequence of lower rigidity and higher self-healing capacity of the DPPC bilayer in the liquid disordered state compared to the gel state. The corresponding structure of solid supported DPPC bilayers at the silica–liquid interface has been followed using X-ray reflectivity measurements, which suggests that the DPPC bilayer is in the gel phase at 25 °C and 39 °C and in the liquid disordered state at 55 °C. Well-defined bilayer structures were observed for both phases. The deposited DPPC bilayers were also imaged using AFM PeakForce Tapping mode, and these measurements indicated a less homogeneous layer at temperatures below 37 °C.
  •  
8.
  • Willumeit-Römer, Regine, et al. (författare)
  • Visualization of Implant Failure by Synchrotron Tomography
  • 2018
  • Ingår i: TMS 2018 147th Annual Meeting &amp; Exhibition Supplemental Proceedings. - Cham : Springer. - 9783319725253 - 9783319725260 ; , s. 275-284
  • Konferensbidrag (refereegranskat)abstract
    • Magnesium (Mg) and its alloys degrade under physiological conditions. But how strong is the connection between the implant, the corrosion layer and the surrounding tissue, namely bone? Biomechanical tests like push-out tests have shown that a degraded Mg-pin is surprisingly well integrated with the bone “as reported by Castellani et al. (Acta Biomater 7(1):432–440, 2011) [1]”. High-resolution synchrotron tomography offers a deep look into the microstructure of the material as well as of the bone during deformation until fracture happens. Here we present first data from an in situ tomography experiment of a biodegradable Mg-based implant under compressive load showing how Mg implants are incorporated into bone.
  •  
9.
  • Zander, Thomas, et al. (författare)
  • Influence of high hydrostatic pressure on solid supported DPPC bilayers with hyaluronan in the presence of Ca2+ ions
  • 2019
  • Ingår i: Soft Matter. - : Royal Society of Chemistry. - 1744-683X .- 1744-6848. ; 15:36, s. 7295-7304
  • Tidskriftsartikel (refereegranskat)abstract
    • The molecular mechanisms responsible for outstanding lubrication of natural systems, like articular joints, have been the focus of scientific research for several decades. One essential aspect is the lubrication under pressure, where it is important to understand how the lubricating entities adapt under dynamic working conditions in order to fulfill their function. We made a structural investigation of a model system consisting of two of the molecules present at the cartilage interface, 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and hyaluronan, at high hydrostatic pressure. Phospholipid layers are found at the cartilage surfaces and are able to considerably reduce friction. Their behavior under load and varied solution conditions is important as pressures of 180 bar are encountered during daily life activities. We focus on how divalent ions, like Ca2+, affect the interaction between DPPC and hyaluronan, as other investigations have indicated that calcium ions influence their interaction. It could be shown that already low amounts of Ca2+ strongly influence the interaction of hyaluronan with DPPC. Our results suggest that the calcium ions increase the amount of adsorbed hyaluronan indicating an increased electrostatic interaction. Most importantly, we observe a modification of the DPPC phase diagram as hyaluronan absorbs to the bilayer which results in an Lα-like structure at low temperatures and a decoupling of the leaflets forming an asymmetric bilayer structure.
  •  
10.
  • Zander, Thomas, et al. (författare)
  • Influence of the Molecular Weight and the Presence of Calcium Ions on the Molecular Interaction of Hyaluronan and DPPC
  • 2020
  • Ingår i: Molecules. - : NLM (Medline). - 1431-5157 .- 1420-3049. ; 25:17
  • Tidskriftsartikel (refereegranskat)abstract
    • Hyaluronan is an essential physiological bio macromolecule with different functions. One prominent area is the synovial fluid which exhibits remarkable lubrication properties. However, the synovial fluid is a multi-component system where different macromolecules interact in a synergetic fashion. Within this study we focus on the interaction of hyaluronan and phospholipids, which are thought to play a key role for lubrication. We investigate how the interactions and the association structures formed by hyaluronan (HA) and 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) are influenced by the molecular weight of the bio polymer and the ionic composition of the solution. We combine techniques allowing us to investigate the phase behavior of lipids (differential scanning calorimetry, zeta potential and electrophoretic mobility) with structural investigation (dynamic light scattering, small angle scattering) and theoretical simulations (molecular dynamics). The interaction of hyaluronan and phospholipids depends on the molecular weight, where hyaluronan with lower molecular weight has the strongest interaction. Furthermore, the interaction is increased by the presence of calcium ions. Our simulations show that calcium ions are located close to the carboxylate groups of HA and, by this, reduce the number of formed hydrogen bonds between HA and DPPC. The observed change in the DPPC phase behavior can be attributed to a local charge inversion by calcium ions binding to the carboxylate groups as the binding distribution of hyaluronan and 1,2-dipalmitoyl-sn-glycero-3-phosphocholine is not changed.
  •  
11.
  • Zander, Thomas, et al. (författare)
  • The influence of hyaluronan on the structure of a DPPC-bilayer under high pressures
  • 2016
  • Ingår i: Colloids and Surfaces B. - : Elsevier. - 0927-7765 .- 1873-4367. ; 142, s. 230-238
  • Tidskriftsartikel (refereegranskat)abstract
    • The superior lubrication properties of synovial joints have inspired many studies aiming at uncovering the molecular mechanisms which give rise to low friction and wear. However, the mechanisms are not fully understood yet, and, in particular, it has not been elucidated how the biolubricants present at the interface of cartilage respond to high pressures, which arise during high loads of joints. In this study we utilize a simple model system composed of two biomolecules that have been implied as being important for joint lubrication. It consists of a solid supported dipalmitoylphosphatidylcholin (DPPC) bilayer, which was formed via vesicles fusion on a flat Si wafer, and the anionic polysaccharide hyaluronan (HA). We first characterized the structure of the HA layer that adsorbed to the DPPC bilayers at ambient pressure and different temperatures using X-ray reflectivity (XRR) measurements. Next, XRR was utilized to evaluate the response of the system to high hydrostatic pressures, up to 2 kbar (200 MPa), at three different temperatures. By means of fluorescence microscopy images the distribution of DPPC and HA on the surface was visualized. Our data suggest that HA adsorbs to the headgroup region that is oriented towards the water side of the supported bilayer. Phase transitions of the bilayer in response to temperature and pressure changes were also observed in presence and absence of HA. Our results reveal a higher stability against high hydrostatic pressures for DPPC/HA composite layers compared to that of the DPPC bilayer in absence of HA.
  •  
12.
  • Zeller-Plumhoff, Berit, et al. (författare)
  • Nanotomographic evaluation of precipitate structure evolution in a Mg-Zn-Zr alloy during plastic deformation
  • 2020
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 10:1, s. 16101-16101
  • Tidskriftsartikel (refereegranskat)abstract
    • Magnesium and its alloys attract increasingly wide attention in various fields, ranging from transport to medical solutions, due to their outstanding structural and degradation properties. These properties can be tailored through alloying and thermo-mechanical processing, which is often complex and multi-step, thus requiring in-depth analysis. In this work, we demonstrate the capability of synchrotron-based nanotomographic X-ray imaging methods, namely holotomography and transmission X-ray microscopy, for the quantitative 3D analysis of the evolution of intermetallic precipitate (particle) morphology and distribution in magnesium alloy Mg-5.78Zn-0.44Zr subjected to a complex multi-step processing. A rich history of variation of the intermetallic particle structure in the processed alloy provided a testbed for challenging the analytical capabilities of the imaging modalities studied. The main features of the evolving precipitate structure revealed earlier by traditional light and electron microscopy methods were confirmed by the 3D techniques of synchrotron-based X-ray imaging. We further demonstrated that synchrotron-based X-ray imaging enabled uncovering finer details of the variation of particle morphology and number density at various stages of processing-above and beyond the information provided by visible light and electron microscopy.
  •  
13.
  • Zeller-Plumhoff, Berit, et al. (författare)
  • Oxygen-sensitive nanoparticles reveal the spatiotemporal dynamics of oxygen reduction during magnesium implant biodegradation
  • 2022
  • Ingår i: npj Materials Degradation. - : Springer Science and Business Media LLC. - 2397-2106. ; 6:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Magnesium (Mg) alloys are becoming increasingly important in the biomedical field as temporary bone implants. However, the biodegradation process of Mg alloys is highly complex and recent findings suggest that oxygen (O2) consumption is non-negligible. In this study, we give experimental proof of O2 consumption during Mg degradation under physiological conditions. Specifically, we study pure Mg, Mg–6 wt%Ag and Mg–5 wt%Gd in Hanks’ balanced salt solution and Dulbecco’s modified Eagle’s medium. We show that O2 consumption and hydrogen evolution are inversely correlated and that O2 concentrations remain below 7.5% in certain cases, which could have significant implications for bone healing.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-13 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy