SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Worster A.) "

Sökning: WFRF:(Worster A.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Neumann, J. T., et al. (författare)
  • Application of High-Sensitivity Troponin in Suspected Myocardial Infarction
  • 2019
  • Ingår i: New England Journal of Medicine. - : MASSACHUSETTS MEDICAL SOC. - 0028-4793 .- 1533-4406. ; 380:26, s. 2529-2540
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundData regarding high-sensitivity troponin concentrations in patients presenting to the emergency department with symptoms suggestive of myocardial infarction may be useful in determining the probability of myocardial infarction and subsequent 30-day outcomes. MethodsIn 15 international cohorts of patients presenting to the emergency department with symptoms suggestive of myocardial infarction, we determined the concentrations of high-sensitivity troponin I or high-sensitivity troponin T at presentation and after early or late serial sampling. The diagnostic and prognostic performance of multiple high-sensitivity troponin cutoff combinations was assessed with the use of a derivation-validation design. A risk-assessment tool that was based on these data was developed to estimate the risk of index myocardial infarction and of subsequent myocardial infarction or death at 30 days. ResultsAmong 22,651 patients (9604 in the derivation data set and 13,047 in the validation data set), the prevalence of myocardial infarction was 15.3%. Lower high-sensitivity troponin concentrations at presentation and smaller absolute changes during serial sampling were associated with a lower likelihood of myocardial infarction and a lower short-term risk of cardiovascular events. For example, high-sensitivity troponin I concentrations of less than 6 ng per liter and an absolute change of less than 4 ng per liter after 45 to 120 minutes (early serial sampling) resulted in a negative predictive value of 99.5% for myocardial infarction, with an associated 30-day risk of subsequent myocardial infarction or death of 0.2%; a total of 56.5% of the patients would be classified as being at low risk. These findings were confirmed in an external validation data set. ConclusionsA risk-assessment tool, which we developed to integrate the high-sensitivity troponin I or troponin T concentration at emergency department presentation, its dynamic change during serial sampling, and the time between the obtaining of samples, was used to estimate the probability of myocardial infarction on emergency department presentation and 30-day outcomes.
  •  
2.
  • Neumann, Johannes Tobias, et al. (författare)
  • Personalized diagnosis in suspected myocardial infarction
  • 2023
  • Ingår i: Clinical Research in Cardiology. - : Springer. - 1861-0684 .- 1861-0692. ; 112, s. 1288-1301
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In suspected myocardial infarction (MI), guidelines recommend using high-sensitivity cardiac troponin (hscTn)- based approaches. These require fixed assay-specific thresholds and timepoints, without directly integrating clinical information. Using machine-learning techniques including hs-cTn and clinical routine variables, we aimed to build a digital tool to directly estimate the individual probability of MI, allowing for numerous hs-cTn assays.Methods: In 2,575 patients presenting to the emergency department with suspected MI, two ensembles of machine-learning models using single or serial concentrations of six different hs-cTn assays were derived to estimate the individual MI probability ( ARTEMIS model). Discriminative performance of the models was assessed using area under the receiver operating characteristic curve (AUC) and logLoss. Model performance was validated in an external cohort with 1688 patients and tested for global generalizability in 13 international cohorts with 23,411 patients.Results: Eleven routinely available variables including age, sex, cardiovascular risk factors, electrocardiography, and hs-cTn were included in the ARTEMIS models. In the validation and generalization cohorts, excellent discriminative performance was confirmed, superior to hs-cTn only. For the serial hs-cTn measurement model, AUC ranged from 0.92 to 0.98. Good calibration was observed. Using a single hs-cTn measurement, the ARTEMIS model allowed direct rule-out of MI with very high and similar safety but up to tripled efficiency compared to the guideline- recommended strategy.Conclusion We developed and validated diagnostic models to accurately estimate the individual probability of MI, which allow for variable hs-cTn use and flexible timing of resampling. Their digital application may provide rapid, safe and efficient personalized patient care.
  •  
3.
  • Chiang, Cho-Han, et al. (författare)
  • Performance of the European Society of Cardiology 0/1-Hour, 0/2-Hour, and 0/3-Hour Algorithms for Rapid Triage of Acute Myocardial Infarction : An International Collaborative Meta-analysis
  • 2022
  • Ingår i: Annals of Internal Medicine. - 0003-4819. ; 175:1, s. 101-113
  • Forskningsöversikt (refereegranskat)abstract
    • BACKGROUND: The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI).PURPOSE: To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms.DATA SOURCES: PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479).STUDY SELECTION: Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI.DATA EXTRACTION: The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality.DATA SYNTHESIS: A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays.LIMITATION: Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies.CONCLUSION: The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI.PRIMARY FUNDING SOURCE: National Taiwan University Hospital.
  •  
4.
  • Kavsak, P. A., et al. (författare)
  • Cardiac Troponin Testing in Patients with COVID-19: A Strategy for Testing and Reporting Results
  • 2021
  • Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 67:1, s. 107-113
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that emerged late in 2019 causing COVID-19 (coronavirus disease-2019) may adversely affect the cardiovascular system. Publications from Asia, Europe, and North America have identified cardiac troponin as an important prognostic indicator for patients hospitalized with COVID-19. We recognized from publications within the first 6 months of the pandemic that there has been much uncertainty on the reporting, interpretation, and pathophysiology of an increased cardiac troponin concentration in this setting. CONTENT: The purpose of this mini-review is: a) to review the pathophysiology of SARS-CoV-2 and the cardiovascular system, b) to overview the strengths and weaknesses of selected studies evaluating cardiac troponin in patients with COVID-19, and c) to recommend testing strategies in the acute period, in the convalescence period and in long-term care for patients who have become ill with COVID-19. SUMMARY: This review provides important educational information and identifies gaps in understanding the role of cardiac troponin and COVID-19. Future, properly designed studies will hopefully provide the much-needed evidence on the path forward in testing cardiac troponin in patients with COVID-19.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy