SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wranne B.) "

Sökning: WFRF:(Wranne B.)

  • Resultat 1-13 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Boretzky, K., et al. (författare)
  • NeuLAND: The high-resolution neutron time-of-flight spectrometer for R 3 B at FAIR
  • 2021
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 1014
  • Tidskriftsartikel (refereegranskat)abstract
    • NeuLAND (New Large-Area Neutron Detector) is the next-generation neutron detector for the R3B (Reactions with Relativistic Radioactive Beams) experiment at FAIR (Facility for Antiproton and Ion Research). NeuLAND detects neutrons with energies from 100 to 1000 MeV, featuring a high detection efficiency, a high spatial and time resolution, and a large multi-neutron reconstruction efficiency. This is achieved by a highly granular design of organic scintillators: 3000 individual submodules with a size of 5 × 5 × 250 cm3 are arranged in 30 double planes with 100 submodules each, providing an active area of 250 × 250 cm2 and a total depth of 3 m. The spatial resolution due to the granularity together with a time resolution of σt≤ 150 ps ensures high-resolution capabilities. In conjunction with calorimetric properties, a multi-neutron reconstruction efficiency of 50% to 70% for four-neutron events will be achieved, depending on both the emission scenario and the boundary conditions allowed for the reconstruction method. We present in this paper the final design of the detector as well as results from test measurements and simulations on which this design is based.
  •  
2.
  •  
3.
  • Blomstrand, Peter, et al. (författare)
  • Assessment of left ventricular diastolic function from mitral annulus motion, a comparison with pulsed Doppler measurements in patients with heart failure
  • 1996
  • Ingår i: Clinical Physiology. - : John Wiley & Sons. - 0144-5979 .- 1365-2281. ; 16:5, s. 483-493
  • Tidskriftsartikel (refereegranskat)abstract
    • Mitral and pulmonary venous flow velocity recordings are often used for the assessment of left ventricular diastolic function. These curves are, however, also influenced by other factors. To investigate whether mitral annulus motion carries additional information in this context, mitral annulus motion was compared to Doppler registrations of mitral and pulmonary flow velocities in 38 patients with heart failure (NYHA II-III) after myocardial infarction. Patients with an increased atrial contribution to mitral annulus motion (> 57%, n = 12) had a higher mitral late-to-early flow velocity ratio (A/E) and pulmonary systolic to diastolic filling ratio (< 0.01). Patients with atrial displacement above average for the group (≤ 5.1 mm, n = 19) had a higher mitral A/E ratio and pulmonary systolic to diastolic filling ratio than patients with a lower than average atrial component (P < 0.05). There was a significant correlation between a/T ratio and A/E ratio (r = 0.61, P < 0.001) and between pulmonary flow and transmitral flow (= 0.76, P < 0.001). We conclude that an increased atrial displacement of the mitral annulus is a frequent finding in patients with signs of left ventricular relaxation abnormality. There is a significant correlation between a/T ratio and A/E ratio but the information contained in the two indices are not identical.
  •  
4.
  • Blomstrand, Peter, et al. (författare)
  • Cardiovascular effects of dobutamine stress testing in healthy women
  • 1995
  • Ingår i: Clinical Cardiology. - : John Wiley & Sons. - 0160-9289 .- 1932-8737. ; 18:11, s. 659-663
  • Tidskriftsartikel (refereegranskat)abstract
    • Dobutamine echocardiography is frequently used for detection of coronary artery disease. The circulatory response in patients is known to some extent, but studies in normals are lacking. Hypotensive response during the test is a common side effect, the cause of which is unclear. The aim of this study was, therefore, to investigate the hemodynamic response to dobutamine in women without cardiovascular disease and interfering medications. Eleven healthy women, age 53–71 years, were investigated with Doppler echocardiography and venous occlusion plethysmography during intravenous infusion of increasing doses of dobutamine according to a standardized protocol. An average peak dose of 22 ± 7.5 μMu kg‐1 min‐1 was administered. Cardiac output increased by 93%, heart rate by 68%, and stroke volume by 15%, while peripheral vascular resistance decreased by approximately 50%. Systolic blood pressure remained unchanged and diastolic blood pressure decreased by 21%. One subject demonstrated a decreased systolic blood pressure exceeding 10 mmHg. Outflow obstruction from the left ventricle was seen in two subjects, one of whom had a slight decrease of 10 mmHg in systolic blood pressure. Subjects > 65 years demonstrated a less pronounced increase in heart rate, cardiac output, and decrease in peripheral vascular resistance compared with those < 65 years.
  •  
5.
  • Blomstrand, Peter, et al. (författare)
  • Cardiovascular effects of dobutamine stress testing in women with suspected coronary artery disease
  • 1996
  • Ingår i: Heart. - : BMJ Publishing Group Ltd. - 1355-6037 .- 1468-201X. ; 75:5, s. 463-468
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To investigate the central and peripheral haemodynamic response to dobutamine stress testing in women with suspected ischaemic heart disease and to seek an explanation for the hypotension phenomenon. Design. 18 women aged 54-73 years were investigated with Doppler echocardiography and venous occlusion plethysmography during intravenous infusion of dobutamine 5-10 d after an episode of unstable angina. Results. An average peak dose of 33 (SD 9.7) μg/kg/min was given. Heart rate and cardiac output increased by 49% and 59%, respectively (P < 0.001). Total and leg peripheral vascular resistance decreased by 44% and 26%, respectively (P < 0.001). Four patients developed hypotension (decrease in systolic blood pressure > 10 mm Hg), one of whom had a paradoxical bradycardia and two a low increase in cardiac output. Patients with hypotension had a more pronounced decrease in total peripheral vascular resistance but a similar change in leg peripheral vascular resistance compared with patients without hypotension. Conclusions. Dobutamine infusion leads to marked peripheral vasodilatation and an increase in cardiac output. Some patients experience hypotension during the test for reasons which include paradoxical vasovagal reactions and diminished capacity for adequate increase in cardiac output. There is also a disparity between the pattern of total and leg peripheral vascular resistance in patients with hypotension which might reflect a baroreceptor mediated compensatory increase in vasoconstrictor tone of muscle vessels not matched in other vascular territories.
  •  
6.
  • Blomstrand, Peter, et al. (författare)
  • Exercise echocardiography : a methodological study comparing peak‐exercise and post‐exercise image information
  • 1992
  • Ingår i: Clinical Physiology. - : John Wiley & Sons. - 0144-5979 .- 1365-2281. ; 12:5, s. 553-565
  • Tidskriftsartikel (refereegranskat)abstract
    • It is unclear whether echocardiography at peak bicycle exercise adds information to registrations obtained recumbent immediately after the test and what factors influence image quality. Therefore, exercise echocardiography was performed consecutively and prospectively in 66 men, unselected with regard to echocardiography, one month after an episode of unstable coronary artery disease. Of 594 segments (9 × 66), 569 (96%) were adequately visualized recumbent at rest. The corresponding figures recumbent directly after exercise, seated before exercise, and seated at peak exercise were 544 (92%), 474 (80%), and 428 (72%), respectively. In the majority of our patients, acceptable images at peak exercise were obtained for the septal region, while for the anterior, lateral, and inferior segments the success rate varied from 50 to 70%. Recumbent after exercise, the success rate was acceptable for most segments, possibly with the exception of the apical and lateral segments. Fifty‐five patients developed new wall motion abnormalities or worsening of wall motion in connection with exercise. Echocardiography at peak exercise provided more information than afterwards in patients with images of good quality. However, in patients with inferior image quality, the registrations obtained recumbent after the test revealed wall motion abnormalities which were not obtained seated at peak exercise. Patients with worse image quality had significantly higher respiratory rate and weight, and rated a higher degree of dyspnoea at peak exercise than those with good quality. We conclude that in middle aged men with coronary artery disease, image acquisition at peak bicycle exercise and immediately after exercise are of complementary value.
  •  
7.
  • Blomstrand, Peter, et al. (författare)
  • Exercise echocardiography and thallium 201 single-photon emission computed tomography in male patients after an episode of unstable coronary artery disease
  • 1994
  • Ingår i: American Journal of Cardiac Imaging. - 0887-7971. ; 8:4, s. 283-289
  • Tidskriftsartikel (refereegranskat)abstract
    • To compare modern, digital exercise echocardiography and thallium 201 single-photon emission computed tomography (SPECT) in patients with unstable coronary artery disease, 65 men unselected with regard to echocardiography were prospectively investigated 1 month after an episode of unstable angina or non-Q-wave myocardial infarction. Exercise echocardiography and 201Tl SPECT were performed on consecutive days in connection with a standard symptom-limited upright bicycle test and analyzed in a 9-segment model. Coronary angiography was performed in all but 1 patient and 60 patients had significant coronary lesions. Wall motion abnormalities were seen in 53 patients (81%) at rest and perfusion defects in 57 patients (88%) at the redistribution images. New or worsening of wall motion abnormalities were seen in 55 patients, either seated at peak exercise or recumbent after exercise, and 43 patients had reversible or partially reversible 201Tl scintigraphic defects (P = .02). The segmental agreement between wall motion abnormalities and scintigraphic defects was low (58%). The additional value of exercise echocardiography and 201Tl SPECT to exercise test was greatest in patients with one-vessel disease. Thus, 1 month after an episode of unstable coronary artery disease in men, there is a high incidence of significant coronary stenoses as well as signs of ischemia shown both by wall motion abnormalities during exercise echocardiography and by postexercise studies with 201Tl SPECT. Exercise echocardiography gives a higher diagnostic yield regarding occurrence of reversible ischemia.
  •  
8.
  • Bood, Mattias, et al. (författare)
  • Pentacyclic adenine: a versatile and exceptionally bright fluorescent DNA base analogue
  • 2018
  • Ingår i: Chemical Science. - : Royal Society of Chemistry (RSC). - 2041-6520 .- 2041-6539. ; 9:14, s. 3494-3502
  • Tidskriftsartikel (refereegranskat)abstract
    • Emissive base analogs are powerful tools for probing nucleic acids at the molecular level. Herein we describe the development and thorough characterization of pentacyclic adenine (pA), a versatile base analog with exceptional fluorescence properties. When incorporated into DNA, pA pairs selectively with thymine without perturbing the B-form structure and is among the brightest nucleobase analogs reported so far. Together with the recently established base analog acceptor qAnitro, pA allows accurate distance and orientation determination via Forster resonance energy transfer (FRET) measurements. The high brightness at emission wavelengths above 400 nm also makes it suitable for fluorescence microscopy, as demonstrated by imaging of single liposomal constructs coated with cholesterolanchored pA-dsDNA, using total internal reflection fluorescence microscopy. Finally, pA is also highly promising for two-photon excitation at 780 nm, with a brightness (5.3 GM) that is unprecedented for a base analog.
  •  
9.
  •  
10.
  • Lindquist, B, et al. (författare)
  • "Hälsokost" som barnmat
  • 1975
  • Ingår i: Läkartidningen. - 0023-7205 .- 1652-7518. ; 72:9
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
11.
  • von Bibra, H, et al. (författare)
  • [Contrast echocardiography]
  • 2000
  • Ingår i: Zeitschrift fur Kardiologie. - : Springer Science and Business Media LLC. - 0300-5860 .- 1435-1285. ; 8989 Suppl 1, s. 86-96
  • Tidskriftsartikel (refereegranskat)
  •  
12.
  • Wranne, Bengt, et al. (författare)
  • Inte så lätt att anvanda stetoskopet på rätt sätt. Auskultationens svåra konst bör ha stort utrymme i läkarutbildningen.
  • 1999
  • Ingår i: Läkartidningen. - 0023-7205 .- 1652-7518. ; 96:24, s. 2981-2984
  • Tidskriftsartikel (refereegranskat)abstract
    • Although the stethoscope is used daily by almost every physician, the full potential of the art of stethoscopy is seldom tapped. It has been replaced by newer and more costly techniques. In the article it is argued that more time in medical education should be allocated to stethoscopy, so that it can be used in selecting patients who will benefit most from examination with modern diagnostic tools. The medical technological background of stethoscopy is also reviewed, as are the reasons why it is difficult to give sound advice on the choice of stethoscope.
  •  
13.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-13 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy