SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zakrzewska M.) "

Sökning: WFRF:(Zakrzewska M.)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Guidoboni, G., et al. (författare)
  • How to Reach a Thousand-Second in-Plane Polarization Lifetime with 0.97-GeV/c Deuterons in a Storage Ring
  • 2016
  • Ingår i: Physical Review Letters. - : American Physical Society. - 0031-9007 .- 1079-7114. ; 117:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We observe a deuteron beam polarization lifetime near 1000 s in the horizontal plane of a magnetic storage ring (COSY). This long spin coherence time is maintained through a combination of beam bunching, electron cooling, sextupole field corrections, and the suppression of collective effects through beam current limits. This record lifetime is required for a storage ring search for an intrinsic electric dipole moment on the deuteron at a statistical sensitivity level approaching 10(-29) e cm.
  •  
3.
  • Eversmann, D., et al. (författare)
  • New Method for a Continuous Determination of the Spin Tune in Storage Rings and Implications for Precision Experiments
  • 2015
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 115:9
  • Tidskriftsartikel (refereegranskat)abstract
    • A new method to determine the spin tune is described and tested. In an ideal planar magnetic ring, the spin tune-defined as the number of spin precessions per turn-is given by nu(s) = gamma G (gamma is the Lorentz factor, G the gyromagnetic anomaly). At 970 MeV/c, the deuteron spins coherently process at a frequency of approximate to 120 kHz in the Cooler Synchrotron COSY. The spin tune is deduced from the up-down asymmetry of deuteron-carbon scattering. In a time interval of 2.6 s, the spin tune was determined with a precision of the order 10(-8), and to 1 x 10(-10) for a continuous 100 s accelerator cycle. This renders the presented method a new precision tool for accelerator physics; controlling the spin motion of particles to high precision is mandatory, in particular, for the measurement of electric dipole moments of charged particles in a storage ring.
  •  
4.
  •  
5.
  •  
6.
  • Schiffman, E, et al. (författare)
  • Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications : recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group
  • 2014
  • Ingår i: Journal of oral & facial pain and headache. - : Quintessence. - 2333-0384 .- 2333-0376. ; 28:1, s. 6-27
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. METHODS: Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project-the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. RESULTS: The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra-articular disorder (sensitivity of 0.80 and specificity of 0.97). Diagnostic criteria for other common intra-articular disorders lack adequate validity for clinical diagnoses but can be used for screening purposes. Inter-examiner reliability for the clinical assessment associated with the validated DC/TMD criteria for pain-related TMD is excellent (kappa ≥ 0.85). Finally, a comprehensive classification system that includes both the common and less common TMD is also presented. The Axis II protocol retains selected original RDC/TMD screening instruments augmented with new instruments to assess jaw function as well as behavioral and additional psychosocial factors. The Axis II protocol is divided into screening and comprehensive self report instrument sets. The screening instruments' 41 questions assess pain intensity, pain-related disability, psychological distress, jaw functional limitations, and parafunctional behaviors, and a pain drawing is used to assess locations of pain. The comprehensive instruments, composed of 81 questions, assess in further detail jaw functional limitations and psychological distress as well as additional constructs of anxiety and presence of comorbid pain conditions. CONCLUSION: The recommended evidence-based new DC/TMD protocol is appropriate for use in both clinical and research settings. More comprehensive instruments augment short and simple screening instruments for Axis I and Axis II. These validated instruments allow for identification of patients with a range of simple to complex TMD presentations
  •  
7.
  •  
8.
  • Zakrzewska, A., et al. (författare)
  • Substituent effects on the photophysical properties of fluorescent 2-benzoylmethylenequinoline difluoroboranes : A combined experimental and quantum chemical study Dedication: This publication is dedicated to the memory of Prof. Jerzy Pa̧czkowski.
  • 2013
  • Ingår i: Dyes and pigments. - : Elsevier BV. - 0143-7208 .- 1873-3743. ; 99:3, s. 957-965
  • Tidskriftsartikel (refereegranskat)abstract
    • In this study, we demonstrate a successful synergy between theory and experiment and report on the photophysical properties of a recently synthesized series of substituted 2-benzoylmethylenequinoline difluoroboranes with a view towards the effect of substitution on their properties. In general difluoroboranes are known to have a bright fluorescence but for some analogs the properties are not fully understood. Quantum chemistry methods have been applied in order to explain a complex structure of the absorption and emission spectra and to gain an insight into the charge redistribution upon the excitation of the investigated molecules. We demonstrate that the spectra of this important class of compounds can be satisfactorily simulated using quantum chemistry methods. In particular, the absorption and emission band structure was resolved and the spectral features were assigned to C-H wagging and skeletal vibrations of the polycyclic core.
  •  
9.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy