1.
  • Fredenberg, Erik, 1979- (författare)
  • Spectral Mammography with X-Ray Optics and a Photon-Counting Detector
  • 2009
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Early detection is vital to successfully treating breast cancer, and mammography screening is the most efficient and wide-spread method to reach this goal. Imaging low-contrast targets, while minimizing the radiation exposure to a large population is, however, a major challenge. Optimizing the image quality per unit radiation dose is therefore essential. In this thesis, two optimization schemes with respect to x-ray photon energy have been investigated: filtering the incident spectrum with refractive x-ray optics (spectral shaping), and utilizing the transmitted spectrum with energy-resolved photon-counting detectors (spectral imaging). Two types of x-ray lenses were experimentally characterized, and modeled using ray tracing, field propagation, and geometrical optics. Spectral shaping reduced dose approximately 20% compared to an absorption-filtered reference system with the same signal-to-noise ratio, scan time, and spatial resolution. In addition, a focusing pre-object collimator based on the same type of optics reduced divergence of the radiation and improved photon economy by about 50%. A photon-counting silicon detector was investigated in terms of energy resolution and its feasibility for spectral imaging. Contrast-enhanced tumor imaging with a system based on the detector was characterized and optimized with a model that took anatomical noise into account. Improvement in an ideal-observer detectability index by a factor of 2 to 8 over that obtained by conventional absorption imaging was found for different levels of anatomical noise and breast density. Increased conspicuity was confirmed by experiment. Further, the model was extended to include imaging of unenhanced lesions. Detectability of microcalcifications increased no more than a few percent, whereas the ability to detect large tumors might improve on the order of 50% despite the low attenuation difference between glandular and cancerous tissue. It is clear that inclusion of anatomical noise and imaging task in spectral optimization may yield completely different results than an analysis based solely on quantum noise.
  •  
2.
  • Liu, Yuanhua, 1971, et al. (författare)
  • Considering the importance of user profiles in interface design
  • 2009
  • Ingår i: User Interfaces. ; , s. 23-
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • User profile is a popular term widely employed during product design processes by industrial companies. Such a profile is normally intended to represent real users of a product. The ultimate purpose of a user profile is actually to help designers to recognize or learn about the real user by presenting them with a description of a real user’s attributes, for instance; the user’s gender, age, educational level, attitude, technical needs and skill level. The aim of this chapter is to provide information on the current knowledge and research about user profile issues, as well as to emphasize the importance of considering these issues in interface design. In this chapter, we mainly focus on how users’ difference in expertise affects their performance or activity in various interaction contexts. Considering the complex interaction situations in practice, novice and expert users’ interactions with medical user interfaces of different technical complexity will be analyzed as examples: one focuses on novice and expert users’ difference when interacting with simple medical interfaces, and the other focuses on differences when interacting with complex medical interfaces. Four issues will be analyzed and discussed: (1) how novice and expert users differ in terms of performance during the interaction; (2) how novice and expert users differ in the perspective of cognitive mental models during the interaction; (3) how novice and expert users should be defined in practice; and (4) what are the main differences between novice and expert users’ implications for interface design. Besides describing the effect of users’ expertise difference during the interface design process, we will also pinpoint some potential problems for the research on interface design, as well as some future challenges that academic researchers and industrial engineers should face in practice.
  •  
3.
  • Munthe, Christian, 1962 (författare)
  • Etiska aspekter på regenerativ medicin : Ethical aspects on regenerative medicine
  • 2003
  • Ingår i: SNIB-konferensen 2003, Chalmers tekniska högskola, Göteborg, 16-18 maj 2003.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Inom den regenerativa medicinen strävar man efter att ersätta skadat eller sjukligt biologiskt mänskligt material (celler, organ, kroppsdelar) med nya biologiska komponenter. Området aktualiserar en rad etiska frågeställningar vad gäller (1) produktionen av ersättningsmaterialet (t.ex. embryonala stamceller eller införskaffande av transplantationsvävnad från donatorer), (2) risker i samband med försök på människa (genmodifierat material, material från djur), samt (3) gränserna för hur långt man bör gå i denna slags försök att förlänga människans livsspann. Föredraget ger en kort översikt över dessa frågeställningar, ståndpunkter och argument i debatten kring dem.
  •  
4.
  •  
5.
  • Y Banaem, Hossein, et al. (författare)
  • Brain tumor modeling : glioma growth and interaction with chemotherapy
  • 2011
  • Ingår i: International Conference on Graphic and Image Processing (ICGIP 2011). - : SPIE. ; 8285
  • Konferensbidrag (refereegranskat)abstract
    • In last decade increasingly mathematical models of tumor growths have been studied, particularly on solid tumors which growth mainly caused by cellular proliferation. In this paper we propose a modified model to simulate the growth of gliomas in different stages. Glioma growth is modeled by a reaction-advection-diffusion. We begin with a model of untreated gliomas and continue with models of polyclonal glioma following chemotherapy. From relatively simple assumptions involving homogeneous brain tissue bounded by a few gross anatomical landmarks (ventricles and skull) the models have been expanded to include heterogeneous brain tissue with different motilities of glioma cells in grey and white matter. Tumor growth is characterized by a dangerous change in the control mechanisms, which normally maintain a balance between the rate of proliferation and the rate of apoptosis (controlled cell death). Result shows that this model closes to clinical finding and can simulate brain tumor behavior properly.
  •  
6.
  • Löfhede, Johan, et al. (författare)
  • Comparing a Supervised and an Unsupervised Classification Method for Burst Detection in Neonatal EEG
  • 2008
  • Ingår i: Proceedings of Engineering in Medicine and Biology Society, EMBS 2008. 30th Annual International Conference of the IEEE, 20-24 August, 2008. - : IEEE. - 1557-170X. - 9781424418145 ; , s. 3836-3839
  • Konferensbidrag (refereegranskat)abstract
    • Hidden Markov Models (HMM) and Support Vector Machines (SVM) using unsupervised and supervised training, respectively, were compared with respect to their ability to correctly classify burst and suppression in neonatal EEG. Each classifier was fed five feature signals extracted from EEG signals from six full term infants who had suffered from perinatal asphyxia. Visual inspection of the EEG by an experienced electroencephalographer was used as the gold standard when training the SVM, and for evaluating the performance of both methods. The results are presented as receiver operating characteristic (ROC) curves and quantified by the area under the curve (AUC). Our study show that the SVM and the HMM exhibit similar performance, despite their fundamental differences.
  •  
7.
  • Cutas, Daniela, 1978, et al. (författare)
  • Legal imperialism in the regulation of stem cell research and therapy: the problem of extraterritorial jurisdiction
  • 2010
  • Ingår i: Capps BJ & Campbell AV (eds.). CONTESTED CELLS: Global Perspectives on the Stem Cell Debate. - London : Imperial College Press. - 9781848164376 ; , s. 95-119
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • Countries worldwide have very different national regulations on human embryonic stem (ES) cell research, informed by a range of ethical values. Some countries find reason to extend the applicability of their regulations on such research to its citizens when they visit other countries. Extraterritorial jurisdiction has recently been identified as a potential challenge towards global regulation of ES cell research. This chapter explores the implications and impact of extraterritorial jurisdiction and global regulation of ES cell research on researchers, clinicians and national health systems, and how this may affect patients. The authors argue that it would make ethical sense for ES cell restrictive countries to extend its regulations on ES cell research beyond its borders, because, if these countries really consider embryo destruction to be objectionable on the basis on the status of the embryo, then they ought to count it morally on par with murder (and thus have a moral imperative to protect embryos from the actions of its own citizens). However, doing so could lead to a legal situation that would result in substantial harm to central values in areas besides research, such as health care, the job market, basic freedom of movement, and strategic international finance and politics. Thus, it seems that restrictive extraterritorial jurisdiction in respect to ES cell research would be deeply problematic, given that the ethical permissibility of ES cell research is characterised by deep and wide disagreement.
  •  
8.
  • Fredenberg, Erik, PhD, 1979-, et al. (författare)
  • A low-absorption x-ray energy filter for small-scale applications
  • 2009
  • Ingår i: Optics Express. - : The Optical Society. - 1094-4087. ; 17:14, s. 11388-11398
  • Tidskriftsartikel (refereegranskat)abstract
    • We present an experimental and theoretical evaluation of an x-ray energy filter based on the chromatic properties of a prism-array lens (PAL). It is intended for small-scale applications such as medical imaging. The PAL approximates a Fresnel lens and allows for high efficiency compared to filters based on ordinary refractive lenses, however at the cost of a lower energy resolution. Geometrical optics was found to provide a good approximation for the performance of a flawless lens, but a field-propagation model was used for quantitative predictions. The model predicted a 0.29 ΔE/E energy resolution and an intensity gain of 6.5 for a silicon PAL at 23.5 keV. Measurements with an x-ray tube showed good agreement with the model in energy resolution and peak energy, but a blurred focal line contributed to a 29% gain reduction. We believe the blurring to be caused mainly by lens imperfections, in particular at the periphery of the lens.
  •  
9.
  • Fredenberg, Erik, PhD, 1979-, et al. (författare)
  • A Tunable Energy Filter for Medical X-Ray Imaging
  • 2008
  • Ingår i: X-Ray Optics and Instrumentation. - : Hindawi. - 1687-7632 .- 1687-7640. ; 2008
  • Tidskriftsartikel (refereegranskat)abstract
    • A multiprism lens (MPL) is a refractive X-ray lens, and its chromatic properties can be employed in an energy filtering setup to obtain a narrow tunable X-ray spectrum. We present the first evaluation of such a filter for medical X-ray imaging. The experimental setup yields a 6.6 gain of flux at 20 keV, and we demonstrate tunability by altering the energy spectrum to center also around 17 and 23 keV. All measurements are found to agree well with ray-tracing and a proposed geometrical model. Compared to a model mammography system with absorption filtering, the experimental MPL filter reduces dose 13–25% for 3–7 cm breasts if the spectrum is centered around the optimal energy. Additionally, the resolution is improved 2.5 times for a 5 cm breast. The scan time is increased 3 times but can be reduced with a slightly decreased energy filtering and resolution.
  •  
10.
  • Fredenberg, Erik, PhD, 1979-, et al. (författare)
  • Contrast-enhanced spectral mammography with a photon-counting detector
  • 2010
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405. ; 37:5, s. 2017-2029
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. In particular, the detectability of a contrast agent can be improved over a lumpy background. We have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved imaging was studied.Methods: A framework for system characterization was set up that included quantum and anatomical noise, and a theoretical model of the system was benchmarked to phantom measurements.Results: It was found that optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, and an ideal-observer detectability index could be improved more than a factor of two compared to absorption imaging in the phantom study. In the clinical case, an improvement close to 80% was predicted for an average glandularity breast, and a factor of eight for dense breast tissue. Another 70% was found to be within reach for an optimized system.Conclusions: Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements.
  •  
11.
  • Fredenberg, Erik, PhD, 1979-, et al. (författare)
  • Energy filtering with x-ray lenses: Optimization for photon-counting mammography
  • 2010
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 139, s. 339-342
  • Tidskriftsartikel (refereegranskat)abstract
    • Chromatic properties of the multi-prism and prism-array x-ray lenses (MPL and PAL) can potentially be utilized for efficient energy filtering and dose reduction in mammography. The line-shaped foci of the lenses are optimal for coupling to photon-counting silicon strip detectors in a scanning system. A theoretical model was developed and used to investigate the benefit of two lenses compared to an absorption-filtered reference system. The dose reduction of the MPL filter was 15% compared to the reference system at matching scan time, and the spatial resolution was higher. The dose of the PAL-filtered system was found to be 20% lower than for the reference system at equal scan time and resolution, and only 20% higher than for a monochromatic beam. An investigation of some practical issues remains, including the feasibility of brilliant-enough x-ray sources and manufacturing of a polymer PAL.
  •  
12.
  •  
13.
  • Hafid, Abdelakram, et al. (författare)
  • Full Impedance Cardiography Measurement Device Using Raspberry PI3 and System-on-Chip Biomedical Instrumentation Solutions
  • 2018
  • Ingår i: IEEE journal of biomedical and health informatics. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 2168-2194 .- 2168-2208. ; 22:6, s. 1883-1894
  • Tidskriftsartikel (refereegranskat)abstract
    • Impedance cardiography (ICG) is a noninvasive method for monitoring cardiac dynamics using electrical bioimpedance (EBI) measurements. Since its appearance more than 40 years ago, ICG has been used for assessing hemodynamic parameters. This paper presents a measurement system based on two System on Chip (SoC) solutions and Raspberry PI, implementing both a full three-lead ECG recorder and an impedance cardiographer, for educational and research development purposes. Raspberry PI is a platform supporting Do-I t-Yourself project and education applications across the world. The development is part of Biosignal PI, an open hardware platform focusing in quick prototyping of physiological measurement instrumentation. The SoC used for sensing cardiac biopotential is the ADAS1000, and for the EBI measurement is the AD5933. The recordings were wirelessly transmitted through Bluetooth to a PC, where the waveforms were displayed, and hemodynamic parameters such as heart rate, stroke volume, ejection time and cardiac output were extracted from the ICG and ECG recordings. These results show how Raspberry PI can be used for quick prototyping using relatively widely available and affordable components, for supporting developers in research and engineering education. The design and development documents will be available on www.BiosignalPl.com, for open access under a Non Commercial-Share A like 4.0 International License.
  •  
14.
  • Jing, Yujia, 1985 (författare)
  • Hyperthermia-responsive liposomal systems
  • 2015
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Abstract Sophisticated liposomal systems are emerging at an increasing rate to meet the demands for multifunctional drug carriers in chemotherapies in combined with hyperthermia. For example, liposomal drug carriers for temperature-controlled drug release under hyperthermic conditions have recently been tested in clinical trials. More advanced designs of liposomes are expected to release encapsulated contents and activate hidden surface-functions in response to heat stimulus. Towards this aim, the present thesis is focused on formulating asymmetric lipid systems that can preserve functional moieties, and reactivate the targeted function as well as release the encapsulated compounds upon local heating. The design of the asymmetric liposomal systems utilizes the heat-activated transmembrane lipid diffusion during gel to liquid-crystalline phase transitions of the lipid membranes.Rational design of advanced liposomal drug-delivery systems will require understanding of the physicochemical properties of lipid membranes under, e.g., hyperthermic conditions. Here, supported lipid membranes on planar solid surfaces were used for model studies of lipid composition yielding a gel to liquid crystalline phase-transition temperature in the range 40 – 45 °C. It was found that the liposome-to-membrane formation process is not only size-dependent but also governed by temperature. Two methods of preparing supported asymmetric lipid membranes were investigated. As a proof-of-concept, the upper leaflets were either replaced or chemically transformed by enzymatic hydrolysis. The processes were monitored using surface sensitive techniques such as quartz crystal microbalance with dissipation (QCM-D) and dual polarization interferometry (DPI). The asymmetric structures were stable at a room temperature, while lipid flip-flop was induced upon increasing of the temperature. Transmembrane lipid exchange in the asymmetric structure under hyperthermic conditions was demonstrated by detecting, through streptavidin binding, biotinylated lipids appearing at the top leaflet which were first located in the lower leaflet. The protocols developed for the supported lipid systems were adapted for the preparation of asymmetric liposomes. Biotinylated asymmetric liposomes were used as a model system to demonstrate the principle of heat-activated targeting of asymmetric liposomes to streptavidin-coated surfaces. More biologically relevant interaction was utilized to replace the biotin-streptavidin function, where asymmetric cationic liposomes were binding to anionic supported membrane immobilized surfaces upon heating. The described strategies for assembly of asymmetric supported membranes provide a guide to the development of multifunctional drug carriers. The protocols used in experiments with supported membranes were readily adapted to the preparation of asymmetric liposomes. The ongoing study tests the asymmetric liposomes in vitro, which is designed to demonstrate hyperthermia treatment can enhance accumulation of liposomes in FaDu cells, and at the same time activate release of the encapsulated components. The results of in vitro tests can be used to analyze the feasibility of utilizing the asymmetric liposomes as a platform in vivo to explore further improvement in their functions upon microwave hyperthermia.
  •  
15.
  • Pfeiffer, Christoph, 1989, et al. (författare)
  • Localizing on-scalp MEG sensors using an array of magnetic dipole coils
  • 2018
  • Ingår i: Plos One. - : Public Library of Science (PLoS). - 1932-6203. ; 13:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Accurate estimation of the neural activity underlying magnetoencephalography (MEG) signals requires co-registration i.e., determination of the position and orientation of the sensors with respect to the head. In modern MEG systems, an array of hundreds of low- T c SQUID sensors is used to localize a set of small, magnetic dipole-like (head-position indicator, HPI) coils that are attached to the subject's head. With accurate prior knowledge of the positions and orientations of the sensors with respect to one another, the HPI coils can be localized with high precision, and thereby the positions of the sensors in relation to the head. With advances in magnetic field sensing technologies, e.g., high-T-c SQUIDs and optically pumped magnetometers (OPM), that require less extreme operating temperatures than low- T-c SQUID sensors, on-scalp MEG is on the horizon. To utilize the full potential of on-scalp MEG, flexible sensor arrays are preferable. Conventional co-registration is impractical for such systems as the relative positions and orientations of the sensors to each other are subject-specific and hence not known a priori. Herein, we present a method for co-registration of on-scalp MEG sensors. We propose to invert the conventional co-registration approach and localize the sensors relative to an array of HPI coils on the subject's head. We show that given accurate prior knowledge of the positions of the HPI coils with respect to one another, the sensors can be localized with high precision. We simulated our method with realistic parameters and layouts for sensor and coil arrays. Results indicate co-registration is possible with sub-millimeter accuracy, but the performance strongly depends upon a number of factors. Accurate calibration of the coils and precise determination of the positions and orientations of the coils with respect to one another are crucial. Finally, we propose methods to tackle practical challenges to further improve the method.
  •  
16.
  •  
17.
  • Xu, Cheng (författare)
  • A Segmented Silicon Strip Detector for Photon-Counting Spectral Computed Tomography
  • 2012
  • Konstnärligt arbete (övrigt vetenskapligt/konstnärligt)abstract
    • Spectral computed tomography with energy-resolving detectors has a potential to improve the detectability of images and correspondingly reduce the radiation dose to patients by extracting and properly using the energy information in the broad x-ray spectrum. A silicon photon-counting detector has been developed for spectral CT and it has successfully solved the problem of high photon flux in clinical CT applications by adopting the segmented detector structure and operating the detector in edge-on geometry. The detector was evaluated by both the simulation and measurements.The effects of energy loss and charge sharing on the energy response of this segmented silicon strip detector with different pixel sizes were investigated by Monte Carlo simulation and a comparison to pixelated CdTe detectors is presented. The validity of spherical approximations of initial charge cloud shape in silicon detectors was evaluated and a more accurate statistical model has been proposed.A photon-counting energy-resolving application specific integrated circuit (ASIC) developed for spectral CT was characterized extensively by electrical pulses, pulsed laser and real x-ray photons from both the synchrotron and an x-ray tube. It has been demonstrated that the ASIC performs as designed. A noise level of 1.09 keV RMS has been measured and a threshold dispersion of 0.89 keV RMS has been determined. The count rate performance of the ASIC in terms of count loss and energy resolution was evaluated by real x-rays and promising results have been obtained.The segmented silicon strip detector was evaluated using synchrotron radiation. An energy resolution of 16.1% has been determined with 22 keV photons in the lowest flux limit, which deteriorates to 21.5% at an input count rate of 100 Mcps mm−2. The fraction of charge shared events has been estimated and found to be 11.1% for 22 keV and 15.3% for 30 keV. A lower fraction of charge shared events and an improved energy resolution can be expected by applying a higher bias voltage to the detector.
  •  
18.
  • Rowa, Per, et al. (författare)
  • Automated Malaria Parasite Detection
  • 1977
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • A system for malaria parasite detection in thin blood-smears is presented. Sample slides prepared with standard methods are accepted. A low-cost TV-camera mounted on an ordinary microscope with a computer controlled stage is used as a picture sensor. Frames, digitized in windows of 64 x 64 pixels are fed into a special purpose picture processor at normal frame rate (25 frames/sec). In the picture processor measurements are made on the images at high speed. The classification problem is split into different levels each having different characteristics such as different sampling density. Four classes, three of which are different types of malaria parasites, are recognized. As a whole the classification is best labelled as a sequential pattern recognition procedure.In its preliminary version the system has been run at a speed comparable to that of a human operator, that is l 500 cells per minute. A test on 80 000 cells gave 25 false negatives out of 283 parasites (9%) and 41 false positives (0.05%).
  •  
19.
  •  
20.
  • Thordstein, Magnus, et al. (författare)
  • Effects of inflammation on cerebral electric activity in fetal sheep
  • 2008
  • Ingår i: 2nd Congress of the European Academy of Paediatrics, Nice 23-28 okt 2008.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • OBJECTIVE Intrauterine infections can by themselves induce fetal brain damage but also potentiate the effects of other harmful influences such as asphyxia and seizures. Using an EEG technique that permits the recording of extremely low frequencies, often called DC EEG, changes in the level, i.e. DC shifts can be detected. The DC level has been suggested to depend mainly on the potential over the blood brain barrier (BBB), in turn decided primarily by the arterial level of pCO2. Fetuses affected by infection/inflammation that produce detrimental effects on the brain, may have elevated levels of pCO2 and disturbance of the BBB. We aimed at investigating the possibility that the DC EEG could be used to detect the effects of inflammation on the fetal brain. METHODS Fetal sheep were instrumented at 97 days of gestation with catheters, four active EEG electrodes placed on the dura mater as well as extracranial reference and ground electrodes. After three days of recovery, the bacterial endotoxin lipopolysaccharide (LPS) was given to the fetus (200 ng i.v.). RESULTS Exposure to LPS induced a positive DC shift in parallel to the assumed affection of cerebral function and to the pCO2 elevation. This change was not always obvious in standard EEG. CONCLUSIONS These recordings of fetal DC EEG appear to be the first to be done. They indicate that the effects of inflammation on cerebral function can be monitored by DC EEG. Such monitoring might be feasible also during late stages of labour and in neonates.
  •  
21.
  •  
22.
  • Eklund, Anders, et al. (författare)
  • Evaluation of applanation resonator sensors for intra-ocular pressure measurement : results from clinical and in vitro studies.
  • 2003
  • Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 41:2, s. 190-197
  • Tidskriftsartikel (refereegranskat)abstract
    • Glaucoma is an eye disease that, in its most common form, is characterised by high intra-ocular pressure (IOP), reduced visual field and optic nerve damage. For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring IOP. Recently, an applanation resonator sensor (ARS) for measuring IOP was introduced and evaluated using an in vitro pig-eye model. In the present study, the first clinical evaluation of the same probe has been carried out, with experiments in vivo on human eyes. There was a low but significant correlation between IOP(ARS) and the IOP measured with a Goldmann applanation tonometer (r = 0.40, p = 0.001, n = 72). However, off-centre positioning of the sensor against the cornea caused a non-negligible source of error. The sensor probe was redesigned to have a spherical, instead of flat, contact surface against the eye and was evaluated in the in vitro model. The new probe showed reduced sensitivity to off-centre positioning, with a decrease in relative deviation from 89% to 11% (1 mm radius). For normalised data, linear regression between IOP(ARS) and direct IOP measurement in the vitreous chamber showed a correlation of r = 0.97 (p < 0.001, n = 108) and a standard deviation for the residuals of SD < or = 2.18 mm Hg (n = 108). It was concluded that a spherical contact surface should be preferred and that further development towards a clinical instrument should focus on probe design and signal analysis.
  •  
23.
  • Seoane, Fernando, 1976-, et al. (författare)
  • Electrical Bioimpedance Spectroscopy on Acute Unilateral Stroke Patients : Initial Observations regarding Differences between Sides
  • 2015
  • Ingår i: BioMed Research International. - : Hindawi Publishing Corporation. - 2314-6133 .- 2314-6141. ; 2015
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose. Electrical Bioimpedance Cerebral Monitoring is assessment in real time of health of brain tissue through study of passive dielectric properties of brain. During the last two decades theory and technology have been developed in parallel with animal experiments aiming to confirm feasibility of using bioimpedance-based technology for prompt detection of brain damage. Here, for the first time, we show that electrical bioimpedance measurements for left and right hemispheres are significantly different in acute cases of unilateral stroke within 24 hours from onset. Methods. Electrical BIS measurements have been taken in healthy volunteers and patients suffering from acute stroke within 24 hours of onset. BIS measurements have been obtained using SFB7 bioimpedance spectrometer manufactured by Impedimed ltd. and 4-electrode method. Measurement electrodes, current, and voltage have been placed according to 10–20 EEG system obtaining mutual BIS measurements from 4 different channels situated in pairs symmetrically from the midsagittal line. Obtained BIS data has been analyzed, assessing for symmetries and differences regarding healthy control data.Results. 7 out of 10 patients for Side-2-Side comparisons and 8 out 10 for central/lateral comparison presented values outside the range defined by healthy control group. When combined only 1 of 10 patients exhibited values within the healthy range. Conclusions. If these initial observations are confirmed with more patients, we can foresee emerging of noninvasive monitoring technology for brain damage with the potential to lead to paradigm shift in treatment of brain stroke and traumatic brain damage.
  •  
24.
  • Fredenberg, Erik, 1979-, et al. (författare)
  • An efficient pre-object collimator based on an x-ray lens
  • 2009
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405. ; 36:2, s. 626-633
  • Tidskriftsartikel (refereegranskat)abstract
    • A multiprism lens (MPL) is a refractive x-ray lens with one-dimensional focusing properties. If used as a pre-object collimator in a scanning system for medical x-ray imaging, it reduces the divergence of the radiation and improves on photon economy compared to a slit collimator. Potential advantages include shorter acquisition times, a reduced tube loading, or improved resolution. We present the first images acquired with a MPL in a prototype for a scanning mammography system. The lens showed a gain of flux of 1.32 compared to a slit collimator at equal resolution, or a gain in resolution of 1.31–1.44 at equal flux. We expect the gain of flux in a clinical setup with an optimized MPL and a custom-made absorption filter to reach 1.67, or 1.45–1.54 gain in resolution.
  •  
25.
  • Jacobsson, Martin, 1976-, et al. (författare)
  • Deep Learning-Based Early Prediction of Intraoperative Hypotension
  • 2021
  • Konferensbidrag (refereegranskat)abstract
    • This work focuses on predicting near-term onset of hypotension prior to onset using convolutional neural networks. Based solely on the arterial blood pressure curve, our initial attempt can predict an onset with 60% sensitivity and 80% specificity 5-15 minutes before onset.Clinical relevance Hypotension is common during large surgery. By identifying and treating hypotensive episodes early, preferably even before onset, hypotension and its associate post- surgery complications are reduced. Even a prediction with 80% sensitivity/specificity is valuable for the anesthesiologist. 
  •  
26.
  •  
27.
  • Romu, Thobias, et al. (författare)
  • MANA - Multi scale adaptive normalized averaging
  • 2011
  • Ingår i: 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro. - : IEEE conference proceedings. - 9781424441280 ; , s. 361-364
  • Konferensbidrag (refereegranskat)abstract
    • It is possible to correct intensity inhomogeneity in fat–water Magnetic Resonance Imaging (MRI) by estimating a bias field based on the observed intensities of voxels classified as the pure adipose tissue. The same procedure can also be used to quantify fat volume and its distribution which opens up for new medical applications. The bias field estimation method has to be robust since pure fat voxels are irregularly located and the density varies greatly within and between image volumes. This paper introduces Multi scale Adaptive Normalized Average (MANA) that solves this problem bybasing the estimate on a scale space of weighted averages. By usingthe local certainty of the data MANA preserves details where the local data certainty is high and provides realistic values in sparse areas.
  •  
28.
  • Brown, Shannon, et al. (författare)
  • Intarsia-sensorized band and textrodes for real-time myoelectric pattern recognition
  • 2016
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2016 IEEE 38th Annual International Conference of the. - : Institute of Electrical and Electronics Engineers (IEEE). - 1557-170X. - 9781457702204 ; , s. 6074-6077
  • Konferensbidrag (refereegranskat)abstract
    • Surface Electromyography (sEMG) has applications in prosthetics, diagnostics and neuromuscular rehabilitation. Self-adhesive Ag/AgCl are the electrodes preferentially used to capture sEMG in short-term studies, however their long-term application is limited. In this study we designed and evaluated a fully integrated smart textile band with electrical connecting tracks knitted with intarsia techniques and knitted textile electrodes. Real-time myoelectric pattern recognition for motor volition and signal-to-noise ratio (SNR) were used to compare its sensing performance versus the conventional Ag-AgCl electrodes. After a comprehending measurement and performance comparison of the sEMG recordings, no significant differences were found between the textile and the Ag-AgCl electrodes in SNR and prediction accuracy obtained from pattern recognition classifiers.
  •  
29.
  • Pfeiffer, Christoph, 1989, et al. (författare)
  • On-scalp MEG sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration
  • 2020
  • Ingår i: Neuroimage. - : Elsevier BV. - 1053-8119 .- 1095-9572. ; 212
  • Tidskriftsartikel (refereegranskat)abstract
    • Source modelling in magnetoencephalography (MEG) requires precise co-registration of the sensor array and the anatomical structure of the measured individual's head. In conventional MEG, the positions and orientations of the sensors relative to each other are fixed and known beforehand, requiring only localization of the head relative to the sensor array. Since the sensors in on-scalp MEG are positioned on the scalp, locations of the individual sensors depend on the subject's head shape and size. The positions and orientations of on-scalp sensors must therefore be measured a every recording. This can be achieved by inverting conventional head localization, localizing the sensors relative to the head - rather than the other way around. In this study we present a practical method for localizing sensors using magnetic dipole-like coils attached to the subject's head. We implement and evaluate the method in a set of on-scalp MEG recordings using a 7-channel on-scalp MEG system based on high critical temperature superconducting quantum interference devices (high-T-c SQUIDs). The method allows individually localizing the sensor positions, orientations, and responsivities with high accuracy using only a short averaging time (<= 2 mm, < 3 degrees and < 3%, respectively, with 1-s averaging), enabling continuous sensor localization. Calibrating and jointly localizing the sensor array can further improve the accuracy of position and orientation (< 1 mm and < 1 degrees, respectively, with 1-s coil recordings). We demonstrate source localization of on-scalp recorded somatosensory evoked activity based on coregistration with our method. Equivalent current dipole fits of the evoked responses corresponded well (within 4.2 mm) with those based on a commercial, whole-head MEG system.
  •  
30.
  • Seoane, Fernando, et al. (författare)
  • Mean Expected Error in Prediction of Total Body Water: A True Accuracy Comparison between Bioimpedance Spectroscopy and Single Frequency Regression Equations
  • 2015
  • Ingår i: Biomed Research International. - : Hindawi Limited. - 2314-6133 .- 2314-6141. ; 2015:Article ID 656323
  • Tidskriftsartikel (refereegranskat)abstract
    • For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer this question by calculating the expected accuracy of a single measurement for different EBI methods. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Even the limits of agreement produced from the Bland-Altman analysis indicated that the performance of single frequency, Sun's prediction equations, at population level was close to the performance of both BIS methods; however, when comparing the Mean Absolute Percentage Error value between the single frequency prediction equations and the BIS methods, a significant difference was obtained, indicating slightly better accuracy for the BIS methods. Despite the higher accuracy of BIS methods over 50 kHz prediction equations at both population and individual level, the magnitude of the improvement was small. Such slight improvement in accuracy of BIS methods is suggested insufficient to warrant their clinical use where the most accurate predictions of TBW are required, for example, when assessing over-fluidic status on dialysis. To reach expected errors below 4-5%, novel and individualized approaches must be developed to improve the accuracy of bioimpedance-based methods for the advent of innovative personalized health monitoring applications.
  •  
31.
  • Kothapalli, Satya V.V.N. 1985- (författare)
  • Nano-Engineered Contrast Agents : Toward Multimodal Imaging and Acoustophoresis
  • 2015
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Diagnostic ultrasound (US) is safer, quicker and cheaper than other diagnostic imaging modalities. Over the past two decades, the applications of US imaging has been widened due to the development of injectable, compressible and encapsulated microbubbles (MBs) that provide an opportunity to improve conventional echocardiographic imaging, blood flow assessment and molecular imaging. The encapsulating material is manufactured by different biocompatible materials such as proteins, lipids or polymers. In current research, researchers modify the encapsulated shell with the help of advanced molecular chemistry techniques to load them with dyes (for fluorescent imaging), nanoparticles and radioisotopes (for multimodal imaging) or functional ligands or therapeutic gases (for local drug delivery). The echogenicity and the radial oscillation of MBs is the result of their compressibility, which undoubtedly varies with the encapsulated shell characteristics such as rigidity or elasticity.In this thesis, we present acoustic properties of novel type of polyvinyl alcohol (PVA)-shelled microbubble (PVA-MB) that was further modified with superparamagnetic iron oxide nanoparticles (SPIONs) to work as a dual-modal contrast agent for magnetic resonance (MR) imaging along with US imaging. Apparently, the shell modification changes their mechanical characteristics, which affects their acoustic properties. The overall objective of the thesis is to investigate the acoustic properties of modified and unmodified PVA-MBs at different ultrasound parameters.The acoustic and mechanical characterization of SPIONs modified PVA-MBs revealed that the acoustical response depends on the SPION inclusion strategy. However they retain the same structural characteristics after the modification. The modified MBs with SPIONs included on the surface of the PVA shell exhibit a soft-shelled behavior and produce a higher echogenicity than the MBs with the SPIONs inside the PVA shell. The fracturing mechanism of the unmodified PVA-MBs was identified to be different from the other fracturing mechanisms of conventional MBs. With the interaction of high-pressure bursts, the air gas core is squeezed out through small punctures in the PVA shell. During the fracturing, the PVA-MBs exhibit asymmetric (other modes) oscillations, resulting in sub- and ultra-harmonic generation. Exploiting the US imaging at the other modes of the oscillation of the PVA-MBs would provide an opportunity to visualize very low concentrations of (down to single) PVA-MBs. We further introduced the PVA-MBs along with particles mimicking red blood cells in an acoustic standing-wave field to observe the acoustic radiation force effect. We observed that the compressible PVA-MBs drawn toward pressure antinode while the solid blood phantoms moved toward the pressure node. This acoustic separation method (acoustophoresis) could be an efficient tool for studying the bioclearance of the PVA-MBs in the body, either by collecting blood samples (in-vitro) or by using the extracorporeal medical procedure (ex-vivo) at different organs.Overall, this work contributes significant feedback for chemists (to optimize the nanoparticle inclusion) and imaging groups (to develop new imaging sequences), and the positive findings pave new paths and provide triggers to engage in further research. 
  •  
32.
  • Khodadad, Davood, 1985-, et al. (författare)
  • The Value of Phase Angle in Electrical Impedance Tomography Breath Detection
  • 2018
  • Ingår i: 2018 Progress in Electromagnetics Research Symposium (PIERS-Toyama). - : Electromagnetics Academy. - 9784885523168 - 9781538654552 ; , s. 1040-1043
  • Konferensbidrag (refereegranskat)abstract
    • The objective of this paper is to report our investigation demonstrating that the phase angle information of complex impedance could be a simple indicator of a breath cycle in chest Electrical Impedance Tomography (EIT). The study used clinical neonatal EIT data. The results show that measurement of the phase angle from complex EIT data can be used as a complementary information for improving the conventional breath detection algorithms.
  •  
33.
  • Enejder, Annika, 1969, et al. (författare)
  • SHG Imaging for Tissue Engineering Applications
  • 2016
  • Ingår i: Second Harmonic Generation Imaging. - : CRC Press. - 9781439849156 - 9781439849149 ; , s. 409-426
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • Treatment of lost tissue oen relies on transplantations, either of donor or of autologous tissue. Both alternatives have limitations; there is for example a limited supply of donor transplants, which also require immunosuppression therapy with possible side eects. Transplanted autologous tissue may lack some of the functions of the original tissue and the procedure may also introduce complications at the donor site. In some cases, articial substitutes manufactured from nonbiological materials can be used, for example, synthetic polymer blood vessels or joint replacement prostheses. However, these replacements have drawbacks such as risk for infections, limited material durability, and lack of mechanisms for repair, growth, and remodeling. For these reasons, development of advanced articial tissue constructs with adaptive capabilities is desirable.
  •  
34.
  • Dyverfeldt, Petter, 1980-, et al. (författare)
  • Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI
  • 2006
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 56:4, s. 850-858
  • Tidskriftsartikel (refereegranskat)abstract
    • Turbulent flow, characterized by velocity fluctuations, is a contributing factor to the pathogenesis of several cardiovascular diseases. A clinical noninvasive tool for assessing turbulence is lacking, however. It is well known that the occurrence of multiple spin velocities within a voxel during the influence of a magnetic gradient moment causes signal loss in phase-contrast magnetic resonance imaging (PC-MRI). In this paper a mathematical derivation of an expression for computing the standard deviation (SD) of the blood flow velocity distribution within a voxel is presented. The SD is obtained from the magnitude of PC-MRI signals acquired with different first gradient moments. By exploiting the relation between the SD and turbulence intensity (TI), this method allows for quantitative studies of turbulence. For validation, the TI in an in vitro flow phantom was quantified, and the results compared favorably with previously published laser Doppler anemometry (LDA) results. This method has the potential to become an important tool for the noninvasive assessment of turbulence in the arterial tree.
  •  
35.
  • Ferreira, Javier, 1982-, et al. (författare)
  • A handheld and textile-enabled bioimpedance system for ubiquitous body composition analysis. : An initial functional validation
  • 2016
  • Ingår i: IEEE journal of biomedical and health informatics. - : Institute of Electrical and Electronics Engineers (IEEE). - 2168-2194 .- 2168-2208. ; 21:5
  • Tidskriftsartikel (refereegranskat)abstract
    • In recent years, many efforts have been made to promote a healthcare paradigm shift from the traditional reactive hospital-centered healthcare approach towards a proactive, patient-oriented and self-managed approach that could improve service quality and help reduce costs while contributing to sustainability. Managing and caring for patients with chronic diseases accounts over 75% of healthcare costs in developed countries. One of the most resource demanding diseases is chronic kidney disease (CKD), which often leads to a gradual and irreparable loss of renal function, with up to 12% of the population showing signs of different stages of this disease. Peritoneal dialysis and home haemodialysis are life-saving home-based renal replacement treatments that, compared to conventional in-center hemodialysis, provide similar long-term patient survival, less restrictions of life-style, such as a more flexible diet, and better flexibility in terms of treatment options and locations. Bioimpedance has been largely used clinically for decades in nutrition for assessing body fluid distributions. Moreover, bioimpedance methods are used to assess the overhydratation state of CKD patients, allowing clinicians to estimate the amount of fluid that should be removed by ultrafiltration. In this work, the initial validation of a handheld bioimpedance system for the assessment of body fluid status that could be used to assist the patient in home-based CKD treatments is presented. The body fluid monitoring system comprises a custom-made handheld tetrapolar bioimpedance spectrometer and a textile-based electrode garment for total body fluid assessment. The system performance was evaluated against the same measurements acquired using a commercial bioimpedance spectrometer for medical use on several voluntary subjects. The analysis of the measurement results and the comparison of the fluid estimations indicated that both devices are equivalent from a measurement performance perspective, allowing for its use on ubiquitous e-healthcare dialysis solutions.
  •  
36.
  • Macias, Raul, et al. (författare)
  • Performance of the Load-in-the-Loop Single Op-Amp Voltage Controlled Current Source from the Op-Amp Parameters
  • 2010
  • Ingår i: Journal of Physics: Conference Series. - : Institute of Physics Publishing Ltd.. - 1742-6596 .- 1742-6588.
  • Konferensbidrag (refereegranskat)abstract
    • In recent years, Electrical Bioimpedance (EBI) methods have gained importance. These methods are often based on obtaining impedance spectrum in the range of β-dispersion, i.e. from a few kHz up to some MHz. To measure EBI a constant current is often injected and the voltage across the tissue under study (TUS) is recorded. Due to the performance of the current source influences the performance of the entire system, in terms of frequency range, several designs have been implemented and studied. In this paper the basic structure of a Voltage-Controlled Current Source (VCCS) based on a single Op-Amp in inverter configuration with a floating load, known as load-in-the-loop current source, is revisited and studied deeply. We focus on the dependence of the output impedance with the circuit parameters, i.e. the feedback resistor and the inverter-input resistor, and the Op-Amp main parameters, i.e. open loop gain, CMRR and input impedance. After obtaining the experimental results and comparing to the theoretical and simulated ones, they confirm the design under study can be a good solution for multi-frequency wideband EBI applications because of higher values of the output impedance than 100kΩ at 1MHz are obtained. Furthermore, an enhancement of the basic design, using a current conveyor as a first stage, is proposed, studied and implemented.
  •  
37.
  • Ebbers, Tino, 1972- (författare)
  • Flow Imaging: Cardiac Applications of 3D Cine Phase-Contrast MRI
  • 2011
  • Ingår i: Current Cardiovascular Imaging Reports. - : Springer Science and Business Media LLC. - 1941-9074 .- 1941-9066. ; 4:2, s. 127-133
  • Forskningsöversikt (refereegranskat)abstract
    • Global and regional blood flow dynamics are of pivotal importance to cardiac function. Fluid mechanical forces can affect hemolysis and platelet aggregation, as well as myocardial remodeling. In recent years, assessment of blood flow patterns based on time-resolved, three-dimensional, three-directional phase-contrast MRI (3D cine PC MRI) has become possible and rapidly gained popularity. Initially, this technique was mainly known for its intuitive and appealing visualizations of the cardiovascular blood flow. Most recently, the technique has begun to go beyond compelling images toward comprehensive and quantitative assessment of blood flow. In this article, cardiac applications of 3D cine PC MRI data are discussed, starting with a review of the acquisition and analysis techniques, and including descriptions of promising applications of cardiac 3D cine PC MRI for the clinical evaluation of myocardial, valvular, and vascular disorders.
  •  
38.
  • Fhager, Andreas, 1976, et al. (författare)
  • Image Reconstruction in Microwave Tomography Using a Dielectric Debye Model
  • 2012
  • Ingår i: IEEE Transactions on Biomedical Engineering. - 0018-9294 .- 1558-2531. ; 59:1, s. 156 - 166
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, quantitative dielectric image reconstruction based on broadband microwave measurements is investigated. A time-domain-based algorithm is derived where Debye model parameters are reconstructed in order to take into account the strong dispersive behavior found in biological tissue. The algorithm is tested with experimental and numerical data in order to verify the algorithm and to investigate improvements in the reconstructed image resulting from the improved description of the dielectric properties of the tissue when using broadband data. The comparison is made in relation to the more commonly used conductivity model. For the evaluation, two examples were considered, the first was a lossy saline solution and the second was less lossy tap water. Both liquids are strongly dispersive and used as a background medium in the imaging examples. The results show that the Debye model algorithm is of most importance in the tap water for a bandwidth of more than 1.5 GHz. Also the saline solution exhibits a dispersive behavior but since the losses restrict the useful bandwidth, the Debye model is of less significance even if somewhat larger and stronger artifacts can be seen in the conductivity model reconstructions.
  •  
39.
  • Fredriksson, Ingemar, 1980-, et al. (författare)
  • Microcirculatory changes in type 2 diabetes assessed with velocity resolved quantitative laser Doppler flowmetry
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • The response to local heating (44oC for 20 min) was evaluated in 28 type 2 diabetes patients (DM) and 29 non-diabetes controls (ND). Microcirculatory perfusion was assessed using conventional and quantitative Laser Doppler flowmetry (cLDF and qLDF), respectively. The qLDF estimates perfusion in a physiological relevant unit (g RBC / 100 g tissue × mm/s) in a fixed output volume, separated into three velocity regions, v < 1 mm/s, 1 - 10 mm/s, and v > 10 mm/s. Perfusion in cLDF is given in arbitrary units with unknown velocity distribution and measurement volume. A significantly lower response in DM than in ND was found after heat provocation both for the initial peak and the plateau response, while no significant differences were found at baseline. The qLDF showed increased perfusion for the velocity regions 1-10 mm/s and above 10 mm/s, while no significant increase was found for v < 1 mm/s. In conclusion, we found a lowered LDF response to local heating in DM. The new qLDF method showed that the increased blood flow occurs in vessels with a velocity above 1 mm/s. Baseline qLDF-data indicated that a redistribution of flow to higher velocity regions was associated with longer DM duration and for DM a negative correlation between perfusion and BMI.
  •  
40.
  • Stading, Mats, 1962, et al. (författare)
  • A Device that Models Human Swallowing
  • 2019
  • Ingår i: Dysphagia. - : Springer Science and Business Media LLC. - 0179-051X .- 1432-0460. ; 34:5, s. 615-626
  • Forskningsöversikt (refereegranskat)abstract
    • The pharynx is critical for correct swallowing, facilitating the transport of both air and food transport in a highly coordinated manner, and aberrant co-ordination causes swallowing disorders (dysphagia). In this work, an in vitro model of swallowing was designed to investigate the role of rheology in swallowing and for use as a pre-clinical tool for simulation of different routes to dysphagia. The model is based on the geometry of the human pharynx. Manometry is used for pressure measurements and ultrasonic analysis is performed to analyze the flow profiles and determine shear rate in the bolus, the latter being vital information largely missing in literature. In the fully automated model, bolus injection, epiglottis/nasopharynx movement, and ultrasound transducer positioning can be controlled. Simulation of closing of the airways and nasal cavity is modulated by the software, as is a clamping valve that simulates the upper esophageal sphincter. The actions can be timed and valves opened to different degrees, resembling pathologic swallowing conditions. To validate measurements of the velocity profile and manometry, continuous and bolus flow was performed. The respective velocity profiles demonstrated the accuracy and validity of the flow characterization necessary for determining bolus flow. A maximum bolus shear rate of 80 s−1 was noted for syrup-consistency fluids. Similarly, the manometry data acquired compared very well with clinical studies.
  •  
41.
  • Tomasic, Ivan, et al. (författare)
  • Comparison of publicly available beat detection algorithms performances on the ECGs obtained by a patch ECG device
  • 2019
  • Ingår i: 2019 42nd International Convention on Information and Communication Technology, Electronics and Microelectronics, MIPRO 2019 - Proceedings. - : Institute of Electrical and Electronics Engineers Inc.. - 9789532330984 ; , s. 275-278
  • Konferensbidrag (refereegranskat)abstract
    • Eight ECG beat detection algorithms, from the PhysioNet's WFDB and Cardiovascular Signal toolboxes, were tested on twenty measurements, obtained by the Savvy patch ECG device, for their accuracy in beat detection. On each subject, one measurement is obtained while sitting and one while running. Each measurement lasted from thirty seconds to one minute. The measurements obtained while running were more challenging for all the algorithms, as most of them almost perfectly detected all the beats on the measurements obtained in sitting position. However, when applied on the measurements obtained while running, all the algorithms have performed with decreased accuracy. Considering overall percentage of the faulty detected peaks, the four best algorithms were jqrs, from the Cardiovascular Signal Toolbox, and ecgpuwave, gqrs, and wqrs, from the WFDB Toolbox, with percentages of faulty detected beats 1.7, 2.3, 2.9, and 3, respectively. 
  •  
42.
  • Zanoli, Massimiliano, 1989 (författare)
  • Ultra wideband microwave hyperthermia for brain cancer treatment
  • 2022
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Despite numerous clinical trials demonstrating that microwave hyperthermia is a powerful adjuvant modality in the treatment of cancers, there have been few instances where this method has been applied to brain tumors. The reason is a combination of anatomical and physiological factors in this site that require an extra degree of accuracy and precision in the thermal dose delivery. Current clinical applicators are not able to provide such control, partly because they are designed to operate at a single fixed frequency. In terms of treatment planning, the use of a single frequency is limiting as the size of the focal spot cannot be modified to accommodate the specific tumor volume and location. The introduction of ultra wide-band (UWB) systems opens up an opportunity to overcome these limitations, as they convey the possibility of adapting the focal spot and obtaining different power deposition patterns to reduce the heating of healthy tissues. In this thesis, we explore whether the current SAR-based treatment planning methods can be meaningfully translated to the UWB setting and propose new solutions for deep UWB microwave hyperthermia. We analyze the most commonly used cost functions for treatment planning optimization and discuss their suitability for use with UWB systems. Then, we propose a novel SAR-based cost function (HCQ) for UWB optimization that exhibits a high correlation with the resulting tumor temperature. To solve for the HCQ, we describe a novel, time-reversal-based, iterative scheme for a rapid and efficient optimization of UWB treatment plans. Next, we investigate the design possibilities of UWB brain applicators and introduce a fast E-field approximation scheme to quickly explore a large number of array configurations. The method determines the best antenna arrangement around the head with respect to the multiple objectives and requirements of clinical hyperthermia. Together, the proposed solutions manage to achieve the level of tumor coverage and hot-spot suppression that is necessary for a successful treatment. Finally, we investigate the benefit of integrating hyperthermia delivered by an optimized UWB applicator into the radiation therapy plan for a pediatric medulloblastoma patient. The results suggest that UWB microwave hyperthermia for brain cancer treatment is feasible and motivate efforts for further development of UWB applicators and systems.
  •  
43.
  • Buendia, Ruben, 1982, et al. (författare)
  • A Novel Approach for Removing the Hook Effect Artefact from Electrical Bioimpedance Spectroscopy Measurements
  • 2009
  • Ingår i: Journal of Physics: Conference Series. - : Institute of Physics Publishing Ltd.. - 1742-6596.
  • Konferensbidrag (refereegranskat)abstract
    • Very often in Electrical Bioimpedance (EBI) spectroscopy measurements the presence of stray capacitances creates a measurement artefact commonly known as Hook Effect. Such an artefact creates a hook-alike deviation of the EBI data noticeable when representing the measurement on the impedance plane. Such Hook Effect is noticeable at high frequencies but it also causes a data deviation at lower measurement frequencies. In order to perform any accurate analysis of the EBI spectroscopy data, the influence of the Hook Effect must be removed. An established method to compensate the hook effect is the well known Td compensation, which consist on multiplying the obtained spectrum, Zmeas() by a complex exponential in the form of exp[jTd]. Such a method cannot correct entirely the Hook Effect since the hook-alike deviation occurs a broad frequency range in both magnitude and phase of the measured impedance, and by using a real value for Td. First, a real value only modifies the phase of the measured impedance and second, it can only correct the Hook Effect at a single frequency. In addition, the process to select a value for Td by an iterative process with the aim to obtain the best Cole fitting lacks solid scientific grounds. In this work the Td compensation method is revisited and a modified approach for correcting the Hook Effect that includes a novel method for selecting the correcting values is proposed. The initial validation results confirm that the proposed method entirely corrects the Hook Effect at all frequencies.
  •  
44.
  • Decrop, Deborah, et al. (författare)
  • Single-step manufacturing of femtoliter microwell arrays in a novel surface energy mimicking polymer
  • 2015
  • Ingår i: 18th International Conference on Solid-State Sensors, Actuators and Microsystems (IEEE TRANSDUCER 2015). - : IEEE.
  • Konferensbidrag (refereegranskat)abstract
    • We report a novel polymer material formulation and stamp-molding technique that enable rapid single-step manufacturing of hydrophilic-in-hydrophobic microwell arrays. We developed a modified thiol-ene-epoxy polymer (mOSTE+) formulation that mimics the surface energy of its mold during polymerization. The polymer inherits the surface energy from the mold through molecular self-assembly, in which functional monomers self-assemble at the interface between the liquid prepolymer and the mold surface. Combining this novel mOSTE+ material with a stamp-molding process leads to simultaneous surface energy mimicking and micro-structuring. This method was used to manufacture microwells with hydrophilic bottom and hydrophobic sidewall, depressed in a surrounding hydrophobic surface. The microwell arrays were successfully tested for the self-assembly of 62’000 femtoliter-droplets. Such femtoliter droplet arrays are useful for, e.g., digital ELISA and single cell/molecule analysis applications.
  •  
45.
  • Morin, Maxim, et al. (författare)
  • Skin hydration dynamics investigated by electrical impedance techniques in vivo and in vitro
  • 2020
  • Ingår i: Scientific reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 10:1, s. 17218-
  • Tidskriftsartikel (refereegranskat)abstract
    • Skin is easily accessible for transdermal drug delivery and also attractive for biomarker sampling. These applications are strongly influenced by hydration where elevated hydration generally leads to increased skin permeability. Thus, favorable transdermal delivery and extraction conditions can be easily obtained by exploiting elevated skin hydration. Here, we provide a detailed in vivo and in vitro investigation of the skin hydration dynamics using three techniques based on electrical impedance spectroscopy. Good correlation between in vivo and in vitro results is demonstrated, which implies that simple but realistic in vitro models can be used for further studies related to skin hydration (e.g., cosmetic testing). Importantly, the results show that hydration proceeds in two stages. Firstly, hydration between 5 and 10 min results in a drastic skin impedance change, which is interpreted as filling of superficial voids in skin with conducting electrolyte solution. Secondly, a subtle impedance change is observed over time, which is interpreted as leveling of the water gradient across skin leading to structural relaxation/changes of the macromolecular skin barrier components. With respect to transdermal drug delivery and extraction of biomarkers; 1 h of hydration is suggested to result in beneficial and stable conditions in terms of high skin permeability and extraction efficiency.
  •  
46.
  • Vega-Barbas, Mario, et al. (författare)
  • Utilizing Smart Textiles-Enabled Sensorized Toy and Playful Interactions for Assessment of Psychomotor Development on Children
  • 2015
  • Ingår i: Journal of Sensors. - : Hindawi Publishing Corporation. - 1687-725X .- 1687-7268. ; 2015
  • Tidskriftsartikel (refereegranskat)abstract
    • Emerging pervasive technologies like smart textiles make it possible to develop new and more accessible healthcare services for patients independently of their location or time. However, none of these new e-health solutions guarantee a complete user acceptance, especially in cases requiring extensive interaction between the user and the solution. So far, researchers have focused their efforts on new interactions techniques to improve the perception of privacy and confidence of the people using e-health services. In this way, the use of smart everyday objects arises as an interesting approach to facilitate the required interaction and increase user acceptance. Such Smart Daily Objects together with smart textiles provide researchers with a novel way to introduce sophisticated sensor technology in the daily life of people. This work presents a sensorized smart toy for assessment of psychomotor development in early childhood. The aim of this work is to design, develop, and evaluate the usability and playfulness of a smart textile-enabled sensorized toy that facilitates the user engagement in a personalized monitoring healthcare activity. To achieve this objective the monitoring is based on a smart textile sensorized toy as catalyzer of acceptance and multimodal sensing sources to monitor psychomotor development activities during playtime.
  •  
47.
  • Fan, Xuelong, et al. (författare)
  • Effects of sensor types and angular velocity computational methods in field measurements of occupational upper arm and trunk postures and movements
  • 2021
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 21:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Accelerometer-based inclinometers have dominated kinematic measurements in previous field studies, while the use of inertial measurement units that additionally include gyroscopes is rapidly increasing. Recent laboratory studies suggest that these two sensor types and the two commonly used angular velocity computational methods may produce substantially different results. The aim of this study was, therefore, to evaluate the effects of sensor types and angular velocity computational methods on the measures of work postures and movements in a real occupational setting. Half-workday recordings of arm and trunk postures, and movements from 38 warehouse workers were compared using two sensor types: accelerometers versus accelerometers with gyroscopes—and using two angular velocity computational methods, i.e., inclination velocity versus generalized velocity. The results showed an overall small difference (<2° and value independent) for posture percentiles between the two sensor types, but substantial differences in movement percentiles both between the sensor types and between the angular computational methods. For example, the group mean of the 50th percentiles were for accelerometers: 71°/s (generalized velocity) and 33°/s (inclination velocity)—and for accelerometers with gyroscopes: 31°/s (generalized velocity) and 16°/s (inclination velocity). The significant effects of sensor types and angular computational methods on angular velocity measures in field work are important in inter-study comparisons and in comparisons to recommended threshold limit values.
  •  
48.
  •  
49.
  • Shahgaldi, Kambiz, et al. (författare)
  • Flow-volume loops derived from three-dimensional echocardiography : a novel approach to the assessment of left ventricular hemodynamics
  • 2008
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: This study explores the feasibility of non-invasive evaluation of left ventricular (LV) flow-volume dynamics using 3-dimensional (3D) echocardiography, and the capacity of such an approach to identify altered LV hemodynamic states caused by valvular abnormalities. Methods: Thirty-one patients with moderate-severe aortic (AS) and mitral (MS) stenoses (21 and 10 patients, respectively) and 10 healthy volunteers underwent 3D echocardiography with full volume acquisition using Philips Sonos 7500 equipment. The digital 3D data were post-processed using TomTec software. LV flow-volume loops were subsequently constructed for each subject by plotting instantaneous LV volume data sampled throughout the cardiac cycle vs. their first derivative representing LV flow. After correction for body surface area, an average flow-volume loop was calculated for each subject group. Results: Flow-volume loops were obtainable in all subjects, except 3 patients with AS. The flow-volume diagrams displayed clear differences in the form and position of the loops between normal individuals and the respective patient groups. In patients with AS, an "obstructive" pattern was observed, with lower flow values during early systole and larger end-systolic volume. On the other hand, patients with MS displayed a "restrictive" flow-volume pattern, with reduced diastolic filling and smaller end-diastolic volume. Conclusion: Non-invasive evaluation of LV flow-volume dynamics using 3D-echocardiographic data is technically possible and the approach has a capacity to identify certain specific types of alteration of LV flow-volume pattern caused by valvular abnormalities, thus reflecting underlying hemodynamic states specific for these abnormalities.
  •  
50.
  • Halawani, Alaa, et al. (författare)
  • Building eye contact in e-learning through head-eye coordination
  • 2011
  • Ingår i: International Journal of Social Robotics. - Dordrecht : Springer. - 1875-4791 .- 1875-4805. ; 3:1, s. 95-106
  • Tidskriftsartikel (refereegranskat)abstract
    • Video conferencing is a very effective tool to use for e-learning. Most of the available video conferencing systems suffer a main drawback represented by the lack of eye contact between participants. In this paper we present a new scheme for building eye contact in e-learning sessions. The scheme assumes a video conferencing session with “one teacher many students” arrangement. In our system, eye contact is achieved without the need for any gaze estimation technique. Instead, we “generate the gaze” by allowing the user communicate his visual attention to the system through head-eye coordination. To enable real time and precise headeye coordination, a head motion tracking technique is required. Unlike traditional head tracking systems, our procedure suggests mounting the camera on the user’s head rather than in front of it. This configuration achieves much better resolution and thus leads to better tracking results. Promising results obtained from both demo and real time experiments demonstrate the effectiveness and efficiency of the proposed scheme. Although this paper concentrates on elearning, the proposed concept can be easily extended to the world of interaction with social robotics, in which introducing eye contact between humans and robots would be of great advantage.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-50 av 1226
Typ av publikation
tidskriftsartikel (625)
konferensbidrag (398)
doktorsavhandling (87)
forskningsöversikt (35)
bokkapitel (28)
licentiatavhandling (24)
visa fler...
rapport (12)
annan publikation (12)
samlingsverk (redaktörskap) (3)
patent (2)
konstnärligt arbete (1)
visa färre...
Typ av innehåll
refereegranskat (969)
övrigt vetenskapligt/konstnärligt (249)
populärvet., debatt m.m. (8)
Författare/redaktör
Persson, Mikael, 195 ... (46)
Lindecrantz, Kaj, 19 ... (40)
Seoane, Fernando, 19 ... (39)
Wårdell, Karin (38)
Fhager, Andreas, 197 ... (34)
Brodin, Lars-Åke (28)
visa fler...
Strömberg, Tomas (27)
Osvalder, Anna-Lisa, ... (22)
Laurell, Thomas (20)
Larsson, Marcus (20)
Fredriksson, Ingemar (19)
Seoane Martinez, Fer ... (19)
Jalkanen, Ville, 197 ... (19)
Bergh, Anders (17)
Augustine, Robin, 19 ... (17)
Grishenkov, Dmitry, ... (17)
Tenje, Maria (16)
Bligård, Lars-Ola, 1 ... (16)
Thordstein, Magnus (15)
Dobsicek Trefna, Han ... (15)
Knutsson, Hans (14)
Lindahl, Olof A. (14)
Ljungberg, Börje (13)
Ramser, Kerstin (13)
Theodorsson, Elvar (12)
Ask, Per (12)
Kjellmer, Ingemar, 1 ... (12)
Lindahl, Olof (12)
Cinthio, Magnus (11)
Paradossi, Gaio (11)
Danielsson, Mats (11)
Nilsson, Gert (11)
Cederström, Björn (11)
Borga, Magnus (10)
Lindecrantz, Kaj (10)
Janerot-Sjöberg, Bir ... (10)
Olsson, Torsten, 193 ... (10)
Candefjord, Stefan, ... (10)
Seoane, Fernando (9)
Torres Company, Vict ... (9)
Holzapfel, Gerhard A ... (9)
Ebbers, Tino (9)
Löfgren, Nils, 1969 (9)
Buendia, Ruben, 1982 (9)
Andersson-Engels, St ... (8)
Gil-Pita, Roberto (8)
Augustsson, Per (8)
Reinfeldt, Sabine, 1 ... (8)
Winter, Reidar (8)
Nowak, Jacek (8)
visa färre...
Lärosäte
Chalmers tekniska högskola (364)
Kungliga Tekniska Högskolan (278)
Linköpings universitet (255)
Lunds universitet (181)
Göteborgs universitet (96)
Uppsala universitet (88)
visa fler...
Umeå universitet (80)
Karolinska Institutet (77)
Högskolan i Borås (59)
Luleå tekniska universitet (22)
Blekinge Tekniska Högskola (18)
RISE (14)
Örebro universitet (13)
Linnéuniversitetet (13)
Mälardalens universitet (12)
Stockholms universitet (11)
Jönköping University (11)
Malmö universitet (9)
VTI - Statens väg- och transportforskningsinstitut (8)
Gymnastik- och idrottshögskolan (7)
Högskolan i Halmstad (6)
Sveriges Lantbruksuniversitet (6)
Mittuniversitetet (4)
Högskolan Kristianstad (3)
Högskolan i Gävle (1)
Högskolan Väst (1)
Högskolan i Skövde (1)
Karlstads universitet (1)
Högskolan Dalarna (1)
visa färre...
Språk
Engelska (1196)
Svenska (26)
Tyska (2)
Rumänska (1)
Kinesiska (1)
Forskningsämne (UKÄ/SCB)
Teknik (1226)
Medicin och hälsovetenskap (311)
Naturvetenskap (241)
Samhällsvetenskap (28)
Humaniora (9)
Lantbruksvetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy